Kvadrat Soft Cells Installation guide version 2015.09.17 Introduction Kvadrat Soft Cells are patented panels that control sound absorption. Their design is based on an innovative, aluminium frame, with a concealed tensioning mechanism that keeps the surface of the fabric perfectly stretched. They create an aesthetic environment with excellent acoustic properties. Soft Cells have been developed to offer modular and flexible solutions for diverse interior requirements. Primarily used as building components, they are also suitable for post-fitting. The frames are customiseable and can be manufactured in large sizes and in most angles. They are easy to install, and can be easily be taken down, reassembled and reupholstered to meet changing requirements. When installed by Kvadrat’s White Glove Installers, they come with a 10-year guarantee. Mineral-based absorber Fibreglass back textile SECTION Soft Cells Lowtone Front textile Mineral-based absorber SECTION - Soft Cells Broadline Front textile Back textile SECTION - Soft Cells Front textile SECTION - Soft Cells Aesthetic Front textile 1 Handling 1. Use gloves when working with Soft Cells 2. Handle Soft Cells using cardboard covers 3. Arrange Soft Cells according to size 4. Place front against front and back against back 5. Store Soft Cells upright 6. Never place Soft Cells on the corners 7. Make sure to work on a clean and flat surface. 8. Read the installation guide prior to installation 9. Refer to the labels that are on all the Soft Cells 10. Do not unwrap Soft Cells before the site is clean 2 General guidelines All fittings are installed into a groove on the back of the frame profile with a rhombus-shaped steel nut. The steel nut comes with a shape that makes it slide into position once placed in the groove and tightened. When untightened, easily adjust the position of the fitting and steel nut along the frame profile Please observe the distances for different corner installations here below mm m m mm mm mm mm mm mm mm 3 Magnet The magnet fitting is the standard way of installing Soft Cells onto walls and ceilings. For ceiling installations, safety wires should always be used. They should also be applied for any situation where Soft Cells are installed 3m or more above floor level, measured from the highest point of the Soft Cells to the floor. Amount of magnets is defined according the lengths and width of the panel See drawing on next page (magnet detail). The correct number of magnets are as standard factory mounted to the frame in the groove on the back of the panel and can easily be moved into correct position by gently releasing the magnet from the rhombus nut and sliding it along the groove. Magnets should be evenly distributed along the panel edge. Mount the steel plate on the wall or ceiling. Align to the dimensions of the magnets mounted on the Soft Cells, to ensure the largest possible area of contact. Adjust by gently pushing the side of the Soft Cells. 2108 Magnet fitting v3 1085 Steel plate 1257 Magnet m5, 24 1258 Rhombus steel nut m5 4 450 mm max 400 52 max 928 mm (first bracing when frame over 1000mm) max 900 mm 38,6 52 450 mm max 400 max 928 mm (first bracing when frame over 1000mm) 55 Magnet detail SIDE VIEW Bracing (1202) Magnet fitting (2101) max 400 900 mm max 900 mm BACK VIEW 5 max 400 900 mm 39 Hinge fitting The hinge fitting is used together with a push latch in situations, when access behind the Soft Cells is required. Amount of hinges equals the amount of push latches on the frame. All hinges are fastened on one side of the Soft Cells frame. On the opposite side to the hinges are the push latches. The perpendicular sides are left without any fittings. Safety wires should only be placed on the push latch side of the Soft Cells panel. 2104 Hinge fitting Push latch Push latch latch Push 1123 Keeper 1123 Socket button head screw m5x12 1123 1113 Keeper Keeper 1113 Rhombus steel nut m5 1113 1124 Plate for hinge 1124 1121 Soft Cells hinge 1121 1124 1121 1123 Socket button head screw m5x12 1123 1123 1113 Rhombus steel nut m5 1113 1113 6 Push latch and hinge detail 55 Safety wire A Push latch max 900 mm Hinge 5 mm slotted holes for mounting on wall and ceiling 55 max 900 mm 6 mm hole for mounting to Unistrut DETAIL A ACK VIEW 38,50 mm for unistrut installation 6 mm hole for mounting to Unistrut max 400 mm 38,50 mm for unistrut installation 35,50 mm for unistrut installation 28 mm for general installation 35,50 mm for unistrut installation DETAIL B 35,50 for un 6 mm hole for mounting to Unistrut DETAIL B 5 mm slotted holes for mounting on wall and ceiling 6 mm hole for mounting to Unistrut 26 mm for general installation 28 mm for general installation max 400 mm max 900 mm 55 max 400 mm max 900 mm DETAIL A 28 m for ge DETAIL B 5 mm slotted holes for 26 mm mounting on wall and ceiling for general installation Hinge 5 mm slotted holes for mounting on wall and ceiling Hinge max 900 mm BACK VIEW DETAIL A 450 mm max 400 A B max 400 mm DE VIEW max 900 mm 450 mm max 400 SIDE VIEW 7 Hinge fitting to unistrut It is possible to install the hinge fitting on a sub-structure of unistrut profiles. Use the holes for M6 on the plate. 2104 Hinge fitting Unistrut Unistrut Unistrut (not provided (not delivered by SC) SC) by Soft Cells) (not delivered by Unistrut nut M6 Unistrut Unistrutnut nut M6 M6 (not provided by Soft Cells) (not delivered by SC) SC) (not delivered by Push latch Pushlatch latch Push DIN 7991 M6 DIN DIN7991 7991M6 M6 (not provided by Soft Cells) (not delivered delivered by by SC) SC) (not 1123 Socket button head screw m5x12 1123 1123 Keeper Keeper Keeper 1113 1113 1113 Rhombus steel nut m5 Unistrut Unistrut Unistrut (not provided by Soft Cells) (not delivered delivered by by SC) SC) (not Unistrut nut M6 Unistrut Unistrutnut nutM6 M6 (not provided by Soft Cells) (not delivered delivered by by SC) SC) (not 1124 1124 Plate for the hinge 1124 1121 Soft Cells hinge 1121 1121 DIN 7991 7991 M6 M6 DIN DINdelivered 7991 M6 (not provided by Soft Cells) (not by SC) SC) (not delivered by 1123 Socket button head screw m5x12 1123 1123 1113 1113 Rhombus steel nut m5 1113 8 Wire Wire fitting is used only for ceiling installations. Pull the wire to move it upwards. Push the collar (item 1119) to release the wire and move the Soft Cells downwards. 2105 Wire fitting 1117 Ceiling mounting plate 1117 1118 1118 Ceiling mounting plate screw 1120 1120 Wire 1,8 with a lock 1119 1119 Tensioner 1111 1111 Washer 12x1 1112 1112 Set screw m5x16 1113 Rhombus steel nut m5 1113 9 min 110 mm Wire detail Front Fabric max 928 mm (first bracing when frame over 1000mm) 450mm max 400 52 SIDE VIEW Wire fitting (2105) 38,6 max 900 mm Bracing (1202) Front fa max 450 400 mm 52 min 110 mm max 928 mm (first bracing when frame over 1000mm) Depending on the type of absorbent 39 Front Fabric VIEW FROM BELOW max 400 mm BACK VIEW Wire fitting (2105) max 900 mm Bracing (1202) Depending on the type of absorbent max 400 mm Front fabric 39 VIEW FROM BELOW 10 Safety wire Safety wires are required for ceiling installations. They should also be applied for any situation where Soft Cells are installed 3m or more above floor level, measured from the highest point of the Soft Cells to the floor. Safety wires are attached to the Soft Cells panel by fastnening the eyestrap to the groove on the back of the panel. Three safety wires per panel should be installed placed on three different panel edges forming the largest possible triangle. 2109, 2110 and 2111 Safety wire system 1287 Ceiling hook 1284, 1285 and 1286 Safety wire w/carabiner hooks 400/1000/1600 mm 1283 Hexagon socket screw 1282 Eye strap 1258 Rhombus steel nut Safety wire location - examples item no. 1236 11
© Copyright 2026 Paperzz