APPLICANT: AENOR (Asociación Española de Normalización y Certificación). REACTION TO FIRE CLASSIFICATION ACCORDING TO STANDARD UNE-EN 13501-1:2007+A1:2010 • Product: Manufactured insulating product of flexible elastomeric foam Manufacturer: Kaimann GmbH. Reference: “KAIFLEX ST” Nr 2628T13-3 Translation of original Spanish report English Version Page 1 de 6 Classification Report Nr 2628T13-3 Translation of original Spanish report English Version Page 2 of 6 REACTION TO FIRE CLASSIFICATION ACCORDING TO UNE-EN 13501-1:2007+A1:2010 STANDARD Applicant: AENOR (Asociación Española de Normalización y Certificación) C/Genova, nº 6 28004 – MADRID Issuer Laboratory: AFITI-LICOF Notified body nº: Product: 1168 Manufactured insulating product of flexible elastomeric foam Manufacturer: Kaimann GmbH. Hansastrasse, 2-5 D-33161 – HÖVELHOF (Germany) Reference: Classification report Nr: “KAIFLEX ST” 2628T11-3 (English Version) Date of issue: 14th-May-13 Content of the report 1.2.3.4.5.- Aim of the report ..................................................................................... Details of classified product ................................................................................ Reports and test results in support of this classification ..................................... Classification and field of application................................................................. Limitations ..................................................................................... Page 3 Page 3 Page 3 Page 5 Page 5 This report is a translation of the Spanish Classification Report dated 22nd-Apr-13. In case of doubt, the Spanish version of the Classification Report prevails. This classification report nr 2628T13-3 supersedes to the Classification report nr 2628T13-2. The information held in this Classification Report is a confidential nature, meaning the Laboratory shall not provide information in relation to this report to third parties, except with the authorisation of the Applicant. It is not allowed to reproduce partially this Classification Report without the Laboratory’s written approval.. English Version Classification report Nr 2628T13-3 1.- AIM OF THE REPORT This Classification report defines the Reaction to Fire classification assigned to the manufactured insulating product of flexible elastomeric foam referenced by the applicant as “KAIFLEX ST”” on the basis of the procedures established in the standard UNE-EN 13501-1:2007+A1:2010 “Fire classification of construction products and building elements-Part 1: Classification using data from reaction to fire tests”. 2.- DETAILS OF CLASSIFIED PRODUCT 2.1.- GENERAL The product defined by the applicant as “KAIFLEX ST” defined as Manufactured insulating product of flexible elastomeric foam according to the corresponding technical specification. 2.2.- DESCRIPTION The product “KAIFLEX ST” is described as insulation jacket of elastomeric foam with an internal diameter of 22 mm, a thickness of 50 mm, a density of 50 kg/m3, of black colour and smooth aspect. 3.- REPORTS AND TEST RESULTS IN SUPPORT OF THIS CLASSIFICATION 3.1.- TESTS. Tests reports Issuer Laboratory AFITI-LICOF Pol. Ind. Sta. Mª de Benquerencia C/ Río Estenilla, s/n 45007-TOLEDO Notified Body Nr: 1168 Applicant Report Test standard AENOR (Asociación Nº: 2628T13 UNE-EN Española de 13823:2012 h Date of issue: 19 -Apr-13 Normalización y th Test date: 16 -Apr-13 Certificación) C/ Génova, nº 6 28004 – MADRID Test date: 17th-Apr-13 End use application Heating and cooling systems. UNE-EN ISO 111925-2:2011 It is not allowed to reproduce partially this Classification Report without the Laboratory’s written approval.. Page 3 of 6 English Version Classification report Nr 2628T13-3 Test results Test report nº Test Method 2628T13 Parameters Nr of tests FIGRA0,2MJ (W/s) UNE-EN 13823:2012, S.B.I FIGRA0,4MJ (W/s) LSF < edge THR600s (MJ) SMOGRA (m2/s2) TSP600 s (m2) 3 Results Continuous Compliance with parameter mean parameters (m) 98,27 Non applicable Non applicable 7,2 879,69 1591,3 Non applicable Drops / Particles flamed Non applicable Non applicable Yes No Non applicable Non applicable Non applicable Yes No Results Test method Parameters Nr. tests Continuous parameter mean (m) Compliance with parameters UNE-EN ISO 11925-2:2011 Esposure =30 s Fs ≤ 150 mm Non applicable Yes No Non applicable Yes No 6+6 Drops / Particles flamed Ignition of filter paper Remark: The information included in the column “Nr. Tests” indicates the number of specimen tested according to the instructions of test standard. It is not allowed to reproduce partially this Classification Report without the Laboratory’s written approval.. Page 4 of 6 English Version Classification report Nr 2628T13-3 4.- CLASSIFICATION AND FIELD OF APPLICATION 4.1.- CLASSIFICATION STANDARD Reaction to Fire classification according to UNE-EN 13501-1:2007+A1:2010 standard. 4.2.- CLASSIFICATION The product “KAIFLEX ST” reaches the following classification: Reaction to fire classification Fire Behaviour BL Smoke Production s BL– 3 Flaming droplets , d 0 s3 , d0 4.3.- FIELD OF APPLICATION This classification is only valid for the mounting conditions and the characteristics product detailed in the test report nr 2628T13. 5.- LIMITATIONS This document does not represent type approval or certification of the product. Toledo, 14th of May of 2013 Author: Signed: Supervised: David Sáez García Technician of Fire Reaction Laboratory Signed: Antonio Galán Penalva Technical Director of Fire Reaction Laboratory It is not allowed to reproduce partially this Classification Report without the Laboratory’s written approval.. Page 5 of 6 English Version Classification report Nr 2628T13-3 Page 6 of 6
© Copyright 2026 Paperzz