MSI-s, MSI-sx Advantages - MSI-s " Safety interface, Type 4, according to IEC-, EN 61496-1 or EN 954-1, Category 4 " 1 AOPD, Type 4, or 2 AOPDs, Type 2, can be connected " Start/restart interlock and relay monitoring can be selected " 2 normal open contacts, max. 6 A, or 2 failsafe pnp outputs " RS 232 interface for PC-supported diagnostics and easy start-up " Status outputs "switch output status” and "start/restart interlock status” " Pluggable connection terminals and pluggable output subassemblies " Multiple MSIs can be cascaded " Reinforced isolation up to 4 kV in accordance with IEC 439-1 " Housing width: 35 mm Additional Advantages - MSI-sx Safety Interface Subject to change without notice The modular safety interfaces of the MSI family serve as a link between one or more optoelectronic protective devices (AOPDs), Type 2, Type 3 or Type 4, and the machine controls. The individual versions offer various safetyrelated additional functions, such as start/restart interlock, relay monitoring, test monitoring of Type 2 sensors, single break/double break control, or muting. All components are available with a choice of relay outputs or failsafe pnp semiconductor outputs. In addition, the -x versions also allow the connection of safety switches or Emergency Stop pushbuttons in accordance with Category 4. " 2 AOPDs, Type 4, or up to 4 AOPDs, Type 2 or, for example, 1 AOPD, Type 4, and 1 safety switch can be connected " Counting of relay operations with pre-failure message for preventive maintenance " Warning output "relay life expectancy reached; recommend relay replacement” Areas of Application " Interface component between optoelectronic protective devices, Type 4, Type 3 or Type 2, and machine controls with the functions start/restart interlock, relay monitoring " Light barrier interface, Type 4, and Emergency Stop disconnection, Stop category 0 (IEC 60204-1) EN 954 Kat. 4 MSI –2– Leuze lumiflex Function Feature Maximum safety category (EN 954-1) Stop category (IEC-, EN 60204-1) Max. number of AOPDs, Type 2, or Emergency Stop command devices (Cat. 2) Max. number of AOPDs, Type 4, or Emergency Stop command devices (Cat. 4) Cross circuit monitoring Start/restart interlock Static relay monitoring Dynamic relay monitoring RS 232 diagnostics interface Status output "system error" Warning "relay replacement necessary" Secondary switching device (SSD) output opens additional to the OSSDs in case of a MSI failure MSI-s 4 0 2 MSI-sx 4 0 4 1 2 x x x x x x x x x x x x x 10 16 17 S2 S3 S4 13 11 14 0V a b c d e f Reset EDM PNP PNP OSSD1 OSSD2 +24V 7 5 6 2 2 + Warn. State State OSSD1 5 Tx-Output 7 f 6 10 12 d 1 PNP Rx-Output RS 232 18 e 9 1 MSIfault 9 State 3 6 7 8 5 f SSD State T-Output OSSD2 AOPDs MSI-sx/Rx + c 23 Leuze lumiflex S2 AOPDs PNP S1 S1 OSSD1 T2 Test T2 Diagn. N.O. T1 T1 14 13 SSD 22 Reset 24 Diagn. 6 b 15 +24V a 4 23 RS 232 RS 232 0V 7 22 MSI-s/T State 9 24 0V Diagn. 15 Leuze lumiflex R-Output OSSD2 MSI-s/R N.C. Leuze lumiflex 4 Test OSSD3 S2 AOPDs N.O. S1 2 N.O. T2 Test 11 N.O. T1 14 13 OSSD2 23 OSSD1 22 EDM 24 Reset 15 EDM 4 +24V A detailed technical description is provided with every delivery. d = Test outputs for Type 2 test and cross circuit monitoring = Inputs for connecting AOPDs or Emergency Stop command devices = Input for relay monitoring = Safety outputs, either relays or failsafe semiconductors = RS 232 diagnostics interface = Warning and status outputs MSI –3– 3 8 Electrical Connection +24 V 2,5 AT 0V d k3 L+ Ph 6AT max k2 a 24 22 16 17 13 14 T1 T2 S1 S2 S3 S4 Reset EDM AOPDs Leuze lumiflex Rx-Output MSI-sx/Rx Warn. State State 9 OSSD1 RS 232 0V b 5 18 7 g f MSIfault 6 12 i 10 SSD Diagn. 2 OSSD2 Test 11 OSSD3 23 N.O. 15 N.C. 4 +24V k1 N.O. c LN 3 1 e K2* K1* k1 k2 k2 k1 h k3 6AT max K3* LN LN ** L+ Ph Connection example: MSI-sx/Rx with two Type 4 safety light curtains a = AOPD, Type 4 (e.g. Compact) b = AOPD, Type 4 (e.g. Compact) c = Command device for start/restart interlock d = Feedback circuit for relay monitoring e = Secondary switch-off circuit (opens in case of MSI error) f = Switching off path with 2-channel control g = Switching off path with 1-channel control h = Possible collective output for error/warning (active-low) i = Safety outputs OSSD1 and OSSD2 (OSSD3 optional) * = Suitable spark suppression required ** = Always use both contacts in the switching off path. Use only downstream relays with positively opening contacts. MSI –4– ** Leuze lumiflex Dimensional Drawings Technical Data Relevant standards, Safety category 1 4 2 5 a b e State Locked Fault S1 & S2 MSI ROutput 7 10 8 9 11 12 Fault 2 5 3 6 13 14 15 16 17 18 lumiflex Leuze lumiflex Diagn. b c d 1 4 13 14 15 16 17 18 3 6 Leuze g h Warn. Diagn. State S3 & S4 c Locked d Fault MSI Rx Output MSI- s 7 10 19 20 21 22 23 24 IEC-, EN 61496-1, Type 4 EN 954-1 (12/96), Category 4 IEC-, DIN EN 60204-1 (11/98), Stop 0 DIN V VDE 0801 and A1, Specification class 6 Connectable safety MSI-s: 1 AOPD, Type 4 *), sensors Type 3 or 2x Type 2 MSI-sx: 2 AOPDs, Type 4 *) or up to 4 AOPDs, Type 2 *) Sensors with relay or semiconductor outputs Connectable safety Safety switches in accorswitches and comdance with EN 1088 mand devices Emergency Stop pushbuttons in accordance with EN 418 Response time MSI-s/R or /Rx: 1) (without AOPD) MSI-s/T or /Tx: 2) Functions - Relay monitoring, start/restart interlock Relay outputs MSI-s/R: 2 normal open OSSDs contacts, 6 A max. MSI-sx/Rx: 2 normal open contacts, 1 normal closed contact, 6 A max. Failsafe semiMSI-s/T: 2 PNP 24 V DC, conductor outputs 0,5 A max. (inductive load) OSSDs MSI-sx/Tx: 2 PNP 24 V DC, 0,5 A max. (inductive load) Relay output SSD MSI-sx/Rx, MSI-sx/Tx: (opens in case of MSI 1 normal open contact, failure) 6 A max. Status outputs "Switch output status” *) "Start/restart interlock status” *) "Electrical relay life expectancy reached” *) **) *) pnp 24 V DC, 50 mA **) only for MSI-sx/Rx Functions - Relay monitoring, start/restart interlock - Emergency Stop disconnection, Stop category 0 *) - Counting of relay operations and prefailure message **) *) only for MSI-sx/.. **) only for MSI-sx/Rx Diagnostics interface RS 232 Supply voltage 24 V DC +/- 15% (115/230 V AC power supply as accessory) Connection type Pluggable screw-type terminals up to 2.5 mm2 Protection class II Enclosure rating IP 20; must be installed in an electronics cabinet with IP 54 Housing width 35 mm e f S1 & S2 g Fault h MSI- sx 8 9 11 12 19 20 21 22 23 24 35 35 Side view 99.0 111 113.6 a b c d e f g h = Theoretical relay life expectancy reached (LED red) = Safety output status (LED red/green) = Start/restart interlock locked (LED yellow) = Error in safety output module (LED red) = RS 232 diagnostics output = AOPDs at S3 and S4 protected field free (LED green) = AOPDs at S1 and S2 protected field free (LED green) = MSI error (LED red) Order Details Type MSI-s/R MSI-s/T MSI-sx/Rx MSI-sx/Tx MSI-AC230 (power supply 24V DC, 0.8 A) MSI-AC115 (power supply 24V DC, 0.8 A) MSI diagnostics software + PC cable /R output subassembly (replacement part) /Rx output subassembly (replacement part) Order No. 549900 549920 549901 540021 549908 549940 549930 509210 509211 MSI –5– 1) 18 ms for: AOPD, Type 4, with semiconductor output 54 ms for: AOPD, Type 4, with relay output AOPD, Type 2 Safety switches 2) 8 ms for: AOPD Type 4 with semiconductor output 44 ms for: Type 4, with relay output AOPD, Type 2 Safety switches
© Copyright 2026 Paperzz