Temperature Transmitter Model HPT The Conax Model HPT is a low cost, 2-wire, non-isolated temperature transmitter for RTD sensors, and is designed to fit in our popular T11 model terminal head. The HPT housing has a removable base allowing access to the electronics for the purpose of temperature range changes, which are easily accomplished with plug-in resistors. Specifications Output SPAN 4-20mA, limiting @ <28mA Input RTD - 100Ω, 2 or 3 wire connection Input Span RTD: 20°C min., 500°C max. Burnout Detection Upscale, Standard Supply Voltage 8-38 VDC polarity protected Maximum Load Rmax = (V supply - 8V)÷ 20 mA Ambient Temp. -20°C to +70°C Humidity 0-95% RH, non-condensing Linearity RTD: Better than ±.05% of SPAN referred to sensor temperature Stability (for both ZERO and SPAN) RTD (100°C SPAN): .03% of SPAN/°C All specifications are subject to change without notice. Dimensions & Electrical Connections Dimensions are in inches (mm) 1.30 (33) (RTD) .300 (7.6) .165 (4.2) 1.73 (44) 1.10 (28) .71 Ordering Information Model: HPT – RTD– (32-500) – F Measurement Range Units (°F or °C) With Weatherproof, Cast Aluminum Head: Add Prefix: – T11 Example of complete Assembly with Sensor: RTD43W3-SS25-T11HPT -(32-500 F) -12.00” Represented By: For more information call Conax Buffalo Technologies at: 1-800-223-2389 ™ 2300 Walden Avenue Buffalo, New York 14225 FAX: 716-684-7433 • Phone: 716-684-4500 Toll free in the USA at 1-800-223-2389 www.conaxbuffalo.com • e-mail: [email protected] European Office PO Box 91 BOGNOR REGIS PO22 7JB, England FAX: +44 (0) 1243 587799 • Phone: +44 (0) 1243 587878 e-mail: [email protected] Temperature Transmitter HART® Smart Isolated 2-Wire Transmitter – Signal Transmission the Smart Way Model HST The Conax Model HST HART® Smart Isolated 2-Wire Transmitter features universal input capability in 3 variations to accept most of today’s process parameters: Thermocouples, RTDs, DcmV, Potentiometers, Resistance Sensors, DcmA, DCV, AC Amps, Frequency and Pulse. Model HST is fully software driven and all input parameters are programmable. An external hand-held programmer, an integral transmitter mounted programmer, or HART protocol hand-held enables on site calibration, and indication of process parameters. Other features of the Model HST include high precision linearization for thermocouple and RTD sensor inputs, inverse output capability, variable input signal damping, sensor breakdown indication, full display scaling capability, auto-zero input, and more. Heavy duty metal case construction and carefully designed input and output circuitry ensures a high degree of protection from adverse environmental conditions to maximize RFI/EMI immunity. Optional features include LCD display with integral programmer, hand-held programmer, and explosion-proof enclosure: CL I, GRPS B, C, D CL II, GRPS E, F, & G CL III Type 4X General Specifications Inputs TC - Types E, J, K, T, R, S, N, B, C. RTD - 2, 3, and 4-wire Pt-100, (DIN & NIST curves) Pt-200, Ni-100, Cu-10 and other RTDs. DC mV ±120.00mV input SPAN. Potentiometers - 100Ω to 20KΩ. Resistance - 2, 3, and 4-wire 0 to 600Ω. Optional: DCmA, DCV. Optional: AC-Volts, AC-Amps, Frequency/Pulse. Minimum Range None. Limited only by signal quality. Digital Resolution >17 bits Outputs 4-20mA isolated analog current loop, or Digital communication, HART® protocol. Supply 12-45 VDC (@ no load). Reverse polarity protected. Display (optional) 8x1 Character LCD indicator for programming and display of input and output parameters and status. General Specifications continue on inside cover. HART® Smart Communications Protocol Specification is a trademark of Rosemount, Inc. General Specifications, cont… Operating Conditions -20°C to +70°C. 0-95% RH, non-condensing Storage Temperature -55°C to +125°C Turn-On Time Within 4 seconds to rated response Response Time 0.5 seconds to 99% of reading (2 updates per second). Damping Factor Programmable 0.0 to 32.0 seconds Long Term Stability Better than ±0.1% of SPAN for 6 months Isolation 800 VDC or peak AC RFI/EMI Immunity Tested per SAMA PMC 33.1C from 20 to 1000 MHz and for field strength up to 30 V/m. C.M.R.R. >120db DC to 60 Hz Enclosure Extruded, anodized aluminum Dimensions 3.00” x 2.44” x 2.46” 3.00” x 2.44” x 3.00” (with programmer/display) (Hockey-puck housing. Suitable for mounting inside 3.5” diameter explosion-proof enclosures. All specifications are subject to change without notice. Performance Specifications Analog Output Resolution 0.025% of SPAN (±4µA) Analog Output (D/A) Linearity ±0.025% of SPAN Digital Sensor Linearization <±0.02°C for Pt-100 RTD <±0.1°C for thermocouples Cold Junction Compensation Automatically corrected to within <±0.3°C for all T/C types Temperature Stability Zero: <±0.003%/°C of SPAN Span: <±0.005%/°C of SPAN Supply Voltage Effect: <±0.001% per volt Calibration Automatic. Unit includes all of the calibration parameters. It performs periodic “ZERO”, “SPAN”, self-test, and auto calibration. No field calibration is required. Physical Dimensions & Electrical Connections Dimensions are in inches (mm) IHST OPTIONAL MAGNETIC SWITCHES FOR PROGRAMING THRU XP ENCLOSURE’S WINDOW. THERMOCOUPLE POTENTIOMETER DC MV Optional Programmer with Display 4-WIRE RTD 3-WIRE RTD 2-WIRE RTD (62) 2.44 HST PROGRAMMING PORT LOOP WIRING (76.2) 3.00 Input-Wiring Diagram OPTIONAL PROGRAMMER WITH DISPLAY (76.2) 3.00 (62.5) 2.46 (49) 1.93 35mm DIN RAIL 2.75” SNAP TRACK DIN RAIL ADAPTER Transmitter Mounting Arrangement Physical Dimensions & Electrical Connections Dimensions are in inches (mm) HART PROGRAMMER (REMOTE) POWER SUPPLY (123) 4.84 BELL 202 MODEM (70) 2.75 PLC / PC x (29mm) 1.14 Thick Hand Held Programmer Sample Loop showing the HST with both Analog and Digital Devices. Ordering Information Model: HST - 01 - H - K 01-T/C, RTD, mV, POT, RES 02-DCmV, DCmA, DC Volt 03- AC Volt/AMP/FREQ/Pulse A - Standard 4-20mA Output H - HART® + Analog Output Integral Display Option K - Integral Programmer/Display R - Programmer + Reed Contacts Represented By: For more information call Conax Buffalo Technologies at: 1-800-223-2389 ™ 2300 Walden Avenue Buffalo, New York 14225 FAX: 716-684-7433 • Phone: 716-684-4500 Toll free in the USA at 1-800-223-2389 www.conaxbuffalo.com • e-mail: [email protected] European Office PO Box 91 BOGNOR REGIS PO22 7JB, England FAX: +44 (0) 1243 587799 • Phone: +44 (0) 1243 587878 e-mail: [email protected] Temperature Transmitters Model DRT2-T/C & DRT4-T/C The Conax Model DRT2-T/C and DRT4-T/C are compact, DIN rail mounted transmitters for any thermocouple type. The units provide an output which is linear with respect to the thermocouple sensor’s mV input. The units are powered by standard industrial loop powered supply and provide a 4-20mA current loop output on a 2-wire transmitter system (DRT2-T/C) or any standard current or voltage output on a 4-wire system (DRT4-T/C). Specifications Input Any Thermocouple type Input Span 5mV Min. (20mV for rated accuracy) Output (DRT2-T/C) 2-Wire (DRT4-T/C) 4-Wire Current loop 4-20mA 0...1...4...20mA 0...1...2...5...10V Linearity 0.02% of SPAN (Ref. to mV input) Burnout Detection Upscale, Standard Reference Junction 1.0°C max. error over 0-50°C of operating ambient temp. Stability (20mV input) Zero: 1mV/°C or 0.01% of SPAN/°C Power Supply Range 24 VDC ±20%, polarity protected Adjustments ±25% on both ZERO and SPAN Operating Temperature -20°C to 70°C (0°F to 160°F) Mounting DIN rail 35 mm All specifications are subject to change without notice. Dimensions & Electrical Connections Dimensions are in inches (mm) Loop powered Current Monitor + DIN Rail (35 mm) 1 2 1 2 – Power Output Signal + – + – 3 4 1 2 3 4 3 4 1 2 3 4 DRT4-T/C TC-K (800-1200)C (4-20) mA 5 2.56 (65) 2.12 (54) 6 7 8 Thermocouple Input DRT2-T/C 2.34 (60) DRT2-T/C TC-J (0-350)F (0-10) V 5 6 7 8 0.94 (24) DRT4-T/C Ordering Information Model: DRT2 – K– (32-500) – F – (4-20)mA 2 = Loop Powered 4 = Four Wire Thermocouple Type Measurement Range Units (°F or °C) Output Range DRT2-T/C: 4-20mA DRT4-T/C: V or mA Output Units Represented By: For more information call Conax Buffalo Technologies at: 1-800-223-2389 ™ 2300 Walden Avenue Buffalo, New York 14225 FAX: 716-684-7433 • Phone: 716-684-4500 Toll free in the USA at 1-800-223-2389 www.conaxbuffalo.com • e-mail: [email protected] European Office PO Box 91 BOGNOR REGIS PO22 7JB, England FAX: +44 (0) 1243 587799 • Phone: +44 (0) 1243 587878 e-mail: [email protected] Temperature Transmitters Model DRT2-RTD & DRT4-RTD The Conax Model DRT2-RTD and DRT4-RTD are compact, DIN rail mounted transmitters for 2, 3, and 4 wire RTD sensors. The output is linear with respect to the sensor's temperature. The 4-wire input circuitry provides near perfect compensation for the effect of long leadwire resistance. The units are powered by standard industrial loop power supply and provide a 4-20mA output on a 2-wire transmitter system (DRT2-RTD) or any standard current or voltage output on a 4-wire system (DRT4-RTD). Specifications Input Pt-100, 2, 3, or 4-wire RTD. Other Pt, Ni, NiFe, Cu RTDs, available Input Temp Range -200°C (-328°F) to +850°C (1562°F) Input Span 20°C Min. to 800°C Max. Output (DRT2-RTD) 2-Wire (DRT4-RTD) 4-Wire Current loop 4-20mA 0...1...4...10...20mA 0...1...2...6...10V Linearity Better than 0.1%, referred to the sensor's actual temperature Lead Wire Error (4-Wire) (3-Wire) Negligible, for 4-Wire sensors Better than 100:1 compensation Temperature Stability <±0.01% of range/°F (100°C SPAN) Power Supply Range 24 VDC ±20%, polarity protected Adjustments ±25% on both ZERO and SPAN Operating Temperature -20°C to 70°C (0°F to 160°F) Mounting DIN rail 35 mm All specifications are subject to change without notice. Dimensions & Electrical Connections Dimensions are in inches (mm) Loop powered Current Monitor + DIN Rail (35 mm) 1 2 1 2 – Power Output Signal + – + – 3 4 1 2 3 4 3 4 1 2 3 4 DRT4-RTD Pt-100 (0-100)C (0-10) V (4-20) mA 5 2.56 (65) 2.12 (54) 6 7 8 RTD Input DRT2-RTD 2.34 (60) DRT2-RTD Pt-100 (0-350)F 5 6 7 8 0.94 (24) DRT4-RTD Ordering Information Model: DRT2 – RTD – 3 – (32-500) – F – (4-20)mA 2 = Loop Powered 4 = Four Wire No. of Wires of RTD Measurement Range Units (°F or °C) Output Range DRT2-RTD: 4-20mA DRT4-RTD: V or mA Output Units Represented By: For more information call Conax Buffalo Technologies at: 1-800-223-2389 ™ 2300 Walden Avenue Buffalo, New York 14225 FAX: 716-684-7433 • Phone: 716-684-4500 Toll free in the USA at 1-800-223-2389 www.conaxbuffalo.com • e-mail: [email protected] European Office PO Box 91 BOGNOR REGIS PO22 7JB, England FAX: +44 (0) 1243 587799 • Phone: +44 (0) 1243 587878 e-mail: [email protected] TM Temperature Transmitter PC Programmable DIN Rail Transmitter Model PDT-400 The Conax Model PDT-400 is a slim DIN rail mount programmable 2-wire transmitter, featuring a state-of-the-art microprocessor-based design that enables full configuration with user friendly configuration software. Standard Features • Full featured and highly accurate • No power supply needed to program • User-friendly software provides complete programmability of sensor type and input range • Linearized 4-20mA current loop output for sensor input • 2000 Volts I/O isolation • RFI/EMI protected, marked • Custom linearization in minutes • Dual sensor input capability All specifications are subject to change without notice. 1-800-223-2389 www.conaxbuffalo.com Configuration GENERAL SPECIFICATIONS All input types and range parameters are easily configurable with user-friendly technology. No power supply is required for programming. The PA-400 programming adapter and the graphic user interface software operate under Windows® operating systems through the PC’s RS232 serial port. Minimum Range 2 mV. Limited mostly by input signal quality. Output 4-20mA isolated loop powered. Supply Voltage 9-40 VDC (@ no load). Reverse polarity protected. Specifications Maximum Load Rmax = ( Vsupply - 9V) ÷ 20mA. INPUT CONFIGURATIONS Thermocouples Most standard types and all special types using customer defined tables and polynomials. RTD 2, 3, and 4 wire, Pt-100, Ni-110 and other RTDs. Includes Callandar-VanDusen adaptation and custom sensors linearization with user defined tables and polynomials. Operating Temperature -40˚ to +85˚C (-40˚F to 185˚F). Storage Temperature -55˚C to +125˚C (-67˚F to 257˚F) Humidity 0-95% RH, non condensing. Response Time 0.3 seconds, to 90% of input. (>3 updates per second). Damping Factors Programmable 0.0 to 64.0 seconds, to 0 - 120% of input range, using software interface. Better than ± 0.1% of span for 12 months. Stability PERFORMANCE SPECIFICATIONS Output Resolution 0.015% of span (2.5µA). I/O Isolation 2000 VDC or peak AC. Output (D/A) Linearity Better than 0.02% of output span. RFI Protection Sensor Linearization Better than 0.1˚C for RTDs. Better than 0.2˚C for T/Cs. <1% effect of span at 20-1000 MHz and at field strength of 20V/m. marked. Cold Junction Compensation Automatic to within ±0.7˚C for all T/C. Temperature Stability 0.015%/˚C combined ZERO and SPAN. Supply Voltage Effect <±0.003% per Volt. Calibration Automatic. Unit includes all of the calibration parameters. It performs periodic “zero”, “span”, self-test, and auto calibration. Input Linearity Better than 0.01% of span (mV input). Accuracy RTD 0.1˚C typical T/C 0.3˚C typical Ordering Information Model: TRANSMITTER, PDT-400 Programming Adapter (RS232) Model: PA-400 Windows® is a registered trademark of Microsoft Corporation. Represented By: For more information call Conax Buffalo Technologies at: 1-800-223-2389 ™ 2300 Walden Avenue European Office Buffalo, New York 14225 PO Box 91 FAX: 716-684-7433 • Phone: 716-684-4500 BOGNOR REGIS PO22 7JB, England Toll free in the USA at 1-800-223-2389 FAX: +44 1243 773050 • Phone: +44 1243 784060 e-mail: [email protected] e-mail: [email protected] w w w. c o n a x b u f falo.com • www. p a r t s d r aw e r. c o m ISO certification refers to Buffalo location. ©2002 Conax Buffalo Technologies Bulletin 6022 6/02 5M W A L L M O U N T T E M P E R AT U R E S E N S O R Room Ambient Temperature Monitoring Wall mount temperature sensors provide highly accurate measurement of room air temperature in industrial workspaces and commercial, industrial or apartment buildings. The RTD sensor is housed in an attractive enclosure that offers very stable readings. These units submit input to readouts and HVAC controls, and when combined with a data logging device, can provide a history for validation of room ambient temperatures. Wall mount temperature sensors are ideal for clean rooms, close tolerance machining centers, calibration/metrology laboratories and medical laboratories. The assembly field-mounts onto a standard single-gang electrical conduit box. Model WM1 sensor is a high accuracy, encapsulated, platinum, 100Ω @ 0˚ C, ±0.3˚ C, 0.00385 Ω/Ω/˚C coefficient RTD. Increased sensor accuracy of ±0.1˚ C is also offered. Progressive Description Example: Model WM2 sensor with Model HPT fixed range transmitter offers a 4-20mA output with an accuracy of 0.1% of SPAN typical, supply voltage 8-38 VDC, polarity protected. Typical room ambient temperature range is preset at 40˚ F to 90˚ F (4.4˚ C to 32.2˚ C). Model WM3 sensor with Model PTH-400 programmable transmitter features a state-of-the-art microprocessor design that enables full configuration with a Windows®-based PC and user-friendly software. This model offers a 4-20mA current loop output with an accuracy of 0.1˚ C typical. Typical room ambient temperature range is preset at 40˚ F to 90˚ F (4.4˚ C to 32.2˚ C). Programmable features allow the operator to change upon demand the upper and lower room temperature points (zero/span). WM3-43W3 (0/100F) / Model RTD Probe WM1 Probe only with terminal strip 43 - 100Ω RTD at 0˚ C WM2 With HPT fixed range transmitter WM3 With PTH-400 programmable transmitter 86 - 200Ω RTD at 0˚ C (Available on WM1 and WM3) 215 - 500Ω RTD at 0˚ C (Available on WM1 only) Sensor Accuracy W - Class B (±0.3˚ C @ 0˚ C) Transmitter Range Configuration 3 - 3-wire Required for types WM2 and WM3 only V - 1/3 Class B (±0.1˚ C @ 0˚ C. Available for RTD Probe 43 only) Note:Minimum span of HPT is 36˚ F (20˚ C) Unit ˚F ˚C (Required for types WM2 and WM3) 430 - 1000Ω RTD at 0˚ C (Available on WM1 only) ™ For more information call: 1 - 8 0 0 - 2 2 3 - 2 3 8 9 • e-mail: c o n a x b u f @ c o n a x b u f fa l o . c o m • visit our website: w w w. c o n a x b u f fa l o . c o m R E L AT E D P R O D U C T S A VA I L A B L E F R O M C O N A X B U F FA L O T E C H N O L O G I E S Conax Buffalo is leading the way in the Pressure and Vacuum Sealing Assemblies development of engineered solutions Conax manufactures a complete line of pressure/vacuum compression sealing glands for wires and probes. A wide range of standard products and virtually unlimited customized designs are available, all featuring the Conax-developed "soft sealant" technology. This technology offers unequalled adaptability to meet the application needs of any industry. Request Catalog 5001A. for today’s challenging applications in temperature sensing and pressure/ vacuum sealing. Our technical design and development staff has set engineering standards in these areas Temperature Transmitters for more than 40 years. Today we Conax Buffalo offers a variety of types of temperature transmitters including fixed range, isolated or non-isolated transmitters in hockey puck or DIN-rail styles; and programmable models in hockey puck, DIN-rail or Hart Smart protocol models. Request Bulletin #C505-19. manufacture more than 100,000 standard assemblies in our state-ofthe-art production facilities. In most cases, our wide variety of off-theshelf designs can be combined to meet the needs of your application. For those truly unique requirements, our engineers are ready to put their years of experience to work to design the perfect solution for your application. Many of our custom designs have now become industry standards. For further information on any of our industrial products or to Temperature Sensor Assemblies Conax temperature sensor assemblies feature a wide variety of termination heads, sheath materials, mounting styles, and accessories to meet the requirements of industrial thermocouple and RTD temperature sensing applications. Every Conax sensor delivers rugged, reliable service and precision performance. Request Bulletin #6002. High Temperature Thermocouple Assemblies Conax Buffalo High Temperature Thermocouple Assemblies are specially designed for durability and reliability in high temperature applications to 4200º F (2315º C). Such applications generally involve oxidizing, reducing, inert gas or contamination atmospheres that challenge the life of the thermocouple. Request Bulletin #6008. request the literature listed below, call Thermowells 800-223-2389, visit the Literature Proper selection of thermowells for the protection of your sensor assemblies in harsh environments can be a challenge in itself. Conax’s detailed thermowell catalog will guide you through the appropriate sizing and selection of our extensive range of thermowells. Request Catalog W-898-D. Selector section of our website at www.conaxbuffalo.com, or e-mail us at [email protected]. Call Conax Buffalo today at 1-800-223-2389! ™ 2300 Walden Avenue Buffalo, New York 14225 FAX: 716-684-7433 • Phone: 716-684-4500 1-800-223-2389 e-mail:[email protected] European Office PO Box 91 BOGNOR REGIS PO22 7JB, England FAX: +44 1243 773050 • Phone: +44 1243 784060 e-mail:[email protected] w w w. c o n a x b u f falo.com • www. p a r t s d r aw e r. c o m Conax Buffalo Technologies is a registered trademark of Conax Buffalo Technologies. Windows is a registered trademark of Microsoft Corporation.• ISO certification refers to Buffalo location. ©2002 Conax Buffalo Technologies Bulletin 6020 6/02 5M
© Copyright 2026 Paperzz