EVW / PVW - PH Systems bvba

186
143
120
230
Voice Synthesizer
RECORD&PLAY
166
105
EVW type
EVW / PVW
EVW / PVW
122
100
PVW type
38
58
3- ø9
From wire exit 400
25
EVW / PVW
Dimensions
25 25
(mm)
125
105dB at 1m
EVW 60 sec
PVW 64 sec
Wiring Diagram
EVW type
Fuse
EVW 4 channels
PVW 15 channels
White
Power supply
IP53
PVW type
Black
1
Skyblue
2
Yellow
3
Pink
Voice: CH1~CH4·STOP
Circuit: Vs=20V
( Open
Closed Circuit: Is=5mA )
Is
COM Brown
4 Light green
STOP
500mA
+
Horn-type Voice Synthesizer featuring 4 recordable
messages up to 60 sec. with a microphone .
*1
–
COM
DC
24V
BUSY OUT Orange
GND
Blue
Shielded wire
AUX OUT Green
*2
External amplifier
*1 PVW-04/-15 type: 4 or 15 selectable pre-installed messages up to 64 sec.
*2 EVW only.
· Built-in Alarm: Adjustable audible sound volume up to 105dB at 1m with volume control.
· ADPCM 64kbit/s: Clear sound quality from LSI digital voice synthesizer for PVW type (32kbit/s for EVW
type).
· Recordable Messages: 4 recordable*1 and editable messages up to 60 sec. with microphone*2 (EVW).
· Installation: Indoors—upright, inverted, sideways; Outdoors—upright only.
· Easy Installation: With anticorrosive stainless steel mounting bracket.
*1 Message data can be transferred easily with optional cable EVH-K (Sold separately).
*2 Refer to channel priority when more than one replay input is received.
Red
Brown
Source Voltage
Rated Voltage
12V
24V
100V
220V
Fuse
1A
0.5A
0.3A
0.15A
More than 100ms.input is required to activate the message.
Channel priority
STOP (Red) >CH4 (Light green) >CH3 (Pink) >CH2 (Yellow) >CH1 (Skyblue)
Note: The greater number has priority when any of the channels are activated simultaneously.
EVW / PVW type
Available by Special Order
· CE Compliance: PVW-**JF type.
Outer Contact
Operating
Power
Volume
Auxiliary Input Channel AUX Output BUSY Output Max Message Protection
Capacity
Temperature Range
Consumption
Time
8~28V AC
10W/9W
EVW-04JF 12/24V AC/DC
9~35VDC
Voltage free
-10°C~+55°C
Max.
-10dBv
Max. load
More than
contact
Humidity
105dB
90V~135V AC
18W
100V AC
EVW-04KF
4
60 sec.
IP53
600?
24V DC 500mA
10mA
4/1bit
85% or less.
at 1m
180V~270V AC
18W
EVW-04QF 220V AC
Model
Concept of Horn Configuration.
Conventional type
New wide Horn Type
Rated
Voltage
Voltage
Range
Mass
1.2kg
1.4kg
1.4kg
Max Message
Operating
Power
Rated
Volume Outer Contact
Voltage Range
Auxiliary Input Channel AUX Output BUSY Output
Protection Mass
Time
Capacity
Temperature Range
Consumption
Voltage
8~28V AC
12W
1.3kg
12/24V
AC/DC
PVW-04JF
9~35V DC
Voltage free
35V~60V DC
10W
1.3kg
48V DC
PVW-04DF
contact
4
90V~132V AC
18W
1.4kg
100V AC
PVW-04KF
4/1bit
Max.
-10°C~+55°C
-10dBv
180V~260V AC
18W
1.4kg
220V AC
PVW-04QF
Max. load
More than
64
sec.
105dB
Humidity
IP53
8~28V AC
600?
24V DC 500mA
10mA
1.3kg
12W
PVW-15JF 12/24V AC/DC
9~35V DC
at 1m
85% or less.
Voltage free
1.3kg
10W
48V DC
35V~60V DC
PVW-15DF
contact
15
18W
100V AC
90V~132V AC
1.4kg
PVW-15KF
15/binary
18W
220V AC
180V~260V AC
1.4kg
PVW-15QF
Model
Driving unit
New design increases volume output by changing the location of
the driving unit from the back to the front.
115
PH SYSTEMS - www.phsystems.be - [email protected]
116