On-Site Training Program Industrial Wastewater Sampling o Safety o Sampling Procedures o Required Events o Sample Handling o Sample Containers o Documentation o Collection Volume o Labeling and Shipping o Preservation & Hold Time o QC/QA o Sampling Equipment Events can be customized for grab sampling, composite sampling, low-level mercury , bioassay, and other specialized types of sampling Alloway is an approved Ohio EPA contact hour provider. Introduction The most precise and accurate analytical measurements are worthless and even detrimental if performed on a sample that was improperly collected and stored or was contaminated in the process (OEPA, 1978). Introduction Four factors that affect quality of environmental data Sample Collection Sample Preservation Analyses Data Documentation Improper actions in any one area may result in: Poor data Leading to poor judgments 4 Introduction A written sample-handling plan is essential before initiating any program. It will answer the following: What parameters will be analyzed? Frequency of collection and sample type? ○ Grab ○ Composite What types of bottles? What type of chemical preservation? Is thermo preservation required (ice) ? What is the holding time for each parameter? What will be documented on the Chain of Custody? How will samples be delivered to the laboratory? Frequency Definitions Required frequency for sampling is listed in the NPDES permit and shall be collected accordingly Daily, Weekly, Monthly, Semi-Annually, or Annually Depending on plant conditions and continuous monitoring, some of the analyses may be required more frequently. All Samples taken according to proper protocol must be reported to the respective agency Types of Samples: NPDES Frequency Definitions Weekly sample collection requirements OEPA defined weeks ○ Week 1 – days 1 thru 7 ○ Week 2 – days 8 thru 14 ○ Week 3 – days 15 thru 21 ○ Week 4 – days 22 thru 28 7 Types of Samples: NPDES Frequency Definitions cont’d Quarterly (4 times per year) March, June, August, December Semi-annual (2 times per year) June & December Annual (1 time per year) September Safety Proper PPE at the terminal Safety Glasses Safety Shoes Hard Hat * Nomex Positive Attitude Maintain a Safe Work Environment Protect Yourself and Your Colleagues Use Chemicals Safely Sampling Kits Sampling Kits EPA-approved materials, cap liners, and acceptable preservatives Chain of Custody Custody seal(s) Samples on ice sticker Field log form Return shipping labels pH Buffers/Rinse solution Non-Powdered Gloves ICE Sample Preservation Reference 40 CFR 136 Table II – Required Containers, Preservation Techniques, and Holding Times Complete preservation is impossible Minimize the deceleration of the physical, chemical, and biological changes by awareness of nature of changes The effect of one will ultimately have an effect on all! Sample Preservation Nature of Changes (Physical): Physical: Sample Environment has been altered ○ Sampling Equipment Introduce contaminants from outside ○ Sample Containers Residue from previous samples Certain cations are subject to adsorption on, or exchange with, cations in the walls of both glass and plastic containers - Plastic: Al, Cd, Cu, Cr, Fe, Pb, Mn, Zn and Ag - Glass: Na, Bo, Si Sample Preservation Physical Changes (con’t) Temperature ○ Elevated Solubilize precipitated material Increase decomposition of organic materials - Affect the NO3, NO2, NH3, BOD, Phenol, etc. Headspace ○ Zero headspace for volatile organic compounds ○ Microbiological samples should have air space for aeration and mixing Sample Preservation Nature of Changes (Chemical): Chemical ○ Algae creates photosynthetic activity Affects DO, pH, and various other chemical equilibria ○ Metals can precipitate or solubilize, leach from container walls, or be reduced or oxidized Affects the color, odor, or turbidity Sample Preservation Nature of Changes (Biological): Biological ○ Temperature Decreased - Generally retard biological changes (ideal!) Increased - Changes chemical composition - Increased decomposition Sample Preservation Biological Changes (con’t) Changes in the dissolution of gases Consumption of organic material Production of cellular matter Formation of chemical byproducts (CO2, NH3, and H2O) Sample Preservation 3 primary methods of preservation: Refrigeration pH Adjustments Chemical Additions Sample Preservation Refrigeration pH Adjustment Decreases biological and chemical activity ○ i.e. H2SO4 Combined with refrigeration it preserves and pretreats oil & grease Retards bacterial action - COD, TOC, etc. Sample Containers Reference 40 CFR 136 Table II – Required Containers, Preservation Techniques, and Holding Times • “P” for polyethylene • “G” for Glass • Polypropylene or other autoclavable plastic • “LDPE” for low density polyethylene • “PA” for any plastic that is made of a sterilizable material • “FP” for fluoropolymer • PTFE; Teflon® polytetrafluoroet hylene Sample Containers New or used New ○ Most manufacturers certify that their containers are “clean” and may be used without washing or sterilizing Recycled (Used) sampling containers ○ At a minimum, sampling containers and caps must be Washed with non-ionic and nonphosphate detergent Rinsed with hot tap water Rinsed with distilled water Sample Containers Specific to parameters: Oil & Grease ○ Easily adheres to a number of materials Shall be collected in a 1-L, wide-mouth glass jar with a polytetrafluoroethylene (Teflon®) screw lid liner - Wide mouth allows analyst to rinse the inside walls of the jar with solvent during analysis ○ Containers shall not be pre-rinsed with the sample Adherence of oil & grease to sampling container Sample Containers and Volume Container requirements should be specified in the sampling program and may depend on: ○ Volume ○ Interference problems anticipated ○ Type of test being performed ○ Cost ○ Availability ○ Resistance to breakage Sample Volume Fill appropriate container completely, allowing necessary headspace when mixing is required Volatile Organic Compounds and Toxicity samples must be collected at zero headspace Provide sufficient sample appropriate to the analytical method and detection level desired Sampling Equipment The most accurate data on a waste stream would be obtained by collecting and analyzing the entire flow from a discharge point. Sampling Equipment Sample Collected Shall Be: Representative to the total discharge Sufficient volume to represent the source but small enough to be handled in the laboratory Collected in accordance to the defined sampling plan ○ Quality of sampling is ensured by trained sampling personnel Two types of sampling equipment: Manual Collection Automatic Collection ○ Uniformity ensures samples collected were consistently and accurately collected Collected by same method From same point Programmed time intervals ○ Reflect the condition in the source Sampling Equipment Manual Versatile, inexpensive, and simple to use ○ Bottle Samplers Dippers “Jar on a Rope” Swing Samplers® - Allows collection at various angles, including 90° (Nasco) Weighted Bottle Samplers - Glass bottle, weighted sinker, bottle stopper, line to lower and raise the container Sampling Equipment QA/QC Equipment and Maintenance SOPs Composite Sampler Cleaning ○ How to perform it? What kind of soap? - Phosphorus based not good idea for samples being collected for phosphorus analysis - Alconox/ Liquinox ○ How often to perform? ○ Where to document it was performed? Sampling Equipment QA/QC Equipment and Maintenance SOPs Specify the frequency of composite sampler calibrations Specify the calibration procedures ○ Timer calibrations ○ Flow calibrations (volume) Specify how to document calibrations Specify how to charge sampler batteries Specify how to ensure batteries have charge Sampling Equipment QA/QC Parameter General Automatic* Samplers Enter make, model, and serial or identification number for each sampler in a log book Daily Quarterly Portable samplers: check volume setting; stationary samplers on a weekly basis Sampler timer check, checking clock time setting versus actual time interval; Contamination Check Equipment Calibration Calibration Checks ○ *Quality Assurance procedures on sampling equipment according to U.S. EPA, 1982 Blank Checks ○ Contamination checks shall be performed using distilled water through the sampler and sampler equipment. Blank contamination check sampling shall be performed identical to the sampling method used in the field. Sample Documentation – Bottle Labeling Sampling containers should be prepared and labeled prior to sample collection Labels shall be written on using indelible ink Sampling information to be documented on bottle labels shall include: Predetermined location ID Date of sample collection Time of collection Sampler initials Type of sample collected Preservative(s) added Sample Documentation – Bottle Labeling Writing directly on sample bottles may result in ink leaching through the sampling container and could result in contamination Sample labels shall: Adhere to sample container properly Removable ○ If sample container is to be reused User friendly ○ Allows enough space for documentation ○ Works well in inclement weather Sampling Procedure Sampling Procedure ALWAYS CHECK SAMPLING SPECIFICS IN YOUR PERMIT Grab Samples Discreet ○ Collection not to exceed 15 minutes Obtained during the first 30 minutes of a discharge ○ To determine max. concentration of a pollutant Must be conducted for pH, temperature, cyanide, total phenols, residual chlorine, oil & grease, fecal coliform Sampling Procedure Guidelines SOP Specify Location Representative • Proper Sampling Techniques and Guidelines shall be established prior to sample collection • Defined Sampling Site • Sampling must represent the actual process or true flow stream Sampling Procedure VOC Sampling Guidelines Samples collected for the analysis of volatile organic compounds (VOC) should be taken from areas of low turbulence to reduce the amount of entrapped air in the sample. VOCs could be driven off to the atmosphere (as outgas) in turbulent sections of the flow stream The “no head space” requirement for VOC sample containers, meaning no air space in the container, is important to ensure that all VOCs are kept in solution for proper analysis Sampling Guidelines Avoid taking samples at points where solids settling occurs or floating debris is present. These situations occur normally in quiescent areas where the velocity of the flow has decreased. Avoid sampling non-representative deposits or solids accumulated on channel or tank walls. Sampling Guidelines Where samples are to be collected from flowing pipes, keep the sample lines as short as possible and with a minimum number of bends To ensure that the sample is representative, prevent settling by keeping samples thoroughly mixed throughout the collection and measurement procedure Sample Hold Times Composite Set of grab samples composited in the field or laboratory ○ Holding time begins at the time the last grab was collected Sample collected with an automated sampler ○ Holding time begins at the time the last sample was collected Grab Begins at the time of collection Sample Hold Times Analyte pH DO Fecal Coliform Total Coliform BOD (CBOD) Hold Time Immediately Immediately 6 Hours 30 Hours 48 Hours • What is the hold time for: •Cyanide? •Total Suspended Solids? •Volatile Organic Compounds? •Semi-Volatile Organic Compounds? Sample Handling Specified in 40 CFR 136.3 for NPDES Analyte Bottle Type pH Preservation Temp Holding Time BOD or CBOD Plastic or Glass NONE Cool, 6˚C 48 Hours TSS Plastic or Glass NONE Cool, 6˚C 7 days Metals (Except Hg and Cr6) Plastic or Glass HNO3 pH < 2 NONE 6 months NH3 Plastic or Glass H2SO4 pH < 2 Cool, 6˚C 28 Days NO3/NO2 Plastic or Glass H2SO4 pH < 2 Cool, 6˚C 28 Days Sample Handling Chain of Custody A sample is under custody if: ○ It is in your possession, or ○ It is in your view, after being in your possession, or ○ It was in your possession and then you locked it up to prevent tampering, or ○ It is in a designated secure area The field sampler is personally responsible for the care and custody of the samples collected until they are transferred During transfer of possession of samples the involved persons relinquishing and receiving must: ○ Sign ○ Date ○ Note time of transfer on chain of custody Sample Handling Sample Acceptance Policy Chain of Custody Review for: ○ Client name ○ Contact name ○ Sample identification ○ Project identification ○ Sample location ○ Date & Time of Collection ○ Identification of collector ○ Preservations ○ Sample type (grab or composite) ○ Proper documentation of time line and custody Chain of Custody Example Reporting Quality Data Verifying Quality of Data Representative sample collection Sample Handling Document Control Laboratory Analysis ○ MDL Studies ○ Calibrations ○ QC Activities for Accuracy and Precision ICV, CCV, Blank, MS/ MSD Reporting to required Agency Conclusion Planning Observe the outfall/discharge Obtain samples first week of month Know the parameters Correct sampling procedures Calibration Obtain sample Documentation Field Log Chain-of-custody Shipping of samples Shipping label Ice 800-436-1243 [email protected] www.alloway.com
© Copyright 2026 Paperzz