Installation Guide — LAL Series Pendant Accessory

Installation Guide
GE
Lighting
Lumination LED Luminaires
TM
LAL Series Pendant Accessory Kit
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn off power before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
• Minimum size 18 AWG (0.75mm2).
• Type IC, inherently protected.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.75mm2).Minimum size 18 AWG (0.75mm2).
• Type IC, protection inhérente
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Provided in the Package
•
•
•
•
•
Pendant bracket (2)
Suspension cable (2)
8-18 x 3/8” screws for bracket installation (8 pieces)
AC line power cord and grommet
Dimming power cord and grommet
Tools and Components Required
• For end cover install: Philips headed screwdriver
• Rigid (RMC) or flexible (FMC) metal conduit for supply connection
• UL/cUL approved twist-on-wire connectors, min. 18 AWG
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 120-277 VAC, 60 Hz and connected to an
individual properly grounded branch circuit. Use min. 600V 75°C supply conductor.
Grounding Instructions
• The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes.
imagination at work
LAL Pendant Installation
Loop Method
• Form loop with aluminum sleeve for looping around
building structural member.
• Suitable for looping around building structural member
such as bar joists, strut, purlins, beams roof trusses, etc.
NOTE: Rigid conduit and appropriate conduit
fittings must be used according to local building
codes and safety regulations.
WARNING:
• Structural member must be strong enough to support
40kg [88 lbs].
• Do not suspend fixture near sharp edges.
WARNING
Risk of Injury. Improper mounting bracket installation
may cause injury or property damage.
Wiring Diagrams
Optional Installation: 1-10 Volt Dimming or DALI Lighting Controller
Follow diagram A for 1-10V, diagram B for DALI, diagram C for 347 VAC.
At output side of LED driver, make appropriate connections using twist-on wire connectors.
Follow lighting controller installation instructions.
Line (black)
Neutral (white)
Ground (green)
Line
Line (black)
Neutral
Neutral (white)
Ground
(1-10) + (violet)
(1-10V) -
Ground (green)
DALI 1 (violet)
DALI/(1-10V) +
(1-10) - (gray)
A
PSU
Line
Neutral
Ground
PSU
DALI/(1-10V) +
DALI 2 (violet/white)
B
1-10V wiring diagram
(1-10V) -
DALI wiring diagram
VIOLET (1-10V) +
GREY (1-10V) –
Light
Engine
+
–
RED
BLUE
PSU
347V Transformer
RED
+
Line BLACK
BLUE
–
Neutral WHITE
(1-10) + (violet)
(1-10) - (gray)
Ground (green)
Neutral (white)
Line (black)
CC
1-10V 347V wiring diagram
BLUE
Line RED
BLACK
Neutral BLACK
Installation
1
TURN OFF POWER at the source to the luminaire.
2
Carefully unpack unit from its packaging. Properly
inspect for defects before installing. Wear work
gloves to prevent dirt and oil from being transferred
to the luminaire.
Dimming line or
Additional branch circuit
Power feed canopy
(5” diameter)
Non-feed canopy
(2” diameter)
Junction box
in ceiling
AC line
Crossbar
3
Mark distance between canopy sets on ceiling
based on the size luminaire being installed (see
information at top of page).
4
Attach crossbar to junction box in ceiling with two
#8 screws (provided).
Stud
5-inch
powerfeed
Canopy
canopy
Cable
coupler
2-inch non-power
feed canopy
Slip ring
5
Pass cable through cable coupler and screw onto
stud. Pass cable through canopy and slip ring
(power canopy shown).
Cable
coupler
2nd cable
6
Hang second cable to a structural ceiling member
capable of supporting 44 pounds and cover with
non-power feed canopy.
Pendant Bracket Installation
When the pendant accessory kit is supplied the product must be installed by the following instructions.
1
Place bracket in top channels of the luminaire.
Use two per fixture. Use provided screws to attach
bracket to luminaire. Use two screws per bracket.
2
Use suspension cable to attach through hole in
bracket to connect to luminaire. Attach gripper
to pendant bracket through hole in bracket with
provided bolt and nut. Use suspension mounting
appropriate for ceiling type.
Squeeze tip to adjust
3
To adjust height and to level fixture, squeeze tip of
the gripper and pull the suspension cable to the
desired height. Clip the cable with cable cutters to
finish the appearance.
Wiring Dimming
Leader cable
1
Remove screws and knockout plate from
fixture. Remove holes from knockout plate to
make AC and dimming connections.
2
Connect leader cable to the AC line clipping
harness connectors together. Repeat for
dimming leader cable.
Dimming
wires
Strain relief
bushings
AC wires
3
Install cords using provided strain relief
bushings. Connect the black (line), white
(neutral), and yellow/green (ground)wires
from the luminaire to the matching
colored wires of AC cord. Connect the
gray and violet wires from the luminaire
to the matching colored wires of the
dimming cord.
4
Reattach knockout plate with cords
attached to fixture with screws.
NOTE: A red wire in the through wiring is
offered for an additional circuit as
needed. (See wiring note below).
Branch
Circuit 1
Control
Standard
Wiring Note
Line 2
Line
Neutral
Ground
(0-10) +
(0-10) -
AC wires
Red (optional)
Black
White
Green/Yellow
Violet
Grey
Dimming
wires
Strain relief
bushings
5
Connect the black (line) and white (neutral)
wires from the ceiling to the matching-colored
wires from the AC cord. Connect both green
wires to the grounding screw. Connect the
gray and violet wires from the luminaire to the
matching-colored wires from the dimming
circuit.
Troubleshooting
Symptom
Solution
Luminaire does not light
• Check input voltage and check power supply input/output connections.
• Check circuit breaker.
Luminaire is dim
• Dimming wire connection shall be checked and if connection is not proper, reconnect it.
If wire is harmed, replace it with an intact one. Also check that dimming wires are not in
short circuit.
Luminaire is blinking
• Ensure power supply temperature does not exceed its maximum rating.
• Refer to the tc point located on power supply.
Luminaire does not dim
• Check dimming wire connection.
Suspension method won’t
engage with luminaire
• Check that the suspension method is one of the approved types in the installation
instruction.
• Check if the steps for suspension were properly followed.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme á la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE.
IND308 (Rev 11/02/16)