Linear cylinder diffuser pag. A-74 LC Description Linear rotating cylinder diffuser for ceiling or wall installation. Each slot houses inside a range of cylinders, that, by rotation, allow differents launch configurations. Compared to the traditional linear slot diffuser, it offers more flexibility and best performances. In fact, it’s possible to guarantee comfortable environment’s conditions (absence of air-flows) also in presence of high specific loads, due to the jet splitting (alternate throw), which allows a fast reduction of velocity. Characterized by pressure drops and limited noise levels, thanks to the big versatility, it’s used both for cooling and for heating both for ceiling and for wall. To maintain the aesthetic uniformity, the LFR (LF) linear diffuser can be used in intake. Dimensions Nominal length (L) : 1000, 1500, 2000 mm* Slots’ number (N) : 1, 2, 3, 4 * Different lengths on request (by increments of 100 mm) Construction Extruded anodised aluminium (LC), extruded natural painted aluminium (LCW). Plastic material cylinders. Finish Anodised aluminium, with black cylinders (LC). Gloss white RAL 9010, powder-coated polyester type, with white cylinders (LCW). Specifications Linear rotating cylinder diffuser for ceiling or wall installation. Ceiling diffusion with horizontal launch and alternate throw, with or without Coanda effect. Ceiling diffusion with vertical launch. Wall diffusion. Possibility to rotate cylinders in closing position, in order to partialize the jet. Anodised aluminium or white painted aluminium RAL 9010 and plastic material (cylinders) construction. N 1 2 3 4 qv DP d LWA qv DP d 3 LWA (m /h) (Pa) (m) (dBA) 100 20 0,7 33 150 40 1,8 43 200 75 4,5 50 100 10 0,8 27 200 25 1,6 39 300 50 3,7 46 200 15 0,9 32 300 30 2,0 41 400 50 4,6 47 300 20 1,5 34 400 35 3,5 40 500 50 5,5 45 air flow per meter (L = 1000 mm) pressure drop distance from the wall (hi = 3 m) noise rating (rif. 10-12 W) F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] Accessories PLSA-LC: standard plenum type“A” PLSB-LC: standard plenum type “B” PLSC-LC: standard plenum type “C” PLIA-LC: insulated plenum* type “A” PLIB-LC: insulated plenum* type “B” PLIC-LC: insulated plenum type “C” *internal polyurethane insulation thickness 6mm, cl. 1 N A* B* C D** F*** H (mm) (mm) (mm) (mm) (mm) (mm) 1 35/31 51/31 100 30/37 158 230 2 64/60 80/60 90 59/66 198 270 3 93/89 109/89 70 88/95 198 270 4 122/118 138/118 70 117/124 248 320 * LC / LCSB ** type “A” / type “B” *** external diameter, single inlet for L = 1000 mm, double inlet for L = 1500 mm and L = 2000 mm. C D BF H 43 A B Plenum type “A” 06.06.16 Linear cylinder diffuser LC pag. A-75 Other versions LCSB: like LC but without lateral frame, for plasterboard installation. B-20 For wall installations it is used the plenum type “C”, with the wall hanging of the plenum or ceiling hanging and diffuser’s fixing to the plenum through apposite screws, through slots. Mounting scheme The basic mounting scheme provides the employment of plenum type “A” with hanging of the diffuser to the ceiling through specific brackets. These allow also the diffuserplenum junction (with gasket). The regulation damper can be controlled through a fine tool (for ex.: screwdriver). As alternative, by employment of plenum type “B”, it’s possible to fix diffuser to plenum, working on special suspension screws, through slots. C A* B* E F*** G (mm) (mm) (mm) (mm) (mm) 35/31 51/31 113 158 220 N 1 2 64/60 80/60 113 198 290 3 93/89 109/89 113 198 320 4 122/118 138/118 143 248 400 * LC / LCSB *** external diameter, single inlet for L = 1000 mm, double inlet for L = 1500 mm and L = 2000 mm. D E BF H BF 50 12.5 G A B 12.5 A B Plenum type “C” Plenum type “B” F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 06.06.16 Linear cylinder diffuser pag. A-76 Plenum Plenum type “B” Plenums are equipped with single inlet in case of L = 1000 mm and with double inlet for L = 1500 mm and for L = 2000 mm. Other different executions are possible at request. Plenum type “A” H1 H2 H (mm) (mm) (mm) 1 88 132 220 2 108 152 260 3 108 152 260 4 133 177 310 N * LC / LCSB H1 H2 H (mm) (mm) (mm) 1 100 130 230 2 120 150 270 3 120 150 270 4 145 175 320 N * LC / LCSB Adjustable damper from ambient (in photo PLSB-LC) F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 06.06.16 LC Linear cylinder diffuser LC pag. A-77 Plenum type “C” 550 1000 The composition foresees the use of 2000 mm sectionsin the center and of elements of different lenght at the two ends, according to following rule (nominal lenght L): 450 H1 H2 H 1035/1005* 1500 800 350 350 H1 H2 H 1535/1505* 2000 1000 550 The composition of the plenums follow same rules of the diffusers. On request different compositions are possibile. In the case of composition of elements disposed at 90°, shaped angles are available (ANGLC) that allow a fast and nice connection. 450 H1 H2 L=2500 mm: 1000+1500 L=3000 mm: 1000+2000 L=3500 mm: 2000+1500 L=4000 mm: 2000+2000 L=4500 mm: 1000+2000+1500 L=5000 mm: 1000+2000+2000 L=6000 mm: 2000+2000+2000 L=7000 mm: 1000+2000+2000+2000 L=8000 mm: 2000+2000+2000+2000 H RA 2035/2005* H1 H2 H (mm) (mm) (mm) 1 90 130 220 2 110 180 290 3 110 210 320 4 135 265 400 N R9 * LC / LCSB B Diffusers composition (L > 2000) In case of L > 2000 mm, the execution is made in more parts. The composition of two side by side LC is made through grooved pins and connection plates to be mounted where there are the fixing screws, which can be normally found at the end of the diffuser. A B (mm) (mm) 1 60 51 2 89 80 3 118 109 4 147 138 N F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 06.06.16 Linear cylinder diffuser pag. A-78 Launch configuration By adequate cylinder’s positioning (which have asymmetric profile) into the slot and by using the proper reference marks, it’s possible to obtain the following diffusion geometries: LC 2) Horizontal bilateral ceiling diffusion with alternate throw and without Coanda effect. 1) Horizontal bilateral ceiling diffusion with alternate throw and Coanda effect (alternate tangent). It’s the standard configuration. Cylinders are disposed so that the consecutive elements could generate opposite directions launches. This allows elementary stable jet splitting, with larger induction’s surface, compared to the traditional linear slot diffusers, and then a faster reduction of velocity and temperature difference. The vein adhere to the ceiling and to the walls, in the conventionally occupied zone with a residual velocity that must be the plan’s one. Cylinders disposition F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] It’s the alternative configuration to the 1) when installation height or distance from walls don’t allow its employment (inadequate residual velocity in the conventionally occupied volume). Cylinders are disposed so that the consecutive elements could generate wide apart launches without Coanda effect (angles between jets ≤ 50°). The elementary stable jets splitting, offers a larger induction’s surface and then a faster reduction of velocity and temperature difference. Cylinders disposition 06.06.16 Linear cylinder diffuser LC 3) Vertical ceiling diffusion. It’s the maximum vertical penetration configuration. Cylinders are disposed so that vertical elementary jets could form a single front. pag. A-79 4) Alternate throw wall diffusion. It represents the alternative solution to the traditionals wall grilles. Cylinders are disposed so that the consecutive elements could generate wide apart launches (angles between jets ≤ 50°). The elementary stable jets splitting, ensure a faster reduction of speed and temperature difference. Cylinders disposition Cylinders disposition F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 06.06.16 Linear cylinder diffuser pag. A-80 It’s otherwise possible to opt for “mixed” configurations, by adequated match of the previous cases and proper cylinder disposition. For example it’s possible to orient a part of the jet to the ceiling and another part along the wall, however keeping alternate throw. LC 5) Diffusion with interruption fringes (closed cylinder). Sometimes it can be useful to rotate cylinders until complete slot closure: this option increases even more the diffuser’s versatility. For example in case of vertical launch, when you want to increase the penetration through throw’s velocity increment, or in case of unexpected obstacle, in correspondence of which, it becomes necessary to nullify the jet. Cylinders disposition Cylinders disposition Asymmetrical cylinder F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 06.06.16 Linear cylinder diffuser LC pag. A-81 Performances: L=1000, N=1 (alternate tangent) 50 1 LwA (dBA) 45 40 35 120 100 Key to symbols Distance from wall qv Air-flow per single diffuser Pressure drop LWA Sound power level weighed “A” (rif. 10-12 W) Selection 1 At the requested air-flow qv, according to diagram 1, determine slots number N so that the sound power level LWA can’t exceed the maximum allowed one for plan’s value. 2 At the requested air-flow qv, known N, from point 1 and known the installation height hi, from diagram 2, determine the minimum distance from wall d. 3 At the requested air-flow qv, known N, from point 1, verify from diagram 3 that the pressure drop DP is in accordance with the plan’s value. Correction factors In the case of diverging horizontal ceiling diffusion or alternating wall diffusion, consider a pressure drop increase equal to 70%. In the case of vertical exhaust, consider a pressure drop increase equal to 60%. 200 qv (m3/h) 5 hi=2,5 m 4 d (m) DP 180 2 Installation height d 160 3 hi=3,0 m 2 hi=3,5 m 1 hi=4,0 m 0 100 80 70 120 140 160 180 qv (m3/h) 200 3 60 50 P (Pa) hi 6 140 40 Note The minimum distance from wall d has been determined so that the residual velocity in the occupied volume does not exceed 0,20 m/s. Velocity probes have been disposed at 0,6 m distance from wall, and at a height from floor corresponding to UNI-EN-ISO 7726 norm. In the case project concerns diffusers disposed on parallel rows, it’s recommended to consider 2d as minimum wheelbase. F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 30 25 20 100 120 140 160 qv (m /h) 3 06.06.16 180 200 Linear cylinder diffuser pag. A-82 Performances : L=1000, N=2 (alternate tangent) 50 LC Performances : L=1000, N=3 (alternate tangent) 50 1 1 45 40 LwA (dBA) LwA (dBA) 45 35 35 30 25 100 5 40 120 140 160 180 200 250 300 30 200 qv (m3/h) 6 2 250 qv (m3/h) 300 350 2 5 4 d (m) d (m) hi=3,0 m 2 hi=2,5 m 4 hi=2,5 m 3 400 3 hi=3,0 m 2 hi=3,5 m 1 hi=3,5 m 1 hi=4,0 m hi=4,0 m 0 0 100 60 50 150 200 250 qv (m3/h) 300 200 50 3 250 300 qv (m3/h) 350 400 3 40 40 30 P (Pa) P (Pa) 30 25 20 15 25 20 15 10 100 120 140 160 180 200 250 qv (m3/h) F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 300 10 200 250 qv (m3/h) 300 06.06.16 350 400 Linear cylinder diffuser LC pag. A-83 Performances : L=1000, N=4 (alternate tangent) 45 Air-flow calculation For air-flow calculation must be employed hot-wire anemometers. The probe must be positioned as shown in the picture, in correspondence to cylinders’ middle line, orienting the “window” against the flow. Reference cylinders are: 5° and 6° for L = 1000 mm, 4°, 5°, 11°, 12° for L = 1500 mm, 5°, 6°, 15°, 16° for L = 2000 mm (result is the same counting from right or from left). In each point, the average velocity must be measured in a minimum breaktime of at least 1 minute (average in time). In order to obtain the air-fow, calculate the arithmetic average of the so measured values (ṽk), and multiply it for value Ak, carried in the table, which refers only to diffusion with alternate tangent throw. 1 LwA (dBA) 40 35 30 300 7 350 qv (m3/h) 400 450 2 500 N=1 N=2 N=3 N=4 L = 1000 mm 0,0095 0,0153 0,0234 0,0315 L = 1500 mm 0,0143 0,0230 0,0351 0,0473 L = 2000 mm 0,0190 0,0306 0,0468 0,0630 qv = ṽk x Ak hi=2,5 m 6 Ak (m2) d (m) 5 hi=3,0 m 4 3 hi=3,5 m 2 1 hi=4,0 m 0 300 50 350 400 qv (m3/h) 450 500 3 45 40 P (Pa) 35 30 25 20 300 350 qv (m3/h) 400 450 F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] 500 06.06.16
© Copyright 2026 Paperzz