Intrusion Alarm Systems | B420 Ethernet Communication Module B420 Ethernet Communication Module www.boschsecurity.com The Conettix B420 Ethernet Communication Module is a communication device that manages secure, two-way IP communications over Ethernet networks for compatible control panels. Typical applications include: • Reporting and path supervision to a Conettix Communications Receiver/Gateway. • Remote administration and control with Remote Programming Software. • Connecting to building automation and integration applications. u Full 2-way IP alarm/event reporting with support for panel programming and control u 10/100Base-T Ethernet with DHCP or static IP support u 128-bit AES Encrypted Line Security (NIST-FIPS 197) u Plug and Play installation on most DHCP networks and available UPnP router configuration u Advanced configuration available by browser, either remotely, or by Auto-IP direct connection System overview The system overview diagram shows several available configuration options of a Conettix IP system. Items 1 through 3 are installed at the protected premises, while the remaining system components can be connected locally or remotely. 1 2 The B420 is built for a wide variety of secure commercial and industrial applications. Flexible endto-end path supervision, 128 bit AES encryption and anti-substitution features make B420 desirable for high security and fire monitoring applications. It is capable as a stand-alone path or it can be used in conjunction with another communication technology. For Fire Monitoring applications, the B420 meets UL864 and NFPA72 standards for Single Communication Technology with approved Bosch control panels. 4 13 3 12 5 8 10 6 9 11 7 2 | B420 Ethernet Communication Module 1. Compatible Bosch Control Panel LED Function 2. Data Bus Connection between the control panel and the B420 RX: 3. B420 Ethernet Communication Module Indicates when an inbound packet is received on the bus. 4. Ethernet Network Connection between B420 and the Ethernet network TX: Indicates when an outbound packet is transmitted on the bus. 5. Ethernet network, Local Area Network (LAN), Metropolitan Area Network (MAN), Wide Area Network (WAN), or Internet Heart [icon]: Indicates the system health of the B420 and its connection to the panel. 6. Ethernet Network Connection to the D6100i Communications Receiver 7. Conettix D6100i Communications Receiver/Gateway 8. Ethernet Network Connection to the D6680/ITS-D6682 (ITSD6682 shown) Ethernet Network Adapter 9. Conettix D6680/ITS-D6682 (ITSD6682 shown) Ethernet Network Adapter 10. Connection from ITS-D6682 to the COM4 Port on the D6600 Communications Receiver/Gateway 11. Conettix D6600 Communications Receiver/Gateway 12. Ethernet network connection between the host computer Ethernet network interface card (NIC) and the Ethernet network 13. Host PC running RPS, Automation, or the D6200 Programming Administrative Software Certifications and approvals US UL 365-Police Station Connected Burglar Alarm Units and Systems GV4 Series, GV3 Series UL 864-Control Units and Accessories for Fire Alarm Systems (including NFPA 72) GV4 Series, GV3 Series, FPD-7024 UL 1610-Central Station Burglar Alarm Units GV4 Series, GV3 Series FCC Part 15 Class A GV4 Series, GV3 Series, FPD-7024 CSFM-California Office of The State Fire Marshal GV4 Series, GV3 Series, FPD-7024 GV4 Series, GV3 Series, FPD-7024 Functions NIST FIPS-197 AES Certification (IP Communications) Conettix IP Communication The B420 uses Conettix IP protocol which supports: Region Certification USA CSFM • • • • • Full event code reporting and administration Flexible supervision intervals Resistance to Denial of Service attacks 128-bit AES encryption Anti-replay and anti-substitution Rotary Switch Addressing Use the rotary address switch to easily assign a bus address or setup for web configuration. Installation/configuration notes Compatibility Information Control Panels LEDs Three LEDs provide status and troubleshooting information about the Interface Module and its connection. GV4 Series GV3 Series IP Network Support Supports DHCP, UPnP, and Auto IP addressing by default, but can also be configured for Static IP networks. Easy Configuration For most DHCP network installations, the default settings of the B420 allow installation with no PC required. Universal Plug & Play (UPnP) supports automatic UDP port mapping for remotely programming a B420 behind a firewall, as well as http port mapping for web configurations. For customized settings, the B420 supports a full web configuration menu remotely, or by a direct Ethernet connection. The GV4 Series Control Panels can configure the B420 through the keypad, or through RPS. 7300-1615:0241 for use with D6600 receiver GV2 Series (version 7.06 or higher) D9412 (version 7.0 or higher) D7412 (version 7.0 or higher) D7212 (version 7.0 or higher) DS7400XiV4 (version 4.10 or higher) DS7220 (version 2.10 or higher) DS7240 (version 2.10 or higher) FPD-7024 (version 2.10 or higher) Applications RPS/RPS Lite: Supported on all compatible control panels. PC9000: Supported on D9412, D7412, D7212, G Series, GV2 Series and GV3 Series (version 8.05 only). IS2000: Supported on all G and GV Series control panels. 3 | B420 Ethernet Communication Module Mounting Considerations Mount the B420 inside the control panel enclosure using the standard three-hole pattern. Wiring Considerations The B420 connects to a control panel using a data bus connection and to an Ethernet network using a standard Category 5 or above Ethernet cable with an RJ45 plug. Parts included Quantit y Component 1 B420 Ethernet Communication Module 1 Hardware pack 1 Interconnect cable wiring 1 Quick Start Guide (hardcopy) 1 Literature (mini-CD) Technical specifications Environmental Considerations Relative Humidity Up to 93% non-condensing Temperature Operating 0° to +49°C (+32° to +120°F) Properties Board Dimensions: 2.49 in x 3.9 in x 0.6 in (63.3 mm x 101 mm x 15 mm) Power Requirements Current: 10Base-T Ethernet: 90 mA maximum 100Base-T Ethernet: 100 mA maximum Voltage: 12 VDC nominal Connectors Control panel: Option, SDI or SDI2 bus terminals- interconnect LAN/WAN: RJ-45 modular port (Ethernet) Cabeling Ethernet Cable: Category 5 or better unshielded twisted pair Ethernet Cable Length: 328 ft (100 m) max length Wiring Data Bus Wire Gauge: 18 AWG or 22 AWG Data Bus Wire Length: 500 ft (152 m) using 22 AWG wire Browser Support Internet Explorer 6+, Mozilla Firefox 3+ Ordering information B420 Ethernet Communication Module Creates two-way communications over Ethernet networks for compatible control panels. Order number B420 4 | B420 Ethernet Communication Module Represented by: Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 [email protected] www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com © Bosch Security Systems 2013 | Data subject to change without notice 2536990859 | en, V6, 01. Oct 2013 Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 [email protected] www.boschsecurity.asia China: America Latina: Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98 North IBP CEP 13065-900 Changning District, Shanghai Campinas, Sao Paulo, Brazil 200335 China Phone: +55 19 2103 2860 Phone +86 21 22181111 Fax: +55 19 2103 2862 Fax: +86 21 22182398 [email protected] www.boschsecurity.com.cn www.boschsecurity.com
© Copyright 2026 Paperzz