Daylight, Sunlight and Overshadowing Assessment Northern Terrace Phase 1 - Paxton Development For Tottenham Hotspur Football Club August 2016 XCO2 energy w: www.xco2energy.com :: e: [email protected] t: +44 (0) 20 7700 1000 :: f: +44 (0) 20 7183 6620 17-18 Hayward’s Place :: Clerkenwell :: London :: EC1R 0EQ Daylight, Sunlight and Overshadowing Contents Executive Summary.......................................................................................... 3 Introduction...................................................................................................... 5 Site..................................................................................................................... 5 Methodology.................................................................................................... 6 Daylight Assessment........................................................................................ 7 Sunlight Assessment....................................................................................... 13 Overshadowing Assessment.......................................................................... 14 Conclusion........................................................................................................ 15 Appendix - Detailed results............................................................................ 16 About us: XCO2 Energy are a low-carbon consultancy working in the built environment. We are a multi-disciplinary company consisting of both architects and engineers, with specialists including CIBSE low carbon consultants, Code for Sustainable Homes, EcoHomes and BREEAM assessors, BRE trained daylight consultants and LEED accredited professionals. Issue 01 Issue 02 Remarks Draft Final Prepared by DB DB Checked by KM KM Authorised by RM RM Date Project reference 29/07/2016 8714 02/08/2016 8714 Northern Terrace Phase 1 - Paxton Development Issue 03 Issue 04 Daylight, Sunlight and Overshadowing Executive Summary Daylight and Sunlight analysis was carried out for the proposed development at Paxton Road located within the London Borough of Haringey. This report outlines the results of the analysis for the planning application, assessing the daylight and sunlight impacts on surrounding developments. The methodology set out in this report is in accordance with BRE’s “Site Layout Planning for Daylight and Sunlight, A Guide to Good Practice” by PJ Littlefair (2011) which is accepted as good practice by Planning Authorities. The following assessments were carried out: • Daylight: 25 Degree Line • Daylight: Vertical Sky Component • Daylight: No Sky Line • Sunlight: Sunlight Access • Sunlight: Sunlight Overshadowing Computer modelling software was used to carry out the assessments. The model used was based on architectural drawings, desktop research and a 3D model provided by the design team. Daylight Assessment A total of 28 windows from buildings surrounding the site were highlighted as being in close proximity to, and facing the proposed development. Daylighting levels for potentially affected windows of surrounding developments by the proposed development were found to be acceptable. In summary, • 4 out of 28 windows passed the 25 degree line test; • 14 of the remaining 24 windows achieved a VSC of greater than 27%; • 4 windows achieved relative VSCs over 0.8 of their former value • Two of the remaining six windows are most likely to serve a dual aspect room, indicating sufficient daylight received by this room. • One of the remaining four windows is most likely to serve a corridor space where daylight expectation is low. • The remaining three windows serve the same room which is expected to result in good levels of daylight. Overall, the development is not anticipated to have any impact on the daylight received by neighbouring properties. Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing Sunlight Assessment A total of 24 windows from buildings surrounding the site were assessed for sunlight access. The analysis indicated that 4 of the 24 windows passed the 25 degree line test. All of the remaining 20 windows apart from two, satisfied the BRE criteria for annual probable sunlight hours (APSH) and winter probable sunlight hours (WPSH). The remaining two windows were found to serve a dual aspect room where the window on the other aspect is performing well. Therefore, the proposed development is not considered to have any impact on sunlight access to windows of surrounding developments. Overshadowing Assessment One open space was identified to be in close proximity to the proposed development, and has been included in the overshadowing assessment. All the assessed space receives at least 2 hours or more of sunlight on 21 March on at least 50% of its area under the proposed site condition. Therefore, the proposed development does not have a significant impact on sunlight access to the existing amenity space. Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing Introduction Site This report assesses the daylight, sunlight and overshadowing impacts the proposed development at Paxton Road may have on the existing properties and open spaces surrounding the site. The proposed development comprises the construction of a 3 storey above ground unit, incorporating ticket windows, office space and a retail unit in the London Borough of Haringey. The approach is based on the BRE’s “Site Layout Planning for daylight and sunlight, a Guide to good practice” PJ Littlefair 2011, which is generally accepted as good practice by Town and Country Planning authorities. Site analysis was carried out to identify any potential daylight and sunlight impacts on the surrounding developments. The relevant properties tested in this report are situated close to the proposed development, and annotated in the figure below. It should be noted that although the numerical values stated by the BRE provide useful guidance to designers, consultants and planning officials, these are purely advisory and may vary depending on context. Dense urban areas, for example, may often experience greater site constraints when compared to low-rise suburban areas, and thus a high degree of obstruction is often unavoidable. N 796 High Road 794 High Road 790 High Road Aerial view of surrounding areas of the proposed development (approximate site area highlighted in pink). Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing Methodology The following methodology was used to carry out the daylight, sunlight and overshadowing assessments. The methodology is based on the guidelines set out in the BRE “Site Layout Planning for Daylight and Sunlight, A Guide to Good Practice” (2011). Daylight 1. Daylight to surrounding windows A plane is drawn at 25 degrees from the horizontal, at the centre of an existing window. If the new development intersects with this plane, the internal daylight levels of the surrounding windows may be reduced. When an obstruction of the 25 degree plane occurs, a more detailed assessment involving the Vertical Sky Component of the affected window would need to be carried out. 2. Absolute Vertical Sky Component The Vertical Sky Component is the ratio of the direct sky illuminance falling on the vertical wall at a reference point, to the simultaneous horizontal illuminance under an unobstructed sky. To maintain good levels of daylight, the Vertical Sky Component of a window needs to be 27% or greater. If the VSC is less than 27%, then a comparison of existing and proposed levels of VSC level would need to be calculated. 3. Relative Vertical Sky Component Good levels of daylighting can still be achieved if VSC levels are within 80% of their former value. 4. % of room with view of the sky (NSL) Rooms connected to the windows assessed will not experience a noticeable loss in daylight if the percentage (%) of the room’s working plane with view of the sky is over 0.8 of its former value. The former value could refer either to the existing development in place or the mirror image buildings for properties with windows close to site boundaries. Northern Terrace Phase 1 - Paxton Development Sunlight Access to sunlight (APSH) The BRE test relates mainly to existing living room windows, although care should be taken to ensure that kitchens and bedrooms receive reasonable amounts of sunlight. Annual Probable Sunlight Hour (APSH) assessment is carried when there is an obstruction within the 25 degree line, calculated from the centre of the window and the proposed development is situated within 90 degrees due south of the window. The APSH assessment states that the existing living room window should receive at least: • 25% of annual probable sunlight hours (APSH) throughout the year; • 5% of annual probable sunlight hours during the winter months; • not less than 80% of it’s former sunlight hours during either period; • not more than a 4% reduction in sunlight received over the whole year (APSH). The term ‘annual probable sunlight hours’ refers to the long-term average of the total of hours during a year in which direct sunlight reaches the unobstructed ground (when clouds are taken into account). The ‘winter probable sunlight hours’ is used to mean the same but only for the winter period (21 September – 21 March). Note that the BRE guidance expects the above to be met for living room windows only. Overshadowing Sunlight to Amenity Spaces Open spaces should retain a reasonable amount of sunlight throughout the year. The BRE states that for an amenity space to “appear adequately sunlit throughout the year, at least half of the area should receive at least 2 hours of sunlight on 21 March”. Where this is not achieved, the difference between the area achieving 2 hours of sun on 21 March should be no less than 0.8 times its former value. Daylight, Sunlight and Overshadowing Daylight Assessment A total of 28 windows from buildings surrounding the proposed development were highlighted as being in close proximity to, and facing the proposed development. These buildings include: • 790 Tottenham High Road - property to the south-west of the site (windows no. A1-A12) • 794 Tottenham High Street - property to the west of the site (windows no. B1-B10) • 796 Tottenham High Street - property to the west of the site (windows no. C1-C6). The daylight analysis follows for each building individually on the following pages of the report. Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing 790 Tottenham High Road This building has 12 windows facing the proposed development. These windows are located on the rear of the building between ground floor and second floor. The image to the right shows their location. The analysis showed that the windows on ground and first floor did not meet the 25° test, but were found to achieve very good VSCs with the proposed development in place. The detailed results of the analysis are shown in the appendix. Therefore, the proposed development is not anticipated to have any impact on the daylight received by all windows at 790 Tottenham High Road, to the south-west of the proposed site. A12 A4 A1 Assessed windows at the rear of 790 Tottenham High Road 25 degree line from the ground floor windows at 790 Tottenham High Road highlighted in orange (proposed building highlighted in blue) Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing 794 Tottenham High Road This building has ten windows facing the proposed development. These are shown in the image to the right. Three windows achieved VSCs higher than 27% and another three windows passed the relative VSC test. One of the four windows that do not achieve the recommended VSCs, most likely serves a corridor where daylight requirement is lower and the remaining three windows belong to the same room and achieve good VSCs for an urban environment, which indicates that this room will be adequately daylit. Overall, the proposed development is not considered to compromise the daylight received by these ten windows at 794 Tottenham High Road, taking into account the unfavourable location of the ground floor window. B10 B8 B4 B9 B5 B1 Assessed windows at the rear of 794 Tottenham High Road 25 degree line from the ground floor windows at 794 Tottenham High Road highlighted in orange (proposed building highlighted in blue) Northern Terrace Phase 1 - Paxton Development Daylight, Sunlight and Overshadowing 796 Tottenham High Road C1 This building has six windows on the rear of the building facing the proposed development. These are shown in the images below and to the right. C2 The analysis showed that although the windows did not meet the 25° test, four of the six windows were found to achieve very good VSCs with the proposed development in place. The remaining two windows that did not achieve the required VSCs are part of the rear extension. This room is most likely serving a dual aspect and the window on the other aspect which would be much less affected as it is not facing the development directly. Therefore, the proposed development was not found to have any impact on daylight received by this building. The detailed results of the analysis are shown in the appendix. Assessed windows at the rear of 796 Tottenham High Road (extension highlighted in dark blue) C6 C4 C5 C3 2 windows on the extension 25 degree line from the ground floor windows at 796 Tottenham High Road highlighted in orange (proposed building highlighted in blue) Northern Terrace Phase 1 - Paxton Development 10 Daylight, Sunlight and Overshadowing Daylight Results summary The table below summarises the findings of the daylight analysis. It can be seen that the development does not result in any significant impact on the neighbouring windows assessed in detail. Considering the overall site context, it can be concluded that the impact of the development is minimal and well within acceptable limits. Total number of windows tested Number of windows passing the 25 degree plane test Number of windows with a VSC greater then 27% Number of windows that have a VSC of at least 80% of existing value Windows that do not meet any of the above criteria but are dual aspect Windows that serve a corridor where daylight expectation is low Windows that serve the same room and have good VSCs which results in good daylight levels Windows that do not meet any of the above criteria Northern Terrace Phase 1 - Paxton Development 28 4 14 4 2 1 3 0 11 Daylight, Sunlight and Overshadowing Sunlight Assessment Sunlight Access Assessment The BRE guide states that “if a living room of an existing dwelling has a main window facing within 90o of due south, and any part of a new development subtends an angle of more than 25o to the horizontal measured from the centre of the window in a vertical section perpendicular to the window, then the sunlighting of the existing dwelling may be ly affected” A total of 24 windows from buildings surrounding the site were highlighted as facing the development and within 90o of due south. These windows belong to properties included within this assessment. The analysis indicated that all windows apart from two, within 90° due south, satisfy the BRE criteria for sunlight. The two windows that do not meet the criteria most likely serve a dual aspect room. The window on the other aspect was found to achieve good levels of sunlight access. The table below shows the results summary. The detailed results can be found in the appendix. Therefore, the proposed development is not considered to have any impact on sunlight access to windows of surrounding developments. Summary of Sunlight Results for Surrounding Windows Total number of windows facing south Number of windows passing the 25 degree plane test Number of south facing windows with APSH greater than 25% & WPSH greater than 5% or of at least 80% of their former value Number of windows with less than 4% annual reduction in APSH Windows that belong to dual aspect room which will receive good levels of sunlight from the other aspect Windows that do not meet any of the above criteria Northern Terrace Phase 1 - Paxton Development 24 4 18 0 2 0 12 Daylight, Sunlight and Overshadowing Overshadowing Assessment An assessment of the sunlight levels of the surrounding amenity spaces that are in close proximity to the proposed development and may be overshadowed by the new building was undertaken. BRE Guidance suggests that the test should be run on 21 March which is the midpoint between the summer and winter solstices (equinox). At least half of each of the amenity areas should receive no less than 2 hours on 21 March. Where this is not achieved, a relative test should be carried out to show the are receiving 2 hours of sunlight is no less than 80% of its previous value. A solar access analysis was undertaken on the closest open space to the north of the proposed development, as a worst-case approach. The image below shows that this amenity space to the north of the site is predicted to receive a minimum of two hours of sunlight on 21st of March over more than 50% of its area meeeting the target recommended in the BRE guide. The anaylsis result demonstrates that the outdoor space will receive satisfactory levels of sunlight access throughout the year. Potential open area on the north of the proposed site. Shadows plotted between 11:00-14:00 on the 21st of March. Northern Terrace Phase 1 - Paxton Development 13 Daylight, Sunlight and Overshadowing Conclusion The daylight, sunlight and overshadowing analysis indicates that there will not be a significant impact on surrounding properties arising from the proposed Paxton development. Daylight Assessment A total of 28 windows from buildings surrounding the site were highlighted as being in close proximity to, and facing the proposed development. Daylighting levels for potentially affected windows of surrounding developments by the proposed development were found to be acceptable. In summary, • 4 out of 28 windows passed the 25 degree line test; • 14 of the remaining 24 windows achieved a VSC of greater than 27%; • 4 windows achieved relative VSCs over 0.8 of their former value • Two of the remaining six windows are most likely to serve a dual aspect room, indicating sufficient daylight received by this room. • One of the remaining four windows is most likely to serve a corridor space where daylight expectation is low. • The remaining three windows serve the same room which is expected to result in good levels of daylight. windows apart from two, satisfied the BRE criteria for annual probable sunlight hours (APSH) and winter probable sunlight hours (WPSH). The remaining two windows were found to serve a dual aspect room where the window on the other aspect is performing well. Therefore, the proposed development is not considered to have any impact on sunlight access to windows of surrounding developments. Overshadowing Assessment One open spaces was identified to be in close proximity to the proposed development, and has been included in the overshadowing assessment. All the assessed space receives at least 2 hours or more of sunlight on 21 March on at least 50% of its area under the proposed site condition. Therefore, the proposed development does not have a significant impact on sunlight access to the existing amenity space. Overall, the development is not anticipated to have any impact on the daylight received by neighbouring properties. Sunlight Assessment A total of 24 windows from buildings surrounding the site were assessed for sunlight access. The analysis indicated that 4 of the 24 windows passed the 25 degree line test. All of the remaining 20 Northern Terrace Phase 1 - Paxton Development 14 Daylight, Sunlight and Overshadowing Appendix - Detailed results Daylight Assessment Window no. 25 degree plane test VSC tests Comments Proposed VSC >27% ? Existing VSC (%) Relative VSC >80% ? 25.2% 30.1% 83.7% A2 - - A3 - - - - - - A6 - - A7 - - A8 - - - - - - - - - - - A12 - - - B1 10.4% 14.3% 73.0% B2 21.8% 32.8% 66.6% B3 23.5% 32.2% 73.0% Good VSCs achieved by the windows for urban environment. All windows serve the same room which would result in good daylight 21.9% 31.8% 68.9% This window most likely serves a corridor 25.3% 29.0% 87.1% - - A1 A4 A5 Further Testing Required A9 A10 A11 PASS B4 B5 B6 Further Testing Required B7 >27.0% >27.0% Good Levels of Daylight - - B8 27.0% 33.6% 80.2% B9 20.3% 23.7% 85.8% B10 >27.0% - - Good Levels of Daylight C1 13.6% 32.4% 41.9% 13.3% 32.8% 40.5% These windows serve a dual aspect room indicating that sufficient daylight would be received by the room. - - - - - - - - C2 C3 C4 C5 Further Testing Required >27.0% C6 Northern Terrace Phase 1 - Paxton Development Good Levels of Daylight Good Levels of Daylight 15 Daylight, Sunlight and Overshadowing Sunlight Assessment Window 25 degree no. plane test APSH test WPSH test Total % reduction < 4% ? Proposed APSH > 25% ? Existing APSH (%) Relative APSH>80% ? Proposed WPSH >5% ? Existing WPSH (%) Relative WPSH >80% ? A1 40.0% - - 11.4% - - - A2 40.3% - - 12.8% - - - 43.4% - - 13.5% - - - 37.7% - - 12.3% - - - 40.2% - - 11.4% - - - A6 46.3% - - 13.7% - - - A7 47.1% - - 13.5% - - - A8 45.9% - - 12.0% - - - A9 - - - - - - - - - - - - - - - - - - - - - A12 - - - - - - - B2 26.6% - - 8.8% - - - B4 26.2% - - 10.9% - - - B6 33.5% - - 10.5% - - - B8 29.6% - - 9.2% - - - A3 A4 A5 A10 A11 Further Testing Required PASS B9 38.8% - - 12.1% - - - B10 33.3% - - 9.0% - - - C1 19.1% 46.0% 41.5% 6.1% - - - C2 19.8% 46.5% 42.7% 6.5% - - - C3 33.5% - - 7.4% - - - C4 26.2% - - 7.9% - - - C5 38.0% - - 10.0% - - - C6 32.8% - - 11.1% - - - Northern Terrace Phase 1 - Paxton Development Comments Good sunlight levels Serves a dual aspect room where the window on the other aspect is performing well. Good sunlight levels 16
© Copyright 2026 Paperzz