LED total power Test System MODEL 58173 The Chroma 58173, in automatic operation, comes with unique design and a whole new method for LED total power measurement. In bare wafer/chip LED test production, partial flux correction of total flux is the common measurement method in LED epitaxy industry. (See Figure 1 on flip page) However, conventional method causes some disadvantages, i.e., lower accuracy, low S/N ratio, and slow test time etc., and which are difficult to be applied on LED bar wafer/chip total power/flux test production. Chroma has developed a high speed and high accuracy measurement method of LED total power/flux. (See Figure 2 on flip page) Appling this innovative test method enhances to gather more LED partial flux than using the conventional method. (See Figure 1 on flip page) It improves the accuracy dramatically and significantly. Benefited Chroma's unique optical and mechanical design, LED total radiant flux will be collected by a wide photo detector. Other optical features like dominant wavelength, peak wavelength, CCT, etc. will be detected by Chroma's spectrometer. In addition, the 58173 offers a 6-inch wafer chuck and a packaged LED holder which users can collect variety of samples in one station. With a wide range of power source and meter, users can gather all of LED electrical data like forward voltage, leakage current, and reverse break voltage in one test step. Key Features ■ Chroma® Huge Photo Detector ■ New method and unique design for LED total power measurement ■ High speed automatic LED wafer/chip prober machine ■ 6" wafer chuck on board ■ Wide range of electrical test Hardwares ■ Automatic LED wafer/chips prober ■ Leakage test module ■ Source/measure module ■ Optical test module ■ Optional ESD test module Chroma® Huge Photo Detector Figure 1 Conventional Method of LED Wafer/chip Total Flux Measurement SPECIFICATIONS-1 Model Current-Voltage Testing Stimulus Current Ranges Current Accuracy Voltage Range Compliance Voltage Range Compliance Voltage accuracy Voltage Measurement Voltage Accuracy Voltage-Current Testing (Reverse Voltage) Stimulus Voltage Ranges Voltage Measurement Ranges 58173 10uA/2mA/20mA/480mA (800mA optional) See specification-2, 0.6%±500uA (800mA optional) 1~7V / 7~20V (optinal) See specification-2 / 3.5%±40mV 7V / 7~20V See specification-2 / 0.75%±40mV (7~20V optional) Current Measurement Ranges Compliance Current Ranges Wavelength / Colour measurements Detector Type Spectrameter Wavelength Range Visible Total Measurement LED Angle Wavelength Resolution (FWHM) *2 Radiant Flux repeatability (mW) Dominant Wavelength Repeatability CIEx,y Accuracy Mechanical Specifications Manual Prober Chuck Size Dimension Weight Power Input Air input Air Flow Rate Software Operation System supported Photo Meter Auxiliary LED Baffle 0~10V, 0~200V (Accuracy±0.3% ±0.1% FS) 0~10V, 0~200V (Accuracy±0.3% ±0.1% FS) 100μA/ 5mA±0.3%, ±0.2%±0.1%FS *1 1μA , ±2%±0.1%FS 0~100μA, 0~5mA (Accuracy±5%, ±0.1% FS) 50mm D Chroma® Huge Photo Detector Chroma® 52962 380~780nm ≧128° ±0.24nm ±5% ±1 nm ±0.004 Chip LED Stage Figure 2 Chroma's Innovative Method of LED Total Flux Measurement wafer chuck 6 inch 970 (L) x 970 (W) x 2250 (H)mm 580kg 220V Φ6 mm 7 L/min Chroma Huge Photo Detector θ ≧128° Chip LED Stage Microsoft Windows 2000 or XP® * Note 1 : test condition > 30nA and under resistor load * Note 2 : depends on DUT quality and without thermal effect SPECIFICATIONS-2 Voltage Accuracy Range Source Accuracy ±(% reading. + volts) Programming Voltage Measure Accuracy ±(% reading. + volts) Current Accuracy Range Programming Current Source Accuracy ±(% reading. + amp) Meausre Accuracy ±(% reading. + amp) 0~1V 3%+2.5mV 0~1V 0.5%+1.5mV 10uA 0~0.5uA 0.5~10uA 0.5%+30nA 0.1%+30nA 0.5%+300nA 0.2%+20nA 1~7V 0.6%+8mV 1~7V 0.5%+2mV 2mA 0~0.3mA 0.45%+2uA 0.6%+1uA 0.3mA~2mA 0.45%+2uA 0.35%+600nA 20mA 0~3mA 3mA~20mA 0.66%+20uA 0.66%+20uA 0.7%+60uA 0.5%+60uA 480mA 0~50mA 50mA~500mA 0.3%+900uA 0.3%+900uA 0.6%+600uA 0.3%+600uA All specifications are subject to change without notice. Please visit our website for the most up to date specifications. Current ORDERING INFORMATION Current 480mA 58173 : LED Total Power Test System 800mA 250mA Voltage Voltage 6V 7V 20V Optional Source Meter Unit Developed and Manufactured by : CHROMA ATE INC. 致茂電子股份有限公司 HEADQUARTERS 66, Hwaya 1st Rd., Hwaya Technology Park, Kueishan, Taoyuan 33383, Taiwan Tel: +886-3-327-9999 Fax: +886-3-327-8898 http://www.chromaate.com E-mail : [email protected] CHINA CHROMA ELECTRONICS (SHENZHEN) CO., LTD. 8F, No.4, Nanyou Tian An Industrial Estate, Shenzhen, China PC: 518054 Tel: +86-755-2664-4598 Fax: +86-755-2641-9620 JAPAN CHROMA JAPAN CORP. 11F NARA Building ‖ 2-2-8 Shinyokohama, Kouhokuku, Yokohama city 222-0033 Kanagawa, Japan Tel: +81-45-470-2285 Fax: +81-45-470-2287 U.S.A. CHROMA ATE INC. (U.S.A.) 7 Chrysler Irvine, CA 92618 Tel: +1-949-421-0355 Fax: +1-949-421-0353 Toll Free: +1-800-478-2026 EUROPE CHROMA ATE EUROPE B.V. Morsestraat 32, 6716 AH Ede, The Netherlands Tel: +31-318-648282 Fax: +31-318-648288 58173-E-201001-500
© Copyright 2026 Paperzz