LATITUDE 32 DESIGN GUIDELINES April 2016 – Version 3 Final for Advertising VERSION CONTENT Version 1 (SUPERSEDED) DATE REVISION STATUS Latitude 32 Design September Requirements Part One and 2013 Part Two C REV 1 as amended by advertising March 2014 Advertised January 2014 Adopted March 2014 Superseded by Version 2 July 2014 Version 2 (SUPERSEDED) Latitude 32 Design Guidelines Part One and Part Two B and C August 2014 - Advertised August 2014 Not adopted Superseded by Version 3 April 2016 Version 3 Latitude 32 Design Guidelines Part One and Part Two A, B, C and D April 2016 - Draft for PDCC April 2016 Acknowledgements This text is published by LandCorp to provide information on the Hope Valley-Wattleup Redevelopment Project / Latitude 32. The particulars and plans in the document are believed to be correct at the time of publication but are subject to change without notice and are supplied for general information only. The information is provided in good faith, neither LandCorp nor its Directors, employees or agents give any warranty or accept any liability arising as a result of reliance upon the information contained herein. This disclaimer is subject to any contrary legislative provisions. THIS DOCUMENT HAS BEEN PREPARED BY URBIS FOR LANDCORP Contents Latitude 32 Design Guidelines ........................................................................................................................1 Latitude 32 Industry Zone ........................................................................................................................................................... 1 Key Objectives ............................................................................................................................................................................. 2 Design Guideline Development and Review......................................................................................................................... 2 Application of Design Guidelines ............................................................................................................................................. 5 Part One: Latitude 32 Design Principles .........................................................................................................6 1 1.1 1.2 Latitude 32 Design Principles .................................................................................................................................. 7 Estate Signage ................................................................................................................................................................. 7 Road Reserves.................................................................................................................................................................. 7 Part Two: Latitude 32 Design Criteria ..............................................................................................................8 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 Lot Specific Design Principles ................................................................................................................................. 9 Setbacks ............................................................................................................................................................................ 9 Site Layout and Building Orientation ......................................................................................................................... 11 Site Cover ........................................................................................................................................................................ 12 Built Form and Character ............................................................................................................................................. 13 Vehicle Requirements ................................................................................................................................................... 14 Lot Specific Signage ..................................................................................................................................................... 14 Fencing ............................................................................................................................................................................ 15 Energy Management and Lighting ............................................................................................................................ 15 Water Management ..................................................................................................................................................... 16 Landscaping .................................................................................................................................................................. 16 Buffers .............................................................................................................................................................................. 17 Levels ............................................................................................................................................................................... 19 Interfaces ........................................................................................................................................................................ 19 Part Three: Development Area Design Criteria ...........................................................................................21 3 3.1 3.2 Flinders Precinct ..................................................................................................................................................... 22 Flinders Precinct Design Criteria.................................................................................................................................. 22 Flinders Precinct Special Requirements Plan ............................................................................................................ 25 4 4.1 4.2 Development Area 2 ............................................................................................................................................. 26 Development Area 2 Design Criteria ......................................................................................................................... 26 Development Area 2 Special Requirements Plan ................................................................................................... 28 5 5.1 5.2 Development Area 3 ............................................................................................................................................. 29 Development Area 3 Design Criteria ......................................................................................................................... 29 Development Area 3 Special Requirements Plan ................................................................................................... 31 6 6.1 6.2 Development Area 4 ............................................................................................................................................. 32 Development Area 4 Design Criteria ......................................................................................................................... 32 Development Area 4 Special Requirements Plan ................................................................................................... 34 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 3 Appendices Appendix A: Road Reserves Appendix B: Application Form and Checklist Appendix B: Latitude 32 Design Guidelines Glossary Appendix C: Glossary Appendix D: Development Area Landscape Master Plans Figures Figure 1 Locality Plan .......................................................................................................................................................... 1 Figure 2 Development Area Plan ..................................................................................................................................... 4 Figure 3 Application flow chart ......................................................................................................................................... 5 Figure 4 Signage concept ................................................................................................................................................. 7 Figure 5 Application of setbacks .................................................................................................................................... 10 Figure 6 Built form demonstration of setbacks ............................................................................................................. 10 Figure 7 Site layout diagram ............................................................................................................................................ 11 Figure 8 Building orientation diagram ............................................................................................................................ 11 Figure 9 Examples of appropriate site layout and orientation .................................................................................. 12 Figure 10 Examples of appropriate signage ................................................................................................................... 14 Figure 11 Examples of appropriate fencing ................................................................................................................... 15 Figure 12 Examples of appropriate development within the McLaren Avenue Sector and McLaren Town Centre .................................................................................................................................................................. 24 Figure 13 Examples of setback requirements to noise buffer ...................................................................................... 27 Figure 14 Indicative Layout for lots subject to the Parmelia Gas Pipeline Buffer ..................................................... 33 Figure 15 Indicative Layout for lots subject to the Dampier to Bunbury Natural Gas Pipeline, the Parmelia Gas Pipeline and Gas Interchange Buffer .................................................................................................... 33 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 4 Latitude 32 Design Guidelines Latitude 32 Industry Zone The Hope Valley-Wattleup Redevelopment Project (herein referred to as Latitude 32), incorporating approximately 1,400 hectares of land, is strategically located within the Western Trade Coast (WTC) Figure 2. The WTC is made up of four estates, of which one is Latitude 32. Latitude 32 has been planned to complement the other estates within the WTC by supplying general and transport industrial land to support the strategic heavy and special industrial projects. Latitude 32 is located in close proximity to existing and planned service and transport infrastructure, including access to road, rail and sea and as such is able to support the continued growth of industry within Perth and greater Western Australia. These Design Guidelines provide “easy to apply” design principles and criteria ensuring a consistently high standard of development is maintained from the earliest buildings through to the final stages of development. Figure 1 Locality Plan The blend of well-designed buildings and quality landscaping will contribute to Latitude 32 being a pleasant working environment and should assist developers and owner occupiers to maintain their investment. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 1 Key Objectives The key objectives of the Design Guidelines are: ● To achieve an attractive and unified development by placing an emphasis on a combination of quality landscaping and well designed, functional and efficient buildings. ● To avoid unsightly and poorly planned developments to protect the investment of all developers and owners. Land use and development within Latitude 32 is governed by the provisions of the Hope ValleyWattleup Redevelopment Project Master Plan (the Master Plan), localised structure plans for each of the Development Areas and the Latitude 32 Design Guidelines. The development of Latitude 32 in key stages, allows for the release of land in accordance with market demand and the establishment and provision of essential infrastructure required to support each Development Area, and the wider industrial area in a co-ordinated manner. Design Guideline Development and Review The Latitude 32 Design Guidelines have been prepared in accordance with and for the purpose of Clauses 2.2 and 6.2.14, and adopted in accordance with Clause 2.4 of the Master Plan. These Design Guidelines apply to all development within Latitude 32. The Design Guidelines consist of a three part document: ● Part One: Latitude 32 Design Principles, sets out the design principles applicable to all development within Latitude 32. ● Part Two: Latitude 32 Design Criteria sets out the lot specific design criteria applicable to all lots within Latitude 32. ● Part Three: Development Area Design Criteria, sets out the lot specific design criteria applicable to lots within each Development Area (Refer Figure 2): – – – – – – – Part Three A: Part Three B: Part Three C: Part Three D: Part Three E: Part Three F: Part Three G: Flinders Precinct Development Area 2 Development Area 3 Development Area 4 Development Area 5 Development Area 6a Development Area 6b The Part One and Two provisions have been established, with Part Three provisions to be developed in conjunction with the structure planning of each Development Area. The Design Guidelines are advertised and adopted concurrently with the relevant Structure Plan. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 2 In the instance where there are inconsistencies between Part One or Part Two and the relevant Part Three text, Part Three shall prevail. The Design Guidelines include a glossary of specialist terms used within the text. These terms are in blue through the document and definitions can be found within Appendix B - Glossary. It is acknowledged that as Latitude 32 develops, drivers for development and needs of users may change. These changes may result in a provision(s) of the Design Guidelines may impact implementation, or no longer being relevant, due to the time lapse between preparation of the Design Guidelines and development occurring. As such, a review process is necessary to ensure the Design Guidelines remain relevant and allow for the activation of development in Latitude 32. The review process is to be undertaken by the Responsible Authority every 5 years. Amendments proposed to the Design Guidelines must be referred to the Responsible Authority for comment as required by Clause 2.4 of the Master Plan. It is intended the review will look at the provisions relating to Parts Two and Three, and will allow for the on-going flexibility and activation in development. The review must take into account the relevance of the provisions of the Design Guidelines to the current development context, and market requirements along with the outcomes seen through the build out of Development Areas to date. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 3 Figure 2 Development Area Plan LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 4 Application of Design Guidelines This document provides a guide for developers to assist in the design of public areas, buildings and associated lot layout to ensure a cohesive and functional industrial area, which provides appropriate levels of amenity. This document provides: ● Part One - design principles applicable to signage and road reserves across the estate. ● Part Two - design criteria on an overall estate basis. ● Part Three - design criteria specific to the relevant Development Area following structure plan approval. All criteria must be met to the satisfaction of the Responsible Authority. The design principles and criteria allow for flexibility in design and design layout, to allow for the unique requirements of each user. However a level of consistency is applied across the requirements, in order to provide quality landscaping, and well designed, functional and efficient buildings throughout the estate. Planning Applications must be assessed and determined by the Responsible Authority as per Figure 3. Figure 3 – Application flow chart LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 5 Part One: Latitude 32 Design Principles LATITUDE 32 DESIGN GUIDELINES VERSION 4 – APRIL 2016 6 1 Latitude 32 Design Principles The following provisions set out the general principles for development within Latitude 32, which are not specific to individual lots. The co-ordination of these design elements and principles will ensure consistency is achieved across Latitude 32. 1.1 Estate Signage Estate Signage must be designed and constructed in accordance with the following principles: ● Estate signage must be appropriately designed and located to not be excessive in quantity, scale or form. ● Locations for estate signage are mandated through the relevant structure plan and Special Requirements Plan for each Development Area (located in Part Three). ● Estate signage must incorporate the Western Trade Coast Logo, ‘Latitude 32 Industry Zone’ Logo and the Development Area name as per the concept design (Figure 4). Figure 4 – Signage concept 1.2 Road Reserves The treatments within road reserves are complementary to the Design Guidelines. Roads should generally be designed as per the specifications set out in Appendix A. LATITUDE 32 DESIGN GUIDELINES VERSION 4 – APRIL 2016 7 Part Two: Latitude 32 Design Criteria LATITUDE 32 DESIGN GUIDELINES VERSION 4 – APRIL 2016 8 2 Lot Specific Design Principles 2.1 Setbacks Development must be setback from boundaries in accordance with the following setback requirements outlined in Table 1, in order to ensure an appropriate and consistent streetscape interface is achieved. Figure 5 provides an example for application of setbacks and Figure 6 demonstrates a built form example of the setback requirements. 15m 21m CONDITIONS 15m MAXIMUM MAIN BUILDING MASS SETBACK 3m MINIMUM MAIN BUILDING MASS SETBACK MAXIMUM OFFICE SETBACK Primary Setback for lots which are NOT within a bushfire prone area MINIMUM OFFICE SETBACK Setback Requirements SETBACK Table 1 Unless otherwise specified, local distributor roads as identified within the relevant Special Requirements Plan in Part 2 are considered to be the primary frontage for all for all lots fronting onto them (including corner lots). The main building mass must be attached to the The main building mass must be setback a minimum office component. of 3m from the front façade of the office component. Primary Setback for lots which ARE within a bushfire prone area 3m* 15m* 15m# 21m# Lots which are located within bushfire prone areas are nominated on the relevant Special Requirements Plan in Part Three. *Office components may be located toward the rear of the site where it is necessary to locate outside the bushfire prone area requirements. and meet bushfire management Specific design criteria relating to the location of offices in this instance is provided in Part Three. #Where offices are located to the rear and the main building mass makes up the primary façade the design must incorporate one additional articulation element in as detailed within Building Form and Character. Secondary Setback – Corner Lots 3m Side and Rear Setbacks As per BCA requirements 6m 11m 16m Unless mandated within the relevant Special Requirements Plan the primary and secondary frontage on corner lots shall be determined by the proponent in consultation with the Responsible Authority. On a nil side setback, the external finish on the wall must provide a level of detail and interest where visible to adjacent lots or streets as detailed within Building Form and Character. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 9 Figure 5 Application of setbacks LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 Figure 6 Built form demonstration of setbacks 10 2.2 Site Layout and Building Orientation Site layout and building orientation, for lots not located within a Bushfire Prone Area, must be designed in accordance with the following requirements to allow for legibility, efficient use and safe operations on the site: ● Office / administrative areas, including the office component, must be designed as focal points to the front of the site (refer Figure 7 for an example), and must include a canopy or verandah over the main entrance facing the public street or parking area (canopies may encroach into the setback). ● Operational areas must be located to the rear of the site, behind the office / administrative area. ● Operational areas (including service, storage and bin areas) must be behind the front building line and screened from the street. ● On corner sites, buildings must be located and designed to address both street frontages (refer Figure 8 and Figure 9 for examples), with the priority to be the primary street frontage. ● Buildings must be oriented and/or designed to respond to passive solar design, prevailing winds, and encourage the use of natural light by: – Maximising north and south exposure; – Providing shading through awnings and landscape. Figure 7 Site layout diagram Figure 8 Building orientation diagram Note: For lots located within bushfire prone areas, site layout is to be consistent with the setbacks and associated conditions set out in section 2.2. In addition, sufficient separation of administrative and operational activities must occur in line with the intentions of this requirement. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 11 Figure 9 2.3 Examples of appropriate site layout and orientation Site Cover Developments must have an enclosed building footprint consistent with the following coverage requirements: SITE AREA COVERAGE REQUIREMENT / MINIMUM ENCLOSED BULDING AREA Sites up to 1ha 20% of the lot area Sites 1ha and above 10% of the lot area or 2000m² whichever is greater LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 12 2.4 Built Form and Character The design of buildings must reflect the following design characteristics to ensure a consistent, high quality standard of design throughout the estate: ● Front façades must address the primary street frontage and provide a corporate image and clearly identify the main entrance point. (1) ● Front façades must use no less than two (2) types of primary building materials to create variety and interest. (1) (3) (2) (2) ● Light coloured roof and wall materials are generally to be used to reduce heat gain. No less than three (3) colours must be incorporated into the design. (3) ● Solid walls should incorporate no less than two (2) horizontal or vertical elements such as banding or recessed walls to avoid unbroken expanses of blank wall. (4) ● Where visible from the street, side façades should be integrated into the design of the front façade through use of similar materials and colours. (3) (4) (4) ● Signage must be integrated into the building design. ● Where more than one building is proposed for a site, the design should be presented as an integrated site layout and development using complementary built form, materials and colour. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 13 2.5 Vehicle Requirements Crossovers, on-site manoeuvring and car parking must be designed to meet the proponents operational requirements whilst ensuring safe and efficient vehicle movements: ● All lots require the construction of a crossover. Subject to approval, additional access points may be constructed to facilitate the effective use of the land for the proposed purposes. Additional access may be approved if it can be demonstrated to the satisfaction of the Responsible Authority that the access points will not impact on the efficiency or safety of the road network. ● All vehicles must be able to enter and exit the site in forward gear. ● All vehicle parking must be provided for on-site and in accordance with the requirements set out within the Master Plan. ● Visitor and/or staff parking must be separated from operational areas such as truck manoeuvring areas, loading areas, hard stand and external storage. ● Design of car parking bays and manoeuvring areas must be in accordance with Australian Standard AS2890 and are to be constructed and sealed to the satisfaction of the Responsible Authority. 2.6 Lot Specific Signage Any signage proposed as part of the development shall be designed in accordance with the following (refer Figure 10 for photographic examples): ● Signage must be designed and located in accordance with the relevant laws or policies of the Responsible Authority to ensure a consistent and orderly approach to signage within the estate. ● Any signage attached to buildings must be integrated into the building design. ● One free standing pylon or composite sign is permitted per lot. Where there are multiple tenancies the sign may have one panel per tenancy. Figure 10 Examples of appropriate signage LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 14 2.7 Fencing All fencing proposed as part of the development shall be designed and constructed in accordance with the following (refer Figure 11 for photographic examples): ● Where installed, the required standard for front fencing on primary and secondary street frontages is 1800m high black garrison fencing. ● There must be 0.3m separation distance between fencing and underground services to avoid conflict in footings. ● Side and rear fencing is permitted to the standard of 1800mm high black PVC coated link mesh with black posts, fittings and gates. ● Barbed wire must not be installed forward of the building line. Figure 11 2.8 Examples of appropriate fencing Energy Management and Lighting In addition to the building orientation requirements, the following energy management criteria must be applied to promote energy efficiencies in design: ● The design of buildings must optimise natural lighting and cross-ventilation in accordance with local climatic conditions for heating and cooling of buildings. ● Energy consumption for developments must be in accordance with the relevant BCA JV3 requirements (certification of compliance required to be provided). ● External lighting must be contained within the site and not directed beyond the lot boundary in order to avoid adverse impacts on adjacent properties and passing motorists. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 15 2.9 Water Management ● Water management measures must be incorporated into the design as per BCA standards in order to ensure effects of rainfall events are managed to avoid adverse impacts on developments and natural areas. ● Landowners are encouraged to install rainwater tanks appropriately sized for the development to provide for water reuse in toilet and irrigation systems (if practical). ● Where industrial processes create liquid effluent or require wash down areas, the incorporation of on-site containment, management and appropriate disposal is required. 2.10 Landscaping Landscaping of each lot shall be in accordance with the following requirements: ● Landscaping must be incorporated into the design in order to allow for appropriate levels of amenity within the industrial area, integrating with the form and function of proposed developments to provide visually pleasing interfaces. ● A detailed landscape plan is to be provided with any Planning Application indicating all areas of soft and hard landscaping, and including materials and plants to be used. ● The area between the building and the street must incorporate landscaping and/or parking elements. A 3m soft landscaping strip must be provided adjacent to the front boundary. ● Soft landscaping is to be consistent with the water-wise species and densities listed within the planting list in Appendix D. The species list is to be a generic guide with formal approval of species to be at the discretion of the Responsible Authority at the time of detailed design. ● Where irrigation is required, watering of soft landscaping areas is to be provided by automatic, electronic controlled, drip irrigation systems. ● Shade trees must be provided within car parking areas at a rate of 1 per every 4 car parking bays on the site. ● Dry grass is permitted provided that no irrigation of these areas is required. ● Soil conditioner (humus) is to be used in all planted areas to help retain soil moisture and nutrients. All planted areas shall be mulched with 75mm thick mulch to help the water retention properties of the soil. ● No invasive plant species are to be planted within 100m of any Bush Forever site, Conservation Area or Key Natural Area. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 16 2.11 Buffers Design requirements in relation to specific buffers within Latitude 32 (as depicted on the relevant Special Requirements Plan) are set out as follows: 2.11.1 Gas Pipelines ● Lots within the 45m and 85m buffers required by the Dampier to Bunbury Natural Gas Pipeline, Parmelia Natural Gas Pipeline and the Gas Interchange must be designed to ensure: – All sensitive uses, being commercial or office developments are located outside of the applicable buffer. – Activities within the buffer are limited to hardstand, lay down, parking and storage and landscaping. – Any proposed development within the buffer must provide a Pipeline Risk Management Plan endorsed by the pipeline owner. 2.11.2 Waste Water Pump Station Odour sensitive land uses including, but not limited to, commercial and / or offices on sites surrounding waste water pump station sites, must remain outside of the 30m buffer to the wet well, located within waste water pump station facilities. 2.11.3 Western Power Easement All applications for the use and development of land affected by a Western Power easement shall be referred to Western Power for its consideration. Developers / designers are encouraged to liaise with Western Power’s Environment and Land Management Branch, prior to the preparation of plans for any development in the vicinity of any Western Power easement. Windows and openings on façades directly facing the easement are to be minimised. Where administrative buildings require windows and openings facing the easement, appropriate noise attenuation measures are to be imposed to negate potential acoustic effects from the power lines. 2.11.3.1 Requirements for 330kV Power Lines All development and subsequent use of land on lots, which are subject to the Western Power Easement, are subject to compliance with Western Power’s Standard Easement Conditions (refer to Western Power’s website for further information http://www.westernpower.com.au/network-projectsyour-community-easements.html). A summary of these is outlined below: ● Altering or disturbing the present level of the surface of the land within the easement except in the course of normal farming operations or otherwise with the prior written consent of Western Power on each occasion. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 17 ● Constructing, erecting or setting up of any building, structure or improvement within the easement other than a fence or trellis not exceeding two metres in height from the natural surface of the land, earthed to the satisfaction of Western Power in the case of a metallic fence or trellis. ● Constructing, erecting, setting up, improving, enlarging or altering any contour bank, fenced storm water drain or compensating basin, or fenced artificial lake within the easement without prior written consent of Western Power. ● Growing, cultivating or maintaining any vegetation exceeding one metre in height from the natural surface of the land within the easement. ● Stacking, placing or storing any material within the easement. ● Bringing within the easement any vehicle or machinery, which together with any attachment, aerial or accessory exceeds 4.5 metres in height from the natural surface of the land. ● Parking or leaving stationary within the easement any vehicle or machinery exceeding 2.5 metres in height from the natural surface of the land. ● Bringing onto or permitting to be brought onto the easement any explosives, flammable or unstable substance or material other than agricultural crops. ● Blasting or permitting any blasting within the easement. ● Carrying on or permitting to be carried on any activity or operation, which endangers the safety of the transmission works or the safe, efficient and continuous operation of those works. 2.11.4 Bushfire Prone Areas ● Lots within the bushfire prone area, being 100m from the edge of the nearest classified vegetation will need to be constructed to enhanced bushfire resilient standards to the degree necessary, eliminating the need for any Hazard Separation Zone to manage potential bushfire threats. Assessment of the proposed structures against the current provisions of any relevant Australian Standards and DFES requirements must be undertaken at the time of development. ● On lots located within 100m of classified vegetation, buildings (including offices) may be located outside of the bushfire prone area (100m) to reduce costs associated with achieving appropriate BAL levels. Where located toward the rear, offices must be located as close as possible to the front of the site. 2.11.5 Wetlands Lots within the vicinity Conway Road Swamp, Long Swamp, Hendy Road Swamp and Wattleup Swamp may be located within the 200m management buffer as depicted on the relevant Special LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 18 Requirements Plan. Special consideration of land uses is required for lots wholly or partially located within this buffer as per the Section 7.3.3 of the Master Plan, the Environmental Protection Act 1986 and Regulations 1987, and the Latitude 32 Biodiversity Strategy Review (Biodiversity Strategy Review). All development within the 200m wetland management buffer shall be referred to the Office of the Environmental Protection Agency for review. All development shall be required to demonstrate their appropriateness to be developed within the 200m wetland management buffer, and will be assessed against the following criteria: ● Type of development and operational activities to ensure compatibility and appropriateness for activities to be established within the wetland management buffer. Compatibility and appropriateness are to be determined via assessment against the information as set out within Clauses 7.3 and 7.4 of the Master Plan and the Biodiversity Strategy Review. ● Where a land use is listed or considered to be prescribed premises under Part V and Appendix B of the Environmental Protection Act 1986 and Regulations 1987 it is not considered to be appropriate to be established within the wetland buffer. ● Developments which include the storage, handling and/or management of dangerous goods and chemicals are not considered to be appropriate to be established within the wetland management buffer. ● The details of the operations of the developer and the past track record of environmental practises shall be provided to ensure the surrounding environment will not be compromised by the establishment of the development. ● A proposed management system must be provided to ensure development and operations are appropriate to be established within the wetland management buffer. ● All developments must include a closed system to ensure no offsite discharges occur. Additionally, all proposed development must be in accordance with the requirements of the Biodiversity Strategy Review (2015) and Water Management Strategy. 2.12 Levels Developments must comply with the levels identified within the relevant Development Area structure plan and the Latitude 32 Planning Policy 2.2 - Levels Planning. 2.13 Interfaces Design requirements in relation to specific interfaces within Latitude 32 are set out as follows: 2.13.1 Wetland and Bush Forever ● All lots within 100m of conservation areas and Key Natural Areas (wetlands and Bush Forever sites) must utilise planting that is non-invasive and preferably local provenance LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 19 species that provide habitat for fauna. All species must be approved by the Responsible Authority. ● Lots directly adjacent to conservation areas must provide appropriate protection through fencing and controlled access to these areas. ● Any earthworks or batters associated with development on lots adjacent the wetlands or Bush Forever site must be contained within the lot boundaries and outside of the 50m wetland management buffer. ● All hard edges (e.g. fire access) to wetlands shall be located outside of the 50m wetland management buffer. These edges shall be appropriately cleared and maintained. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 20 Part Three: Development Area Design Criteria LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 21 3 Flinders Precinct 3.1 Flinders Precinct Design Criteria The design criteria outlined below is to be read in conjunction with the Flinders Precinct Special Requirements Plan, refer Section 3.2. 3.1.1 Existing Development Existing development within Flinders Precinct, established in accordance with the Flinders Precinct Design Guidelines 2008 or 2011, shall retain existing use rights in relation to any inconsistencies with the design guidelines. Any modifications or improvements to the buildings must be undertaken in accordance with the requirements of Part Two of the Design Guidelines and the provisions set out below. 3.1.2 McLaren Avenue Sector The Flinders Precinct Special Requirements Plan notes lots which are located within the McLaren Avenue Sector. The clustering of small scale multiple industrial strata developments is encouraged within this area to enable a higher density of strata development to occur, and facilitate a greater number of businesses and associated employment densities in close proximity to the Town Centre. 3.1.2.1 Land Uses Land Uses within the McLaren Avenue Sector are to be consistent with those uses outlined within Table 1 of the Master Plan. 3.1.2.2 Setbacks The setbacks associated with the McLaren Avenue Sector vary from the general setbacks as follows: ● Primary setbacks: The front facade of the primary building shall be located between 5m and 16m of the primary frontage, allowing for parking to be located between the front facade and front boundary. ● Secondary setbacks: Buildings are to be located between 3m and 11m from the secondary frontage. 3.1.2.3 Site Coverage The minimum site coverage for the commercial area is to be 20% of the total lot area. 3.1.2.4 Building Orientation and Design ● Primary façades are to be designed and constructed in accordance with the provisions of Building Form and Character as set out in Part Two of the Design Guidelines. ● Secondary façades are to be integrated into the design of the primary facade and include one additional element of articulation as set out in Building Form and Character as set out in Part Two of the Design Guidelines, ensuring blank walls are avoided. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 ● Building heights within the McLaren Avenue Sector are limited to three (3) storeys. ● Buildings must have a direct relationship with the adjacent car parking areas. Clearly defined pedestrian pathways and entrances must be provided between car parking areas and building entrances. ● Materials within the McLaren Avenue Sector are to be of a high quality such as steel, glass, metal cladding, rendered brick or where appropriate sufficiently articulated concrete panels. All materials shall be generally consistent with those utilised in the surrounding area. ● Well defined entrances shall be provided to front façades in order to provide legibility and a focal point. 3.1.3 McLaren Town Centre The Flinders Precinct Special Requirements Plan notes lots which are located within the McLaren Town Centre. The McLaren Town Centre will form the central business community and commercial centre focus for the Flinders Precinct, providing a high level of social amenity for employees and visitors. 3.1.3.1 Land Uses Land Uses within the McLaren Town Centre are to be consistent with those uses outlined within Table 1 of the Master Plan. 3.1.3.2 Setbacks The setbacks associated with the McLaren Town Centre vary from the general setbacks as follows: ● Primary setbacks / Secondary setbacks: The front facade of the primary building may be located at a nil setback from the primary street frontage. 3.1.3.3 Site Coverage The minimum site coverage for the commercial area is to be 30% of the total lot area. 3.1.3.4 Building Orientation and Design ● Primary façades are to be designed and constructed in accordance with the provisions of Building Form and Character as set out in Part Two of the Design Guidelines. ● Secondary façades are to be integrated into the design of the primary facade and include one additional element of articulation as set out in Building Form and Character as set out in Part Two of the Design Guidelines, ensuring blank walls are avoided. ● Building heights within the McLaren Town Centre are limited to three (3) storeys. ● Buildings must have a direct relationship with the adjacent car parking areas. Clearly defined pedestrian pathways and entrances must be provided between car parking areas and building entrances. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 ● Materials within the Town Centre are to be of a high quality such as steel, glass, metal cladding, rendered brick or where appropriate sufficiently articulated concrete panels. All materials shall be generally consistent with those utilised in the surrounding area. ● Well defined entrances shall be provided to front façades in order to provide legibility and a focal point. 3.1.3.5 Landscaping Where development is not located at a nil setback, a 3m minimum landscaping strip shall be implemented along external boundaries (refer Figure 12 for examples). Figure 12 Examples of appropriate development within the McLaren Avenue Sector and McLaren Town Centre LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 3.2 Flinders Precinct Special Requirements Plan LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 25 4 Development Area 2 4.1 Development Area 2 Design Criteria The design criteria outlined below is to be read in conjunction with the Development Area 2 Special Requirements Plan, refer Section 4.2. 4.1.1 Interfaces The Special Requirements Plan notes lots within Development Area 2 which are subject to specific interface considerations: 4.1.2 Fremantle Rockingham Controlled Access Highway (FRCAH) ● Lots directly abutting the future FRCAH will not have any form of access/from to the road. All access and crossovers must be to the internal local road. ● All façades facing the future FRCAH shall be subject to the provisions set out in Building Form and Character, having particular regard to those provisions relating to front façades. ● The required standard for fencing on boundaries facing the future FRCAH is 1800m high black garrison fencing. ● All storage and lay down areas fronting onto the future FRCAH shall be screened through the use of landscaping and/or screening panels. Consideration must be given to the visual outlook from the future FRCAH. 4.1.2.1 Midland – Kwinana Railway Line ● Landscaping and/or screening is to be provided along boundaries which directly abut the rail reserve. Species and densities are to be consistent with the relevant Landscaping Master Plan in Appendix C and at the final discretion of the Responsible Authority. 4.1.2.2 Wattleup Road / Dalison Avenue Future Investigation Areas Lots identified within a FIA as shown on the Special Requirements Plan must comply with the applicable provisions of the relevant Development Area structure plan. 4.1.3 Buffers The Special Requirements Plan identifies lots within Development Area 2 which are subject to specific buffer considerations: 4.1.3.1 Railway Buffers ● Vibration – 15m setback to development from the edge of the rail corridor. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 26 ● Noise – Where possible offices should be located outside of the railway noise contour (within the 70 - 75 dB(A) noise contour and above) in order to ensure compliance with AS 2107:2000 (refer Figure 13 for an example). – Lots within the noise buffer shall ensure office structures are designed, oriented and constructed from suitable materials in order to meet AS 2107:2000. Figure 13 Examples of setback requirements to noise buffer LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 27 4.2 Development Area 2 Special Requirements Plan LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 28 5 Development Area 3 The design criteria outlined below is to be read in conjunction with the Development Area 3 Special Requirements Plan, refer Section 5.2. 5.1 Development Area 3 Design Criteria 5.1.1 Interfaces The Special Requirements Plan notes lots within Development Area 3 which are subject to specific interface considerations: 5.1.1.1 Abercrombie Road / North South District Distributor Road (NSDDR) ● No direct vehicle access or egress to and from lots is permitted from the NSDDR. All access and crossovers must be to the internal Local Distributor Road or Local Road as specified on the Special Requirements Plan. ● All buildings must address the internal road network as the primary road. ● All façades facing the NSDDR shall be subject to the provisions set out in Building Form and Character, having particular regard to those provisions relating to front façades. ● All storage and laydown areas fronting onto the NSDDR shall be screened through the use of landscaping or screening panels. Consideration must be given to the visual outlook from the NSDDR. 5.1.1.2 Rural Interface Activities abutting or adjacent to rural lots (as depicted on the relevant Special Requirements Plan) shall minimise any significant effects of industrial activities on the use and enjoyment of the rural land and demonstrate compliance with the following: ● All buildings and operational areas must be set back a minimum of 5m from the shared boundary. ● Visual and/or acoustic screening must be provided to all direct interfaces. This screening can be achieved through placement of the building (where appropriate), screening panels, and landscaping adjacent to the shared boundary. Consideration must be given to the visual outlook created by the screening on the adjacent lot. ● Proposed land uses and activities in this area must demonstrate that there will be no significant adverse impacts such as visual, noise, dust, or vibrations, on rural properties. 5.1.2 Buffers The Special Requirements Plan notes lots within Development Area 3 which are subject to specific buffer considerations. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 29 5.1.2.1 Alcoa Buffer ● Lots within the 50m buffer from the Alcoa operations are subject to the following requirements to reduce and mitigate potential noise, dust and engineering impacts: – Visual and acoustic screening in association with landscaping must be provided to office uses or external recreation areas to provide screening from activities associated with Alcoa processes. – Any excavation or piling within the buffer is must be maintained on site and engineered to maintain stability of lots and the Alcoa residue lakes. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 30 5.2 Development Area 3 Special Requirements Plan LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 1 31 6 Development Area 4 6.1 Development Area 4 Design Criteria The design criteria outlined below is to be read in conjunction with the Development Area 4 Special Requirements Plan, refer Section 6.2. 6.1.1 Interfaces The Special Requirements Plan notes lots within Development Area 4 which are subject to specific interface considerations: 6.1.1.1 Phillips Road / North South District Distributor Road (NSDDR) ● No direct vehicle access or egress to and from lots is permitted from the NSDDR where an alternative access point can be achieved. ● All buildings must address the internal road network as the primary road. ● All façades facing the NSDDR shall be subject to the provisions set out in Built Form and Character, having particular regard to those provisions relating to front façades. ● All storage and laydown areas fronting onto the NSDDR shall be screened through the use of landscaping or screening panels. Consideration must be given to the visual outlook from the NSDDR. 6.1.2 Setbacks (for those lots subject to Pipeline and Gas Interchange Buffers) Lots directly to the west of the Dampier to Bunbury Natural Gas Pipeline, Parmelia Natural Gas Pipeline and Gas Interchange as denoted on the Special Requirements Plan are subject to the following requirements / variations to the Part Two requirements in order to respond to existing constraints: ● Warehouse buildings may be setback a minimum of 5m from the front boundary provided that where warehouse buildings are located forward of 15m, the following requirements are met: – A minimum of three (3) types of building materials are incorporated into the facades of both the office and warehouse components – Solid walls must incorporate no less than two (2) horizontal or vertical elements such as banding or recessed walls to avoid unbroken expanses of blank wall. – Car parking is to be located directly behind the office and or warehouse with provisions for suitable and safe access to buildings. Lots within the 45m and 85m buffer are subject to the following streetscape setback variations in order to respond to constraints created by the pipeline buffers: LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 32 ● Figure 14 – Where the easement is located at the primary street frontage, office and or warehouse buildings must be located at 50m from the primary street frontage (45m from the edge of the pipeline corridor), refer Figure 19. – Where the buffer is located to the rear boundary, office and or warehouse buildings must be located to a maximum of 5m from the primary street frontage, refer Figure 20. – Car parking areas shall be located directly in front of the administrative component. Lots within the 45m and 85m buffer are subject to the following site layout and building orientation variations: – Operational areas may be located forward of the administrative areas provide: – Operational areas must be setback a minimum of 10m from the front boundary. – Appropriate and clearly marked administrative areas is provided. – Any operational areas forward of the administrative area must be screened from the road frontage through screen panels and landscaping. Indicative Layout for lots subject to the Parmelia Gas Pipeline Buffer LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 separation Figure 15 of operational areas is from Indicative Layout for lots subject to the Dampier to Bunbury Natural Gas Pipeline, the Parmelia Gas Pipeline and Gas Interchange Buffer 33 6.2 Development Area 4 Special Requirements Plan LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 34 Appendix A: LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 Road Reserves 35 Cross Sections Note: The cross sections provided demonstrate an indicative configuration which may vary between Development Areas. Please refer to the relevant Structure Plan for the final cross sections relating to each particular Development Area. District Distributor Road (Anketell Road to Rowley Road) The following specifications shall be incorporated into the design and construction of all District Distributor Roads within Latitude 32: District Distributor Road (Anketell Road to Rowley Road) cross section District Distributor Road (Dalison Avenue to Russell Road) cross section LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 36 ASPECT SPECIFICATION Road Paving Minimum sealed carriageway width of 8.5m in each direction including traffic lanes (2x 3.5m) and shoulders (1.5m) at a maximum 3% grade separated by a planted median (width dependant on location along road) and bordered by a 4.5m verge on each side. Constructed from black/grey asphalt (bitumen) to the construction standards required by the local authority. Line marking is to be in accordance with local authority standards. The colour and texture of the shoulder shall vary distinctly from the carriageway and to be consistent with the colour and materials used in surrounding areas. Footpath Minimum of 3.0m on either edge of the road at a 2% grade constructed of Paving concrete with a brushed finish to local authority specifications. Coloured concrete may be permitted where it is consistent with adjacent development. Where street furniture is to be located on the footpath a minimum of 1.2m of unobstructed path shall remain clear. Where the footpath abuts a retaining wall the path shall be extended to the retaining wall. Lighting Australian Standard 1158.1.1 Category V2 250W sodium luminaries on 10.5m high aluminium poles at 55m spacing (for underground power) or 9m high aluminium poles at 50m spacing (for overhead power). The use of compact fluorescent luminaries is encouraged and may be installed with the approval of Western Power. Signage Limited to street name signs or signs referencing community facilities. To be installed at a height of 2500mm-3000mm on light poles wherever possible. Where it is not possible to be installed on light poles signage shall be installed on 3600mm 50NB pipe of stainless steel or galvanized metal. Sign dimensions are to be 200mm in height with a blade suitable for the length of the street name, and inclusive of 270mm for the local authority logo (to be aligned to the top of the street name text). Lettering is to be 100mm Helvetica Med. Condensed - Class 2 Blue on a Class 2 White double sided reflective blade. Landscape All landscaping must be waterwise and in accordance with the species listed within the relevant Landscape Master Plan for each Development Area and/or as approved by the local authority. Median: Where a central median is included within the road reserve street trees are to be spaced every 5m. Medians may contain dry planted groundcover or dry grass. Verge: Street trees are to be spaced every 5m. Only dry grass is permitted to be planted within verges (no groundcovers or shrubs). LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 37 Local Distributor Road (LDR) with Ecological Linkage The following specifications shall be incorporated into the design and construction of all LDRs with Ecological Linkages within Latitude 32: Local Distributor Road with Ecological Linkage cross section ASPECT SPECIFICATION Road Paving Minimum sealed carriageway width of 5.5m in each direction, including traffic lanes (4m) and shoulders (1.5m) at a maximum 3% grade separated by a 5m planted median and bordered by a 2.7m verge to one edge and a 2.0m verge to the other edge. Constructed from black/grey asphalt (bitumen) to the construction standards required by the local authority. Line marking is to be in accordance with local authority standards. The colour and texture of the shoulder shall vary distinctly from the carriageway and to be consistent with the colour and materials used in surrounding areas. Footpath Paving Minimum of 2.5m shared path shall be provided to one edge of the road, with a 1.8m path on the other edge. Footpaths shall be constructed at a 2% grade constructed of concrete with a brushed finish to local authority specifications. Coloured concrete (red asphalt) may be permitted where it is consistent with adjacent development. Where street furniture is to be located on the footpath a minimum of 1.2m of unobstructed path shall remain clear. Where the footpath abuts a retaining wall the path shall be extended to the retaining wall. Lighting Australian Standard 1158.1.1 Category V5 150W sodium luminaries on 10.5m high aluminium poles at 55m spacing (for LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 38 underground power) or 9m high aluminum poles at 50m spacing (for overhead power). The use of compact fluorescent luminaries is encouraged and may be installed with the approval of Western Power. Signage Limited to street name signs or signs referencing community facilities. To be installed at a height of 2500mm-3000mm on light poles wherever possible. Where it is not possible to be installed on light poles signage shall be installed on 3600mm 50NB pipe of stainless steel or galvanized metal. Sign dimensions are to be 200mm in height with a blade suitable for the length of the street name, and inclusive of 270mm for the local authority logo (to be aligned to the top of the street name text). Lettering is to be 100mm Helvetica Med. Condensed - Class 2 Blue on a Class 2 White double sided reflective blade. Furniture Street furniture shall be limited to that required for the efficient operation of the estate and provision of amenity for employees. All street furniture shall be hardwearing, constructed of materials and finishes consistent with the surrounding development and shall be finished in an anti-graffiti coating. Landscape All landscaping must be waterwise and in accordance with the species listed within the relevant Landscape Master Plan for each Development Area and/or as approved by the local authority. Median: Contains the 5m Ecological Linkage and provides a vegetation stratum of an over-storey, mid-storey and understory for a broad range of avifauna, bats and fauna. Medians may contain dry planted groundcover or dry grass. Verge: Street trees are to be spaced every 5m. Only dry grass is permitted to be planted within verges (no groundcovers or shrubs). LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 39 Local Road with Ecological Linkage The following specifications shall be incorporated into the design and construction of all Local Roads which incorporate an Ecological Linkage within Latitude 32: Local Road including Ecological Linkage cross section ASPECT SPECIFICATION Road Paving Minimum sealed carriageway width of 5.5m in each direction including traffic lanes (4m) and shoulders (1.5m)at a maximum 3% grade bordered by a 2.7m dual use parking and planting strip on one edge and a 2.7m verge on the other. Constructed from black/grey asphalt (bitumen) to the construction standards required by the local authority. Line marking is to be in accordance with local authority standards. The colour and texture of the shoulder shall vary distinctly from the carriageway and be consistent with the colour and materials used in surrounding areas. Footpath Paving Minimum of 1.8m on either edge of the road at a maximum 2% grade constructed of concrete with a brushed finish to local authority specifications. Coloured concrete may be permitted where it is consistent with adjacent development. Where street furniture is to be located on the footpath a minimum of 1.2m of unobstructed path shall remain clear. Where the footpath abuts a retaining wall the path shall be extended to the retaining wall. Lighting Australian Standard 1158.3.1 Category P3 70W metal halide luminaries on 6.5m high aluminium poles at 60m spacing (for underground power) or 40m spacing (for overhead power). The use of compact fluorescent luminaries is encouraged and may be installed with LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 40 the approval of Western Power. Signage Limited to street name signs or signs referencing community facilities. To be installed at a height of 2500mm-3000mm on light poles wherever possible. Where it is not possible to be installed on light poles signage shall be installed on 3600mm 50NB pipe of stainless steel or galvanized metal. Sign dimensions are to be 200mm in height with a blade suitable for the length of the street name, and inclusive of 270mm for the local authority logo (to be aligned to the top of the street name text). Lettering is to be 100mm Helvetica Med. Condensed - Class 2 Blue on a Class 2 White double sided reflective blade. Furniture Street furniture shall be limited to that required for the efficient operation of the estate and provision of amenity for employees. All street furniture shall be hardwearing, constructed of materials and finishes consistent with the surrounding development and shall be finished in an anti-graffiti coating. Landscape All landscaping must be waterwise and in accordance with the species listed within the relevant Landscape Master Plan for each Development Area and/or as approved by the local authority. Parking nibs are to be constructed on both sides of the road at 8.3m centres and allowing for a minimum 6.3m opening. Each nib is to contain one street tree and is to be 100% mulched to the kerb/footpath. Verge: contains the 5m Ecological Linkage and provides a vegetation stratum of an over-storey, mid-storey and understory for a broad range of avifauna, bats and fauna. Medians may contain dry planted groundcover or dry grass. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 41 Local Road The following specifications shall be incorporated into the design and construction of all Local Roads which do not incorporate a green link within Latitude 32: Local Road cross section ASPECT SPECIFICATION Road Minimum sealed carriageway width of 11m including traffic lanes (4m)and shoulders (1.5m) at a maximum 3% grade bordered by a 2.7m dual use parking and planting strip on each side. Constructed from black/grey asphalt (bitumen) to the construction standards required by the local authority. Line marking is to be in accordance with local authority standards. The colour and texture of the shoulder shall vary distinctly from the carriageway and be consistent with the colour and materials used in surrounding areas. Paving Footpath Paving Minimum of 1.8m at a maximum 2% grade constructed of concrete with a brushed finish to local authority specifications. Coloured concrete may be permitted where it is consistent with adjacent development. Where street furniture is to be located on the footpath a minimum of 1.2m of unobstructed path shall remain clear. Where the footpath abuts a retaining wall the path shall be extended to the retaining wall. Lighting Australian Standard 1158.3.1 Category P3 70W metal halide luminaries on 6.5m high aluminium poles at 60m spacing (for underground power) or 40m spacing (for overhead power). The use of compact fluorescent luminaries is encouraged and may be installed with the approval of Western Power. Signage Limited to street name signs or signs referencing community facilities. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 42 To be installed at a height of 2500mm-3000mm on light poles wherever possible. Where it is not possible to be installed on light poles signage shall be installed on 3600mm 50NB pipe of stainless steel or galvanized metal. Sign dimensions are to be 200mm in height with a blade suitable for the length of the street name, and inclusive of 270mm for the local authority logo (to be aligned to the top of the street name text). Lettering is to be 100mm Helvetica Med. Condensed - Class 2 Blue on a Class 2 White double sided reflective blade. Furniture Street furniture shall be limited to that required for the efficient operation of the estate and provision of amenity for employees. All street furniture shall be hardwearing, constructed of materials and finishes consistent with the surrounding development and shall be finished in an anti-graffiti coating. Landscape All landscaping must be waterwise and in accordance with the species listed within the relevant Landscape Master Plan for each Development Area and/or as approved by the Responsible Authority. Parking nibs are to be constructed on both sides of the road at 8.3m centres and allowing for a minimum 6.3m opening. Each nib is to contain one street tree and is to be 100% mulched to the kerb/footpath. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 43 Appendix B: LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 Application Form and Checklist 44 Planning Application Form LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 45 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 46 Latitude 32 Design Guidelines Checklist Lot #:_____________________ Street Address: _________________________________________________ Development Area: ______________________________________________________________________ Applicant details: ________________________________________________________________________ Compliance with Design Criteria Design Criteria Applicant Checklist Relevant Authority Checklist Achieved Achieved Not Achieved Comments Setbacks Site Layout and building orientation Site Cover Building Form Character and Vehicle Requirements Signage Fencing Energy Management and Lighting Stormwater Management Landscaping Development Area – Specific Requirements Assessment Date: Signature: Approved Not Approved Variations: LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 47 Appendix C: Glossary LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 48 TERM DEFINITION Amenity means all those factors that combine to form the character of the area and include present and likely future amenity. means a change in the direction or depth of materials, either horizontally or vertically in order to provide a high level of visual interest to the facade. means the predominant bulk of buildings proposed on the site, e.g. warehouse buildings means areas identified through a bushfire assessment that are located within 100m of a bushfire risk area and are subject to additional construction considerations to maintain the safety of operations on the site. means signage located at the key entrance points to each precinct in order to provide locational information and a sense of legibility to Latitude 32. Estate signage shall include reference to Latitude 32, the Western Trade Coast and the specific precinct in which it is located. means colours such as creams, light greys and similar tones which demonstrate low solar absorbency in order to avoid significant heat gain in buildings. means the area forward of 22m adjacent to the primary frontage which is to be used for the purposes of the following uses: office, parking, landscaping and approved product display and pedestrian oriented activities. means the area located to the rear of the site (from 22m, behind the administrative component) utilised for the general operational/ industrial purposes associated with the land use. means the predominant building material as observed from the street frontage. Banding or recessed walls Building Mass Bushfire Prone Areas Estate Signage Light coloured roof and wall materials Office / Administrative Areas Operational Areas Primary building materials Primary Setback means the setback to the primary street frontage as depicted on the special requirements plan or as agreed with the Responsible Authority. Secondary Setback means the setback to the secondary street frontage, being the frontage that is not deemed to be the primary frontage as per the above. Setback Range means the distance in which the front facade of a building (office or main building mass) can be located from the front boundary. Where a setback range between 15m-21m is applied the front facade may not be located forward of 15m, or backward of 21m. Any distance wtihin the range is acceptable in order to provide flexibility for varying operational requirements. Streetscape means the relationship between the front facade, landscaping and public areas of a site and the adjacent public realm. The interface streetscape interface assists in defining spaces and creating positive environments within the industrial estate. LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 49 Appendix D: LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 Development Area Landscape Master Plans 50 Landscape Master Plan – Development Area 2 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 51 Landscape Master Plan – Development Area 3 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 52 Landscape Master Plan – Development Area 4 LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 53 Species List – Plant Matrix LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 54 Species List – Plant Imagery LATITUDE 32 DESIGN GUIDELINES VERSION 3 – APRIL 2016 55
© Copyright 2026 Paperzz