PRIORITY VALVES FOR HKUS.../5... TYPE PR... The Priority Valves distribute and trace the hydraulic flow from the supply pump of the hydraulic system to the hydraulic components which control and run the vehicle. The Priority Valves are used only with the HKUS.../5(D)(T) hydrostatic steering units. When connected, the steering unit and the priority valve represent sophisticated hydraulic tracing system that controls the flow in both main pipelines of the hydraulic system (the working and control one) at any time of its operation. As a static signal, the "LS" signal must be used in systems with circuit stability. The connection between the PRT, PRTA priority valves and the HKUS.../5T steering units has to be as short as possible, but should not exceed 1,5 m [4.92 ft] (for iron pipe with 4 mm [.157 in.] internal diameter). When a rubber hose is used this length has to be even shorter. Priority valves with dynamic signal work in a system with dynamic hydrostatic steering units type HKUS.../5D (5DT). Modulary Mounting LS CF L T R R LS CF L L Pipe Mounting L EF CF T R R LS P EF T P P EF T Static signal Dynamic signal Static signal PRD 40,80/... PRDD 40,80/... PRT 40,80,120/..., PRTA 40,80/... EF CF PR...40 P-EF [bar] LS P-EF [PSI] P Dynamic signal 14 12 180 10 140 PRTD 40,80,120/...,PRTAD40,80/... 10 bar EF CF 7 bar 8 100 6 4 2 LS PP 4 bar 60 P Min. 20 0 2 0 4 10 6 20 8 10 30 40 Qp Static signal with External Port [GPM] PRTE120/... Qp [l/min] PR...80 PRТ...120 P-EF [PSI] P-EF [bar] 14 12 10 10 bar 180 16 14 7 bar 140 100 10 4 bar 6 60 4 Min. 20 Qp 0 2 0 6 20 10 40 200 10 bar 14 18 60 7 bar 150 4 bar 8 6 2 250 12 8 4 P-EF [PSI] P-EF [bar] [GPM] 100 Min. 50 Qp [GPM] 2 0 80 Qp [l/min] 0 5 0 21 20 10 40 15 60 20 80 25 100 30 120 Qp [l/min] PRD ,PRT PRT PRD, PRIORITY VALVES VALVES PRIORITY SPECIFICATION DATA Type Parameters PRD(D), PRT(D) Rated Flow . Control Spring Pressure . Max. Pressures in Oil Ports: bar [PSI] lpm [GPM] bar [PSI] PRTA(D) 40 [10.6] 4 [58] 80 [21.1] 4 [58] 10 7 [101.5] [145] 120 [31.7] 4 10 7 [101.5] [145] [58] P, EF 250 [3625] CF 210 [3045] 280 [4061] R, L PRT(D)(E) 10 7 [101.5] [145] 210 [3045] LS 210 [3045] PP 20 [290] . T Weight . 2,25 [4.96] kg [lb] 2,1 [4.6] 1,3 [2.87] P - pump, EF - excess flow, CF - control flow (first priority oil flow), L - left, R - right, LS - load sensing, T - tank, PP - pilot pressure (L,R and T - for PRD(D) only). DIMENSIONS AND MOUNTING DATA - PRD(D) 40, 80/... 44 [1.732] 42 [1.654] 44 [1.732] 123 [4.843] c o d e 87 [3.425] R 87 [3.425] P 60 [2.362] T EF P T * 20 [.787] 78 [3.071] L R 35 [1.378] EF L Ports - P, EF Thread Ports - T, R, L Thread - G1/2 18 [.71] depth G3/8 18 [.71] depth M M22x1,5 18 [.71] depth M18x1,5 18 [.71] depth A 7/8 - 14 UNF O-ring 18 [.71] depth 3/4 - 16 UNF O-ring 18 [.71] depth * Connection to the HKUS.../5(D)... is done with 2 screws M10x1x45 -10.9 DIN 912 or with 2 screws 3/8-24 UNF ANSI B18.3-76, 1.75'' long. Tightening torque: 4,5±0,5 daNm [360 ± 440 lb-in ]. mm [in] 22 PRD PRT PRD,, PRT PRIORITY VALVES DIMENSIONS AND MOUNTING DATA - PRT(D) 40, 80/... EF 2 x ø17 [.669] 22 [.866] LS 142 [5.6] 87 [3.43] 87 [3.43] 60 [2.36] P EF 0,1 [.004] 42 [1.654] 11 [.431] 35 [1.378] P 20 [.787] 78 [3.071] CF 22 [.866] 2 x ø10,5 [.413] c o d e Ports - P, EF Thread Port - CF Thread LS - Port - G1/2 18 mm [.71] depth G1/2 18 mm [.71] depth G1/4 14 mm [.55] depth M M 22x1,5 18 mm [.71] depth M 22x1,5 18 mm [.71] depth G1/4 14 mm [.55] depth A CF 7/8 - 14 UNF 7/16 - 20 UNF 3/4 - 16 UNF O-ring 18 [.71] depth O-ring 18 [.71] depth O-ring 12,7 [.50] depth DIMENSIONS AND MOUNTING DATA - PRTA(D) 40, 80/... CF EF 25[.984] S=24 [.945] 20,3 [.799] 40 [1.575] LS P 19,7 [.776] 80 [3.150] 19,7 [.776] ø8,5 [.335] P LS 20,5 [.807] 42 [1.654] 41 [1.614] 142 [5.591] CF EF c o d e Ports - P, EF Thread Port - CF Thread LS - Port - G1/2 18 mm [.71] depth G1/2 18 mm [.71] depth G1/4 14 mm [.55] depth M M 22x1,5 18 mm [.71] depth M 22x1,5 18 mm [.71] depth G1/4 14 mm [.55] depth A 7/8 - 14 UNF 7/16 - 20 UNF 3/4 - 16 UNF O-ring 18 [.71] depth O-ring 18 [.71] depth O-ring 12,7 [.50] depth mm [in] 23 PRD PRT PRD,, PRT PRIORITY VALVES DIMENSIONS AND MOUNTING DATA - PRT...120/... 29.3 [1.154] P 57,1 [2.248] EF 116 [4.570] 138 [5.433] 48 [1.890] 24 [.945] LS PP S=19 [.748] 28 [1.102] 10 [.394] 18.7 [.736] 56 [2.205] CF 38.4 [1.512] 24 [.945] ø34 [1.339] 0,8 [.032] depth c o d e Ports - P, EF Thread Port - CF Thread LS, PP - Ports - G3/4 20,5 [.81] depth G1/2 18,5 [.73] depth G1/4 12,5 [.49] depth M M27x2 20,5 [.81] depth M18x1,5 18,5 [.73] depth M12x1,5 12,5 [.49] depth 3/4 - 16 UNF 7/16 - 20 UNF 1 1/16 - 12 UN A O-ring 20,5 [.81] depth O-ring 18,5 [.73] depth O-ring 12,5 [.49] depth mm [in] 24 2x ø8,7 [.343] 52 [2.047] 93 [3.660] 52 [2.047] 66 [2.598] S=19 [.748] PRIORITY VALVES FOR HKU(S).../5T... TYPE PRT...160/... EF CF LS The Priority Valves PRT...160 have a built-in pilot pressure relief valve, which protects the steering unit against excessive pressure. The pilot pressure relief valve operates with the Shuttle of the Priority valve to limit the maximum steering pressure P-T measured across the ports of the steering unit. T P Static signal PRT 160/... SPECIFICATION DATA Type Parameters Rated Flow . Control Spring Pressure . Max. Pressures in Oil Ports: bar [PSI] EF CF lpm [GPM] bar [PSI] 160 [42.3] 4 [58] 10 7 [101.5] [145] P, EF 350 [5076] CF 210 [3045] LS 210 [3045] . Dynamic signal PRTD 160/... EF CF 15 [217] T Standard Relief Valve Pressure Settings bar [PSI] * Weight kg . [lb] T P 210 [3045] PP 175 [2540] 4,4 [9.70] T Static signal with External Pilot PRTE 160/... * - Adjusted valve pressure from 80 bar [1160 PSI] to 210 bar [3045 PSI] upon customer request. P - pump, EF - excess flow, CF - control flow (first priority oil flow), LS - load sensing, T - tank, PP - pilot pressure PR...160/... P-EF [PSI] 14 12 180 10 bar 7 bar 10 140 8 6 4 2 0 4 bar 100 Min. 60 20 Qp 0 4 0 10 8 12 20 30 40 LS PP P P-EF [bar] LS PRT(D), PRTE 16 50 60 70 20 24 28 32 36 40 42 [GPM] 80 90 100 110 120 130 140 150 160 Qp [l/min] 25 PRT PRIORITY VALVES DIMENSIONS AND MOUNTING DATA - PRT(D)(E)160/... EF CF 59 [2.323] 122 [4.803] 177,5 [6.988] 75 [2.953] T 32,5 [1.280] 35[1.378] 65 [2.559] 28,5 [1.122] 35 [1.378] 59 [2.323] 60,5 [2.382] 75 [2.953] 24 [.945] 32 [1.260] 121[4.764] 60,5 [2.382] 132,5 [5.217] max PP 2x ø9 [.354] 32,8 [1.291] 63 [2.480] LS 130 [5.118] 99 [3.898] 40 [1.575] P 2x ø42 [1.654] 0,8 [.031] depth c o d e Ports - P, EF Thread Port - CF Thread LS, PP, T - Ports - G3/4 20,5 [.81] depth G1/2 18,5 [.73] depth G1/4 12,5 [.49] depth M M27x2 20,5 [.81] depth M18x1,5 18,5 [.73] depth M12x1,5 12,5 [.49] depth 3/4 - 16 UNF 7/16 - 20 UNF 1 1/16 - 12 UN A O-ring 20,5 [.81] depth O-ring 18,5 [.73] depth O-ring 12,5 [.49] depth mm [in] 26 PR... PRIORITY VALVES ORDER CODE 1 2 3 / PR 5 4 7 6 - Pos.5 - Ports Pos.1 - Mounting D - Modularly Mounting T - Pipe Mounting (Model 1) TA - Pipe Mounting (Model 2) omit - BSPP (ISO 228) M - Metric (ISO 262) A - SAE (ANSI B 1.1 - 1982) Pos.6 - Option [Paint]*** omit - No Paint P - Painted Low Gloss Color PC - Corrosion Protected Paint Pos.2 - Signal Type omit - with Static signal D - with Dynamic signal E* - with Static signal and External Pilot Pos.7 - Design Series omit - Factory specified Pos.3 - Rated Flow, l/min 40 80 120** 160** Pos.4 - Control Spring Pressure , bar 4 7 10 Notes: * For PRT 120/... and PRT 160/... only ** For PRT only *** Colour at customer’s request. The priority valves are mangano-phosphatized as standard. 27
© Copyright 2026 Paperzz