Technical Note KSch, 2014-01-27 P736T0001, valid for PD73Z2xxW PD73Z2xxW PInano® Piezo Scanner Systems Contents System Description ............................................................................................................ 2 Possible System Components ......................................................................................................2 Available PInano® Piezo Scanner Systems ..................................................................................2 Accessory .....................................................................................................................................3 Symbols and Typographic Conventions .......................................................................... 3 Other Applicable Documents ............................................................................................ 4 Intended Use ....................................................................................................................... 4 Safety Precautions ............................................................................................................. 5 Product Description ........................................................................................................... 6 Product View.................................................................................................................................6 Scope of Delivery ..........................................................................................................................6 Installation........................................................................................................................... 7 General Notes on Installation ........................................................................................................7 Connecting the P736.Zxx to a Protective Earth Conductor ..........................................................8 Mounting the P-736.Zxx to the M-687.Ux ......................................................................................9 Mounting a Sample Holder to the P-736.Zxx ...............................................................................11 Start-Up and Operation .................................................................................................... 12 General Notes on Start-Up and Operation ..................................................................................12 Starting Up and Operating the P-736.Zxx ...................................................................................13 Discharging the P-736.Zxx ............................................................................................... 14 Maintenance ...................................................................................................................... 14 Cleaning the P-736.Zxx .................................................................................................... 14 Customer Service ............................................................................................................. 14 Technical Data .................................................................................................................. 15 Dimensions ....................................................................................................................... 17 Maximum Ratings ............................................................................................................. 21 Ambient Conditions and Classifications ........................................................................ 21 Old Equipment Disposal .................................................................................................. 22 EC Declaration of Conformity.......................................................................................... 22 Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 2 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW System Description The PInano® piezo scanner systems are designed for inverse microscopy using microscopes by Nikon and Olympus. Each system consists of a P-736.Zxx PInano® Z piezo scanner and an E-709.xRG digital piezo controller. Possible System Components Standard versions of the P-736.Zxx PInano® Z piezo scanner: Model Name P-736.ZCN PInano® Z Piezo Scanner for Inverted Nikon Microscopes, 220 µm, Well Plate Size Aperture, Capacitive Sensors P-736.ZRN PInano® Z Piezo Scanner for Inverted Nikon Microscopes, 220 µm, Well Plate Size Aperture, Piezoresistive Sensors P-736.ZCO PInano® Z Piezo Scanner for Inverted Olympus Microscopes, 220 µm, Well Plate Size Aperture, Capacitive Sensors P-736.ZRO PInano® Z Piezo Scanner for Inverted Olympus Microscopes, 220 µm, Well Plate Size Aperture, Piezoresistive Sensors Standard versions of the E-709.xRG digital piezo controller: Model Name E-709.CRG Digital Piezo Controller, 1 Channel, -30 to 130 V, Capacitive Sensor, Bench-Top E-709.PRG Digital Piezo Controller, 1 Channel, -30 to 130 V, Piezoresistive Sensor, Bench-Top Available PInano® Piezo Scanner Systems The following PInano® piezo scanner systems are available as combinations of Z piezo scanner and digital piezo controller: System - Z Piezo Scanner Digital Piezo Controller P-736.ZCN P-736.ZRN P-736.ZCO P-736.ZRO E-709.CRG E-709.PRG PD73Z2CNW x - - - x - PD73Z2RNW - x - - - x PD73Z2COW - - x - x - PD73Z2ROW - - - x - x Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 3 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Accessory The P-736.Zxx PInano® Z piezo scanners can be mounted to the M-687.UN and M-687.UO XY microscope stages or any other suitable mounting surface, which is mounted to a corresponding microscope. The Z piezo scanners can be mounted, among others, to the following M-687.Ux XY microscope stages: P-736.Zxx model M-687.UN M-687.UO P-736.ZCN x - P-736.ZRN x - P-736.ZCO - x P-736.ZRO - x To position slides or petri dishes PI offers a microscope universal holder. Order Number Description M-687.AP1 Microscope Universal Holder for Slides and Petri Dishes for PI Stages with 160 mm × 110 mm Free Aperture Other inserts are available on request. Symbols and Typographic Conventions The following symbols and typographic conventions are used in this Technical Note: CAUTION Dangerous situation If not avoided, the dangerous situation will result in minor injury. Actions to take to avoid the situation. NOTICE Dangerous situation If not avoided, the dangerous situation will result in damage to the equipment. Actions to take to avoid the situation. INFORMATION Information for easier handling, tricks, tips, etc. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 4 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Other Applicable Documents The devices and software tools which are mentioned in this documentation are described in their own manuals. Product Document E-709 Digital Piezo Controller PZ222E User Manual E-709 Digital Piezo Controller for Capacitive Sensors E700T0003 Technical Note M-687.UN XY Microscope Stage for Inverted Nikon Microscopes MP100E User Manual M-687.UO XY Microscope Stage for Inverted Olympus Microscopes MP107E User Manual Intended Use The P-736.Zxx PInano® Z piezo scanners and the E-709.xRG digital piezo controllers are laboratory devices as defined by DIN EN 61010-1. They are intended to be used in interior spaces and in an environment which is free of dirt, oil and lubricants. Based on their design and realization, the Z piezo scanners are intended to position in Z direction. They are designed to position a sample holder with suitable dimensions, as for example the M-687.AP1 sample holder that can carry a slide or a petri dish. The Z piezo scanners can carry a maximum load of 0.5 kg. They are intended to be used with M-687.Ux XY microscope stages or with other suitable microscope stages. The Z piezo scanners are to be mounted horizontally. The intended use of the Z piezo scanners is only possible in combination with the E-709.xRG digital piezo controllers. The E-709.xRG controllers provide the required operating voltages. To ensure proper performance of the servo-control system, the electronics are able to read out and process the signals from the capacitive or piezoresistive sensors. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 5 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Safety Precautions CAUTION Dangerous voltage and residual charge on piezo actuators! The P-736.Zxx is driven by piezo actuators. Temperature changes and compressive stresses can induce charges in piezo actuators. After being disconnected from the electronics, piezo actuators can also stay charged for several hours. Touching or short-circuiting the contacts in the connector of the P-736.Zxx can lead to minor injuries. In addition, the piezo actuators can be destroyed by an abrupt contraction. Do not open the P-736.Zxx. Discharge the piezo actuators before installation: Connect the piezo actuator to the switched-off PI controller. Do not pull out the connector from the electronics during operation. For piezo actuators with sub-D connector: Touching the contacts in the connector can lead to an electric shock (max. 130 V DC) and minor injuries. Do not touch the contacts in the connector. Secure the connector of the piezo actuator with screws against being pulled out of the controller. CAUTION Risk of electric shock if the protective earth conductor is not connected! If a protective earth conductor is not or not properly connected, dangerous touch voltages can occur and there is a risk of electric shock. In the case of malfunction or failure of the system, touching the P-736.Zxx can result in minor injuries. Connect the P-736.Zxx to a protective earth conductor before start-up. Do not remove the protective earth conductor during operation. Use electrically conductive materials (e.g. screws and flat washers) for mounting the protective earth conductor. Make sure that the contact resistance is < 0.1 ohm at 25 A at all connection points relevant for mounting the protective earth conductor. If the protective earth conductor has to be temporarily removed (e.g. for modifications), reconnect the P-736.Zxx to the protective earth conductor before starting it up again. NOTICE Unsuitable cables! Unsuitable cables can damage the electronics. Only use cables from PI for connecting the P-736.Zxx to the electronics. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 6 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW INFORMATION Extended cables can affect the performance of the P-736.Zxx. Do not use cable extensions. If you need longer cables, contact our customer service department (p. 14). Product Description Product View Figure 1: P-736.ZCO as example 1 4 x M3 mounting holes for mounting a sample holder as for example the M-687.AP1 2 Movable platform 3 Cable exit 4 3 x counterbore holes for M4 screws for mounting the P-736.Zxx to a M-687.Uxx XY stage 5 Base body Scope of Delivery A PInano® piezo scanner system is delivered with the following components. Order Number Component P-736.Zxx PInano® Z piezo scanner according to order E-709.xRG Digital piezo controller according to order C-663.PS Wide-range 24-V power supply, 42 W 3763 Line cord 000036360 USB cable (3 m, USB-A (m)/USB Mini-B (m)) for PC connection Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 7 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Order Number Component E709B0002 RS-232 adapter HD sub-D 26 (m) to sub-D 9 (m) for PC connection via RS-232 C-815.34 Null-modem cable for PC connection via RS-232 E-709.04 Adapter cable for analog I/O (1m, HD sub-D 26 / 2 x BNC) 000036450 M4 screw set for protective earth connection Documentation, consisting of: P736T0001 Technical note for PD73Z2xxW PInano® piezo scanner systems (this document in printed form) PZ222E User manual for E-709 digital piezo controllers E-709.CD CD with PC software and documentation of the E-709 digital piezo controller A000T0032 Technical note on updating the PI Software using the PI Update Finder A000T0028 Technical note on using the PI Update Finder Only PD73Z2CxW: Technical note for E-709.CRG, CHG, CR E709T0003 Packaging materials Installation General Notes on Installation NOTICE Appropriate torque required! Specifications are only achieved if a minimum torque is observed when mounting the stage to the M-687.Ux or any other suitable microscope stage. A torque too high can cause damage to the stage. To ensure that specifications are achieved and to avoid damage to the stage observe a torque range of 250 Ncm to 270 Ncm when you mount the stage to the M-687.Ux or any other suitable microscope stage using the 3 M4 screws. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 8 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW NOTICE Unallowable forces on movable platform! Executing a push force >50 N or a pull force >30 N on the movable platform can damage the stage and render the mechanical design inoperable. Ensure that only a maximum push force of 50 N or a maximum pull force of 30 N is executed on the movable platform. NOTICE Lubricants, dirt, condensation! Dirt, oil, lubricants and condensation will render the motor/drive inoperable. Ensure that the piezo actuators of the P-736.Zxx do not come into contact with lubricants. Keep the P-736.Zxx free from dirt and condensation. Connecting the P736.Zxx to a Protective Earth Conductor NOTICE Ground loops with double connection of protective earth conductor! In the case of P736.Zxx models with sub-D connectors, ground loops can occur when the P736.Zxx is grounded via its protective earth connection or the mounting holes as well as by the shield of the connection cable for the electronics. If a ground loop occurs, contact our customer service department. INFORMATION Observe the applicable standards for mounting the protective earth conductor. The P736.Zxx features a separate protective earth connection. Figure 2: Example of a protective earth connection Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 9 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Tools and accessories Suitable protective earth conductor: Cross-sectional area of the cable ≥0.75 mm2 Suitable screwdriver M4 CE screws for connecting the protective earth conductor Connecting the protective earth conductor to the separate protective earth connection Figure 3: Recommended mounting of the protective earth conductor (profile view) 1 Case of the P-736.Zxx 2 Flat washer 3 Safety washer 4 Screw 5 Cable lug 6 Protective earth conductor 1. If necessary, fasten a suitable cable lug to the protective earth conductor. 2. Fasten the cable lug of the protective earth conductor to the M4 screw on the protective earth connection of the P736.Zxx as shown in the profile view. 3. Tighten the M4 screw with at least three rotations and a torque of 1.2 Nm to 1.5 Nm. Mounting the P-736.Zxx to the M-687.Ux Prerequisite You have read and understood the General Notes on Installation (p. 7). Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 10 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Tools and accessories 3 socket head screws per P-736.Zxx model (included with the P-736.Zxx model) P-736.Zxx model Suitable screws P-736.ZCN (part of PD73Z2CNW system) M4x10 P-736.ZRN (part of PD73Z2RNW system) M4x10 P-736.ZCO (part of PD73Z2COW system) M4x14 P-736.ZRO (part of PD73Z2ROW system) M4x14 Suitable screwdriver Mounting the P-736.ZxN to the M-687.UN INFORMATION The upper moving platform of the M687.UN features an adapter plate which has to be removed before mounting the P-736.ZRN or P-736.ZCN PInano® Z piezo scanners on the M687.UN. Figure 4: Fixing screws of the adapter plate of the M-687.UN 1. Loosen the three M4 fixing screws of the adapter plate. 2. Remove the three M4 fixing screws of the adapter plate. 3. Remove the adapter plate. 4. Mount the P-736.ZxN on the M687.UN using three M4x10 screws observing a torque range of 250 to 270 Ncm. For mounting, use the threaded holes where the adapter plate was affixed. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 11 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Mounting the P-736.ZxO to the M-687.UO Figure 5: M-687.UO: Threaded holes in the upper platform (black arrows = 3 x M4) 1. Choose the mounting position so that the three M4 holes in the upper platform (Y axis; see arrows in the figure) can be used for affixing the P-736.ZxO. 2. Mount the P-736.ZxO with three screws M4x14 to the threaded holes observing a torque range of 250 to 270 Ncm; see "Dimensions" in the MP107E user manual for M-687.UO. Mounting a Sample Holder to the P-736.Zxx Prerequisite You have read and understood the “General Notes on Installation” (p. 7). Tools and accessories Sample holder of suitable dimensions as, for example, M-687.AP1 Suitable screwdriver 4 x M3x4 screws per P-736.Zxx model (included with the M-687.AP1 model) Mounting a sample holder to the P-736.Zxx Only mount the sample holder to the P-736.Zxx using the four mounting holes for M3 screws intended for this purpose (see Figure 6). Optional, when an M-687.AP1 sample holder is used: The sample holder can be snapped in place and held in place by the retaining spring of the sample holder Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 12 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Figure 6: Dimensions of a P-736.Zxx; a sample holder, as for example the M-687.AP1, is to be fastened to the P-736.Zxx using the mounting holes marked by the grey arrows Start-Up and Operation General Notes on Start-Up and Operation NOTICE Destruction of the piezo actuator by electric flashovers! The use of the P-736.Zxx in environments that increase the electrical conductivity can lead to the destruction of the piezo actuator by electric flashovers. Electric flashovers can be caused by moisture, high humidity, liquids and conductive materials such as metal dust. In addition, electric flashovers can also occur in certain air pressure ranges due to the increased conductivity of the air. Avoid operating the P-736.Zxx in environments that can increase the electric conductivity. Only operate the P-736.Zxx within the permissible ambient conditions and classifications (p. 21). Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 13 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW NOTICE Destruction of the piezo actuator by continuously high voltage! The constant application of high voltage to piezo actuators can lead to leakage currents and flashovers that destroy the ceramic. If the P-736.Zxx is not used, but the controller is to remain switched on to ensure temperature stability: Set the piezo voltage to 0 V on the controller. NOTICE Uncontrolled oscillation! Oscillations can cause irreparable damage to the P-736.Zxx. Oscillations are indicated by a humming and can result from the following causes: The load and/or dynamics of operation differ too much from the calibration settings. The P-736.Zxx is operated near its resonant frequency. If you notice oscillations, stop the P-736.Zxx immediately. Starting Up and Operating the P-736.Zxx INFORMATION Systems are calibrated at the factory to achieve optimum performance. Replacing the system components will cause a loss in performance. Note the assignment of the stage axes to the controller channels which is given by the calibration label of the piezo servo controller. If the piezo servo controller or the stage has to be replaced, recalibrate the axis displacement (see controller manual) or contact our customer service department (p. 14). Prerequisite You have read and understood the following sections: Safety Precautions (p. 5) General Notes on Start-Up and Operation (p. 12) Starting up and operating the P-736.Zxx Follow the instructions in the manual of the used piezo controller for start-up and operation of the P-736.Zxx. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 14 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Discharging the P-736.Zxx The P-736.Zxx must be discharged before demounting. Demounting is necessary e.g. before cleaning or transporting the P-736.Zxx as well as for modifications Discharging an P-736.Zxx that is connected to the controller Set the piezo voltage to 0 V on the controller. Discharging an P-736.Zxx that is not connected to the controller Connect the Z piezo scanner to the switched-off PI controller for 10 seconds. Maintenance NOTICE Misalignment from manipulating Z piezo scanner! The P-736.Zxx is maintenance-free and precisely aligned. Do not try to manipulate or to open the P-736.Zxx. Cleaning the P-736.Zxx Prerequisites You have discharged the piezo actuators of the P-736.Zxx. You have disconnected the P-736.Zxx from the controller. Cleaning the P-736.Zxx Clean the surface of the P-736.Zxx with a towel that is only lightly dampened with a mild cleanser or disinfectant, with alcohol or with isopropanol. Do not do any ultrasonic cleaning. Customer Service For inquiries and orders, contact your PI sales engineer or send us an e-mail ([email protected]). If you have questions concerning your system, have the following information ready: Product codes and serial numbers of all products in the system Firmware version of the controller (if present) Version of the driver or the software (if present) Operating system on the PC (if present) The latest versions of the relevant user manuals for your system are available for download on our website (http://www.pi.ws). Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 15 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Technical Data PD73Z2ROW / PD73Z2RNW PD73Z2COW / PD73Z2CNW Lower cost system with P-736.ZRO stage for Olympus microscopes / P-736.ZRN stage for Nikon microscopes Higher precision system with P-736.ZCO stage for Olympus microscopes / P-736.ZCN stage for Nikon microscopes Z Z Integrated sensor Piezoresistive Capacitive Travel (closed-loop) 220 220 µm Resolution (closed-loop) 1 1 nm Resonant frequency (loaded, at 100 g) 250 250 Hz Load capacity 500 500 g PICMA® P-885 PICMA® P-885 Operating temperature range 15 to 40 15 to 40 Material Aluminum Aluminum Mass 850 850 Active axes Unit Tolerance Motion and positioning typ. Mechanical properties max. Drive properties Ceramic type Miscellaneous Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws °C g ±5 % Page 16 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW PD73Z2ROW / PD73Z2RNW PD73Z2COW / PD73Z2CNW Unit Tolerance Cable length 1.5 1.5 m ±10 mm Piezo controller E-709 controller included in delivery Interface / communication USB, RS-232, SPI I/O connector HD Sub-D 26-pin 1× analog input 0 to10 V 1× sensor monitor 0 to10 V 1× digital input (LVTTL, programmable) 1× analog output 5× digital outputs (LVTTL, 3× predefined, 2× programmable) Command set PI General Command Set (GCS) User software PIMikroMove Software drivers LabVIEW drivers, shared libraries for Windows and Linux. Is supported by MATLAB, MetaMorph, µManager, Andor iQ Supported functionality Wave generator, data recorder, auto zero, trigger I/O, Controller dimensions 160 mm x 96 mm x 33 mm Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 17 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Dimensions Decimal places are separated in commas. Dimensions of P-736.ZCN Figure 7: P-736.ZCN, Note 1: Cable length 1.7 meter, termination is a sub-D7W2 Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 18 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Dimensions of P-736.ZCO Figure 8: P-736.ZCO, Note 1: Cable length 1.7 meter, termination is a sub-D7W2 Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 19 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Dimensions of P-736.ZRN Figure 9: P-736.ZRN, Note 1: Cable length 1.7 meter, termination is 9-pin sub-D Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 20 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Dimensions of P-736.ZRO Figure 10: P-736.ZRO, Note 1: Cable length 1.7 meter, termination is a 9-pin sub-D Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 21 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Maximum Ratings The P-736.Zxx is designed for the following maximum ratings: Maximum operating voltage Maximum operating frequency (unloaded) Maximum power consumption -30 to 130 V 100 Hz 20 W Ambient Conditions and Classifications The following ambient conditions and classifications must be observed for the P-736.Zxx: Area of application For indoor use only Maximum altitude 2000 m Air pressure 1100 hPa to 0.1 hPa (corresponds to roughly 825 torr to 0.075 torr) Relative humidity Highest relative humidity 80% for temperatures up to 31°C Decreasing linearly to 50% relative humidity at 40°C Operating temperature* 15°C to 40°C Storage temperature 0°C to 70°C Transport temperature -25°C to 85°C Overvoltage category II Protection class I Degree of pollution 1 Degree of protection IP20 according to IEC 60529 *Specifications assured from 17°C to 23°C, performance may be reduced outside this range. Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws Page 22 / 22 2014-01-27 P736T0001, valid for PD73Z2xxW Old Equipment Disposal In accordance with the applicable EU law, electrical and electronic equipment may not be disposed of with unsorted municipal wastes in the member states of the EU. When disposing of your old equipment, observe the international, national and local rules and regulations. To meet the manufacturer’s product responsibility with regard to this product, Physik Instrumente (PI) GmbH & Co. KG ensures environmentally correct disposal of old PI equipment that was first put into circulation after 13 August 2005, free of charge. If you have old PI equipment, you can send it postage-free to the following address: Physik Instrumente (PI) GmbH & Co. KG Auf der Römerstr. 1 D-76228 Karlsruhe, Germany EC Declaration of Conformity For the PInano® piezo scanner systems, an EC Declaration of Conformity has been issued in accordance with the following European directives: 2006/95/EC, Low Voltage Directive 2004/108/EC, EMC Directive 2011/65/EU, RoHS Directive The applied standards certifying the conformity are listed below. Electromagnetic Emission: EN 61000-6-3:2007, EN 55011:2009 Electromagnetic Immunity: EN 61000-6-1:2007 Safety (Low Voltage Directive): EN 61010-1:2010 Physik Instrumente (PI ) GmbH & Co. KG_Auf der Roemerstrasse 1_76228 Karlsruhe/Germany Phone +49 721 4846-0, Fax +49 721 4846-1019 E-mail [email protected], www.pi.ws
© Copyright 2026 Paperzz