Bills of Quantities for Electrical Installation Works Item ELECTRICAL SERVICES -SASRA OFFICES Description Qty Unit 300 80 20 No. No. No. 40 10 8 4 4 No. No. No. No. No. 8 No. 20 No. 20 No. 100 No. Rate Kshs Cost Kshs EIGHTEEN FLOOR A B C D SUPPLY, DELIVER, INSTALL, TEST AND COMMISSION THE FOLLOWING:LIGHTING POINTS Lighting points wired in 3x1.5mm2 sc pvc copper cables drawn in 20mm diameter heavy gauge pvc conduits conceled in building fabric including all accessories but without lighting switches and fittings for: i) One way switching ii) Two way switching iii) Two way with intermediate switching SWITCHES 10A, moulded plastic ivory white switch plates as Crabtree or approved equivalent as follows:i) One gang one way ii) Two gang one way iii) One gang two way iv) Two gang two way v) Intermediate 10A, moulded ivory white architrave switch plates as MK Range or approved equivalent as follows:i) One gang one way LIGHT FITTINGS Lighting fittings complete with lamps of appropriate wattage and colour rendering and fixing materials as follows:i) 1200mm, 1x36W IP65 rated dust and moisture resistant flourescent fitting with injection moulded GRP Canopy and Polycarbonate diffuser and stainless steel toggles as THORN IMPACT RESIST ii) 1200mm, 2x36W IP65 rated dust and moisture resistant flourescent fitting with injection moulded GRP Canopy and Polycarbonate diffuser and stainless steel toggles as THORN IMPACT RESIST iii) Circular Surface Luminaire fitting with Polycarbonate Body and trim and opal diffuser and control gear for 28W 2D lamps as THORN Club CAT No. or Approved Equivalent 0 Sub total C/F to the Next page H/3 Bills of Quantities for Electrical Installation Works Item A B C D Description Sub total B/F fro the previous page iv) 600X600MM, 4X18W Recessed Modular flourescent fitting for use in Standard Concealed Fix with low brightness louvres as THORN QUATRO LINE or Approved Equivalent Self-contained single sided EXIT sign with 8W fluorescent lamp for non-maintained emergency lighting for 3 hour duration as Thorn EF X3 or approved equivalent. POWER POINTS Raw power socket outlet power points comprising wiring in 3 x 4mm2 PVC/SC CU cables drawn in 25mmØ concealed HG PVC conduits/trunking including all conduit accessories but excluding plates SOCKETS 13A moulded switched socket outlet plates as Crabtree or approved equivalent as follows: i) Single switched ii) Twin switched Hand drier power points comprising wiring in 3 x 4mm2 PVC/SC/CU cables drawn in 25mmØ HG/PVC conduits complete with all necessary accessories Qty Unit 260 No. 4 No. 300 No. 40 250 4 No. No. No. 20A, DP control switch with neon light and cord outlet for item above as Crabtree or approved equivalent 14 No. E Floor mounted pedestal for workstations capable of accomodating 4No. Data/Telephone points & 4No. Twin switched socketsemi-circular outlet points profile fabricated and finished to Floor mounted metal trunking complete with all accessories As Manufactured by Power Technics 100 X 50mm Deep Powder coated metal trunking complete with bends As Manufactured by Power Technics Air Conditioning Unit power point comprising wiring in 5 x 10mm2 PVC/SC/CU cables drawn in Trunking/50mmØ concealed HG PVC conduits 32A TPN Isolator switch for item No 2.16 above as Crabtree or approved equivalent 10 No. 100 LM 150 LM 7 No. 7 No. G H L Cost Kshs 0 G F Rate Kshs 0 Sub total C/F to the Next page H/4 Bills of Quantities for Electrical Installation Works Item A B C D E Description Qty Sub total B/F fro the previous page Horizontal Data Cabling 48 port RJ45 cat 6 data patch panel for UTP termination as 2 No. Siemons B1:B15 or approved equivalent. 1M RJ45-RJ45 Cat 6 UTP factory terminated patch cord as 120 No. Siemons or approved equivalent to be used in cabinet. Cable manager 6 No. Cat 6 UTP 4-pair cable as Siemons or approved equivalent 12,240 M . 3M RJ45-RJ45 Cat 6 UTP factory terminated patch cord as 120 No. Siemons or approved equivalent to be used at work station. F RJ45 Cat 6 UTP (Dual) outlet complete with faceplate and labeling system as Siemons or approved equivalent. Active Components G 48 port CISCO Switch, as described in particular specifications. H 250mm x 50mm deep two compartment metal trunking constructed from heavy gauge powder coated steel, and shall be complete with all accessories for 2 coupling and earthing including all trunking accessories. I Supply, install, test and commission an IP PABX equipped as specified in section ‘‘F’.’ J Supply, install, test and commission a battery set for the E.P.A.B.X. above with enough capacity to serve all auxiliary equipment linked to the E.PA.B.X. for a period of minimum 8 hours . K Supply, install, test and commission an AC Voltage stabilizer for the E.P.A.B.X. and all auxiliary equipment. Connected to the E.P.A.B.X L Provide and independent telecommunication earth to the E.P.A.B.X and MDF M Supply, Install, Test and commision an MDF suitable for the ultimate size of the EPABX Machine above N Supply, Install, Test and commision a Modem for ISDN PRI for the PABX P Supply, install, test and commission Cisco 7942 unified IP phone complete with telephone cord and termination block as described in the technical Specifications section F Q Unit Allow for terminating, testing and Labeling all voice circuits. Sub total C/F to the Next page H/5 120 No. 3 No. 200 Lm 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 20 No. 1 Item Rate Kshs Cost Kshs Bills of Quantities for Electrical Installation Works Item Description Sub total B/F fro the previous page NINENTEEN FLOOR SUPPLY, DELIVER, INSTALL, TEST AND COMMISSION THE FOLLOWING:LIGHTING POINTS A Lighting points wired in 3x1.5mm2 sc pvc copper cables drawn in 20mm diameter heavy gauge pvc conduits conceled in building fabric including all accessories but without lighting switches and fittings for: i) One way switching ii) Two way switching iii) Two way with intermediate switching SWITCHES B. 10A, moulded plastic ivory white switch plates as Crabtree or approved equivalent as follows:i) One gang one way ii) Two gang one way iii) One gang two way iv) Two gang two way v) Intermediate C 10A, moulded ivory white architrave switch plates as MK Range or approved equivalent as follows:i) One gang one way LIGHT FITTINGS D Lighting fittings complete with lamps of appropriate wattage and colour rendering and fixing materials as follows:i) 1200mm, 1x36W IP65 rated dust and moisture resistant flourescent fitting with injection moulded GRP Canopy and Polycarbonate diffuser and stainless steel toggles as THORN IMPACT RESIST ii) 1200mm, 2x36W IP65 rated dust and moisture resistant flourescent fitting with injection moulded GRP Canopy and Polycarbonate diffuser and stainless steel toggles as THORN IMPACT RESIST iii) Circular Surface Luminaire fitting with Polycarbonate Body and trim and opal diffuser and control gear for 28W 2D lamps as THORN Club CAT No. or Approved Equivalent iv) 600X600MM, 4X18W Recessed Modular flourescent fitting for use in Standard Concealed Fix with low brightness louvres as THORN QUATRO LINE or Approved Equivalent Sub total C/F to the Next page H/6 Qty Unit 250 40 10 No. No. No. 40 10 8 4 4 No. No. No. No. No. 8 No. 10 No. 10 No. 50 No. 230 No. Rate Kshs Cost Kshs Bills of Quantities for Electrical Installation Works Item A B C D E F G Description Sub total B/F fro the previous page Self-contained single sided EXIT sign with 8W fluorescent lamp for non-maintained emergency lighting for 3 hour duration as Thorn EF X3 or approved equivalent. POWER POINTS Raw power socket outlet power points comprising wiring in 3 x 4mm2 PVC/SC CU cables drawn in 25mmØ concealed HG PVC conduits/trunking including all conduit accessories but excluding plates SOCKETS 13A moulded switched socket outlet plates as Crabtree or approved equivalent as follows: i) Single switched ii) Twin switched Hand drier power points comprising wiring in 3 x 4mm2 PVC/SC/CU cables drawn in 25mmØ HG/PVC conduits complete with all necessary accessories 20A, DP control switch with neon light and cord outlet for item above as Crabtree or approved equivalent Floor mounted pedestal for workstations capable of accomodating 4No. Data/Telephone points & 4No. Twin switched socket outlet points fabricated and finished to engineers specifications. Floor mounted semi-circular profile metal trunking complete with all accessories As Manufactured by Power Technics H 100 X 50mm Deep Powder coated metal trunking complete with bends As Manufactured by Power Technics I Air Conditioning Unit power point comprising wiring in 5 x 10mm2 PVC/SC/CU cables drawn in Trunking/50mmØ concealed HG PVC conduits J 32A TPN Isolator switch for item No 2.16 above as Crabtree or approved equivalent Horizontal Data Cabling K 48 port RJ45 cat 6 data patch panel for UTP termination as Siemons B1:B15 or approved equivalent. L 1M RJ45-RJ45 Cat 6 UTP factory terminated patch cord as Siemons or approved equivalent to be used in cabinet. M 42U cabinet Sub total C/F to the Next page H/7 Qty Unit 4 No. 200 No. 40 160 4 No. No. No. 14 No. 10 No. 200 LM 200 LM 7 No. 7 No. 2 No. 120 No. 2 No. Rate Kshs Cost Kshs Bills of Quantities for Electrical Installation Works Item Description Qty Unit 6 No. Sub total B/F fro the previous page A Cable manager B Cat 6 UTP 4-pair cable as Siemons or approved equivalent 12,240 M . 3M RJ45-RJ45 Cat 6 UTP factory terminated patch cord as 120 No. Siemons or approved equivalent to be used at work station. C D E F G RJ45 Cat 6 UTP (Dual) outlet complete with faceplate and labeling system as Siemons or approved equivalent. Active Components 48 port CISCO Switch, as described in particular specifications. 250mm x 50mm deep two compartment metal trunking constructed from heavy gauge powder coated steel, and shall be complete with all accessories for 2 coupling and earthing including all trunking accessories. 120 No. 3 No. 200 Lm Supply, install, test and commission Cisco 7942 unified IP phone complete with telephone cord and termination block as described in the technical Specifications section F 20 No. Total for electrical services H/8 Rate Kshs Cost Kshs
© Copyright 2026 Paperzz