LED totaL powEr tEst systEm moDEL 58173

LED total power Test System
MODEL 58173
The Chroma 58173, in automatic operation, comes
with unique design and a whole new method for
LED total power measurement. In bare wafer/chip
LED test production, partial flux correction of
total flux is the common measurement method in
LED epitaxy industry. (See Figure 1 on flip page)
However, conventional method causes some
disadvantages, i.e., lower accuracy, low S/N ratio,
and slow test time etc., and which are difficult to
be applied on LED bar wafer/chip total power/flux
test production.
Chroma has developed a high speed and high
accuracy measurement method of LED total
power/flux. (See Figure 2 on flip page) Appling
this innovative test method enhances to gather
more LED partial flux than using the conventional
method. (See Figure 1 on flip page) It improves
the accuracy dramatically and significantly.
Benefited Chroma's unique optical and mechanical
design, LED total radiant flux will be collected by
a wide photo detector. Other optical features like
dominant wavelength, peak wavelength, CCT, etc.
will be detected by Chroma's spectrometer. In
addition, the 58173 offers a 6-inch wafer chuck
and a packaged LED holder which users can
collect variety of samples in one station. With
a wide range of power source and meter, users
can gather all of LED electrical data like forward
voltage, leakage current, and reverse break voltage
in one test step.
Key Features
■ Chroma® Huge Photo Detector
■ New method and unique design for
LED total power measurement
■ High speed automatic LED wafer/chip prober
machine
■ 6" wafer chuck on board
■ Wide range of electrical test
Hardwares
■ Automatic LED wafer/chips prober
■ Leakage test module
■ Source/measure module
■ Optical test module
■ Optional ESD test module
Chroma® Huge Photo Detector
Figure 1
Conventional Method of
LED Wafer/chip Total Flux Measurement
SPECIFICATIONS-1
Model
Current-Voltage Testing
Stimulus Current Ranges
Current Accuracy
Voltage Range
Compliance Voltage Range
Compliance Voltage accuracy
Voltage Measurement
Voltage Accuracy
Voltage-Current Testing (Reverse Voltage)
Stimulus Voltage Ranges
Voltage Measurement Ranges
58173
10uA/2mA/20mA/480mA (800mA optional)
See specification-2, 0.6%±500uA (800mA optional)
1~7V / 7~20V (optinal)
See specification-2 / 3.5%±40mV
7V / 7~20V
See specification-2 / 0.75%±40mV (7~20V optional)
Current Measurement Ranges
Compliance Current Ranges
Wavelength / Colour measurements
Detector Type
Spectrameter
Wavelength Range Visible
Total Measurement LED Angle
Wavelength Resolution (FWHM)
*2
Radiant Flux repeatability (mW)
Dominant Wavelength Repeatability
CIEx,y Accuracy
Mechanical Specifications
Manual Prober
Chuck Size
Dimension
Weight
Power Input
Air input
Air Flow Rate
Software
Operation System supported
Photo Meter
Auxiliary LED
Baffle
0~10V, 0~200V (Accuracy±0.3% ±0.1% FS)
0~10V, 0~200V (Accuracy±0.3% ±0.1% FS)
100μA/ 5mA±0.3%, ±0.2%±0.1%FS
*1
1μA , ±2%±0.1%FS
0~100μA, 0~5mA (Accuracy±5%, ±0.1% FS)
50mm
D
Chroma® Huge Photo Detector
Chroma® 52962
380~780nm
≧128°
±0.24nm
±5%
±1 nm
±0.004
Chip
LED Stage
Figure 2
Chroma's Innovative Method of
LED Total Flux Measurement
wafer chuck
6 inch
970 (L) x 970 (W) x 2250 (H)mm
580kg
220V
Φ6 mm
7 L/min
Chroma Huge Photo Detector
θ ≧128°
Chip
LED Stage
Microsoft Windows 2000 or XP®
* Note 1 : test condition > 30nA and under resistor load
* Note 2 : depends on DUT quality and without thermal effect
SPECIFICATIONS-2
Voltage Accuracy
Range
Source Accuracy ±(% reading. + volts)
Programming Voltage
Measure Accuracy ±(% reading. + volts)
Current Accuracy
Range
Programming Current
Source Accuracy ±(% reading. + amp)
Meausre Accuracy ±(% reading. + amp)
0~1V
3%+2.5mV
0~1V
0.5%+1.5mV
10uA
0~0.5uA
0.5~10uA
0.5%+30nA
0.1%+30nA
0.5%+300nA
0.2%+20nA
1~7V
0.6%+8mV
1~7V
0.5%+2mV
2mA
0~0.3mA
0.45%+2uA
0.6%+1uA
0.3mA~2mA
0.45%+2uA
0.35%+600nA
20mA
0~3mA
3mA~20mA
0.66%+20uA 0.66%+20uA
0.7%+60uA
0.5%+60uA
480mA
0~50mA
50mA~500mA
0.3%+900uA 0.3%+900uA
0.6%+600uA 0.3%+600uA
All specifications are subject to change without notice. Please visit our website for the most up to date specifications.
Current
ORDERING INFORMATION
Current
480mA
58173 : LED Total Power Test System
800mA
250mA
Voltage
Voltage
6V 7V
20V
Optional Source Meter Unit
Developed and Manufactured by :
CHROMA ATE INC.
致茂電子股份有限公司
HEADQUARTERS
66, Hwaya 1st Rd.,
Hwaya Technology Park,
Kueishan, Taoyuan 33383,
Taiwan
Tel: +886-3-327-9999
Fax: +886-3-327-8898
http://www.chromaate.com
E-mail : [email protected]
CHINA
CHROMA ELECTRONICS
(SHENZHEN) CO., LTD.
8F, No.4, Nanyou Tian An
Industrial Estate, Shenzhen,
China PC: 518054
Tel: +86-755-2664-4598
Fax: +86-755-2641-9620
JAPAN
CHROMA JAPAN CORP.
11F NARA Building ‖ 2-2-8
Shinyokohama, Kouhokuku,
Yokohama city 222-0033
Kanagawa, Japan
Tel: +81-45-470-2285
Fax: +81-45-470-2287
U.S.A.
CHROMA ATE INC. (U.S.A.)
7 Chrysler Irvine, CA 92618
Tel: +1-949-421-0355
Fax: +1-949-421-0353
Toll Free: +1-800-478-2026
EUROPE
CHROMA ATE EUROPE B.V.
Morsestraat 32, 6716 AH Ede,
The Netherlands
Tel: +31-318-648282
Fax: +31-318-648288
58173-E-201001-500