MSP80D www.muesentechnik.de Monocrystalline silicon smart differential pressure transmitter MSP80D High stability, low static pressure MSP80D smart differential pressure transmitter uses monocrystalline silicon sensor chip and world's original design of monocrystalline silicon suspension that made of advanced MEMS technology. So it achieves the world's leading overpressure performance and also ensures excellent signal stability. Built-in manometry capsule and signal processing module that are imported from Germany achieve the perfect combination of static pressure and temperature compensation, which provides high measurement accuracy and stability under a wide range of static pressure and temperature. ® MSP80D smart differential pressure (flow) transmitter can measure differential pressure accurately and convert it into DC 4 ~ 20mA output signal. This transmitter can be operated through three buttons locally or through universal communicator or configuration software remotely. Without affecting the output signal of DC 4 ~ 20mA, it can display and configurate at the same time. Detailed Information www.muesentechnik.de Differential pressure transmitter Application the flow of gas, vapor and liquid measurement with device (volume or mass flow) Measurement of level, volume and mass Differential pressure monitoring Through a number of international certifications, widely used Powerful instruments for process pressure High stability Low static pressure Long term stability Worldwide support and service Benefits High accuracy Differential pressure (flow) transmitter can measure high accurately in the 0.5 ~ 500kPa measuring range. The accuracy of standard calibration range: ±0.05% Positive and negative zero shift, without adjusting linearity Excellent static pressure speciality within a small range overpressure of 1kPa nominal range chip: 1.5MPa (1500 times) overpressure of 4kPa nominal range chip: 2.5MPa (625 times) Without central diaphragm, simplify the structure, improve the accuracy and the stability Excellent suitability of environment The intelligent static pressure and temperature compensation protect transmitter from the effects of temperature, static pressure and overpressure, so that the consolidated measurement error will be kept to the minimum. Flexible range of compression M1,M2 Range ratio: 20:1 M3 Range ratio: 40:1 M4,M5,M6 Range ratio: 100:1 Excellent operability & convenient to use ▪ Five-digit LCD with backlight ▪ View of units (Pa, kPa, MPa, bar, mbar, %, psi, mmH2o) ▪ Quickly adjusted through built-in three buttons ▪ A variety of corrosion-resistant materials ▪ Comprehensive self-diagnosis function 1 MSP80D www.muesentechnik.de Specifications Functional specifications Performance specifications ▪ Testing fluid : liquid, gas, vapor ▪ Measuring range : ▪ Accuracy : range/ scope M1 M2 M3 M4 M5 M6 kPa sensor cell inH2o mbar M1,M2,M3, M4,M5,M6 mmH2o range 0.5~10 2~40 5~100 50~1000 scope -10~10 -40~40 -100~100 -1000~1000 range 1~20 4~80 10~200 100~2000 scope -20~20 -80~80 -200~200 -2000~2000 range 1~40 4~160 10~400 100~4000 scope -40~40 -160~160 -400~400 -4000~4000 range 1~100 4~400 10~1000 100~10000 scope -100~100 -400~400 -1000~1000 -10000~10000 range 2~200 8~800 20~2000 200~20000 scope -200~200 -800~800 -2000~2000 -20000~20000 range 5~500 20~2000 50~5000 500~50000 scope -500~500 -2000~2000 -5000~5000 -50000~50000 Note: wetted material working pressure M1 M2 M3 M4 M5 M6 01, 02, 03, 04, 05 01, 02, 03, 04, 05 01, 02, 03, 04, 05 01, 02, 03, 04, 05 01, 02, 03, 04, 05 01, 02, 03, 04, 05 25MPa 25MPa 25MPa 25MPa 25MPa 25MPa code of sensor cell & wetted material refers to the code table DC4~20mA+HART ▪ Output signal : ▪ Allowable load resistance : 0~600Ω (DC 24V) Note: when communicates with the handheld communicator, you need a standard (250Ω) load resistance ▪ Power supply : general situation DC10.5~45V intrinsically safe explosion-proof DC10.5~26V ▪ Communication line condition : Length of line: max 2km (When 0.75~1.25mm2 control instrument cable exceeds 1 km, you should use twisted pair cable) load resistance : 250~600Ω (DC 24V, include cable resistance) load capacity : under 0.55mF load inductance : under 3.3mH Spacing above power line : above 15cm (Please avoid parallel wiring) upper limit 20.8mA ▪ Saturation current : lower limit 3.8mA upper limit 22.8mA ▪ Alarm current : lower limit 3.6mA (Mode can be set) The zero & full span point can be operated ▪ Adjustment function : through three buttons from the top of the housing or through configuration software remotely. ▪ Environmental temperature : -40 ~ +85℃ (With filling fluorine oil : -10~+60℃ ) -40~+90℃ ▪ Storage temperature : DIN40040GPC ▪ Weatherability : ▪ EMC applicable standard : EN1326-1: 2006 ▪ TD>15:1 =±(0.0015×TD+0.05)% *TD- range ratio ▪ square-root output precision: output precision same as reference precision ≥ 50% 50%~drop point reference precision×50 square-root output (%) ▪ Effect of environmental temperature : The total amount of effect/28℃ (50°F) sensor cell effect M1,M2,M3 ±[0.08%range+0.015%upper limit of range] M4,M5,M6 ±[0.08%range+0.03%upper limit of range] ▪ Effect of static pressure : ▪ Static pressure : sensor cell reference precision =±0.05% ▪ TD1:1...TD15 :1 sensor cell M1,M2,M3 M4,M5,M6 effect ±[0.05%range]/10MPa ±[0.05%range]/10MPa ▪ Effect of overpressure : ±0.05%upper limit of range/10MPa ▪ Stability : sensor cell M1,M2,M3 M4,M5,M6 effect ±0.05%upper limit of range/year ±0.05%upper limit of range/year ▪ Effect of Power supply : ±0.005%/1V ▪ Effect of Mounting position : The changes of mounting position in the direction parallel to the diaphragm will not cause zero - drift effects. If the changes between the mounting position and the diaphragm is more than 90°, which can be corrected through zeroing corrected within the range of 0.4KPa. 90ms ▪ Response time : The time constant can be adjusted from 0 to ▪ Damping : 99.9 seconds. can be adjusted from 0 to 160 uA ▪ Filter constant : ▪ Self-stabilization coefficient : can be adjusted from 0 to 2% 600 Load resistance R (Ω) Communicated scope HART 250 10.5 16.4 24.7 45 Supply voltage DC (V) Diagram of supply voltage and external load 2 MSP80D www.muesentechnik.de Structure material ▪ wetted material: code of material 01 02 03 04 05 Electrical connection diagram refers to the code table detecting part isolated diaphragm installed plywood SUS316L SUS316 SUS316 Hastelloy C-276 SUS316 Tantalum SUS316 SUS316L Gold plating Hastelloy C Hastelloy C-276 ▪ Wetted sealing ring : fluororubber, chemigum ▪ Housing of transmitter: low copper aluminum die casting + polyurethane coating ▪ Cover of transmitter : aluminum casting + polyurethane coating IP67 ▪ Ingress protection : SUS304 ▪ Nameplate: silicon oil & fluorocarbon oil (optional) ▪ Filling oil : according to outline ▪ Size : about 2.2~2.7kg (noumenon) ▪ Weight : G1/2,1/2-14NPT,M20×1.5 ▪ Cable intake : M3 bolt ▪ External terminal : ▪ Process connection port : Rc1/4 or 1/4 -18NPT U-type mounted on 50mm (2▪ Installation : inch) pipe, or on the wall (depend on the model specification) Dimensional drawing of outline Shell Internal grounding wire Power supply signal (4...20)mA Testing signal External grounding wire 3 MSP80D www.muesentechnik.de Model and specification code table Type Specifications code MSP80D · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ··· Output signal H · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Range ( sensor cell) M1 M2 M3 M4 M5 M6 Wetted material ·················································· ·················································· ·················································· ·················································· ·················································· ·················································· 01 02 03 04 05 99 Filling oil ················································ ················································ ················································ ················································ ················································ ················································ 01 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 02 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 99 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 01 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 02 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 99 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Process connection Explanation Monocrystalline silicon differential pressure transmitter 4~20mA, HART digital communication protocol range:0.5~10kPa range:1~20kPa range:1~40kPa range:1~100kPa range:2~200kPa range:5~500kPa isolation diaphragm : SUS316L isolation diaphragm : hastelloy C-276 isolation diaphragm : Tantalum isolation diaphragm : SUS316L gold planting isolation diaphragm : hastelloy C -276 other requirements silicon oil fluorocarbon oil other requirements female thread , 1/4” - 18NPT female thread , 1/2” - 14NPT other requirements 01 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 02 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 99 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · fluororubber chemigum other requirements Electrical connection 01 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 99 · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · M20x1.5 other requirements Display header D · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·· N · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·· Sealing ring 2-inch pipe v bracket H ······························ V ······························ O ······························ Additional code of type selection *Reference type:MSP80D-H-M1-01-01-01-01-01-D-H overpressure:2MPa overpressure:3.5MPa overpressure:3.5MPa overpressure:7MPa overpressure:7MPa overpressure:7MPa with LCD nothing flat bracket right angle bracket nothing Type selection specification plywood : SUS304 plywood : SUS316 plywood : SUS316 plywood : SUS316 plywood : hastelloy C 4 MSP80D www.muesentechnik.de Additional specifications (explosion- proof) Projeckts Explanation NEPSI flame-proof and dust explosion-proof approval : Applicable standard : GB3836.1-2010 GB3836.2-2010 d Ⅱ CT6 ; DIP A21T T6 A T6 : maximum permissible surface temperature 85℃ Environmental termperature : -40~60℃ Chinese standard Electrical interface : 1/2NPT female thread , G1/2 female thread , M20 female thread NEPSI NEPSI intrinsic safety and dust explosion-proof approval : Applicable standard : GB3836.1-2010 GB3836.4-2010 ia Ⅱ CT6 ; DIP A20T T6 A T6 : maximum permissible surface temperature 85℃ Environmental termperature : -40~60℃ FM flame-proof approval Applicable standard : FM3600 , FM3615 , FM3810 , ANSI/NEMA250 Flame-proof : Ⅰ rating , 1 district , B , C , D group Flame-proof burning : Ⅱ / Ⅲ rating , 1district , E , F , G group Hazardous locations : Indoor and outdoor ( NEMA4X ) T6 : environmental termperature : -40~60℃ Electrical interface : 1/2NPT female thread FM intrinsic safety approval Certification of Applicable standard : FM3600 , FM3610 , FM3611 , FM3810 , ANSI/NEMA250 factory Intrinsic safety : Ⅰ rating , 1 district , A , B , C , D group ; Ⅱ rating,1district , E , F , G group and Ⅲ rating , 1district hazardous locations federation Non combustibla : Ⅰ rating , 2 district , A , B , C , D group Ⅱ rating , 1 district , E , F , G group and Ⅲ rating , 1 district hazardous locations ( FM ) seal : NEMA 4X Termperature rating : T4 Environmental termperature : -40~60℃ Electrical interface : 1/2NPT female thread FM flame retardant approval Ⅰ rating , 2district , A , B , C , D group , Termperature rating T4 , Type 4X Ⅱ rating , 2 district , F , G group , Termperature rating T4 , Type 4X Ⅲ rating , 2 district , Termperature rating T4 , Type 4X European Community (EC) (ATEX) Code ND1 NX1 FD1 FX1 FX2 CENELEC (KEMA) flame-proof approval : Applicable standard : EN60079-0,EN60079-1 Identification : KEMA 02ATEX2148 Ⅱ 2G Ex d Ⅱ C T4 , T5 , T6 Environmental termperature : T5 : -40~80℃ ;T4andT6 : -40~75℃ The highest wetted temperature : T4:120 ℃ T5:100 ℃ T6:85 ℃ Electrical interface : 1/2NPT female thread,M20 female thread AD1 CENELEC (KEMA) intrinsic safety approval : Applicable standard : EN50014,EN50020,EN50284 Identification : KEMA 02ATEX1030X Ⅱ 1G Eex ia Ⅱ C T4; Environmental termperature : -40~60℃ ; Electrical interface : 1/2NPT female thread , M20 female thread AX1 Including KF21,KS2 and N (non-sparking) approval : Applicable standard : EN 60079-0 : 2009 , E,60079-15 : 2005 Ⅱ 3G Ex nl Ⅱ C T4 ; Environmental termperature : -30~60℃ ; Electrical interface: 1/2NPT female thread , PG13.5 female thread , M20 female thread AX2 CENELEC ATEX Type n approval : Applicable standard : EN 60079-0 : 2009 , E,60079-15 : 2005 Ⅱ 3G Ex nl Ⅱ C T4 ; Environmental termperature : -30~60℃ Muesen Technik GmbH Produktionsadresse: Wilhelm-Gutbrod-Straße 19 60437 Frankfurt am Main, Germany Telefon: Telefax: Email: Internet: +49 (0)69 9050 5554 +49 (0)69 5098 3597 [email protected] www.muesentechnik.de AX3 5
© Copyright 2026 Paperzz