HERE

polyplas
Clip-Line
Polyplas
I-Line
Clip-Line allows ease of fitting and speed of
assembly whilst its self-gripping design gives
additional protection.
Polyplas produce a package of profiles for partitioning,
particularly for the joining of glass edges (dry-joints).
I-Line, the original flush-fitting minimalist system,
achieves the highest aesthetic aims being clear, slim
and unobtrusive. I-Line is applied using laminated
clear acrylic adhesive tape.
I-Line and Clip-Line offer two separate but complementary styles
in a comprehensive range to cater for all market needs.
Both I-Line and Clip-Line are made from a glass-clear polymer which is tough, durable and can be fully re-cycled.
Suitable for use in single- and double-glazed systems, all I-Line and Clip-Line profiles are available to match glass thicknesses of 10, 10.8, 12 and 12.8mm.
polyplas
I-Line clear flush-fitting dry joints
Clip-Line clear dry joints
I-Line
I-Line plus
Profile
Glass Thickness
Order Code
Order Code
Profile
Glass Thickness
Order Code
180° 2-Way
10mm
10.8mm
12mm
12.8mm
I-100-01
I-108-01
I-120-01
I-128-01
I-100-51
I-108-51
I-120-51
I-128-51
180° 2-Way
10mm
10.8mm
12mm
12.8mm
C-100-01
C-108-01
C-120-01
C-128-01
90° 2-Way
10mm
10.8mm
12mm
12.8mm
I-100-02
I-108-02
I-120-02
I-128-02
I-100-52
I-108-52
I-120-52
I-128-52
90° 2-Way
10mm
10.8mm
12mm
12.8mm
C-100-02
C-108-02
C-120-02
C-128-02
90°
10mm
10.8mm
12mm
12.8mm
I-100-03
I-108-03
I-120-03
I-128-03
I-100-53
I-108-53
I-120-53
I-128-53
90° 3-Way
10mm
10.8mm
12mm
12.8mm
C-100-04
C-108-04
C-120-04
C-128-04
90° 3-Way
10mm
10.8mm
12mm
12.8mm
I-100-04
I-108-04
I-120-04
I-128-04
I-100-54
I-108-54
I-120-54
I-128-54
135° 2-Way
10mm
10.8mm
12mm
12.8mm
C-100-05
C-108-05
C-120-05
C-128-05
135° 2-Way
10mm
10.8mm
12mm
12.8mm
I-100-05
I-108-05
I-120-05
I-128-05
I-100-55
I-108-55
I-120-55
I-128-55
10mm
10.8mm
12mm
12.8mm
I-100-06
I-108-06
I-120-06
I-128-06
I-100-56
I-108-56
I-120-56
I-128-56
Abutment Joint
135° 2-Way
(angled cut glass)
forward thinking / traditional values
Product is supplied in 3 metre lengths and packed in capped tubes
for ease of storage and onward distribution.
Profiles for other glass sizes available on request.
t
+44 (0) 1299 827344
e
[email protected]
w www.polyplas.co.uk
polyplas
I-Line clear flush-fitting dry joints - Profile summary and installation guide.
I-Line
I-Line plus
Profile
Glass Thickness
Order Code
Order Code
180° 2-Way
10mm
10.8mm
12mm
12.8mm
I-100-01
I-108-01
I-120-01
I-128-01
I-100-51
I-108-51
I-120-51
I-128-51
10mm
10.8mm
12mm
12.8mm
I-100-02
I-108-02
I-120-02
I-128-02
I-100-52
I-108-52
I-120-52
I-128-52
10mm
10.8mm
12mm
12.8mm
I-100-03
I-108-03
I-120-03
I-128-03
I-100-53
I-108-53
I-120-53
I-128-53
10mm
10.8mm
12mm
12.8mm
I-100-04
I-108-04
I-120-04
I-128-04
I-100-54
I-108-54
I-120-54
I-128-54
10mm
10.8mm
12mm
12.8mm
I-100-05
I-108-05
I-120-05
I-128-05
I-100-55
I-108-55
I-120-55
I-128-55
10mm
10.8mm
12mm
12.8mm
I-100-06
I-108-06
I-120-06
I-128-06
I-100-56
I-108-56
I-120-56
I-128-56
90° 2-Way
90°
Abutment Joint
90° 3-Way
135° 2-Way
135° 2-Way
(angled cut glass)
forward thinking / traditional values
USER’S GUIDE TO SUCCESSFUL INSTALLATION
I-Line joints rely on a strong bond to the glass, which is best achieved by careful manufacture and
preparation of the glass surfaces in addition to applying as much initial joining force as can be
practicably achieved.
Following the good practices below is strongly recommended for complete satisfaction.
The glass sheets must be polished, with an arris or chamfer detail of 1.6 mm minimum.
The surfaces to be joined must be clean and dry.
We recommend the use of an aqueous/alcohol based surface cleaner (in sachets).
In order to enhance the strength of the bond, we also recommend the use of an
adhesion promoter or primer.
It is essential that the glass edges are free from moisture. Temperature variation should be
avoided as this can lead to a condensation layer developing, particularly in a ‘new build’ fit
out when high levels of moisture can be present.
The glass sheets must be well supported so that the joining edges are very well aligned.
The second glass sheet should be offered up to the first, then fully supported and slid into
final position, before removal of the protective liner from the tape. When the installer is
happy with the alignment, ease back the second glass, then remove the protective liner
and slide the glass back into its correct place.
The pressure sensitive nature of the adhesive tape requires that the joints be pressed
together as strongly as possible (ideally>20N/cm) in any given situation.
The ideal tape application temperature range is 210C to 380C. Initial tape application to
surfaces at temperatures below 100C is not recommended as the adhesive becomes too
firm to adhere readily. Once properly applied, low temperature is generally satisfactory.
As with all pressure sensitive adhesive systems, the bond strength increases with
time and approaches its ultimate value after around 72 hours at 210C.
The information provided above is given in good faith, but no responsibility can be accepted for glass
manufacturing tolerances or other adverse factors beyond the company’s control.
t
+44 (0) 1299 827344
e
[email protected]
w www.polyplas.co.uk