Argon Product Catalogue 2013

Argon Product Catalogue 2013
Argon Medical Devices
Company History
Founded in 1972 in Garland, Texas, Argon Medical Devices is a global manufacturer and supplier of specialty
medical products headquartered in Plano, Texas, with manufacturing in both Texas (Athens) and Singapore
(Yishun).
Argon offers a broad line of medical devices for Interventional Radiology, Vascular Surgery, Interventional
Cardiology, and Critical Care procedures. Argon has successfully grown into a leading Global supplier of devices
to the healthcare marketplace and Argon’s brand is recognised for producing quality products at competitive
prices. Our newest products include the OptionTM Retrievable Inferior Vena Cava Filter, CleanerTM Rotational
Thrombectomy System, and UltraStreamTM Chronic Dialysis Catheters.
Following the acquisition of the BD (Becton Dickinson) Critical Care and Extended Dwell Catheter (EDC)
business in 2010, Argon also offers a range of pressure transducers and GabarithTM tested transducer sets,
PICC and Midline catheters, introducer sheaths, endomyocardial biopsy forceps, and other vascular products.
Argon’s established sales and marketing infrastructure serves a broad and diversified global Customer base
through both a direct sales force, and through long-standing relationships with OEMs, strategic partners, and
leading medical device distributors.
Argon History
1972
1981
1991
2003
2003
2010
2010
Argon founded in Garland, Texas by James Eddings to market a proprietary guidewire
Argon relocates to current manufacturing location in Athens, Texas
Introduced catheterisation lab introducers, JawzTM biopsy forceps,
Argon launched the 1StepTM Introducer
Argon device business acquired by RoundTable Healthcare Partners (RTHP)
RTHP increases the Argon portfolio of products through the acquisition of the Rex Medical Interventional
Radiology and Dialysis products (OptionTM IVC Filter, CleanerTM Mechanical Thrombectomy Device and
UltraStreamTM Chronic Dialysis Catheter).
RTHP further increases the Argon portfolio of products through the acquisition of the Becton Dickinson
(BD) Critical Care and Extended Dwell Catheter (EDC) Businesses
About Argon Critical Care and Extended Dwell Catheter products
With a long history and experience in invasive blood pressure monitoring dating back to 1946 with the introduction
of the first reusable transducer under the ‘Statham’ name, followed by such names as ‘Gould’, ‘Spectramed’
and ‘Ohmeda’, the current Argon GabarithTM tested disposable transducer technology is recognised globally as
a market leader for ease of priming, accuracy of pressure transmission, safe arterial blood sampling solutions
and unique safety features, protecting Clinical Staff and Patients alike.
Additionally, with single lumen central venous access devices such as SecalonTM T, and single/multi-lumen
CareflowTM Central Venous Catheters, Arterial Catheters, CriticathTM Pulmonary Artery Catheters and accessories
and First PICCTM & L-CathTM long term catheter products, Argon also offers a significant portfolio of Critical Care
and EDC solutions.
About RoundTable Healthcare Partners
RoundTable Healthcare Partners, Lake Forest, IL, is an operating-oriented private equity firm focused exclusively
on the health-care industry. RoundTable partners with companies that can benefit from its extensive industry
relationships and proven operating and transaction expertise. RoundTable has established a successful track
record of working with owner/founders, family companies, management teams, entrepreneurs and corporate
partners who share a vision and believe in the value creation potential of its partnership model.
More information about RoundTable Healthcare Partners can be found at: www.roundtablehp.com.
Contents
Argon Interventional Cardiology and Radiology Products
Option
CleanerTM
UltraStreamTM
JawzTM7
AxcessTM
1SticTM
MicroSticTM
Arterial Access
Guidewires
TM
Argon Fluid Management Systems
Manifolds and High Pressure Injection Lines
Control Syringes
Colour Coded Medication Syringes
Argon PICC and Midline Catheters
Extended Dwell Catheter Products
Introducers & Modified Seldinger Technique (MST) Introducer Sets
L-CathTM Polyurethane PICC and Midline Catheters
First PICCTM Silicone PICC and Midline Catheters
Argon Central Venous Catheters
Floswitch
Secalon TTM Catheters
CareflowTM Single Lumen Catheters
CareflowTM Single Lumen Sets Catheters
CareflowTM Double/Triple Lumen Catheters
CareflowTM Quad/Quint Lumen Catheters
Hydrocath AssureTM Antimicrobial Coated Catheters
TM
4
4
5
6
7
8
9
10
11
13
17
17
19
20
21
21
22
23
24
25
25
26
27
28
29
30
31
Argon CareflowTM Arterial Catheters
32
Argon Pulmonary Artery and Thermodilution Systems
33
Percutaneous Sheath Introducer Sets
CriticathTM Pulmonary Artery Catheters
CritikitTM Systems and Accessories
33
34
35
Argon Pressure Transducer Sets
36
DTX Plus Pressure Transducers
GabarithTM Tested Transducer Sets
SafedrawTM Sets
Safedraw-PTM Sets
Paediatric and Neonatal Sets
Flexi Sets
RT2000 Sets
Cardiac Catheterisation Laboratory Transducer Sets
Pressure Lines and Accessories
Interface Cables
TM
Appendix
Cannula/Catheter Conversion
Symbol Guidance
Index
36
38
39
40
42
43
44
46
48
49
54
54
55
56
Interventional Cardiology and Radiology Products
Speciality Products
Argon OptionTM Inferior Vena Cava Filter
Sterile, single use
Argon OptionTM Inferior Vena Cava Filter
Introducer Sheath
Length (cm)
Description
Working Caval Diameter
Box/Case
Content (Units)
Product
Code
6.5Fr OD (5Fr ID)
70cm
OptionTM Vena Cava Filter System
Up to 32mm
Each
352506070
The Argon OptionTM IVC Filter is used for the prevention of recurrent pulmonary embolism.
Designed for both permanent and retrievable IVC Filter placement, the Argon OptionTM IVC Filter offers the safety and
stability required for permanent placement coupled with proven long term retrievability.
Suitable for caval diameters up to 32mm, with no minimal caval restrictions, and deployed via a 6.5Fr OD (5Fr ID) x 70cm
low-profile delivery sheath with infusion port, Option’s precise placement is aided by the use of an innovative over-thewire curved pusher system.
The spiral coiled sheath provides increased column strength and kink-resistance for ease of tracking, pushability, and
delivery.
Dilator, with 32mm spaced radiopaque markers for rapid vena cava measurement and helix formation end-holes compatible
with power injectors up to 800 psi.
Single, colour coded filter cartridge for Femoral or Jugular placement.
Durable, one piece design of filter reduces the risk of fracture caused by bending stress2.
Resilient, electropolished, nitinol hypotube filter construction improves resistance to fracture caused by cyclic stress1.
The transitionless and sturdy design of the hook allows for ease of snaring and reduced risk of hook deformation during
retrieval.
The stable filter base conforms to the caval anatomy, reducing caval penetration3 and aids in centering the filter whilst
innovative retention anchors are designed to prevent caudal and cephalid migration.
These curved, non-flexible anchors reduce caval wall penetration and provide the balance between stability and retrievability.
Description
Argon OptionTM IVC Filter contents:
Argon colour coded OptionTM filter cartridge system for Femoral or Jugular placement, Argon 6.5Fr OD x 70cm low profile delivery sheath with side arm,
Argon dilator with 32mm spaced R/O markers, Argon curved pusher and sheath cap.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 3 years
Sterilisation method: Ethylene Oxide
1. Hodgson, Darel E., Ming H. Wu, and Robert J. Biermann. “Shape Memory Alloys” Online. Available SMA INC.
2. Medical Device Network March 2006 “Nitinol: The Shape of Things to Come.”
3. The Safety and Effectiveness of the Retrievable OptionTM Vena Cava Filter: A United States Prospective Multicenter Clinical Study. Matthew S. Johnson, MD, James
F. Benenati, MD, John A. Kaufman, MD, et al. J Vasc Interv Radiol 2010; 21:1173-1184
Interventional Cardiology and Radiology Products
Speciality Products
Argon Cleaner* and Cleaner15TM Rotational
Thrombectomy Systems
Sterile, single use
Argon Cleaner* and Cleaner15TM Rotational Thrombectomy Systems
Cleaner Sheath
Length (cm)
Cleaner Shaft OD
Description
Sinusoidal Wire
Amplitude (mm)
Box/Case
Content (Units)
Product
Code
65cm
6Fr
Cleaner* Rotational Thrombectomy System
9mm
Each
700009
135cm
6Fr
Cleaner Rotational Thrombectomy System
9mm
Each
700109
65cm
7Fr
Cleaner15TM Rotational Thrombectomy System
15mm
Each
700015
135cm
7Fr
Cleaner15TM Rotational Thrombectomy System
15mm
Each
700115
*
The Argon Cleaner* and Cleaner15TM Rotational Thrombectomy Systems are indicated for mechanical declotting of native
vessel dialysis fistulae and synthetic dialysis access grafts.
Ergonomic, procedure-ready, one piece design device with no assembly required.
Completely disposable – no capital equipment required.
Intuitive to operate, with quiet operation, facilitating patient comfort during procedure.
Guidewire-like design with safety locking mechanism provides excellent steerability, whilst atraumatic tip provides patient
safety in both AV fistulae and grafts.
Innovative radiopaque S-wire design with choice of 9mm or 15mm sinusoidal wire amplitudes, designed to conform to
varying lumen diameters whilst actively cleaning wall-adherent clot.
Cleaner15TM with larger wire diameter for increased pushability, increased torque and performance for efficient thrombus
maceration and 15mm sinusoidal wire amplitude for enhanced removal of wall-adherent thrombus.
Drive unit rotates the sinusoidal wire at up to 4,500 rpm creating a fluid vortex and gently macerating thrombus whilst
reducing the risk of endothelial damage¹.
The Cleaner*/Cleaner15TM single sinusoidal wire is capable of cleaning around the opposing sheath, thereby reducing
procedure time and sheath manipulation.
3-way sideport and distal sidehole on catheter (135 cm) allows for infusion of fluids and contrast media.
Description
Argon Cleaner* Rotational Thrombectomy System contents:
One-piece, 6Fr Cleaner* Thrombectomy System with 0.035” Sinusoidal wire and 6Fr OD sheath.
For use with 6Fr sheath systems.
Argon Cleaner15TM Rotational Thrombectomy System contents:
One-piece, 7Fr Cleaner15TM Thrombectomy System with 0.044” Sinusoidal wire and 7Fr OD sheath.
For use with 7Fr sheath systems.
Cleaner15TM is contraindicated for vessels less than 6mm in diameter.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 3 years
Sterilisation method: Ethylene Oxide
1. F. Vega, Safety Comparison of Cleaner* Rotational Thrombectomy System Versus Arrow PTD in Native Vessel
* CLEANER and CLEANER15 are trademarks of Rex Medical.
Interventional Cardiology and Radiology Products
Speciality Products
Argon UltraStreamTM Chronic Dialysis Catheters
Sterile, single use
Argon UltraStreamTM Chronic Dialysis Catheters
UltraStream Catheter
Length (cm)
UltraStream OD (Fr)
Description
Box/Case
Content (Units)
Product
Code
ARGON ULTRASTREAMTM CATHETER STANDARD SHEATH KIT
24cm
15.5Fr
UltraStreamTM Standard Kit
5
32101524
28cm
15.5Fr
UltraStreamTM Standard Kit
5
32101528
32cm
15.5Fr
UltraStream Standard Kit
5
32101532
36cm
15.5Fr
UltraStream Standard Kit
5
32101536
40cm
15.5Fr
UltraStreamTM Standard Kit
5
32101540
TM
TM
ARGON ULTRASTREAM CATHETER PEEL-AWAY KIT
TM
24cm
15.5Fr
UltraStreamTM Peel-Away Sheath Kit
5
32401524
28cm
15.5Fr
UltraStream Peel-Away Sheath Kit
5
32401528
32cm
15.5Fr
UltraStreamTM Peel-Away Sheath Kit
5
32401532
36cm
15.5Fr
UltraStream Peel-Away Sheath Kit
5
32401536
40cm
15.5Fr
UltraStreamTM Peel-Away Sheath Kit
5
32401540
TM
TM
ARGON ULTRASTREAM CATHETER EXCHANGE KIT
TM
24cm
15.5Fr
UltraStreamTM Exchange Kit
1 box of 5
32001524
28cm
15.5Fr
UltraStream Exchange Kit
1 box of 5
32001528
32cm
15.5Fr
UltraStream Exchange Kit
1 box of 5
32001532
36cm
15.5Fr
UltraStreamTM Exchange Kit
1 box of 5
32001536
40cm
15.5Fr
UltraStream Exchange Kit
1 box of 5
32001540
TM
TM
TM
Argon UltraStreamTM Chronic Dialysis Catheters are indicated for Haemodialysis and Apheresis.
Argon UltraStreamTM patented, dual independent arterial lumen design provide high flow rates of 500ml/min and allow for
continued functional dialysis should infusion be restricted to one arterial lumen. Dual arterial lumens also reduce the risk
of catheter ‘side walling’. The unique, transitionless, modified-tip design facilitates atraumatic over-the-wire insertion for
‘first-time’ or ‘Exchange’ insertions, without requirement for a peel-away sheath. Shortened length between distal lumens
allows for more accurate tip placement whilst achieving zero recirculation rates during normal flow1. Kink resistant Carbothane®
catheter material provides strength for catheter longevity and softness for patient comfort. The Carbothane® thermo-sensitive
biocompatible material is radiopaque for increased visibility whilst being resistant to iodine and alcohol degradation. Durable
luer catheter connectors with easy-to-read printed priming volumes are ergonomically designed to withstand multiple
connections and compatible with a broad spectrum of cleansing agents, thereby reducing the risk of cracking. 1 Data on file
Description
Argon UltraStreamTM Chronic Dialysis Catheter Standard Kit contents:
Argon UltraStreamTM 15.5Fr Catheter, Flexible Stiffener, 16Fr Vessel
Dilator, #11 Safety Scalpel, 18G x 2.75’’ Introducer Needle, Tunneling
Device, 2 x Needleless Injection Site Caps, 2 x Adhesive Bandage,
Safety Foam. (Recommended guidewire size: 0.035’’ or 0.038’’ x 120cm
minimum length.)
Argon UltraStreamTM Chronic Dialysis Catheter Peel-Away Kit contents:
Argon UltraStreamTM 15.5Fr Catheter, 16Fr Peel-Away Sheath, Flexible
Stiffener, 16Fr Vessel Dilator, 0.038’’ x 80cm Guidewire, #11 Safety
Scalpel, 18G x 2.75’’ Introducer Needle,Tunneling Device, 2 x Needleless Injection Site Caps, 2 x Adhesive Bandage, Safety Foam.
Argon UltraStreamTM Chronic Dialysis Catheter Exchange Kit contents:
Argon UltraStreamTM 15.5Fr Catheter, Flexible Stiffener, 2 x Needleless
Injection Site Caps.
Latex free & CE marked
Class lll according to the European Medical Devices
Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 2 years
Sterilisation method: Ethylene Oxide
Carbothane® is a registered trademark of the Lubrizol Corporation
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon JawzTM Endomyocardial Biopsy Forceps
Sterile, single use
Argon JawzTM Endomyocardial Biopsy Forceps
Jaw OD
(mm)
Jaw OD
(Fr)
Jaw Volume
(mm3)
Forcep
Length (cm)
Recommended
Sheath Size (Fr)
FEP
Coating
Tip Configuration
Shaft Type
Box/Case
Contents (Units)
Product Code
2.4
7.5Fr
5.43
50
8Fr
No
Straight
Formable
Each
190020
2.4
7.5Fr
5.43
50
8Fr
Yes
Pre-Curve
Formable
Each
190030
2.4
7.5Fr
5.43
50
8Fr
Yes
Maxi-Curve
Formable
Each
190031
2.4
7.5Fr
5.43
105
8Fr
No
Straight
Formable
Each
190040
2.2
7Fr
4.97
50
7Fr
Yes
Pre-Curve
Formable
Each
190080
2.2
7Fr
4.97
50
7Fr
Yes
Maxi-Curve
Formable
Each
190081
2.2
7Fr
4.97
105
7Fr
No
Straight
Formable
Each
190085
2.2
7Fr
4.97
105
7Fr
Yes
Straight
Formable
Each
190086
1.8
5.5Fr
2.46
50
6Fr
Yes
Maxi-Curve
Formable
Each
190051
1.8
5.5Fr
2.46
50
6Fr
No
Straight
Formable
Each
190060
1.8
5.5Fr
2.46
50
6Fr
No
Straight
Non-Formable
Each
190065
1.8
5.5Fr
2.46
70
6Fr
Yes
Straight
Formable
Each
190066
1.8
5.5Fr
2.46
105
6Fr
No
Straight
Formable
Each
190070
1.8
5.5Fr
2.46
105
6Fr
No
Straight
Non-Formable
Each
190075
1.5
5Fr
1.8
50
5Fr
No
Straight
Formable
Each
190090
1.5
5Fr
1.8
105
5Fr
No
Straight
Formable
Each
190095
Developed by transplant cardiologists for use by transplant cardiologists, Argon JawzTM Endomyocardial Biopsy Forceps
for the collection of biopsy tissue samples of the myocardium.
The unique cutting edge design of JawzTM Forceps facilitates superior surface alignment to provide a clean cut and improved
quality of biopsy sample.
The cutting jaws are precision machined from a proprietary alloy to remain sharp throughout the biopsy procedure.
The precision-molded three-ringed handle provides a solid “instrument” feel and adapts to maintain the users desired thumb
position. With formable and non-formable configurations to best suit your desired technique, JawzTM Forceps stainless steel
shafts are available with or without FEP Coating to support smooth shaft passage.
JawzTM Forceps shaft option of Straight, Pre-Curved and Maxi-Curved configurations to provide the best patient access.
Description
Argon JawzTM Endomyocardial Biopsy Forcep Kit contents:
Argon JawzTM Endomyocardial Biopsy Forcep and Instructions for Use.
Latex free
CE marked
Class llI according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (maximum)
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon AXcessTM Introducer System for
Cardiology and Radiology Applications
Sterile, single use
Argon AXcessTM Introducer Sheath System
Introducer
Length (cm)
Introducer Size (Fr)
Description
Guidewire
Box/Case
Content (Units)
Product
Code
5.75cm
4Fr
AXcessTM Introducer Sheath
0.021'' x 400mm Straight
10
496064
5.75cm
5Fr
AXcess Introducer Sheath
0.025'' x 400mm Straight
10
496065
5.75cm
6Fr
AXcessTM Introducer Sheath
0.032'' x 400mm Straight
10
496066
5.75cm
7Fr
AXcess Introducer Sheath
0.032'' x 400mm Straight
10
496067
11cm
4Fr
AXcess Introducer Sheath
0.035'' x 450mm 'J'/Straight
10
496004
11cm
5Fr
AXcessTM Introducer Sheath
0.038'' x 450mm 'J'/Straight
10
496005
11cm
6Fr
AXcess Introducer Sheath
0.038'' x 450mm 'J'/Straight
10
496006
11cm
7Fr
AXcessTM Introducer Sheath
0.038'' x 450mm 'J'/Straight
10
496007
11cm
8Fr
AXcess Introducer Sheath
0.038'' x 450mm 'J'/Straight
10
496008
11cm
9Fr
AXcessTM Introducer Sheath
0.038'' x 450mm 'J'/Straight
10
496009
TM
TM
TM
TM
TM
11cm
5Fr
AXcess Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
496035
11cm
6Fr
AXcessTM Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
496036
11cm
7Fr
AXcess Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
496037
11cm
8Fr
AXcessTM Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
496038
23cm
5Fr
AXcess Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
490005
23cm
6Fr
AXcess Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
490006
23cm
7Fr
AXcessTM Introducer Sheath without Guidewire
Accepts 0.035'' - 0.038'' Wire
10
490027
TM
TM
TM
TM
Argon AXcessTM Catheter Lab Introducers with integrated sidearm are designed for arterial applications and left heart
procedures.
Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing, the thermally tapered sheath
design of the Argon AXcessTM introducer provides smooth insertion and minimises catheter peelback.
The AXcessTM introducer polyurethane obturator minimises damage to vessel intimal lining whilst the Flex Collar, with
Suture Tab, reduces kinking risk and provides a convenient suture site.
The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator
assembly prevents dilator push-back during insertion.
The 3-Part hemostasis Valve of the Argon AXcessTM introducer prevents bleedback by effectively sealing around the
inserted wire and catheter.
Description
Argon AXcessTM Introducer Sheath Kit contents:
Argon AXcessTM Introducer Sheath and matched dilator. Guidewire configuration as shown in table.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon 1SticTM Micro-Introducer Systems for
Cardiology and Radiology Applications
Sterile, single use
Argon 1SticTM Micro-Introducer Sheath System
Introducer
Length (cm)
Introducer
Size (Fr)
Description
Needle Gauge/Length
Guidewire (Core/Tip)
Box/Case
Content (Units)
Product
Code
5.75cm
6Fr
1SticTM Introducer Sheath
21G x 5.1cm
0.018'' x 45cm (Stainless Steel)
10
497850
5.75cm
6Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497854
5.75cm
7Fr
1SticTM Introducer Sheath
21G x 5.1cm
0.018'' x 45cm (Stainless Steel)
10
497863
5.75cm
8Fr
1Stic Introducer Sheath
21G x 5.1cm
0.018'' x 45cm (Stainless Steel)
10
497852
11cm
4Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497820
11cm
5Fr
1SticTM Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497830
11cm
6Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497840
11cm
7Fr
1SticTM Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497861
TM
TM
TM
TM
11cm
8Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497862
5.75cm
5Fr
1SticTM Introducer Sheath
21G x 2.5cm
0.018'' x 45cm (Nitinol/Platinum)
10
497865
5.75cm
6Fr
1Stic Introducer Sheath
21G x 5.1cm
0.018'' x 45cm (Nitinol/Platinum)
10
497853
5.75cm
7Fr
1SticTM Introducer Sheath
21G x 2.5cm
0.018'' x 45cm (Nitinol/Platinum)
10
497867
11cm
4Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Nitinol/Platinum)
10
497821
11cm
5Fr
1SticTM Introducer Sheath
21G x 7cm
0.018'' x 45cm (Nitinol/Platinum)
10
497831
11cm
6Fr
1Stic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Nitinol/Platinum)
10
497841
5.75cm
7Fr
1Stic Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497860
11cm
4Fr
1SticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497857
11cm
5Fr
1Stic Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497859
11cm
6Fr
1SticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497855
TM
TM
TM
TM
TM
TM
Argon1SticTM Micro-Introducers with integrated sidearm are designed to support smaller puncture site access for both arterial and
venous procedures allowing the physician to insert an introducer utilising micro-puncture technology.
Shorter sheath (5.75cm) versions designed for venous procedures in the neck or arm, the smooth transition between introducer sheath
and dilator provides atraumatic, low-profile insertion, minimising the risk of vessel trauma and catheter peelback. The 1SticTM micro tapered dilator transitions from 0.5Fr (for 0.018’’ micro-access guidewire) to maximum French size whilst the Flex Collar, with Suture Tab,
reduces kinking risk and provides a convenient suture site.
The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator assembly
prevents dilator push-back during insertion. The 3-Part hemostasis Valve of the Argon 1SticTM catheter prevents bleed-back by effectively
sealing around the inserted wire and catheter.
Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing, these introducer sets are available with a
choice of Stainless Steel or Nitinol/Platinum guidewires, along with Echogenic introducer needle option, for increased visibility under
Fluoroscopy and Ultrasound, whilst the 4Fr-8Fr introducer sizes allow for multiple device exchanges during procedure.
Description
Argon 1SticTM Micro-Introducer Sheath Kit contents:
Argon 1SticTM Micro-Introducer Sheath, micro-tipped dilator, guidewire and introducer needle.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon MicroSticTM Introducer Systems for
Cardiology and Radiology Applications
Sterile, single use
Argon MicroSticTM Micro-Introducer Sheath System
Introducer
Length (cm)
Introducer
Size (Fr)
Description
Needle Gauge/Length
Guidewire (Core/Tip)
Box/Case
Content (Units)
Product
Code
10cm
4Fr
MicroSticTM Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497801
10cm
5Fr
MicroStic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Stainless Steel)
10
497802
10cm
4Fr
MicroSticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Stainless Steel)
10
497816
10cm
5Fr
MicroSticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Stainless Steel)
10
497817
10cm
4Fr
MicroStic Introducer Sheath
21G x 7cm
0.018'' x 45cm (Nitinol/Platinum)
10
497811
10cm
5Fr
MicroSticTM Introducer Sheath
21G x 7cm
0.018'' x 45cm (Nitinol/Platinum)
10
497812
10cm
4Fr
MicroSticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497813
10cm
5Fr
MicroSticTM Introducer Sheath
21G x 7cm Echogenic
0.018'' x 45cm (Nitinol/Platinum)
10
497814
TM
TM
Argon MicroSticTM Micro–Introducer, double dilator systems are designed to support smaller puncture site access for
arterial applications and left heart procedures.
Argon MicroSticTM Micro-Introducer systems eliminate the need to dilate up using multiple dilators and result in a tight
seal around catheter by the vessel. A seamless transition between introducer sheath and dilator enablies a smooth, lowprofile insertion, thereby minimising the risk of vessel trauma and catheter peelback.
Introducer sets are available with a choice of Stainless Steel, Nitinol/Platinum or Nitinol/Stainless guidewires, along with
Echogenic introducer needle option, for increased visibility under Fluoroscopy and Ultrasound. The positive twist-lock dilator assembly prevents dilator push-back during insertion.
4Fr introducer: inner and outer dilators made from radiopaque Pebax (Polyether Block Amide) sheath material.
5Fr introducer: inner dilator made from radiopaque Pebax (Polyether Block Amide) and outer dilator made from HDPE
(High Density Polyethylene) sheath materials.
Description
Argon MicroSticTM Micro-Introducer Sheath Kit contents:
Argon MicroSticTM Introducer Sheath and matched dilator, 21G Introducer Needle and 0.018’’ x 45cm Guidewire (as shown).
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Arterial Access Needles
Sterile, single use
Argon Range of Arterial Access Needles to provide vascular access for the percutaneous introduction of a
guidewire
Full Needle range available offering one-piece, two-piece & three-piece units to meet Customer Needs.
Single wall thin-walled ‘flashback’ needles, available as one-piece needle with removable hub (AMC/3), with finger grip
hub (AMC/4), or with winged hub (AMC/4 with wings) (AMC = Argon Medical Corporation).
Ultra-thin wall style needles, including:
Percutaneous Entry – two-piece needle with tapered outer cannula and bevelled solid stylet.
AMC/4 – one-piece needle with finger grip hub
AMC/4 with wings – one-piece needle with a winged hub
Increased needle strength due to cannula being ‘flared’ into needle hub.
Argon Arterial Access Needles are siliconised for easier introduction into vasculature.
Tapered, insert-moulded, crack- and chemical-resistant needle hubs facilitating guidewire introduction.
Clear hubs facilitating rapid flashback visualisation.
Double wall style needles, including:
Percutaneous Entry – two-piece needle with tapered outer cannula and bevelled solid stylet.
Vented Percutaneous Entry - two-piece needle with tapered outer cannula and bevelled hollow stylet.
Cournand – three-piece needle with angled outer cannula, hollow and bevelled inner stylet protruding out of hub and a
blunt obturator.
Modified Cournand – two-piece needle with angled outer cannula and hollow and bevelled inner stylet.
Match-tapered ID & OD cannula tips (‘Swaging’) decreases ‘coring’ incidence and facilitates penetration.
100% inspection of inner & outer needle fit, eliminating ‘spaces’ resulting in smoother needle insertion.
Insert-moulded chemically resistant polypropylene hub with enhanced ‘feel’.
Non-radiopaque hub and gripping shield eliminates x-ray shadow.
See product table on next page.
Description
Argon Range of Arterial Access Needles Set Contents:
Single packed Arterial Needle and protective sheath.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Arterial Access Needles
Sterile, single use
Argon Arterial Needles
Gauge
Length (cm)
For Guidewire Sizes
Special Features
Box Contents
(Units)
Product
Code
AMC/3 - ARTERIAL NEEDLE WITH REMOVABLE NEEDLE ADAPTER
18G
7cm
0.032” - 0.038”
10
195312
19G
3.8cm
0.025” - 0.028''
10
195315
21G
2.5cm
0.018” - 0.021''
10
195311
0.035” - 0.038”
10
195317
AMC/4 - CLEAR FLASHBACK NEEDLE
18G
3.8cm
18G
7cm
0.035” - 0.038”
10
195318
19G
3.8cm
0.025” - 0.028”
10
195319
21G
2.5cm
0.018” - 0.021”
10
195322
21G
5.1cm
0.018” - 0.021”
10
195323
21G
7cm
0.018” - 0.021”
10
195310
10
195352
Extra Thin Wall
AMC/4 - WINGED ARTERIAL NEEDLE
18G
7cm
0.035” - 0.038”
PERCUTANEOUS ENTRY NEEDLE
18G
7.3cm
0.032” - 0.038”
Two Part: Thin Wall Tapered Cannula and Inner Arterial Beveled Stylet
10
195326
18G
7.3cm
0.032” - 0.038”
Two Part: Thin Wall Tapered Cannula and Vented Arterial Beveled Stylet Needle
10
195351
5.4cm
0.032” - 0.038”
Three Part: Outer Thin Wall Tapered Cannula, Inner Arterial Beveled and Round
Ended Obturator
10
195336
0.032” - 0.038”
Two Part: Outer Thin Wall Tapered Cannula and Inner Arterial Beveled Needle
10
195350
COURNAND STYLE NEEDLE
18G
MODIFIED COURNAND STYLE NEEDLE
18G
5.4cm
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Standard and
Speciality Guidewires
Sterile, single use
Argon Range of Standard and Speciality Guidewires for use in the Critical Care, Cardiac Catheterisation Laboratory
and Radiology Special Procedures environment
Full range of guidewires offering Fixed Core/Straight, Fixed Core/’J’, double ended and Fixed/Moveable Core Speciality
wires to meet most customer needs.
Choice of Stainless Steel (SS) and NiTiNol guidewires, with PTFE or Heparin/PTFE coating; lengths from 40cm to 260cm
and diameters from 0.018’’ to 0.038’’.
PTFE coating provides ultra-smooth surface to prevent catheter drag.
Argon coil welding process ensures uniform diameter from tip to end.
Enhanced flexible tip facilitates easy tip manipulation.
Fixed and Moveable core options allowing for additional manipulation opportunity at the flexible wire tip.
Five styles of guidewire available, offering the Customer superior choice based on personal technique:
Standard: with traditional feel and performance
Flexible: with softer tip for increased manoeuvrability
Classic: with stiffer body for increased push ability.
Zebra Tip (Z-Tip): with stiffer body for increased push ability.
XTB: with stiffer body and a short taper for increased push ability
Tip Styles:
Straight
‘J’ Tip - determined by the mm radius of the ‘J’.
Double-Ended - normally Straight & 3mm ‘J’
Newton - can be Long Taper (LT) 10cm, Long Long Taper (LLT) 15cm or Long Long Long Taper (LLLT) 20cm.
Bentson - has no taper core for last 15cm
Mandrel–type - provides the maximum amount of body stiffness per the cross sectional area.
See product table on next page.
Description
Argon Range of Standard and Speciality Guidewires Set Contents:
Single packed coiled guidewire and protective sheath with straightener.
Latex free
CE marked
Class IIa and lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Standard and
Speciality Guidewires
Sterile, single use
Argon Guidewires - Fixed Core Straight
Length (cm)
Description
Core Taper (cm)
Tip Curve Radius
Box Contents
(Units)
Product
Code
.018“
40cm
Stainless Steel
9.0
Straight
10
395451
.018“
80cm
Stainless Steel
9.0
Straight
10
395200
.018“
100cm
Stainless Steel
9.0
Straight
10
395201
.021”
25cm
Stainless Steel
9.0
Straight
10
395536
.021”
40cm
Stainless Steel
9.0
Straight
10
395513
.021”
80cm
Stainless Steel
9.0
Straight
10
395203
.021”
125cm
Stainless Steel
9.0
Straight
10
395205
.021”
150cm
Stainless Steel
9.0
Straight
10
395509
.025”
40cm
Stainless Steel
9.0
Straight
10
395206
.035”
75cm
Stainless Steel
8.5
Straight
10
395711
Diameter (inch)
STAINLESS STEEL
PTFE COATED STAINLESS STEEL
.025”
150cm
PTFE Coated Stainless Steel
9.0
Straight
10
395225
.035”
150cm
PTFE Coated Stainless Steel (Heavy Duty)
3.5
Straight
10
395687
.038”
150cm
PTFE Coated Stainless Steel
8.5
Straight
10
395234
9.0
Straight
10
395367
EXCHANGE WIRES - PTFE COATED
.025”
260cm
Exchange Wires - PTFE Coated
.035”
260cm
Exchange Wires - PTFE Coated
8.5
Straight
10
395369
.038”
260cm
Exchange Wires - PTFE Coated
8.5/3
Straight
10
395370
MANDREL WIRES FOR MICRO-PUNCTURE TECHNIQUE
.018”
45cm
Stainless Steel
9.5
Straight
10
395125
.018”
45cm
NiTiNol (4.8cm Platinum Coil Tip)
N/A
Straight
10
395126
MULLINS TIP DEFLECTOR WIRES - STAINLESS STEEL
.018”
100cm
Stainless Steel
1.5/2
Straight
10
395945
.021”
100cm
Stainless Steel
1.5
Straight
10
395948
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Standard and
Speciality Guidewires
Sterile, single use
Argon Guidewires - Fixed Core ‘J’ Tip
Diameter (inch)
Length (cm)
Description
Core Taper (cm)
Tip Curve Radius
Box Contents
(Units)
Product
Code
PTFE COATED - STAINLESS STEEL
.025”
150cm
9.0
1.5mm
10
395420
.035”
150cm
8.5
1.5mm
10
395787
.021”
150cm
9.0
3mm
10
395523
.025”
150cm
9.0
3mm
10
395559
.032”
150cm
8.5
3mm
10
395600
.035”
150cm
8.5
3mm
10
395282
.035”
150cm
9.5
3mm
10
388282
.035”
150cm
Z-Tip
8.5
3mm
10
393282
.035”
150cm
Z-Tip (Heavy Duty)
8.5
3mm
10
393182
.035”
150cm
XTB
6.5
3mm
10
390282
.035”
175cm
Z-Tip (Heavy Duty)
8.5
3mm
10
393186
.035”
175cm
XTB/Z-Tip
6.5
3mm
10
390186
.038”
150cm
8.5
3mm
10
395284
.038”
150cm
9.5
3mm
10
388284
.038”
150cm
Z-Tip
8.5
3mm
10
393184
.038”
150cm
XTB
6.5
3mm
10
390284
.038”
175cm
Z-Tip
8.5
3mm
10
393187
PTFE COATED STAINLESS STEEL DOUBLE ENDED
.035”
50cm
Straight & 3mm
8.5/8.5
3mm
10
395998
.035”
150cm
Straight & 1.5mm
8.5/8.9
1.5mm
10
395919
EXCHANGE WIRES - PTFE COATED
.025”
260cm
9.0
3mm
10
395585
.035”
200cm
8.5
3mm
10
395722
.035”
260cm
8.5
3mm
10
395794
Interventional Cardiology and Radiology Products
Vascular Access Products
Argon Range of Standard and
Speciality Guidewires
Sterile, single use
Argon Guidewires - Speciality
Diameter (inch)
Length (cm)
Description
Core Taper (cm)
Tip Curve Radius
Box Contents
(Units)
Product
Code
FIXED CORE - STAINLESS STEEL
.021”
40cm
9.0
3mm
10
395510
.025”
40cm
9.0
3mm
10
395573
.035”
40cm
8.5
3mm
10
395271
.035”
50cm
8.5
3mm
10
395654
.035”
75cm
8.5
3mm
10
395752
FIXED CORE - STAINLESS STEEL DOUBLE ENDED
.025”
65cm
Straight & 3mm
9.0
3mm
10
395415
.032”
65cm
Straight & 3mm
8.5
3mm
10
395539
.035”
45cm
Straight & 3mm
8.5
3mm
10
395680
.035”
65cm
Straight & 3mm
8.5/8.9
3mm
10
395899
.035”
80cm
Straight & 3mm
8.5/8.5
3mm
10
395868
395930E
FIXED CORE - BENTSON CEREBRAL WIRES - PTFE COATED
.035”
150cm
16.0
10
.035”
180cm
16.0
10
395170
.038”
150cm
10
395933C
MOVEABLE CORE PTFE COATED
.035”
150cm
.032”
150cm
.035”
145cm
.035”
150cm
.035”
150cm
.035”
150cm
.038”
150cm
Straight
Tapered
Standard
10
395258
Standard
3mm
10
395309
9.0
3mm
10
395721
Standard
3mm
10
395320
Tapered
5.5
3mm
10
388300
Heavy Duty
Standard
3mm
10
395312
Standard
3mm
10
395315
Fluid Management Systems
Argon Range of Manifolds and
High Pressure Injection Lines
Sterile, single use
Argon Range of Manifolds & High Pressure Injection Lines for Optimal Fluid Control during Left Heart Studies,
Coronary Injections, Arteriograms/Venograms and other Radiological Procedures
With choice of ‘Open’ or ‘Finger grip’ (Block) design, with 2, 3 or 4 valve ports, all Argon Manifolds have ‘Left’ or ‘Right’
rotating adapter to best meet specific procedural needs and physician preferences.
Manifold valves with tight tolerances, low torque and smooth port rotation.
Choice of ‘Open’ or ‘Block’ body design and clear polycarbonate body for easy bubble visualisation, the manifolds
construction will withstand injections and are rated at 500 psi.
Threaded ISO standard luer fittings with funnelled tapered ports to minimise bubble entrapment.
Celcon taps for smooth rotation movement, with positive handle stops and labelled handles for easy identification.
Manifold Distal Rotating Adapter facilitates easy catheter manipulation.
Argon High Pressure Injection Lines are available in clear, semi-rigid PVC and Flexible Braided Polyurethane with or
without Rotating Adapter.
Argon High Pressure Injection Lines are designed to provide optimal flexibility, easy debubbling and secure connections
and are rated up to 1200 psi.
See product table on next page.
Description
Argon Range of Manifolds & High Pressure Injection Lines Set Contents:
Single packed, sterile product.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Fluid Management Systems
Argon Range of Manifolds and High Pressure
Injection Lines
Sterile, single use
Argon 500 psi Manifolds
No. of Ports
Open/Block Body
Handles (On/Off)
Box Contents (Units)
Product Code
RIGHT ORIENTATION 500 PSI MANIFOLDS WITH ROTATING ADAPTER
2 Port
Open
On
25
193101
2 Port
Open
Off
25
193103
2 Port
Block
On
25
193109
2 Port
Block
Off
25
193111
3 Port
Open
On
25
193117
3 Port
Open
Off
25
193119
3 Port
Block
On
25
193125
3 Port
Block
Off
25
193127
4 Port
Open
On
25
193133
4 Port
Open
Off
25
193135
4 Port
Block
On
25
193149
Off
25
193107
LEFT ORIENTATION 500 PSI MANIFOLDS WITH ROTATING ADAPTER
2 Port
Open
3 Port
Open
Off
25
193123
3 Port
Block
Off
25
193131
RIGHT ORIENTATION 500 PSI MANIFOLDS WITH 15CM TUBING EXTENSION
2 Port
Block
On
25
193145
2 Port
Block
Off
25
193146
3 Port
Block
On
25
193141
Argon 1200 psi High Pressure Injection Lines
Description
25cm
50cm
76cm
122cm
152cm
183cm
244cm
Box Contents
(Units)
FLEXIBLE BRAIDED HIGH PRESSURE INJECTION LINES
Male to Female
193358
193359
193360
193361
193376
193377
193381
25
Rotating Adapter
193362
193363
193364
193365
193375
193378
193382
25
CLEAR PVC HIGH PRESSURE INJECTION LINES
Male to Female
193350
193351
193352
193353
Rotating Adapter
193354
193355
193356
193357
193368
193366
25
193373
25
Fluid Management Systems
Argon Range of Control Syringes
Sterile, single use
Argon Range of Control Syringes for Optimal Fluid Control during Left Heart Studies, Coronary Injections,
Arteriograms/Venograms and other Radiological Procedures
Argon Control Syringes
Description
10ml
12ml
10ml Soft Touch
12ml Soft Touch
Rotating Adapter
193206
193210
193249
Fixed Male Luer
193205
193209
193248
10ml Dosage Control
12ml Dosage Control
Box Contents
(Units)
193222
25
193221
25
THUMB RING/FINGER RINGS
193217
THUMB RING/FINGER GRIPS
Rotating Adapter
193214
25
Fixed Male Luer
25
PALM PAD/FINGER RINGS
Rotating Adapter
Fixed Male Luer
193207
193212
25
193211
25
PALM PAD/FINGER GRIPS
Rotating Adapter
Fixed Male Luer
193203
193239
25
193238
25
With choice of ‘Thumb Ring’ or ‘Palm Pad’ design, ‘Finger Ring’ vs ‘Finger Grip’, and 10cc vs 12cc volume options, there
is an Argon Control Syringe available to best suit most Clinical Needs and hand sizes.
The low friction plunger provides for a smooth injection whilst bold volume markings facilitate accurate volume injections.
Clear polycarbonate body provides a sturdy syringe able to withstand any hand pressure whilst facilitating for easy bubble
visualisation.
Fixes luer designed for correct orientation of syringe to manifold with rotating adapter options offering flexibility during
manipulation.
Thumb ring design facilitates aspirations and injections whilst choice of finger grip or ring style to meet most clinical needs.
Choice of Palm Pad designs, including ‘soft touch’ options, allows for full force palm injections.
10cc or 12cc volume options for larger handed use, Argon ‘Standard’ Control Syringes have a reservoir area reducing risk
of accidental air injection.
Argon Dosage Control syringes help in preventing the over-injection of contrast media during angiography studies and
facilitate in contrast media conservation.
Description
Argon Range of Control Syringes Contents:
Single packed, sterile product.
Latex free
Shelf life: 5 years (maximum)
CE marked
Sterilisation method: Ethylene Oxide
Class lla according to the European Medical Devices
Directive 93/42/EEC as amended by Directive 2007/47/EC
Fluid Management Systems
Argon Range of Colour Coded
Medication Syringes
Sterile, single use
Argon Range of Colour Coded Medication Syringes
Medication Syringes 10ml
Description
Yellow
Red
White
Light Green
Dark Green
Purple
Box Contents
(Units)
382011
382021
382031
382041
382051
382061
25
Blue
UNPRINTED MEDICATION SYRINGES (10ML)
382001
Each package includes: clear adhesive labels, printed in black with common injectables. Labels: Lidocaine, Heparin/Saline, Heparin, Contrast, Nitroglycerine and ‘Blank’ (2 each).
PRE-PRINTED MEDICATION SYRINGES (10ML)
Contrast
382005
382015
382025
382035
Lidocaine
382003
382013
382023
382033
Saline
382006
382016
382055
382022
Heparin
382024
25
25
382046
Nitro
Flush
382045
25
382052
25
25
382037
25
Available in both unprinted and pre-printed versions, Argon Colour Coded Medication Syringes are latex free with clear 10cc
polycarbonate, APS colour coded plunger and silicone rubber stopper to facilitate in the safe administration of medication.
Description
Argon Range of Colour Coded Medication Syringes Contents:
Each Unprinted Medication Syringe package includes: clear adhesive labels, printed in black with common injectables.
Labels: Lidocaine, Heparin/Saline, Heparin, Contrast, Nitroglycerine and ‘Blank’ (2 each).
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (maximum)
Sterilisation method: Ethylene Oxide
Peripherally Inserted Central Catheters (PICC and Midline Catheters)
Argon Extended Dwell Catheter Products
Sterile, single use
The Argon family of PICC & Midline catheters and Introducer systems provides you with the best tools designed to make
the infusion therapy process simple, safe, and reliable.
Argon L-CathTM Polyurethane PICC and Midline Catheters
Argon L-CathTM Polyurethane PICC and Midline Catheters are intended to provide optimal outcomes for Long-Term and
Intermediate Therapies.
Argon L-CathTM PICC and Midline Catheters are designed for safe and easy placement.
Polyurethane catheter material provides catheter strength and increased flow rates.
Breadth of line offers access options for neonate to geriatric patient populations.
Pre-attached Y-site connector allows flushing of catheter before, during, and after the insertion.
Protective sleeve, designed to minimise accidental contamination of the catheter.
Catheter trim tool is designed to ensure clean and accurate 90° trimming.
Latex and DEHP free, Argon L-CathTM Polyurethane PICC and Midline Catheters are Pressure Rated with a Maximum
Pressure Tolerance of 40 psi.
Argon First PICCTM Silicone PICC and Midline Catheters
Argon First PICCTM and First MidcathTM high-quality silicone catheters designed for safe and easy placement.
Soft silicone integrated extension set intended to enhance patient comfort and provide increased mobility.
Breadth of line offers access options for neonate to geriatric patient populations.
Pre-attached T-port extension allows flushing of the catheter before and after insertion.
Hydrophilic stylet for smooth stylet removal.
Protective sleeve designed to minimise accidental contamination of the catheter.
Numbered catheter cm depth markings designed to allow easy measurement and catheter trimming prior to insertion.
Catheter trim tool is designed to ensure clean and accurate 90° trimming.
Latex and DEHP free, Argon First PICCTM and First MidcathTM high-quality silicone catheters are Pressure Rated with a
Maximum Pressure Tolerance of 40 psi.
Latex free
CE marked
Argon L-CathTM PICC and First PICCTM are Class lll according to the European Medical Devices Directive 93/42/EEC as
amended by Directive 2007/47/EC
Argon L-CathTM Midline and First MidcathTM are Class lla according to the European Medical Devices Directive 93/42/EEC
as amended by Directive 2007/47/EC
Shelf life: 3 years (maximum)
Sterilisation method: Ethylene Oxide
Peripherally Inserted Central Catheters (PICC and Midline Catheters)
Argon PICC and Midline Catheter
Introducer Systems
Sterile, single use
Argon Splittable Needle Introducer and Safety MST Sets
Gauge
Description
Box/Case
Content (Units)
Product
Code
1.2Fr (28G)
Splittable Needle Introducer
10
384061
5Fr (16G)
Safety MST Accessory Set
10
384824
4Fr (18G)
Safety MST Accessory Set
10
384823
3Fr (20G)
Safety MST Accessory Set
10
384822
Argon Splittable Needle Introducer and Safety MST Sets
Argon Splittable Needle Introducer for placement of 1.2Fr (28G) Catheters.
Argon Safety MST Accessory Sets for PICC and Midline Placement Using the Modified Seldinger Technique (MST).
For placement of 3Fr (20G), 4Fr (18G) and 5Fr (16G) PICC and Midline Catheters.
The InsyteTM AutoguardTM Shielded IV Catheter provides safe catheter introduction and reduced needlestick rish using the
BD AutoguardTM needle-shielding technology.
The Echogenic-tipped, protected needle provides safety needle-introduction when an ultrasound placement is preferred.
Clearly identified 5cm guidewire markings for easy determination of guidewire insertion length.
Lubricated, tapered-tip splittable sheath and dilator, designed to decrease insertion force and facilitate easier insertion
with less trauma to the patient.
Inner sterile package minimises accidental contamination risk of kit components.
Bard-ParkerTM safety-engineered protected disposable scalpel.
Description
Argon Splittable Needle Introducer contents:
Argon steel needle introducer with splittable technology.
Argon PICC and Midline Catheter Introducer Set Contents:
InsyteTM AutoguardTM shielded IV catheter; Echogenic-tipped, protected Safety needle Introducer; Soft-tipped guidewire; 5ml Syringe; Peel-away sheath
and matched dilator; safety-engineered protected disposable scalpel.
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 3 years
Sterilisation method: Ethylene Oxide
Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD IntrosyteTM and IntrosyteTM AutoguardTM Shielded Introducers are available via your local BD Agent.
These BD IntrosyteTM and IntrosyteTM AutoguardTM introducers incorporate the BD AutoguardTM needle-shielding technology.
Peripherally Inserted Central Catheters (PICC and Midline Catheters)
Argon L-CathTM Polyurethane PICC and
Midline Catheters
Sterile, single use
Argon L-CathTM Polyurethane PICC and Midline Catheters
Gauge
Length (cm)
Description
Box/Case
Content (Units)
Product
Code
ARGON L-CATHTM POLYURETHANE PICC SINGLE LUMEN CATHETER ONLY
5Fr (16G)
60cm
S/L L-CathTM PICC, Catheter Only
5
384465
3.5Fr (18G)
60cm
S/L L-CathTM PICC, Catheter Only
5
384464
3Fr (20G)
60cm
S/L L-Cath PICC, Catheter Only
5
384463
1.9Fr (26G)
30cm
S/L L-CathTM PICC, Catheter Only
5
384539
TM
ARGON L-CATHTM POLYURETHANE PICC DUAL LUMEN CATHETER ONLY
5Fr (16G)
60cm
D/L L-CathTM PICC, Catheter Only
5
384468
3.5Fr (18G)
60cm
D/L L-CathTM PICC, Catheter Only
5
384467
3Fr (20G)
60cm
D/L L-Cath PICC, Catheter Only
5
384466
TM
ARGON L-CATHTM POLYURETHANE MIDLINE SINGLE LUMEN CATHETER ONLY
3.5Fr (18G)
20cm
S/L L-CathTM Midline, Catheter Only
5
384621
3Fr (20G)
20cm
S/L L-CathTM Midline, Catheter Only
5
384620
ARGON L-CATH POLYURETHANE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTE AUTOGUARD SHIELDED INTRODUCER
TM
TM
TM
5Fr (16G)
60cm
S/L L-CathTM PICC Basic Kit with BD IntrosyteTM AutoguardTM
5
384499
3.5Fr (18G)
60cm
S/L L-Cath PICC Basic Kit with BD Introsyte Autoguard
TM
5
384490
3Fr (20G)
60cm
S/L L-CathTM PICC Basic Kit with BD IntrosyteTM AutoguardTM
5
384481
5
384516
TM
TM
ARGON L-CATH POLYURETHANE PICC SINGLE LUMEN BASIC KIT WITH ARGON SPLITTABLE NEEDLE INTRODUCER
TM
1.2Fr (28G)
25cm
S/L L-CathTM PICC Basic Kit with Splittable Needle Introducer
ARGON L-CATHTM POLYURETHANE PICC DUAL LUMEN BASIC KIT WITH BD INTROSYTETM AUTOGUARDTM SHIELDED INTRODUCER
5Fr (16G)
60cm
D/L L-CathTM PICC Basic Kit with BD IntrosyteTM AutoguardTM
5
384584
3.5Fr (18G)
60cm
D/L L-CathTM PICC Basic Kit with BD IntrosyteTM AutoguardTM
5
384575
3Fr (20G)
60cm
D/L L-Cath PICC Basic Kit with BD Introsyte Autoguard
5
384566
TM
TM
TM
ARGON L-CATHTM POLYURETHANE MIDLINE SINGLE LUMEN BASIC KIT WITH BD INTROSYTETM AUTOGUARDTM SHIELDED INTRODUCER
3.5Fr (18G)
20cm
S/L L-CathTM Midline Basic Kit with BD IntrosyteTM AutoguardTM
5
384635
3Fr (20G)
20cm
S/L L-CathTM Midline Basic Kit with BD IntrosyteTM AutoguardTM
5
384631
Description
Argon L-CathTM Polyurethane PICC and Midline Catheter-Only Set contents:
Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement.
Argon L-CathTM Polyurethane PICC and Midline Basic Kit Set contents:
BD IntrosyteTM AutoguardTM Shielded Introducer; Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm
measurement.
Argon L-CathTM 1.2Fr (28G) Polyurethane PICC Basic Kit Set contents:
Argon 1.2Fr (28G) Splittable Needle Introducer; Polyurethane Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm
measurement.
Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD IntrosyteTM and IntrosyteTM AutoguardTM Shielded Introducers are available via your local BD Agent.
These BD IntrosyteTM and IntrosyteTM AutoguardTM introducers incorporate the BD AutoguardTM needle-shielding technology.
Peripherally Inserted Central Catheters (PICC and Midline Catheters)
Argon First PICCTM Silicone PICC and
Midline Catheters
Sterile, single use
Argon First PICCTM Silicone PICC and Midline Catheters
Gauge
Length (cm)
Description
Box/Case
Content (Units)
Product
Code
ARGON First PICCTM SILICONE PICC SINGLE LUMEN CATHETER ONLY
5Fr (16G)
65cm
S/L First PICCTM, Catheter Only
5
384158
4Fr (18G)
65cm
S/L First PICCTM, Catheter Only
5
384157
3Fr (20G)
65cm
S/L First PICC , Catheter Only
5
384156
2.8Fr (22G)
50cm
S/L First PICC , Catheter Only
5
384101
1.9Fr (26G)
50cm
S/L First PICCTM, Catheter Only
5
384232
D/L First PICCTM, Catheter Only
5
384159
TM
TM
ARGON First PICC SILICONE PICC DUAL LUMEN CATHETER ONLY
TM
5Fr (16G)
65cm
ARGON First MIDCATH SILICONE MIDLINE SINGLE LUMEN CATHETER ONLY
TM
4Fr (18G)
20cm
S/L First MidcathTM Midline, Catheter Only
5
384358
3Fr (20G)
20cm
S/L First Midcath Midline, Catheter Only
5
384357
TM
ARGON First PICCTM SILICONE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTETM AUTOGUARDTM SHIELDED INTRODUCER
5Fr (16G)
65cm
S/L First PICCTM Basic Kit with BD IntrosyteTM AutoguardTM
5
384177
4Fr (18G)
65cm
S/L First PICCTM Basic Kit with BD IntrosyteTM AutoguardTM
5
384171
3Fr (20G)
65cm
S/L First PICC Basic Kit with BD Introsyte Autoguard
5
384115
5
384221
5
384183
TM
TM
TM
ARGON First PICC SILICONE PICC SINGLE LUMEN BASIC KIT WITH BD INTROSYTE-N INTRODUCER
TM
TM
1.9Fr (26G)
50cm
S/L First PICCTM Basic Kit with BD Introsyte-NTM Introducer
ARGON First PICC SILICONE PICC DUAL LUMEN BASIC KIT WITH BD INTROSYTE AUTOGUARD SHIELDED INTRODUCER
TM
TM
5Fr (16G)
65cm
TM
D/L First PICCTM Basic Kit with BD IntrosyteTM AutoguardTM
ARGON First MIDCATH SILICONE MIDLINE SINGLE LUMEN BASIC KIT WITH BD INTROSYTE AUTOGUARD SHIELDED INTRODUCER
TM
TM
TM
4Fr (18G)
20cm
S/L First MidcathTM Midline Basic Kit with BD IntrosyteTM AutoguardTM
5
384308
3Fr (20G)
20cm
S/L First Midcath Midline Basic Kit with BD Introsyte Autoguard
5
384304
TM
TM
TM
Description
Argon First PICCTM Silicone PICC and Midline Catheter-Only Set contents:
Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with 1cm measurement.
Argon First PICCTM Silicone PICC and Midline Basic Kit Set contents:
BD IntrosyteTM AutoguardTM Shielded Introducer; Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with
1cm measurement.
Argon First PICCTM 1.9Fr (26G) Silicone PICC Basic Kit Set contents:
BD Introsyte-NTM 1.9Fr (26G) Introducer; Silicone Catheter with 1cm depth markings; Catheter Cutting tool; Paper tape measure with
1cm measurement.
Note: Stand-alone 1.9Fr (26G) to 5Fr (16G) BD IntrosyteTM and IntrosyteTM AutoguardTM Shielded Introducers are available via your local BD Agent.
These BD IntrosyteTM and IntrosyteTM AutoguardTM introducers incorporate the BD AutoguardTM needle-shielding technology.
Central Venous Catheters
Argon FloswitchTM
Sterile, single use
Description
Argon Connecta FloswitchTM
Box/Case Content (Units)
Product Code
25/250
681033
Argon FloswitchTM acts as an ON/OFF device on infusion lines, stopping the flow in order to carry out line
procedures in closed circuit.
Reduces the risk of patient emboli and potential contamination of hospital staff by exposure to blood.
The FloswitchTM therefore considerably increases safety.
Argon FloswitchTM can be connected to any catheter fitted with a Luer connector.
Winged to facilitate attachment.
FloswitchTM closed
External compression of the extension tubing by means
of a steel ball, provides risk-free unambiguous opening
and closing of the infusion line.
FloswitchTM open
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Central Venous Catheters
Argon Secalon-TTM
Sterile, single use
Gauge
Length
Catheter External Diameter
Colour
Box/Case Content (Units)
Flow Rate (ml/min)
Product Code
18G
90mm
1.2mm
Green
25/250
55
681000
16G
130mm
1.7mm
Grey
25/250
139
681002
16G
160mm
1.7mm
Grey
25/250
128
681004
14G
160mm
2.0mm
Orange
25/250
206
681006
Argon Secalon-TTM emergency catheter designed for high flow rate infusions.
FEP (Fluorinated Ethylene Propylene) material construction and incorporating a FloswitchTM, Argon Secalon-TTM is ideal for
rapid short-term insertion into central veins or large peripheral vessels.
Complete kit contains pre-puncture stylus and stabilising wing.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (maximum)
Sterilisation method: Ethylene Oxide
Central Venous Catheters
Argon CareflowTM Single Lumen
Central Venous Catheters
Sterile, single use
External
Diameter
Length
Cannula Introducer
Gauge
Length
FloswitchTM Introducer
Gauge
Length
Needle Introducer
Gauge
Length
Guidewire
OD &
Length
Secondary
Fixation
(SFD)
Box/Case
Content
(Units)
Flow Rate
(ml/min)
D
Code
without
FloswitchTM
Code
with
FloswitchTM
ARGON CAREFLOWTM SINGLE LUMEN SETS WITHOUT EXTENSION
2.5Fr (22G)
100mm
N/A
N/A
20G
45mm
22G
40mm
0.5 x 350mm
10/100
10
681614
681623
3Fr (20G)
150mm
N/A
N/A
20G
45mm
22G
40mm
0.5 x 350mm
10/100
16
681639
681640≠
3Fr (20G)
200mm
N/A
N/A
20G
45mm
22G
40mm
0.5 x 450mm
10/100
15
681643
681644
4Fr (18G)
200mm
N/A
N/A
18G
60mm
17G
70mm
0.6 x 450mm
10/100
36
681649
681650
5Fr (16G)
150mm
N/A
N/A
15G
70mm
17G
70mm
0.9 x 450mm
Yes
10/100
71
681669
681670
5Fr (16G)
200mm
N/A
N/A
15G
70mm
17G
70mm
0.9 x 450mm
Yes
10/100
63
681672
681673
7Fr (14G)
150mm
N/A
N/A
14G
70mm
17G
70mm
0.9 x 450mm
Yes
10/100
190
681706
681707
7Fr (14G)
200mm
N/A
N/A
14G
70mm
17G
70mm
0.9 x 450mm
Yes
10/100
136
681709
681710
Argon CareflowTM is a range of paediatric and adult polyurethane central venous catheters designed for catheterisation by
the Seldinger technique.
Available in single, double, triple, quadruple and quint lumen formats, this range of sets contains a NiTiNol guidewire and
the Argon VenaguideTM Seldinger wire advancing device facilitating single handed guidewire insertion.
Argon CareflowTM catheters are latex free with tapered atraumatic catheter tip reducing the risk of venous damage and
improving catheter insertion.
The streamlined junction hub enables ease of catheter suture and comfortable positioning on the patients skin.
Argon CareflowTM catheters offer 1cm and 5cm interval depth markings to facilitate catheter placement and clear lumen
size and hub colour coding indication.
Argon FloswitchTM and Argon FloswitchTM introducer catheter options available throughout range.
Argon CareflowTM central venous catheters are pressure rated with a maximum pressure tolerance of 45 psi.
Description
Single lumen Argon CareflowTM with Argon FloswitchTM set contents:
Argon CareflowTM Polyurethane catheter, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel dilator, Argon VenaguideTM Seldinger
wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system, luer lock plug and secondary fixation device (where shown).
Single lumen Argon CareflowTM without Argon FloswitchTM set contents:
Argon CareflowTM Polyurethane catheter, steel needle introducer, vessel dilator, Argon VenaguideTM Seldinger wire advancing device with NiTiNol guidewire
and secondary fixation device (where shown).
≠ Note: Part number 681640 contains 0.5 x 450mm guidewire.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Central Venous Catheters
Argon CareflowTM Single Lumen
Central Venous Catheter Sets
1
2
Sterile, single use
3
4
External
Diameter
Length
Cannula Introducer
Gauge
Length
FloswitchTM Introducer
Gauge
Length
Needle Introducer
Gauge
Length
Guidewire
OD &
Length
Secondary
Fixation
(SFD)
Box/Case
Content
(Units)
Flow Rate
(ml/min)
D
Code
without
FloswitchTM
Code
with
FloswitchTM
1. ARGON CAREFLOWTM SINGLE LUMEN SETS WITH EXTENSION
2.5Fr (22G)
60mm
22G
38mm
N/A
N/A
22G
40mm
0.5 x 350mm
5/50
12
681612
2.5Fr (22G)
100mm
22G
38mm
N/A
N/A
22G
40mm
0.5 x 350mm
5/50
10
681622
2.5Fr (22G)
200mm
22G
38mm
N/A
N/A
22G
40mm
0.5 x 650mm
5/50
7
681634
3Fr (20G)
150mm
20G
45mm
N/A
N/A
22G
40mm
0.5 x 450mm
5/50
18
681647
3Fr (20G)
200mm
20G
45mm
N/A
N/A
22G
40mm
0.5 x 650mm
5/50
15
681638
4Fr (18G)
60mm
20G
45mm
N/A
N/A
22G
40mm
0.5 x 350mm
5/50
47
681624
4Fr (18G)
200mm
20G
45mm
N/A
N/A
22G
40mm
0.5 x 650mm
5/50
35
651658
5Fr (16G)
150mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 450mm
Yes
5/50
65
681662
5Fr (16G)
200mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 700mm
Yes
5/50
60
681666
5Fr (16G)
300mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 700mm
Yes
5/50
46
681679
7Fr (14G)
150mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 450mm
Yes
5/50
159
681698
7Fr (14G)
200mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 700mm
Yes
5/50
149
681699
7Fr (14G)
300mm
16G
70mm
N/A
N/A
17G
70mm
0.9 x 700mm
Yes
5/50
136
681701
22G
40mm
0.5 x 450mm
10/100
7
681633
2. ARGON CAREFLOWTM SINGLE LUMEN SET WITH ARGON FLOSWITCHTM
2.5Fr (22G)
200mm
N/A
N/A
20G
45mm
3. ARGON CAREFLOW SINGLE LUMEN WITH INTEGRAL ARGON FLOSWITCH
TM
TM
5Fr (16G)
150mm
N/A
N/A
15G
70mm
17G
70mm
0.9 x 450mm
Yes
10/100
65
681660
5Fr (16G)
200mm
N/A
N/A
15G
70mm
17G
70mm
0.9 x 700mm
Yes
10/100
60
681664
5Fr (16G)
300mm
N/A
N/A
15G
70mm
17G
70mm
0.9 x 700mm
Yes
10/100
46
681678
4. ARGON CAREFLOW SINGLE LUMEN WITH EXTENSION AND ARGON FLOSWITCH
TM
TM
2.5Fr (22G)
60mm
N/A
N/A
20G
45mm
22G
40mm
0.5 x 350mm
5/50
12
681615
4Fr (18G)
60mm
N/A
N/A
20G
45mm
22G
40mm
0.5 x 350mm
5/50
47
681625
Description
1. Single lumen Argon CareflowTM set with extension contents†:
Argon CareflowTM Polyurethane catheter with clear extension, extension slide clamp, cannula introducer, steel needle introducer, vessel dilator, Argon
VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon Luer-LokTM plug, secondary fixation device (where shown) and 5ml syringe.
2. Single lumen Argon CareflowTM set with Argon FloswitchTM contents:
Argon CareflowTM Polyurethane catheter with clear extension, steel needle introducer, Argon FloswitchTM overneedle introducer, PTFE coated soft-tip
straight guidewire and Argon FloswitchTM revolving Luer-LokTM system, luer lock plug.
3. Single lumen Argon CareflowTM set with integral Argon FloswitchTM contents§:
Argon CareflowTM Polyurethane catheter with clear extension and integral Argon FloswitchTM, Argon FloswitchTM overneedle introducer, steel needle
introducer, vessel dilator, Argon VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon Luer-LokTM plug and secondary fixation device.
4. Single lumen Argon CareflowTM set with extension and Argon FloswitchTM contents†:
Argon CareflowTM Polyurethane catheter with clear extension, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel dilator, Argon
VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system and luer lock plug.
Latex free
Sterilisation method: Ethylene Oxide
CE marked
†
Shelf life: 5 years
Class lll according to the European Medical Devices Directive
93/42/EEC as amended by Directive 2007/47/EC
(§ except 681660, 681664 & 681678 which have a 3 year shelf life.)
Sterile double tray packaging for increased safety
Central Venous Catheters
Argon CareflowTM Double & Triple Lumen
Central Venous Catheter Sets
Sterile, single use
External
Diameter
Length
Cannula Introducer
Gauge
Length
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
FloswitchTM Introducer
Needle Introducer
Secondary
Fixation
(SFD)
Box/Case
Content
(Units)
Flow Rate
(ml/min)
D
M
P
Code
without
FloswitchTM
Code
with
FloswitchTM
ARGON CAREFLOWTM DOUBLE LUMEN SETS
4Fr (20G, 22G)
60mm
20G
45mm
20G
45mm
22G
40mm
0.5 x 350mm
5/50
20
8
681616
681617
4Fr (20G, 22G)
100mm
20G
45mm
20G
45mm
22G
40mm
0.5 x 350mm
5/50
19
6
681626
681627
4Fr (20G, 22G)
150mm
20G
45mm
20G
45mm
22G
40mm
0.5 x 450mm
5/50
16
4
681653
681652
4Fr (20G, 22G)
200mm
20G
45mm
20G
45mm
22G
40mm
0.5 x 450mm
5/50
17
4
681656≠
681655
5Fr (18G, 20G)
60mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 450mm
Yes
5/50
40
10
681619
681628
5Fr (18G, 20G)
150mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 450mm
Yes
5/50
29
6
681683
681682
5Fr (18G, 20G)
200mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 650mm
Yes
5/50
30
6
681687
681686
7Fr (16G, 18G)
150mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 450mm
Yes
5/50
74
24
681703
681702
7Fr (16G, 18G)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
73
21
681714
681713
7Fr (16G, 18G)
300mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
61
19
681718
681717
Description
Double lumen Argon CareflowTM with Argon FloswitchTM set contents:
Argon CareflowTM double lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel
dilator, Argon VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system, luer lock plugs and
secondary fixation device (where shown).
Double lumen Argon CareflowTM without Argon FloswitchTM set contents:
Argon CareflowTM double lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon VenaguideTM
Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, luer lock plugs and secondary fixation device (where shown).
≠ Note: Part number 681656 contains 0.5 x 650mm guidewire.
External
Diameter
Length
Length
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
Cannula Introducer
Gauge
FloswitchTM Introducer
Needle Introducer
Secondary
Fixation
(SFD)
Box/Case
Content
(Units)
Flow Rate
(ml/min)
D
M
P
Code
without
FloswitchTM
Code
with
FloswitchTM
ARGON CAREFLOW TRIPLE LUMEN SETS
TM
5Fr (18G, 20G, 20G)
60mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 450mm
Yes
5/50
40
10
12
681620
681629
5Fr (18G, 20G, 20G)
100mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 450mm
Yes
5/50
32
7
8
681630
681618
5Fr (18G, 20G, 20G)
150mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 450mm
Yes
5/50
29
5
6
681691
681690
5Fr (18G, 20G, 20G)
200mm
18G
60mm
18G
60mm
17G
70mm
0.6 x 650mm
Yes
5/50
26
5
5
681695
681694
7Fr (16G, 18G, 18G)
150mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 450mm
Yes
5/50
66
22
23
681721
681720
7Fr (16G, 18G, 18G)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
59
16
17
681725
681724
7Fr (16G, 18G, 18G)
300mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
53
11
9
681729
681728
Description
Triple lumen Argon CareflowTM with Argon FloswitchTM set contents:
Argon CareflowTM triple lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel dilator, Argon
VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system, luer lock plugs and secondary fixation device.
Triple lumen Argon CareflowTM without Argon FloswitchTM set contents:
Argon CareflowTM triple lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon VenaguideTM
Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, luer lock plugs and secondary fixation device.
Latex free
CE marked
Class lll according to the European Medical Devices
Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Sterile double tray packaging for increased safety
Central Venous Catheters
Argon CareflowTM Quad & Quint Lumen
Central Venous Catheter Sets
Sterile, single use
External
Diameter
Length
Cannula Introducer
FloswitchTM Introducer
Gauge
Length
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
Box/Case
Content
(Units)
D
M1
M2
P1
Needle Introducer
Flow Rate (ml/min)
P2
Code
without
FloswitchTM
Code
with
FloswitchTM
ARGON CAREFLOWTM QUAD LUMEN SETS
8.5Fr (14G, 16G, 16G, 18G)
150mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 450mm
5/50
64
82
57
20
681731
681732
8.5Fr (14G, 16G, 16G, 18G)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
5/50
58
76
45
19
681733
681734
Description
Quad lumen Argon CareflowTM with Argon FloswitchTM set contents:
Argon CareflowTM quad lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel dilator,
Argon VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system, scalpel, luer lock plugs and
secondary fixation device.
Quad lumen Argon CareflowTM without Argon FloswitchTM set contents:
Argon CareflowTM quad lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon VenaguideTM
Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, scalpel, luer lock plugs and secondary fixation device.
External
Diameter
Length
Cannula Introducer
FloswitchTM Introducer
Gauge
Length
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
Box/Case
Content
(Units)
D
M1
M2
P1
Needle Introducer
P2
Code
without
FloswitchTM
Code
with
FloswitchTM
Flow Rate (ml/min)
ARGON CAREFLOWTM QUINT LUMEN SETS
9.5Fr (14G, 16G, 16G, 18G, 18G)
150mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 450mm
5/50
73
61
65
19
21
681735
681736
9.5Fr (14G, 16G, 16G, 18G, 18G)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
5/50
68
58
60
13
12
681737
681738
Description
Quint lumen Argon CareflowTM with Argon FloswitchTM set contents:
Argon CareflowTM quint lumen Polyurethane catheter with clear extensions, steel needle introducer, Argon FloswitchTM overneedle introducer, vessel dilator,
Argon VenaguideTM Seldinger wire advancing device with NiTiNol guidewire, Argon FloswitchTM revolving Luer-LokTM system, scalpel, luer lock plugs and
secondary fixation device.
Quint lumen Argon CareflowTM without Argon FloswitchTM set contents:
Argon CareflowTM quint lumen Polyurethane catheter with clear extensions, cannula introducer, steel needle introducer, vessel dilator, Argon VenaguideTM
Seldinger wire advancing device with NiTiNol guidewire, extension slide clamps, 5ml syringe, scalpel, luer lock plugs and secondary fixation device.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Sterile double tray packaging for increased safety
Central Venous Catheters
Argon Hydrocath AssureTM Antimicrobial
Coated Central Venous Catheters
Sterile, single use
External
Diameter
Length
Cannula Introducer
Gauge
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
N/A
N/A
17G
70mm
0.9 x 700mm
FloswitchTM Introducer
Length
Needle Introducer
Secondary
Fixation
(SFD)
Box/Case
Content
(Units)
Flow Rate
(ml/min)
D
M2 P2
Code
without
FloswitchTM
Code
with
FloswitchTM
ARGON HYDROCATH ASSURETM SINGLE LUMEN SETS
5Fr (16)
200mm
16G
70mm
5/50
56
681161
ARGON HYDROCATH ASSURETM DOUBLE LUMEN SETS
7Fr (16+18)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
69
22
681152
681150
7Fr (16+18)
300mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
61
17
681153
681151
15G
70mm
17G
70mm
0.9 x 450mm
Yes
5/50
68
24
681157
681154
ARGON HYDROCATH ASSURETM TRIPLE LUMEN SETS
7Fr (16, 18+18)
150mm
16G
70mm
22
7Fr (16, 18+18)
200mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
58
18
19
681158
681155
7Fr (16, 18+18)
300mm
16G
70mm
15G
70mm
17G
70mm
0.9 x 700mm
Yes
5/50
50
13
13
681159
681156
An innovative approach to risk management:
Argon Hydrocath AssureTM is a range of single, double and triple lumen polyurethane central venous catheters, designed
for catheterisation by the Seldinger technique.
Every catheter is coated with a hydrophilic substance activated by biological fluids, which facilitates the insertion of the
catheter and reduces the potential adhesion of bacteria or formation of thrombus.
In addition, the Hydromer hydrophilic matrix is impregnated with the antimicrobial agent Benzalkonium Chloride (BZC).
BZC is bactericidal against a broad spectrum of microorganisms which are known to colonise central venous catheters.
Argon Hydrocath AssureTM has been proven to reduce bacterial colonisation of catheters in critically ill patients1.
Description
All of the above sets contain:
BZC impregnated and hydrophilic coated polyurethane catheter, Argon VenaGuideTM Seldinger wire advancing system with NiTiNol guidewire, needle
introducer, vein dilator, secondary fixation device as shown and luer lock plugs.
All sets without Argon FloswitchTM contain a cannula introducer, needle introducer, sliding clamps and 5ml syringe.
All Argon FloswitchTM sets include an Argon FloswitchTM revolving Luer-LokTM system, Argon FloswitchTM cannula introducer and needle introducer.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Sterile double tray packaging for increased safety
1
Moss MA, Tebbs SE, Faroqui MH, Herbst T, Isaac JL, Brown J, Elliott TSJ, “A central venous catheter coated with Benzalkonium Chloride for the prevention of catheterrelated microbial colonisation”. Eur J Anaesth 2000, 17, 680-687.
Arterial Catheters
Argon CareflowTM Arterial Catheters
Sterile, single use
Gauge
Length
Guidewire
OD &
Length
Box/Case
Content
(Units)
Priming Volume
(ml)
Flow Rate
(ml/min)
Product Code
60mm
22G
40mm
0.5 x 250mm
10/100
0.08
12.4
681631
3Fr (20G)
60mm
22G
40mm
0.5 x 250mm
10/100
0.08
24.0
681646
3Fr (20G)
200mm
22G
40mm
0.5 x 450mm
10/100
0.14
15.4
681642
4Fr (18G)
200mm
17G
70mm
0.6 x 450mm
10/100
0.24
35.8
681648
Catheter External
Diameter
Length
Radial artery set
2.5Fr (22G)
Radial artery set
Femoral artery set
Femoral artery set
Product
Needle Introducer
Argon CareflowTM Polyurethane catheters are designed for access to radial or femoral arteries, for the determination of
blood parameters or monitoring blood pressure.
Catheterisation trays contain an introducer needle, metal guidewire and Luer LokTM plug.
Latex free
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Pulmonary Artery and Thermodilution Systems
Argon Percutaneous Sheath
Introducer Sets
Sterile, single use
Argon ExactaTM Percutaneous Sheath Introducers for the Introduction of Pulmonary Artery Catheters.
Size*
Introducer
Length
Gauge
Length
Gauge
Length
Guidewire
OD &
Length
Contamination
Shield
Length
High-Flow
Stopcock
Syringe
Scalpel
Obturator
Box/Case
Content
(Units)
Product
Code
6Fr
110mm
16G
70mm
17G
70mm
0.9 x 450mm
800mm
Yes
Yes
Yes
Yes
5/50
680128
7Fr
110mm
16G
70mm
17G
70mm
0.9 x 450mm
800mm
Yes
Yes
Yes
Yes
5/50
680140
8Fr
110mm
16G
70mm
17G
70mm
0.9 x 450mm
800mm
Yes
Yes
Yes
Yes
5/50
680126
Link Kit 8.5Fr
110mm
16G
70mm
17G
70mm
0.9 x 450mm
-
Yes
Yes
Yes
Yes
5/50
680132
8.5Fr
110mm
16G
70mm
17G
70mm
0.9 x 450mm
800mm
Yes
Yes
Yes
Yes
5/50
680124
Cannula Introducer
Needle Introducer
* for introduction of 1Fr smaller size catheters
Argon Tuohy Borst Percutaneous Introducers for the Introduction of Pulmonary Artery Catheters.
Size*
Introducer Length
Guidewire
OD & Length
Vessel Dilator
Stopcock
Box/Case
Content (Units)
Product
Code
6Fr
110mm
0.035” x 450mm
6Fr
Yes
10
496132
7Fr
110mm
0.035” x 450mm
7Fr
Yes
10
496133
8Fr
110mm
0.035” x 450mm
8Fr
Yes
10
496134
8.5Fr
110mm
0.035” x 450mm
8.5Fr
Yes
10
496135
9Fr
110mm
0.035” x 450mm
9Fr
Yes
10
496136
* for introduction of 1Fr smaller size catheters
Accessories
Description
Septishield Catheter Sleeve
Size/Length
Box/Case
Content (Units)
Product
Code
800mm
25
497302
Obturator for 5Fr-6Fr x 11cm Introducer Sheaths
5Fr
10
00-392404
Obturator for 7Fr-9Fr x 11cm Introducer Sheaths
7Fr
10
00-392403
A complete range of percutaneous sheath introducer systems
•
•
•
•
•
•
Radiopaque FEP sheath with integral sidearm
Tuohy Borst adapter and haemostasis valve
Matched dilator with luer lock collar
Individually packed and sterile
Argon ExactaTM sets include a contamination shield with Tuohy Borst lock
Two separately packaged sterile obturators supplied per box of 5
Argon ExactaTM sheath systems
How Argon percutaneous introducers can benefit you
•
•
•
•
Radiopaque FEP sheath reduces risk of thrombus formation in situ
Flexible hub minimises potential for kinking of introducers
Suture point facilitates skin fixation
Profiled sheath tip and matched dilator facilitates smooth, atraumatic
insertion
• Dilator luer locking collar secures dilator to sheath hub during insertion
• Tuohy Borst adapter minimises catheter migration and improves
catheter control
• Latex free, self-sealing haemostasis valve minimises risk of blood loss
• Argon ExactaTM sets include the Argon VenaguideTM Seldinger wire
advancing device which allows single-handed wire insertion
• Argon ExactaTM sets include sterile double tray packaging for
increased safety
Latex free (except part number 680132 which contains latex)
CE marked
Class lll (Exacta) or Class IIa (Tuohy Borst) according to
the European Medical Devices Directive 93/42/EEC as
amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Pulmonary Artery and Thermodilution Systems
Argon CriticathTM Pulmonary Artery Catheters
for Monitoring Right Heart Pressures and
Cardiac Output Measurements
Sterile, single use
Catheters for Monitoring Right Heart Pressures and Cardiac Output Measurement
Model
Size
Length
No. of
Lumens
PA Wedge
Pressure
CV
Pressure
Cardiac
Output
SP5105H
5Fr
80cm
4
Yes
Yes
Yes
CVP Medic.
port
Ventric.
placing
Heparinised
Additional Information
Yes
Box/Case
Content
(Units)
Product
Code
5/20
680084
SP5107
7Fr
110cm
4
Yes
Yes
Yes
No
5/20
680098
SP5107H
7Fr
110cm
4
Yes
Yes
Yes
Yes
5/20
680078
SP5107H-14
7Fr
110cm
4
Yes
Yes
Yes
Yes
Pre-mounted Luer-LokTM AC shield
5/20
680088
SP5107+SP5045
7Fr
110cm
4
Yes
Yes
Yes
No
Pre-mounted In-Line Inject, sensor
5/20
680099
SP5107H+SP5045
7Fr
110cm
4
Yes
Yes
Yes
Yes
Pre-mounted In-Line Inject, sensor
5/20
680077
SP5127
7Fr
110cm
4
Yes
Yes
Yes
No
“S” shaped, to facilitate femoral insertion
5/20
680104
SP5127H
7Fr
110cm
4
Yes
Yes
Yes
Yes
“S” shaped, to facilitate femoral insertion
5/20
680089
7Fr
110cm
5
Yes
Yes
Yes
Yes
No
5/20
680102
SP5507H
SP5507
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
Yes
5/20
680082
SP5507H-14
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
Yes
Pre-mounted Luer-LokTM AC shield
5/20
680093
SP5507HS
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
Yes
“Soft” version
5/20
680080
SP5507+SP5045
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
No
Pre-mounted In-Line Inject, sensor
5/20
680100
SP5537
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
No
5/30
680106
SP5537H
7.5Fr
110cm
5
Yes
Yes
Yes
Yes
Yes
5/30
680081
Description
•
•
•
•
•
•
A range of flow directed, balloon tipped catheters for both adult and paediatric use
Use for monitoring right heart pressures and obtaining venous blood samples
Thermodilution technique used to measure Cardiac Output
Options include temporary ventricular pacing and ‘S’ tipped for femoral insertion
Also available in hard and soft versions
Individually packed, sterile and non-pyrogenic
How Argon CriticathTM can benefit you
•
•
•
•
•
•
Rounded catheter tip design allows for smooth insertion and reduces risk of vessel trauma
Heparin coating minimises risk of thrombus formation
Strong circular lumen design reduces kinking and enhances pressure signal transfer
Catheter depth markings facilitate accurate placement and catheter manipulation
Smooth balloon/catheter junction reduces risk of balloon rupture and thrombus formation
Some models have a pre-mounted in-line injectate sensor housing or an anticontamination (AC) sheath on the catheter for user
convenience
Note: pulmonary artery balloon contains latex.
CE marked
Class lll according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 2 years
Sterilisation method: Ethylene Oxide
Pulmonary Artery and Thermodilution Systems
Argon CritikitTM Ice/Room Temperature
Injectate Systems and Accessories
Sterile, single use
Closed Loop In-Line Injectate Systems for Improved Accuracy of Cardiac Output Measurement
Description
Sterile
Box/Case
Content (Units)
Product Code
Ice/Room temperature Injectate Critikit (with in-line sensor, control syringe & cooling coil)
Yes
4/8
680000
Ice/Room temperature Injectate Critikit (with in-line sensor and control syringe, without cooling coil)
Yes
5/20
680178
In-line injectate sensor housing
Yes
25/250
680006
10cc control syringe
Yes
10/50
682155
Model
SP4500
SP5045
Spectraject
Description
•
•
•
•
Available in both iced and room temperature injectate options
Closed circuit design offers an aseptic approach to cardiac output measurement
Individually packed, sterile, non-pyrogenic and latex-free
Set comprises an injectate sensor housing with three way stopcock, one way check valve, Spectraject 10cc syringe, cooling coil, delivery tubing and
IV spike
How Argon CritikitTM can benefit you
• Closed loop system reduces risk of line contamination
• Insulated volume-restricted syringe facilitates precise and reproducible injectate
• In-line injectate sensor optimises accuracy of temperature readings
• Syringe design allows smooth injectate action improving data validity
Note: The CritikitTM injectate system and Spectraject control syringe contain latex (Spectraject syringe stopper)
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Non-Sterile Accessories
Description
Sterile
Box/Case
Content (Units)
Product Code
SP4042
In-line injectate sensor cable. For use with Abbott Oximetrix, Arrow, Baxter
Edwards 9520A or Com1, Mennen Horizon 2000 Series (cable 800-030-200),
Spacelabs Alpha PC or PCMS (bifurcated cable model 306655-001), Datex AS3
and Critikit Injectate set or SP5045 sensor housing.
No
1
684056
SP4043
In-line injectate sensor cable. For use with Siemens bifurcated cable, Siemens Pod system (Model
8419145) and Critikit Injectate set or SP5045 sensor housing.
No
1
684057
SP4045
In-line injectate sensor cable. For use with HemoPro (SP1445), Nikon Kohden,
Spacelabs (bifurcated cable model 306655-002), Fukuda Denshi IB5006 (DSCP),
Dynascope DS3300 and Critikit Injectate set or SP5045 sensor housing.
No
1
684062
SP4046
In-line injectate sensor cable. For use with Hewlett Packard Cardiac Output Module (HP trifurcated cable
M1641A or M1642A) and Critikit Injectate set or SP5045 sensor housing.
No
1
684063
Model
Latex free
CE marked
Class l according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Disposable Pressure Transducer
Argon DTX PlusTM Disposable Pressure Transducer Sets
Designed for ease of use and minimal wavelength distortion
Haemodynamic monitoring information is used to manage the care of critically ill patients. It is therefore essential that you are
confident about the accuracy of the information that you are using. Fluid filled pressure monitoring systems will cause some
distortion to the pressure waveform. Up to 40% distortion has been shown in some cases.1
Accuracy in pressure monitoring isn’t just dependent on the transducer, it’s dependent on all the components in the pressure
monitoring system; catheter, pressure tubing, monitor filter and stopcocks. It has been shown2 that in order to know the accuracy
of your system, you need to consider the performance of the total chain where all the components are linked together.
As a manufacturer we believe we have a responsibility to provide you with
information about the accuracy of the whole monitoring system, not just the
transducer. Therefore, Argon has selected a range of standard Argon DTX
PlusTM sets which are Gabarith tested.2
The Argon GabarithTM test remains the only scientific technique that provides
information about the dynamic response performance of the total pressure
monitoring system (total chain).
The Argon GabarithTM test assesses the system against pre-set windows of error
(2%, 5% and 10% waveform distortion). For example: If the dynamic response
of a pressure chain falls within the 10% Gabarith window then we know the
pressure waveform will not be distorted by more than 10%.3
PRESSURE OUT
PRESSURE IN
TESTED SET
ACCEPTED
AS WITHIN
GABARITH
WINDOW
GABARITH
WINDOW OF
TOLERANCE
TESTED SET
DISCARDED
AS OUTSIDE
GABARITH
WINDOW
1
DYNAMIC
RESPONSE
0
10
20
Hz
Example of Radial Artery pressure
10% error Gabarith window
(for adult kit)
Windows of tolerance are based on catheter tip sensor results (the ’gold’ standard) using real patient data.
Every box of Argon DTX PlusTM pressure monitoring sets is stamped with the Argon GabarithTM symbol. This shows that the set
has passed the Argon GabarithTM test and has a known level of accuracy. The Argon GabarithTM test exceeds the demands of
the AAMI standard (Association for the Advancement of Medical Instrumentation).
References:
1 Anesthesiology 53: 498-504, 1980; British Journal of Anaesthesia 1987, 59, 901-912; European Academy of Anaesthesiology - Strasbourg Aug/Sep 1997 (Bender HJ, Billiet E et al).
2 Billiet E, Colardyn F. (1998) Pressure Measurement Evaluation and Accuracy: The Gabarith Test. Intensive Care Medicine 24:1323-1326
3 Assuming that the set has been set up and zeroed in accordance with manufacturing instructions
Argon DTX PlusTM Disposable Pressure Transducer Sets Specifications
Detail
Argon DTX PlusTM specifications
Environmental performance:
a) storage temperatures
b) operating temperatures
c) humidity
d) atmospheric pressure
-25ºC to 70ºC
15ºC to 40ºC
10% to 90%
425 to 850 torr
Pressure range:
a) operating pressure
b) overpressure withstand
-30 to 300 mmHg
-700 to 7,755 mmHg
Mounting requirement:
Will meet performance requirements when mounted on any axis
Frequency response (Stand-alone Transducer):
15% bandwidth shall be >200 Hz
Transducer excitation:
DC to 5,000 Hz 4 to 8 V RMS
Phase shift:
<5°
Transducer excitation impedance (input impedance):
>200 ohms
Transducer signal impedance (output impedance):
<3,000 ohms
Transducer symmetry:
±5%
Nominal sensitivity (gain):
5 µV/V/mmHg
Unbalance (zero balance):
±40 mmHg
Accuracy:
The maximum error due to the total effects of nonlinearity, hysteresis and sensitivity variations shall be no
more than 2% of the reading or ±1 mmHg, whichever is greater, over the operating range.
Risk current:
<2µA
Defibrillator withstand:
Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all
transducer wires are shorted and saline is in fluid column
Requirements for the cable:
a) cable length stated
b) transducer venting to atm.
c) cable will withstand five repeated discharges in 5 minutes of 360J sinusoidal energy
delivered into 50 ohms when all wires are shorted and foil surrounds the cable
Cable length stated
Venting to atmosphere
Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all
wires are shorted and foil surrounds the cable
Flow Rate, DTX Plus transducers:
2 – 4 cc/hr or 20 – 40cc/hr, depending on model, with an infusion pressure (difference) of 200mmHg.
Fast Flush Rate, DTX Plus transducers:
Min 50cc/min using a microdrip administration set with 60 inch of IV tubing with an infusion pressure
(difference) of 200mmHg.
DTX Plus Transducer dimensions (inc Flush and Zero stopcock):
Max Length: 8.4cm (Inc zero stopcock and male luer fitting); Max Width: 3.2cm; Max Height: 3cm (Inc EasyVent Deadender on Zero stopcock). Length of Transducer electric cable: 34.5cm
Disposable Pressure
16/2/05 3:32Transducer
pm Page 15
Critical Care catalogue 2005
Pressure Transducer Sets
BD DTX PlusTM Disposable
Argon DTX
Plus Disposable Pressure
Pressure
Transducers
TM
Transducers
Sterile, single use
Sterile, single use
• BD
offers aoffers
wide range
of disposable
anddisposable
reusable transducers.
Argon
a wide
range of
transducers
and transducer sets
• BD’s experience is based on decades of research and development reaching back to the first practical blood pressure transducer
introduced
Model by Gould-Statham.
Description
ModelDT-XX
DT-NN
DT-XX
DT-XO
Box/Case
Content (Units)
Product
Code
10/100
682018
10/100
682019
10/100
682020
10/100
682021
Description
Contents
(Units)
Item Number
Disposable transducer with
Critiflex integral 10/100 682018 flush device Box/Case
and stopcock
(3cc/hr
nominal flow rate)
Disposable transducer for neonatal/paediatric uses, used in conjunction with a mechanical infusion pump (max. 30cc/hr flow rate)
Disposable transducer with Critiflex integral
10/100
682018
transducers
with
integral
flush
device without stopcock (3cc/hr nominal flow rate)
flush Disposable
device and stopcock
(3cc/hr
nominal
flow
rate)
DT-NN
TNF-R
Disposable transducer for neonatal/paediatric uses.
10/100
682019
Disposable
transducer without integral flush device or stopcock, suitable for cardiology/neurology applications
Used in conjunction with a mechanical infusion pump
(max. 30cc/hr flow rate)
DT-XO
Disposable transducers with integral flush
device without stopcock (3cc/hr nominal flow rate)
10/100
682020
TNF-R
Disposable transducer without integral flush device
or stopcock. Suitable for cardiology/neurology applications
10/100
682021
Latex free
CE marked
Class lla
according
the
Sterilisation
method:
Ethyleneto
oxide
Shelf
life:
5
years
Shelf life: 5 years
European Medical Devices
Directive
93/42/EEC
asDevices
amended
by Directive 2007/47/EC
Class IIa according
to European
Medical
Directive
93/42/EEC
Sterilisation method:
Ethylene Oxide
BD
DTX PlusTM Disposable
Pressure Transducer Sets
Designed for ease of use and minimal wavelength distortion
Stand alone Administration Sets
Haemodynamic monitoring information is used to manage the care of critically ill patients. It is therefore essential that you are confident
about the accuracy of the information that you are using. Fluid filled pressure monitoring systems will cause some distortion to the
Box/Case
pressure
waveform. Up to 40% distortion has been shown in some cases.1
Description
Content (Units)
Product
Code
5/25
682209
5/25
682210
5/25
682211
Accuracy in pressure monitoring isn’t just dependent on the transducer, it’s dependent on all the components in the pressure monitoring
system;
catheter,
pressuresettubing,
monitor
filtercannula
and stopcocks.
It has(red)
been shown2 that in order to know the accuracy of your system, you
Single
administration
with 15µ
filter, angled
and roller clamp
need to consider the performance of the total chain where all the components are linked together.
Double administration set with 15µ filter, angled cannula and roller clamps (red/blue)
As a manufacturer we believe we have a responsibility to provide you with information
set the
with 15µ
filter, angled
cannulasystem,
and roller not
clamps
(red/blue/white)
aboutTriple
the administration
accuracy of
whole
monitoring
just
the transducer.
Therefore, BD has selected a range of standard BD DTX PlusTM sets which are Gabarith
tested.2
Latex free
The BD GabarithTM test remains the only scientific technique that provides information
about
dynamic response performance of the total pressure monitoring system
CEthe
marked
(total chain).
PRESSURE OUT
PRESSURE IN
GABARITH
WINDOW OF
TOLERANCE
TM
lla according
the
European
Medical
Devices
Directive
test assessestothe
system
against pre-set
windows
of error (2%,
5%
TheClass
BD Gabarith
and 10% waveform distortion). For example: If the dynamic response of a pressure chain
life:10%
5 years
fallsShelf
within the
Gabarith window then we know the pressure waveform will not be distorted by more than 10%.3
Sterilisation method: Ethylene Oxide
TESTED SET
ACCEPTED
AS WITHIN
GABARITH
WINDOW
TESTED SET
DISCARDED
AS OUTSIDE
GABARITH
WINDOW
1
DYNAMIC
RESPONSE
93/42/EEC as amended by Directive 2007/47/EC
0
10
20
Hz
Example of Radial Artery pressure
10% error Gabarith window
(for adult kit)
Windows of tolerance are based on catheter tip sensor results (the ’gold’ standard) using real patient data.
Every box of BD DTX Plus™ pressure monitoring sets is stamped with the BD GabarithTM symbol. This shows that the set has passed
the BD GabarithTM test and has a known level of accuracy. The BD GabarithTM test exceeds the demands of the AAMI standard
(Association for the Advancement of Medical Instrumentation).
References:
(1) Anesthesiology 53: 498-504, 1980; British Journal of Anaesthesia 1987, 59, 901-912; European Academy of Anaesthesiology - Strasbourg Aug/Sep 1997 (Bender HJ, Billiet E et al).
(2) Billiet E, Colardyn F. (1998) Pressure Measurement Evaluation and Accuracy: The Gabarith Test. Intensive Care Medicine 24:1323-1326
(3) Assuming that the set has been set up and zeroed in accordance with manufacturing instructions
15
Disposable 16/2/05
Pressure
Transducer
3:32 pm Page 16
Pressure Transducer Sets
tical Care catalogue 2005
6
BD GabarithTM Disposable
Argon Gabarith Disposable
Transducer Sets
TM
Transducers Sets
Sterile, single use
Sterile, single use
Disposable
Transducer
Sets for the Sets
Invasivefor
Monitoring
of Haemodynamic
Pressureof
Disposable
Transducer
the Invasive
Monitoring
Number of
Flush/Flow rate
Total
Disposable
(cc/Hr)
Pressure line
No. of disposable
Flush/Flow
Transducers
transducers
Ratelength
cc/Hr (cm)
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
3
3
3
3
1
3
1
3
1
1
1
1
2
1
2
1
3
3
3
3
3
3
3
3
3
Clear
150
Clear
Red
150cm
150
Blue
150
150cm
Blue
3
150
Yellow
150cm
3
175
175
3
3
3
1
150cm
Red
2
150/150
5/50
682004
5/50
682002
5/50
682005
5/50
682006
5/50
682004
5/50
682008
With Argon R.O.S.E.
5/20
682009
5/50
682005
5/50
682010
5/50
682011
5/50
682013
Red
Add-on set to set Blue
no. 682037, -38, -55
with R.O.S.E.
Blue
Yellow
w/ non-shunting stopcock
Red & extension set
Clear
For use with infusion pump
Red/Blue
25cm
Red/Blue
150cm
Red/Blue
150/150
Blue/Yellow
150/150/150
Red/Blue/Yellow
Red
with R.O.S.E.
on blue line
Clear
5/50
682006
Add-on set to set no. 682037, -38, -55
5/50
682008
5/25
682017
With Argon R.O.S.E.
5/20
682009
5/50
682010
5/50
682022
5/50
682025
5/25 strap for arm
682030
Velcro
mount
Blue
with 3rd IV line
for add-on set
5/50
682011
5/25
With MultifloTM 5-way
5/25
682037
682032
5/50
682013
5/25
682041
5/25
682046
150cm
Clear
With non-shunting stopcock and extension set
5/25
682017
160cm small bore
Clear
For use with infusion pump
5/50
682022
5/50
682025
5/25
682030
5/25
682032
3
150/150cm
3
150/150cm
3
Clear
with R.O.S.E.
For use with infusion pump
• BD SafedrawTM, closed loop arterial blood sampling system
2
3
150/150cm
available. (Please refer to next section).
3
682001
Clear
• A range of2 Single, Double and3Triple Disposable Transducer
150/150cm
Sets.
2
5/50
Clear
175cm
• Validation1by unique Gabarith™
30 accuracy test. 35cm small bore
• Adult and Paediatric options.
682001
682002
150
3 150/150
30
With Argon R.O.S.E.
with Multiflo 5-way
3 150/150
Product
Code
5/50
Blue
175cm
Box/Case
Content (Units)
5/50
Clear
150
3
3
with R.O.S.E.
Velcro strap for arm mount
150cm
Box/Case
Item
ContentsAdditionalNumber
(Units) Information
Colour
Clear
35 small bore
3
Red
Haemodynamic Pressure
Additional
Information
Pressure
Line(s)
25
30
3
150cm
150
160 small bore
3
Line Length
150
30
3
Pressure line(s)
colour
Total
Pressure
150/150/150cm
• R.O.S.E (Resonance OverShoot Eliminator) included in
selected sets.
Description
• Individually packed, sterile, non-pyrogenic and
latex-free.
TM
TM
• BD Connecta
Clear Plus sampling and zeroing
For usestopcocks
with infusionwith
pump
on/off snap for confirmation of stopcock positioning.
Red/Blue
With Argon R.O.S.E. on blue line
• Designed straight fluid pathway minimises the risk of bubble
Red/Blue
entrapment and subsequent damping of signal.
Red/Blue
With 3rd IV line for add-on set
• Robust monitor connection prevents water penetration and
Blue/Yellow
offers back
pressure calibration facility.
Red/Blue/Yellow
• Unique
‘Easy Vent’ zeroing deadender minimises risk of
touch contamination.
5/25
682037
5/25
682041
5/25
682046
• Wide range of transducer set configurations covering
neonatal to adult pressure
monitoring
requirements.
• Validation by unique Argon Gabarith accuracy test
• Robust
monitor
connection prevents water penetration and offers back
•• Adult
pressure
sets include
rotating
for easy and
pressure calibration facility
A range
of Single,
Double
and male
Tripleluer
Disposable
Transducer
Sets
Sterilisation method:
trouble-free connection onto the catheter.
• Unique Argon EasyVentTM zeroing deadender minimises risk of touch
• Adult and Paediatric options.
• Ethylene oxide
contamination
TM
TM
How
BD Gabarith™
benefit youclosed loop arterial blood sampling
• Argon
Safedraw sets
andcan
Safedraw-P
Shelf
life:
•
Wide range of transducer set configurations covering neonatal to adult
system options available (please refer to next section)
• Unique Gabarith™ testing of sets, using total
• 5 years
pressure monitoring requirements
• haemodynamic
Argon R.O.S.E.
(Resonance
OverShoot
Eliminator)
included in
chain
concept, offers
the opportunity
for
selected sets
Class IIa according to European
LatexMedical
free Devices Directive
improved haemodynamic accuracy1.
• Individually packed, sterile, non-pyrogenic and latex-free93/42/EEC
CE marked
• Adult pressure sets include rotating male luer for easy and trouble-free
connection onto the catheter
Class lla according to the European Medical Devices
Directive 93/42/EEC as amended by Directive 2007/47/EC
1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: 1323-1326
How Argon GabarithTM Sets can benefit you
• Unique Argon GabarithTM testing of sets, using total haemodynamic
chain concept, offers the opportunity for improved haemodynamic
accuracy1.
• Argon sampling and zeroing stopcocks with on/off snap for
confirmation of stopcock positioning
• Designed straight fluid pathway minimises the risk of bubble
entrapment and subsequent damping of signal
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: 1323-1326
Critical Care Systems
Pressure Transducer Sets
Argon SafedrawTM Safe Arterial Sampling
Disposable Transducer Sets
Sterile, single use
Argon SafedrawTM safe arterial blood sampling systems significantly reduce unnecessary blood discard and blood spillage,
thereby reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. The system’s easy-to-use,
self-sealing, silicone septum facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable
laboratory values.
The SafedrawTM core-resistant septum helps to minimise exposure to pathogens by preventing non-sterile contact with the
fluid path whilst enabling the taking of multiple samples. Unique Argon GabarithTM testing of SafedrawTM sets, using total
haemodynamic chain concept, offers the opportunity for improved haemodynamic accuracy.
Available in Single, Double, Triple and Argon ‘Flexi’ Disposable Transducer configurations, with Adult and Paediatric options,
SafedrawTM systems are individually packed, sterile, non-pyrogenic and latex-free.
No. of
Disposable
Transducers
Flush/
Flow Rate
(cc/Hr)
Total Pressure
Line Length (cm)
Pressure
Line(s)
Colour
Additional Information
Safedraw
Syringe
Volume (cc)
Box/Case
Contents
(Units)
Product
Code
1
3
155cm (125/30)
Clear
Single Admin Set. Single Transducer Set with
Integrated SafedrawTM Septum (Red)
2cc
5/25
682051
2
3
A: 155cm (125/30)
V: 150cm (125/25)
A: Clear
V: Blue
Bifurcated Admin Set. Double Transducer Set with Integrated
SafedrawTM Septum (Red) and R.O.S.E on Venous Line
2cc
5/20
682053
2
3
A: 155cm (125/30)
V: 150cm (125/25)
A: Clear
V: Blue
Bifurcated Admin Set. Double Transducer Set with
Integrated SafedrawTM Septum (Red)
2cc
5/25
682054
2
3
A: 155cm (125/30)
V: 150cm (125/25)
A: Clear
V: Blue
Trifurcated Admin Set. Double Transducer Set with
Integrated SafedrawTM Septum (Red)
2cc
5/20
682055
3
3
A: 155cm (125/30)V:
150cm (125/25)
PA: 150cm (125/25)
A: Clear
V: Blue
PA: Yellow
Trifurcated Admin Set. Triple Transducer Set with
Integrated SafedrawTM Septum (Red)
2cc
5/20
682056
1
3
190cm (160/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated SafedrawTM Septum (Red)
2.5cc
5/25
686337
1
3
190cm (75/85/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated SafedrawTM Septums (Red)
2.5cc
5/20
686585
1
3
190cm (160/30)
Red/Clear
No Admin Set. Single 'Flexi' Add-On Transducer Set with
Integrated SafedrawTM Septum (Red)
2.5cc
5/25
687714
Clear
Single Paediatric Transducer Set with Integrated Safedraw
Septum (Red) For use with Infusion Pump
TM
1cc
5/25
682052
TM
2.5cc
5/25
688077
0.5cc
5/25
687677
1
30 (Paed Set)
135cm (125/10)
1
3 (Paed Set)
135cm (125/10)
Clear
Single Paediatric Transducer Set with Integrated Safedraw
Septum (Red) For use with Infusion Pump
1
3 (Paed Set)
29cm (22/7)
Clear
Single Paediatric Set with Integrated SafedrawTM Septum (Red)
For use with Infusion Pump
Argon SafedrawTM Accessories
Product Description
Model
Box/Case Content (Units)
Product Code
SafedrawTM Vacutainer Transfer Device
TA-STV
25/125
682158
SafedrawTM Luer-Lok Safe-Needle
TA-BPN
50/500
682159
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Critical Care Systems
Pressure Transducer Sets
Argon Safedraw-PTM Safe Arterial Sampling
Disposable Transducer Sets
Sterile, single use
Argon Safedraw-PTM arterial blood sampling systems are a unique range of invasive pressure monitoring sets designed for
closed loop, safe arterial blood sampling procedures.
Whole blood samples are collected via direct luer-slip access into the unique Safedraw-PTM split-septum blood sampling
port, thereby negating the need for blood sampling adapters. The Safedraw-PTM blood sampling port is either integrated
directly into the tubing, or as an integral part of the special three-way sampling stopcock.
Safedraw-PTM safe arterial blood sampling systems significantly reduce unnecessary blood discard and blood spillage, thereby
reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. The system’s direct luer-slip access
design facilitates easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values.
Unique Argon GabarithTM testing of Safedraw-PTM sets, using total haemodynamic chain concept, offers the opportunity for
improved haemodynamic accuracy.
Available in Single, Double, Triple and Argon ‘Flexi’ Disposable Transducer configurations, with Adult and Paediatric options,
Safedraw-PTM systems are individually packed, sterile, non-pyrogenic and latex-free.
See product table on next page.
Argon Safedraw-PTM Accessories
Product Description
Shelf Life
Box/Case Content (Units)
Product Code
Safedraw-PTM Luer-lock Adapter System
5 Years
50/500
688446
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 2 years
Sterilisation method: Ethylene Oxide
Critical Care Systems
Pressure Transducer Sets
Argon Safedraw-PTM Safe Arterial Sampling
Disposable Transducer Sets
Sterile, single use
No. of
Disposable
Transducers
Flush/
Flow Rate
(cc/Hr)
Total Pressure
Line Length (cm)
Pressure
Line(s)
Colour
Additional Information
Safedraw
Syringe
Volume (cc)
Septum Model
Box/Case
Contents
(Units)
Product
Code
1
3
183cm (153/30)
Clear
Single Admin Set. Single Transducer Set with
Integrated Safedraw-PTM Septum (Red)
2cc
1 x Inline
5/20
688413
1
3
213cm (183/30)
Red/Clear
Single Admin Set. Single Transducer Set with Integrated
Safedraw-PTM Septum (Red)
2cc
1 x Inline
5/25
688410
1
3
223cm (133/90)
Red/Clear
Single Admin Set. Single Transducer Set with Integrated
Safedraw-PTM Septum (Red)
3cc
1 x Inline
5/20
688457
1
3
78cm (63/15)
Red/Clear
Single Admin Set. Single Transducer Set with
Integrated Safedraw-PTM Septum (Red) with
Velcro Strap for Arm mounting
1.5cc
1 x Inline
5/20
688538
1
3
A: 213cm (183/30)
V: 150
A: Red/Clear
V: Blue
Single Admin Set. Single Transducer Set with non-shunting
stopcock and Integrated Safedraw-PTM Septum (Red) (with
Separately Packaged 150cm Blue pressure line)
2.5cc
1 x Inline
5/25
688403
1
3
A: 183cm (153/30)
V: 125
A: Red/Clear
V: Blue
Single Admin Set. Single Transducer Set with R.O.S.E.,
non-shunting stopcock, and Integrated Safedraw-PTM Septum
(Red) (with Separately Packaged 125cm Blue pressure line)
2cc
1 x Inline
5/20
688407
1
3
A: 193cm (163/30)
V: 150
A: Red/Clear
V: Blue
Single Admin Set. Single Transducer Set with
non-shunting stopcock (with 150cm Blue pressure line) and
Integrated Safedraw-PTM Septum (Red)
2.5cc
1 x Inline
5/20
688496
2
3
A: 183cm (153/30)
V: 150cm (125/25)
A: Clear
V: Blue
Bifurcated Admin Set. Double Transducer Set with
Integrated Safedraw-PTM Septum (Red)
2cc
1 x Inline
5/20
688416
2
3
A: 213cm (183/30)
V: 186cm (183/3)
A: Red/Clear
V: Blue/Clear
Bifurcated Admin Set. Double Transducer Set with Integrated
Safedraw-PTM Septum (Red) and Integrated Safedraw-PTM
Stopcock Septum (Blue)
2.5cc
1 x Inline (Red)
1 x Stopcock (Blue)
5/25
688401
2
3
A: 223cm (133/90)
V: 216cm (183/33)
A: Red/Clear
V: Blue/Clear
Bifurcated Admin Set. Double Transducer Set with Integrated
Safedraw-PTM Septum (Red) and Integrated Safedraw-PTM
Stopcock Septum (Blue)
3cc
1 x Inline (Red)
1 x Stopcock (Blue)
5/25
688604
2
3
A: 223cm (133/90)
V: 90cm
A: Red/Clear
V: Blue
Trifurcated Admin Set. Double Transducer Set with Integrated
Safedraw-PTM Septum (Red) and Integrated Stopcock (Blue)
3cc
1 x Inline (Red)
5/20
688452
2
3
A: 223cm (133/90)
V: 211cm (183/28)
A: Red/Clear
V: Blue/Clear
Trifurcated Admin Set. Double Transducer Set with Integrated
Safedraw-PTM Septum (Red) and Integrated Safedraw-PTM
Stopcock Septum (Blue)
3.5cc
1 x Inline (Red)
1 x Stopcock (Blue)
5/20
688528
2
3
A: 233cm (143/90)
V: 205cm (180/25)
A: Red/Clear
V: Blue/Clear
Trifurcated Admin Set. Double Transducer Set with
Integrated Safedraw-PTM Septum (Red) and
2 x Sampling Stopcocks (Blue)
3cc
1 x Inline (Red)
5/20
688572
3
3
A: 213cm (183/30)
V: 126cm (123/3)
PA: 120cm
A: Red/Clear
V: Blue/Clear
PA: Yellow
Trifurcated Admin Set. Triple Transducer Set with Integrated
Safedraw-PTM Septum (Red) and Integrated Safedraw-PTM
Stopcock Septum (Blue)
3cc
1 x Inline (Red)
1 x Stopcock (Blue)
5/20
688481
1
3
193cm (163/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
non-shunting stopcock and
Integrated Safedraw-PTM Septum (Red)
2.5cc
1 x Inline
5/20
688396
1
3
193cm (163/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated Safedraw-PTM Stopcock Septum (Red)
3cc
1 x Stopcock
5/20
688389
1
3
213cm (183/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated Safedraw-PTM Septum (Red)
2.5cc
1 x Inline
5/25
688420
1
3
203cm (53/120/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated Safedraw-PTM Septums (Red)
2.5cc
2 x Inline
5/20
688406
1
3
193cm (73/90/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated Safedraw-PTM Stopcock Septums (Red)
3cc
2 x Stopcock
5/25
688513
1
3 (Paed Set)
143cm (128/15)
Clear
Single Paediatric Transducer Set with Integrated
Safedraw-PTM Septum (Red) For use with Infusion Pump
2.5cc
1 x Inline
5/25
688408
1
3 (Paed Set)
158cm (153/5)
Clear
Single Paediatric Transducer Set with Integrated
Safedraw-PTM Septum (Red) For use with Infusion Pump
2cc
1 x Inline
5/25
688550
1
30 (Paed Set)
158cm (153/5)
Clear
Single Paediatric Transducer Set with Integrated
Safedraw-PTM Septum (Red) For use with Infusion Pump
2cc
1 x Inline
5/25
688600
Critical Care Systems
Pressure Transducer Sets
Argon DTX PlusTM Paediatric and Neonatal
Disposable Transducer Sets
Sterile, single use
Argon DTX PlusTM Paediatric and Neonatal Transducer Systems are a range of ‘Standard’ and ‘Closed loop’ SafedrawTM and
Safedraw-PTM safe arterial blood sampling invasive pressure monitoring sets specifically designed with the Paediatric and
Neonatal patient in mind. Whole blood samples are collected in the ‘closed-loop’ SafedrawTM and Safedraw-PTM sets either
via the SafedrawTM self-sealing silicone septum or via direct luer-slip access into the unique Safedraw-PTM split-septum
blood sampling port. SafedrawTM and Safedraw-PTM safe arterial blood sampling systems significantly reduce unnecessary
blood discard and facilitate the safe return of diluted blood back to the infant, thereby safely conserving blood volume whilst
reducing the risk of iatrogenic anaemia and cross contamination. The system’s design facilitates easier blood sampling and
superior clinical samples, thereby achieving more reliable laboratory values.
Unique Argon GabarithTM testing of these Paediatric and Neonatal sets, using total haemodynamic chain concept, offers the
opportunity for improved haemodynamic accuracy. Configured for use with an Infusion Pump, Argon DTX PlusTM Paediatric
and Neonatal Transducer Systems are individually packed, sterile, non-pyrogenic and latex-free.
No. of
Disposable
Transducers
Flush/
Flow Rate
(cc/Hr)
Total Pressure
Line Length (cm)
Pressure
Line(s)
Colour
Additional Information
Safedraw
Syringe
Volume (cc)
Septum Model
Box/Case
Contents
(Units)
Product
Code
1
30 (Paed Set)
160cm (150/10)
Clear
Single Paediatric Transducer Set
For use with Infusion Pump
N/A
N/A
5/50
682022
1
30 (Paed Set)
35cm (25/10)
Clear
Single Paediatric Transducer Set
For use with Infusion Pump
N/A
N/A
5/50
682025
1
30 (Paed Set)
135cm (125/10)
Clear
Single Paediatric Transducer Set
with Integrated SafedrawTM Septum (Red)
For use with Infusion Pump
1cc
SafedrawTM
1 x Inline
5/25
682052
1
3 (Paed Set)
135cm (125/10)
Clear
Single Paediatric Transducer Set with
Integrated SafedrawTM Septum (Red)
For use with Infusion Pump
2.5cc
SafedrawTM
1 x Inline
5/25
688077
1
3 (Paed Set)
29cm (22/7)
Clear
Single Paediatric Set with
Integrated SafedrawTM Septum (Red)
For use with Infusion Pump
0.5cc
SafedrawTM
1 x Inline
5/25
687677
1
3 (Paed Set)
143cm (128/15)
Clear
Single Paediatric Transducer Set with
Integrated Safedraw-PTM Septum (Red)
For use with Infusion Pump
2.5cc
Safedraw-PTM
1 x Inline
5/25
688408
1
3 (Paed Set)
158cm (153/5)
Clear
Single Paediatric Transducer Set with
Integrated Safedraw-PTM Septum (Red)
For use with Infusion Pump
2cc
Safedraw-PTM
1 x Inline
5/25
688550
1
30 (Paed Set)
158cm (153/5)
Clear
Single Paediatric Transducer Set with
Integrated Safedraw-PTM Septum (Red)
For use with Infusion Pump
2cc
Safedraw-PTM
1 x Inline
5/25
688600
Argon SafedrawTM and Safedraw-PTM Accessories
Product Description
Shelf life
Box/Case Content (Units)
Product Code
Safedraw-PTM Luer-lock Adapter System
5 Years
50/500
688446
Safedraw Vacutainer Transfer Device (TA-STV)
5 Years
25/125
682158
SafedrawTM Luer-Lok Safe-Needle (TA-BPN)
5 Years
50/500
682159
TM
Latex free & CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (for Standard and SafedrawTM sets)
2 years (for Safedraw-PTM sets)
Sterilisation method: Ethylene Oxide
Critical Care Systems
Pressure Transducer Sets
Argon DTX PlusTM Flexi Disposable
Transducer Sets
Sterile, single use
Argon DTX PlusTM Flexi Transducer Systems are a range of invasive pressure monitoring sets designed to improve
Procurement stocking efficiency through facilitating appropriate set configuration selection whilst minimising unused set
component wastage. In the Flexi configuration the Arterial disposable transducer system is used as the ‘master’ line.
When clinically required, additional lines are connected to this ‘master’ line in a cascade. This is achieved via an additional
stopcock positioned on the administration set side of the transducer, thereby having no impact on dynamic response.
This innovative Flexi solution, offering the adaptability of single, or multiple transducer set configurations, facilitates set
selection, set-up time whilst minimising storage costs.
Available in Standard set format, SafedrawTM or Safedraw-PTM Closed-loop, arterial blood sampling formats, Argon DTX
PlusTM Flexi Transducer Systems are individually packed, sterile, non-pyrogenic and latex-free.
Additional Information
Safedraw
Syringe
Volume (cc)
Septum Model
Box/Case
Contents
(Units)
Product
Code
Red
Single Admin Set. Single 'Flexi' Arterial Transducer Set
N/A
N/A
5/25
686562
Blue
No Admin Set. Single 'Flexi' Add-On Venous Transducer Set
N/A
N/A
5/25
686495
Yellow
No Admin Set. Single 'Flexi' Add-On PA Transducer Set
N/A
N/A
5/25
686496
175cm (160/15))
Clear
No Admin Set. Single 'Flexi' Add-On Universal Transducer Set
N/A
N/A
5/25
686572
175cm (160/15)
Blue
Single Admin Set. Single 'Flexi' Venous Transducer Set
N/A
N/A
5/25
687715
2.5cc
SafedrawTM
1 x In-Line
5/25
686337
No. of
Disposable
Transducers
Flush/
Flow Rate
(cc/Hr)
Total Pressure
Line Length (cm)
1
3
175cm (150/25)
1
3
175cm (160/15)
1
3
175cm (175)
1
3
1
3
Pressure
Line(s)
Colour
1
3
190cm (160/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated SafedrawTM Septum (Red)
1
3
190cm (75/85/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated SafedrawTM Septums (Red)
2.5cc
SafedrawTM
2 x In-Line
5/20
686585
1
3
190cm (160/30)
Red/Clear
No Admin Set. Single 'Flexi' Add-On Transducer Set with
Integrated SafedrawTM Septum (Red)
2.5cc
SafedrawTM
1 x In-Line
5/25
687714
1
3
193cm (163/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with nonshunting stopcock and Integrated Safedraw-PTM Septum (Red)
2.5cc
Safedraw-PTM
1 x In-Line
5/20
688396
1
3
193cm (163/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated Safedraw-PTM Stopcock Septum (Red)
3cc
Safedraw-PTM
1 x Stopcock
5/20
688389
1
3
213cm (183/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
Integrated Safedraw-PTM Septum (Red)
2.5cc
Safedraw-PTM
1 x In-Line
5/25
688420
1
3
203cm (53/120/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated Safedraw-PTM Septums (Red)
2.5cc
Safedraw-PTM
2 x In-Line
5/20
688406
1
3
193cm (73/90/30)
Red/Clear
Single Admin Set. Single 'Flexi' Transducer Set with
2 x Integrated Safedraw-PTM Stopcock Septums (Red)
3cc
Safedraw-PTM
2 x Stopcock
5/25
688513
Argon Flexi SafedrawTM and Safedraw-PTM Accessories
Product Description
Shelf life
Box/Case Content (Units)
Product Code
Safedraw-PTM Luer-lock Adapter System
5 Years
50/500
688446
Safedraw Vacutainer Transfer Device (TA-STV)
5 Years
25/125
682158
SafedrawTM Luer-Lok Safe-Needle (TA-BPN)
5 Years
50/500
682159
TM
Latex free & CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (for Standard and SafedrawTM sets)
2 years (for Safedraw-PTM sets)
Sterilisation method: Ethylene Oxide
Critical Care Systems
Pressure Transducer Sets
Argon RT2000 Reusable Transducer and
Disposable Domes and Dome systems
Sterile, single use
Argon RT2000 Reusable Transducer and Disposable Domes and Dome Systems are engineered to improve cost efficiencies
by reducing disposal costs and biological wastage generation whilst maintaining pressure waveform accuracy and
reliability.
With the Argon RT2000 system only the sterile disposable dome components are discarded after each patient use whilst
the reusable RT2000 transducer is retained ready for the next patient’s use. This enables the cost per patient set-up to be
lower than fully disposable transducer systems and minimises environmental impact by reducing the volume of hazardous
waste generated per patient.
The one-handed ‘snap-on’ dry coupling system for engagement of the disposable sterile dome set with the Argon RT2000
reusable transducer system is simple and quick to perform, thereby minimising initial set-up time. The straight and visible
fluid pathway enables the disposable dome to fill, bubble-free with minimal effort. The integrated flush device and venting
EasyVent zeroing stopcock provide quick, effective fluid control.
Argon RT2000 systems are available in Flexi format and with the SafedrawTM and Safedraw-PTM safe arterial blood sampling
systems. These systems are designed to significantly reduce unnecessary blood discard and blood spillage, thereby
reducing the risk of iatrogenic anaemia and cross contamination to patients and staff. Whole blood samples are collected
in the ‘closed-loop’ SafedrawTM and Safedraw-PTM sets either via the SafedrawTM self-sealing silicone septum or via direct
luer-slip access into the unique Safedraw-PTM split-septum blood sampling port. The ‘closed-loop’ system design facilitates
easier blood sampling and superior clinical samples, thereby achieving more reliable laboratory values.
Available in Argon Standard and ‘Flexi’ Disposable Dome configurations, with Adult SafedrawTM and Safedraw-PTM options,
Argon RT2000 Dome systems are individually packed, sterile, non-pyrogenic and latex-free.
See product table on next page.
Argon RT2000 Reusable Transducer Specifications
Detail
Argon RT2000 Transducer specifications
Operating pressure:
-30 to 300 mmHg
Overpressure withstand
5,170 mmHg
Nominal sensitivity (gain):
5 µV/V/mmHg
Linearity:
±1% over 0-50 mmHg
Hysteresis:
±3% over 50-300 mmHg
Unbalance (zero balance):
+40 mmHg
Thermal coefficient of sensitivity (typical):
±1% / ºC
Thermal coefficient of zero (typical):
±3% mmHg / ºC
Leakage:
<5µA at 220V 50Hz
Defibrillator withstand:
Withstand five repeated discharges in 5 minutes of 400J sinusoidal energy delivered into 50 ohms when all
transducer wires are shorted and saline is in fluid column
Maximum Excitation Voltage:
10V DC or AC
Critical Care Systems
Pressure Transducer Sets
Argon RT2000 Reusable Transducer and
Disposable Domes and Dome systems
Sterile, single use
No. of
Disposable
Domes
Flush/
Flow Rate
(cc/Hr)
Total Pressure
Line Length (cm)
Pressure
Line(s)
Colour
Additional Information
Safedraw
Syringe
Volume (cc)
Model
Box/Case
Contents
(Units)
Product
Code
N/A
N/A
N/A
N/A
Argon RT2000 reusable pressure transducer
N/A
RT2000
10/100
682266
N/A
DD2003
10/100
682263
1
3
N/A
N/A
RT2000 Disposable dome with integral flow/flush device
(3cc/hr nominal flow rate) and Zeroing Stopcock
1
N/A
N/A
N/A
RT2000 Disposable dome without integral flow/flush device
or Zeroing Stopcock
N/A
DD2000
10/100
682265
1
3
175cm (150/25)
Clear
Single Admin Set.
Single RT2000 'Universal' Dome Set
N/A
N/A
5/25
686958
1
3
175cm (150/25)
Red
Single Admin Set. Single 'Flexi' RT2000 Arterial Dome Set
with non-shunting stopcock
N/A
N/A
5/20
687886
1
3
175cm (150/25)
A: Red
V: Blue
Single Admin Set. Single 'Flexi' RT2000 Arterial Dome Set
with non-shunting stopcock (with Separately Packaged
150cm Blue pressure line)
N/A
N/A
5/20
686961
1
3
175cm (160/15)
Blue
No Admin Set.
Single 'Flexi' RT2000 Add-On Venous Dome Set
N/A
N/A
5/25
687887
1
3
175cm (175)
Yellow
No Admin Set.
Single 'Flexi' RT2000 Add-On PA Dome Set
N/A
N/A
5/25
687888
1
3
193cm (163/30)
Red/Clear
Single Admin Set. Single 'Flexi' RT2000 Arterial
Dome Set with non-shunting stopcock and
Integrated Safedraw-PTM Septum (Red)
2.5cc
Safedraw-PTM
1 x Inline
5/20
688397
1
3
A: 180cm (150/30)
V: 150
A: Red/Clear
V: Blue
Single Admin Set. Single RT2000 Arterial Dome Set with
non-shunting stopcock (with 150cm Blue pressure line) and
Integrated Safedraw-PTM Septum (Red)
2.5cc
Safedraw-PTM
1 x Inline
5/20
688546
Argon RT2000 SafedrawTM and Safedraw-PTM Accessories
Product Description
Shelf life
Box/Case Content (Units)
Product Code
Safedraw-PTM Luer-lock Adapter System
5 Years
50/500
688446
SafedrawTM Vacutainer Transfer Device (TA-STV)
5 Years
25/125
682158
Safedraw Luer-Lok Safe-Needle (TA-BPN)
5 Years
50/500
682159
TM
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years (for Standard and SafedrawTM sets)
2 years (for Safedraw-PTM sets)
Sterilisation method: Ethylene Oxide
Note: RT2000 Reusable Transducer Unit is provided non-sterile and with one year’s manufacturer’s warranty
Critical Care Systems
Pressure Transducer Sets
Catheter
Lab Set
Argon Cardiac Catheterisation
Laboratory DTX PlusTM Transducer
Set Configurations
Sterile, single use
Contrast
Saver Set
Argon Cardiac Catheterisation Laboratory DTX PlusTM Transducer Set Configurations
With a choice of high quality pressure monitoring and fluid management components to choose from, Argon’s range of
Cardiac Cath Lab Transducer sets are designed to meet the challenges and requirements of your cardiac catheterisation
laboratory.
Where accurate pressure readings are vital, Argon’s long history in pressure monitoring and transducer development, dating
back to the first reusable transducer in 1946, has resulted in the Argon DTX PlusTM transducer set options.
With ease of priming and de-bubbling, with ‘standard’ and 106cm (42’’) cable option and a choice of flush and no-flush
versions, the Argon DTX PlusTM transducer sets facilitate accurate pressure monitoring within the Cath Lab environment.
Argon high pressure manifolds are supplied with a choice of ‘Open’ or ‘Finger grip’ (Block) design, 2, 3 or 4 ports, and
having either ‘Left’ or ‘Right’ rotating adapter to best meet specific procedural needs and physician preferences.
Manifolds designed with tight tolerances, low torque and smooth port rotation and manifold Distal Rotating Adapter facilitates
easy catheter manipulation. Choice of ‘Open’ or ‘Block’ body design and clear polycarbonate body for easy bubble visualisation,
the manifolds construction will withstand injections and are rated at 500 psi.
Available in clear, semi-rigid PVC and Flexible Braided Polyurethane with or without Rotating Adapter, Argon High Pressure
Injection Lines are designed to provide optimal flexibility, easy debubbling and secure connections and are rated up to
1200 psi.
Argon Control Syringes are available with choice of ‘Thumb Ring’ or ‘Palm Pad’ design, ‘Finger Ring’ vs ‘Finger Grip’, and
10cc vs 12cc volume options to best suit most Clinical Needs and hand sizes. Control syringe low friction plunger provides
for a smooth injection, bold volume markings facilitate accurate volume injections, whilst the clear polycarbonate body
provides a sturdy syringe able to withstand any hand pressure whilst facilitating for easy bubble visualisation. 10cc or 12cc
volume options for larger handed use.
Choice of syringe Palm Pad designs, including ‘soft touch’ options, allows for full force palm injections and thumb ring
design facilitates aspirations and injections whilst choice of finger grip or ring style to meet most clinical needs.
Contrast Saver Administration set options available to reduce Contrast wastage and reduce risk of air entering the system.
Argo-BagzTM 1,500ml PVC bag Waste Management System options, High Pressure stopcocks (850 psi rated) and other
componentry also available to enhance kit functionality. Argon Cardiac Catheterisation Laboratory DTX PlusTM Transducer
Set Configurations are available as ‘Off-the-shelf’ options. (Other Cath Lab configurations and Custom kit configuration
options are available on request.)
See product table on next page.
Critical Care Systems
Pressure Transducer Sets
Catheter
Lab Set
Argon Cardiac Catheterisation
Laboratory DTX PlusTM Transducer
Set Configurations
Sterile, single use
Contrast
Saver Set
Flush/
Flow Rate
(cc/Hr)
Manifold
Pressure Line(s)
Colour
Additional Information
Check Valves
Contrast Syringe
Box/Case
Contents
(Units)
Product
Code
DTX PlusTM TNF-R
with 106cm
transducer cable
No Flush
3-way, 360°
'off-directed', right
orientated, block
body, Rotating
Adapter
25cm
High Pressure
braided
Argon Cath Lab set with DTX PlusTM TNF-R transducer,
3-way 'off-directed' right orientated manifold with 25cm
High pressure braided tubing, administration set (15
micron filter), Dual Check Valve and 12ml Contrast Syringe. (For use with Contrast Saver set P/N: 688758)
1 x Dual
Check Valve
12ml with thumb/
finger rings and
rotating adapter
5/20
688759
N/A
N/A
N/A
N/A
Argon Contrast Saver Kit with 30ml burette and white
stopcock. (For use with DTX PlusTM Manifold Cath Lab Kits)
N/A
N/A
5/25
688758
3cc/hr
2-way
'on-directed', right
orientated, block
body, Rotating
Adapter
75cm Clear
Argon Cath Lab set with DTX PlusTM DT-XX pressure
transducer, 75cm Clear pressure line, 2-way 'on-directed'
right orientated manifold with Contrast administration set
(200 micron filter), 12ml Contrast Syringe and
administration set (15 micron filter).
N/A
12ml with thumb/
finger rings and
rotating adapter
5/20
686331
150cm Red
Argon Cath Lab set with DTX PlusTM DT-XX pressure
transducer with administration set (15 micron filter),
150cm Red pressure line, stopcock and High Pressure
Rotating Adapter. (FOR PAEDIATRIC
CATHETERISATION PROCEDURES)
N/A
N/A
5/25
686549
150cm Clear
Argon Cath Lab set with Dual Check Valve, 2-way
'off-directed' right orientated manifold with 2 x Contrast
administration sets (200 micron filter), 150cm Clear
pressure tubing and 10ml Contrast Syringe. Separately
packaged DTX PlusTM TNF-R transducer with tap and
ROSE (Resonance OverShoot Device).
1 x Dual
Check Valve
10ml with thumb
ring/finger grips
and 0.5ml
'stop' ring
5/20
686132
25cm, 30cm
and 75cm Clear
Argon Cath Lab set with DTX PlusTM DT-XX pressure
transducer with administration set (15 micron filter), 75cm
Clear pressure line, High Presssure stopcock with 30cm
Clear pressure line and 25cm Clear pressure line and
High Pressure Rotating Adapter
N/A
N/A
5/25
686237
150cm Clear
Argon Cath Lab set with DTX PlusTM DT-XX pressure
transducer with administration set (15 micron filter),
150cm Clear pressure line and 2-way 'on-directed' right
orientated manifold.
N/A
N/A
5/25
688744
130cm Clear,
120cm High
Pressure
Argon Cath Lab set with DTX PlusTM TNF-R transducer
with tap, 130cm Clear pressure tubing, 3-way 'ondirected' right orientated manifold with administration set
(15 micron filter) with tap, 120cm High Pressure tubing
and 12ml Contrast Syringe. (For use with Contrast Saver
set P/N: 688758)
N/A
12ml with thumb/
finger rings and
rotating adapter
5/20
688709
130cm Clear
Argon Cath Lab set with DTX PlusTM TNF-R pressure
transducer with 3 way stopcock, 130cm Clear pressure
line, 2 x 3 way stopcocks and administration set (15
micron filter).
N/A
N/A
5/25
688143
10ml with thumb
ring/finger grips
5/20
687699
Disposable
Transducer Model
DTX Plus DT-XX
TM
DTX Plus DT-XX
TM
DTX PlusTM TNF-R
DTX PlusTM DT-XX
DTX Plus DT-XX
TM
DTX PlusTM TNF-R
DTX Plus TNF-R
TM
DTX PlusTM DT-XX
3cc/hr
N/A
No Flush
2-way 360°
'off-directed', right
orientated, block
body, Rotating
Adapter
3cc/hr
N/A
3cc/hr
2-way 'on-directed',
right orientated,
block body,
Rotating Adapter
No Flush
3-way
'on-directed', right
orientated, block
body, Rotating
Adapter
No Flush
3cc/hr
N/A
N/A
100cm Clear
Argon Cath Lab set with 10ml Contrast Syringe. Separately packaged DTX PlusTM DT-XX pressure transducer
with administration set (15 micron filter), 100cm Clear
1 x Dual
pressure line, 3 way stopcock with High Pressure Rotator Check Valve
Adapter and Dual Check Valve with
contrast administration set (15 micron filter).
Latex free
CE marked
Class lla according to the European Medical Devices Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: Dependent on kit contents
Sterilisation method: Ethylene Oxide
Lines and Pressure Accessories
Argon Pressure Lines & Pressure Accessories
Sterile, single use
Male/Female or
Male/Male Line Connection
Tubing Length
Line Colour Coding
Box/Case
Content (Units)
Priming
Volume (cm3)
Inner (mm)
Outer (mm)
Tube Diameter
Product Code
ARGON PRESSURE LINES (PVC)
M/F
25cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682226
M/F
100cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682229
M/F
150cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682230
M/F
200cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682232
M/M
100cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682234
M/M
150cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682079
M/M
200cm
Clear
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682236
M/F
100cm
Red
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
682237
M/F
150cm
Red
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
685185
M/M
125cm
Blue
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
685190
M/M
150cm
Blue
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
685171
M/F
150cm
Yellow
25/125
0.019
1.575 (± 0.076)
3.175 (± 0.051)
686619
ARGON PE PRESSURE MONITORING LINES (PolyEthylene)
M/F
15cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682194
M/F
50cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682185
M/F
100cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682189
M/F
150cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682191
M/F
200cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682192
M/M
50cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682186
M/M
100cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682190
M/M
200cm
Clear (Red/Blue Stickers)
25/250
0.011
1.20 (± 0.05)
2.50 (+ 0.1/- 0.05)
682193
Description
Latex free
• Argon Pressure Lines (PVC) for accurate transmission of the pressure
waveform
• PVC Pressure Lines maximum pressure tolerance (fluid filled) 200 psi.
• Argon PE (PolyEthylene) lines as a non PVC alternative
• Colour coded stickers supplied with Argon PE to facilitate line
identification
• PE Pressure Lines maximum pressure tolerance (fluid filled) 43 psi.
CE marked
Class lla according to the European Medical Devices
Directive 93/42/EEC as amended by Directive 2007/47/EC
Shelf life: 5 years
Sterilisation method: Ethylene Oxide
Description
Box/Case
Content (Units)
Product
Code
Transducer BackGround for pole mounting (up to 4 transducers)
10/100
682093
Model
PRESSURE ACCESSORIES (Non-Sterile)
TBG
TMM
TMM/TBG
Cable Checker
UMM
Snap-On TMM Cable Organiser
5/50
682274
TBG with Snap-On TMM Cable Organiser (P/Ns 682093, 682274)
5/50
682275
Transducer tester for monitor calibration
1
684003
Universal Manifold Mount
5/50
682104
Pressure Transducer Sets
cal Care catalogue 2005
16/2/05
3:32 pm
Page 20
BD
Transducer
Interface
Argon
Transducer
Interface Cables
Cables
Argon supply compatible interface cables for the majority
• Non-sterile items
ofsupply
currently
available
pressure
monitors.
•Below
When purchasing cables
please specify:–
• BD
compatible
interfaceblood
cables for
the majority
of
• Latex
free
Monitor
currently
available
monitors.
are listed
theblood
mostpressure
common
interface cables for 1.
use
withtype.
• CE
2. Model number and/or
serialmarked
number.
Argon’s
transducers.
If your
requirements
• Below
is listed
the most common
interface
cables for use are not listed
please
contact your
Argonareoffice
for assistance.
• Class I according to European Medical Devices
• Non-sterile items.
with
BD’s transducers.
If yourlocal
requirements
not listed
Directive
93/42/EEC
please
contact
your
local
BD
office
for
assistance.
Class
I
according
to
European
Medical Devices
Directive as amended by Directive
When purchasing cables please specify:–
1. Monitor type.
2. Model number and/or serial number.
Monitor
Monitor
No Monitor connection
Brucker
CriticareNo Monitor Connection
CriticonCriticon / GE Marquette
Datascope
Datascope
Datex Ohmeda
(GE)/ Mindray
Dräger/Siemens
Dräger
Dräger/Siemens
Dräger / Siemens
Dräger/Siemens
Dräger/Siemens
Dräger / Siemens
Dräger/Siemens
Dräger / Siemens
E For M
Hellige E
(Litton)
for M
Jostra
GE / Datex Ohmeda
Kontron, Arrow
Marquette (GE)
GE / Marquette
Marquette (GE)
MedicalJostra
Measurement Systems
Medical Measurement Systems
Kontron, Arrow
Mennen
Nellcor Marquette (GE)
Nihon Kohden
Mindray
Nihon Kohden
Philips Mindray
Phillips (Hewlett Packard)
Nellcor
Physiocontrol/Medtronic
Nihon Kohden
Physiogard
PPG Biomedical
/ Hellige / Marquette
Nihon Kohden
Protocol Propaq
PRUCKA
ENG INC
Philips
Quinton
Schwarzer
Physiocontrol/Medtronic
Spacelabs
Protocol
Propaq
Spacelabs
Spacelabs (Vitatek) / BCI
Prucka Eng. Inc.
StockertSpacelabs
Stockert
Spacelabs (Vitatek) / BCI
Tektronics
Vitalert
Stöckert (Sorin)
Vitatek
Zoll
Stöckert (Sorin)
Tektronics
Model
93/42/EEC
2007/47/EC
Item Number
Model
(Flying Leads)
684109
TM910M
684230
(Flying
Leads)
Red: - Excitation
MATRIX,
Scholar
2200Shield: Dependent on Monitor. Black: + Signal; White: - Signal. Green: + Excitation;
684175
Dynamap
684085
Dynamap
All Models
684078
All Models
(Passport,
Accutorr, CS100/CS300 IABP)
SYS 800,
MOD 8641,
SIVA 3000
684104
3rd Generation, 400 Series, 960, 961, Sirecust 4041, 700,1260, 342, 732, 342, 4XX, 7XX, 9XX, 12XX,
684082
PM8040, PM8060, Dräger Cato, Cicero & Julian Anes. Machine, Vitara
Delta (SC7000), Kappa (SC8000), Delta XL (SC9000), with 10 pin connector
Siereg/Sicor
BPA 863
(15-pole
Cannon 4041,
Connector),
Mingograph
6, Cathor,
Recor
684121 Infinity Delta, Infinity Kappa,
400 Series,
960,
961, Sirecust
700, 1260,
342, 732,
SC7000,
SC8000), SC9000), Infinity Gamma,
PM8040,
PM8060,
Dräger
& Julian Anes. machine, Vitara
684128
Infinity
Vista all
with Cato,
10 pinCicero
connector
6004, SC6002XL, SC6802XL, SC 6000P, 6002, 5000, Delta (SC7000), Kappa (SC8000),
684178
6002,
5000,
7000,
Infinity monitor,
Gamma,allInfinity
Infinity Kappa, Infinity Vista all with 7 pin connector
Delta SC6000P,
XL (SC9000),
Gamma
XL6004,
(SC6000)
transport
with 7Delta,
pin connector
HemoPod adapter
684236
Hemo Pod Adapter (One adapter for each Hemo2 Pod and two for each Hemo4/HemoMed Pod)
RM300 (E for M/Honeywell)
684128
4th/5th
Generation
SMC 108 / Servomed / SMU 610, 611.612, SMU EVO
684086
RM300
(E for/ M/Honeywell)
684138
GE Monitor with Datex-Ohmeda ‘front end’: SYS 800, MOD 8641, SIVA 3000, Cardiocap, Cardiocap II, AS3, S5, Aestiva, ADU(S5) and Aisys
Minimon 7131 etc, 7132 etc, K2000, 7272 / Supermon 7210 / Cart 2 Plus Balloon Pump, Oxford ACAT1 684129
7000 GE
series,
7010 Mod
7200
684096
Monitor
with Marquette
‘front end’: 7009 / Tramscope Series(600SL) - Eagle-Solar 8000, Solar
9000, Eagle3000/1000, Mab Lab 6Fx3F,
7009 Tram
/ Tramscope
- Eagle-Solar
9000,
Mab Lab 6Fx3F,
684102
450SL,Series(600SL)
6200, Tram600A,
EK36,8000,
DashSolar
3000,
DashEagle3000/1000,
4000, Dash 5000
Tram 450SL, 6200, Tram600A, EK36, Dash 3000, Dash 4000
UPS-2020 (4ft cable)
684204
UPS-2020 (12ft cable)
684242
Minimon 7131 etc., 7132 etc., K2000, 7272 / Supermon 7210 / Cart 2 Plus Balloon Pump, Oxford ACAT1
Envoy
684248
Series, 7010 Mod 7200
Escort7000
300 MDE
684085
MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14,BSM-8300J/K, 3000, BSM4100
684090
PM8000, PM7000, PM9000, Spectrum; MEC Series; Passport/Spectrum
NK9000
JP-900P
CM140
684128
BeneView T5, T8, T1; IPM (8, 10, 12); BeneHeart D6
78341A, 78342A, etc. / 78354C, 78205A-D, 12-pin / 78352, CMS (Merlin line), M1006A/B,
684081
Escort
300 MDE
M1026A
/ M1166A
/ Viridia / HP Scop Eurelie 24C, CMS2001, V24, V26, M2, M3, M4, Intelivue
Lifepack 12 (6 pin)
684085
MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14,BSM-8300J/K, 3000, BSM4100
Physiogard
684230
MIDAS;
Hellige Midas 5000, 2500, 2100 series
684167
NK9000
Protocol Propaq series; Propaq 106EL;
684085
78341A,
/ M1166A / Viridia / HP Scop Eurelie
CARDIOLAB
II / 78342A,
1.1, AMPetc.
II / 78354C, 78205A-D, 12-pin / 78352, CMS (Merlin line), M1006A/B, M1026A
684181
CMS2001, V24, V26, M2, M3, M4, Intelivue
Q-cath24C,
lab system
684134
MX960
684175
Lifepack 12 (6 pin)
Alpha 700 Series
684084
Protocol
Propaq
series;
Propaq
106EL
Series 400, 500, 90308/11/31, MOD-CD
684085
400, 500, 90485, Alpha-PC, 90603A,BCI 9100,90303B-Mod90470-05, CD-CV, 90369, 90385,
684227
Cardiolab II / 1.1, AMP II
90470, 90496, Ultraview 1600
S3 Series 400, 500, 90308/11/31, MOD-CD
684188
Heart Lung Machine
684243
400,
500,
90485,
Alpha-PC,
90603A,
BCI
9100,
90303B-Mod90470-05,
CD-CV,
90369,
90385,
90470,
400 Series
68408590496, Ultraview 1600
2000
684085
S3 / S5
Series 400, 500
684085
Zoll Defribrillators
684085
Heart Lung Machine
400 Series
Product Code
684109
684085
684078
684128
684082
684178
684236
684128
684104
684102
684138
684129
684096
684085
684081
684085
684090
JP-900P
684081
684230
684085
684181
684045
684227
684188
684243
684085
Vitalert
2000
684085
Vitatek
Series 400, 500
684085
Welch Allyn
1500
684085
Zoll
Zoll Defibrillators
684085
Pressure Transducer Sets
684078 - 6 Pin F - LF
684085 – 6 Pin M - LF
Datascope/Mindray – All Models
Passport, Accutorr, CS100/CS300 IABP
Criticon/GE Marquette – Dynamap
Mindray - PM/MEC Series, Spectrum
Nellcor - Escort 300 MDE
Physiocontrol (Medtronic) - Lifepack12
Protocol Propaq - Protocol Propaq series; Propaq
106EL;
Spacelabs - Series 400, 500, 90308/11/31,
MOD-CD, CD-CV Tektronics - 400 Series
Vitalert – 2000
Vitatek - Series 400, 500
Welch Allyn - 1500
Zoll - Zoll Defribrillators
684081 – 12 Pin M - LF
684090 – 5 Pin M - LF
Philips
CMS (Merlin line), M1006A/B, M1026A / M1166A
/ Viridia / HP Scop Eurelie 24C, CMS2001, V24,
V26, M2, M3, M4, Intelivue
Mindray
BeneView T5, T8, T1; IPM (8, 10, 12);
BeneHeart D6
684082 – 10 Pin M - LF
Nihon Kohden
MFV1100,1200,1230A; Lifescope 8, 9, 11, 12, 14,
BSM-8300J/K, 3000, BSM4100
684096 – 8 Pin M - LF
Dräger/Siemens
400 Series, 960, 961, Sirecust 4041,700,1260,
342, 732, Sirecust 342, 4XX, 7XX, 9XX, 12XX
SC7000, SC8000, SC9000, Infinity Gamma, Delta,
Kappa, Vista all with 10 pin connector
GE / Marquette
7000 series, 7010, Mod 7200
Pressure Transducer Sets
684102 - 11 Pin M - LF
684128 – 10 Pin M - LF
GE / Marquette
GE Monitor with Marquette ‘front end’:
7009 / Tramscope Series(600SL), Eagle-Solar
8000, 9000, 3000/1000, Mab Lab 6Fx3F, Tram
450SL, 6200, Tram600A, EK36, Dash 3000, Dash
4000, Dash 5000
E for M/Honeywell
RM300
Dräger
PM8040, PM8060, Dräger Vitara, Cato, Cicero &
Julian Anes. machine,
Philips
CM140
684104 – 10 Pin F - LF
684129 – 12 Pin M - LF
GE / Datex-Ohmeda
GE Monitor with Datex-Ohmeda ‘front end’:
SYS 800, MOD 8641, SIVA 3000, Cardiocap,
Cardiocap II, AS3, S5, Aestiva, ADU(S5) and Aisys
Kontron, Arrow
Minimon 7131, 7132 etc, K2000, 7272 / Supermon
7210 / Cart 2 Plus, Balloon Pump, Oxford ACAT1
684109 – Pin N/A - LF
684138 – 5 Pin M
No Monitor Connection (‘flying lead’)
Wiring Guide:
Green: (+) Excitation Voltage
Red: (-) Excitation Voltage
Black: (+) Signal
White: (-) Signal
Shield: Dependant on monitor specification
Jostra
(Heart pump)
Pressure Transducer Sets
684178 – 7 Pin M - LF
Dräger/Siemens
SC6000P, 6002, 5000, 6004, 7000, Infinity Gamma,
Delta, Kappa, Vista all with 7 pin connector
684181 – 8 Pin M
684227 – 6 Pin M - LF
(identical to P/N 684085)
Spacelabs (Vitatek)
BCI - 400, 500, 90485, Alpha-PC, 90603A, BCI
9100, 90303B-Mod90470-05, CD-CV, 90369,
90385, 90470, 90496, Ultraview 1600
684236 – 15 Pin M
Prucka Eng Inc.
CARDIOLAB II / 1.1, AMP II
684188 - 4 Pin M
Dräger/Siemens
Hemo Pod Adapter (One adapter for each Hemo2
Pod & two for each Hemo4/HemoMed Pod)
684243 – 4 Pin M - LF
Stöckert (Sorin)
S3, S5
JP - 900P (OTCN KB559)
Stöckert (Sorin)
Heart Lung Machine
Nihon Kohden
NK9000
Pressure Transducer Sets
684056
Model: SP4042
684062
Model: SP4045
In-Line Injectate Sensor Cable
For use with Abbott Oximetrix, Arrow, Baxter,
Edwards 9520A or Com1, Mennen Horizon 2000
series (Cable 800-030-200), Spacelebs Alpha PC
or PCMS (bifurcated cable model 306655-001),
Datex AS3 and Argon Critikit Injectate Set or
SP5045 Sensor Housing
In-Line Injectate Sensor Cable
For use with Nihon Kohden, Spacelabs (bifurcated
cable model 306655-002), Fukuda Denshi IB5006
(DSCP), Dynascope DS3300 and Argon Critikit
Injectate Set or SP5045 Sensor Housing
684057
684063
Model: SP4043
In-Line Injectate Sensor Cable
For use with Siemens bifurcated cable, Siemens
Pod system (model 8419145) and Argon Critikit
Injectate Set or SP5045 Sensor Housing
Model: SP4046
In-Line Injectate Sensor Cable
For use with Philips Cardiac Output module (trifurcated cable M1641A or M1642A) and Argon Critikit
Injectate Set or SP5045 Sensor Housing
Critical Care catalogue 2005
16/2/05
3:32 pm
Page 21
Cannulae/Catheter Conversions
Cannulae/Catheter Conversions
Cannulae/Catheter Conversions
Cannulae/Catheter Conversions
Cannulae/Catheter
Conversions
Thedefinition
definition
gauge
measurement
comes
the AAMI
The
ofofgauge
measurement
comes
from from
the AAMI
(Association
for
the
Advancement
of
Medical
Instrumentation
(AssociationOuter
for theDiameters/Gauge-French
Advancement of Medical Instrumentation
Sizes
- USA).
This
states
cannulae
into awith
tube
USA).
This
states
how how
manymany
cannulae
fit intofit
a tube
anwith
inner
Theinner
definition
comes from the AAMI
an
diameter
of 1”
(1 inch = 25.4mm).
diameter
of
1”of
(1 gauge
inch
=measurement
25.4mm).
14
14
13
13
13
2.4
2.5
2,5
0.094
0,098
0.098
6 6
7
SWG
1
G
1.9
14G
14G
AAMI
65
20
24G
14
6
20
0.G9
91
15 15
5 5
65
0.
15
5
0.9
91
16 16
4
Outer Ø mm
18G
17G
27
Table
1.7
19
1.321
16G 24
1
SWG - AAMI
1.5 0 1.45 1.19 .118 G
5
1.1
1.
Outer Ø mm
70
18G
G 7
17G
.9
115.72 80 G
19 4
6
G
1. 1
1
5
.
1.4
1
18G 92 1.17
1.50
0
G
G
G 0.
16
94
15
80
1.
18G
20G
G
16
0.584 0.0.584
533 0.533
0.660 0.660
63
63
0.7 23G 24G
0.7
23G 24G
4
4
G
G
2
2
6
2
86
.8 2
0
G
G
21 0.66 0.58
21
0.66 0.58
9
9
0.6
0.6
17
16
4
0.
17
4
2.31
18
17
3
30
18
3
1.9
19
18
3
1 inch
1 inch
The
AAMI
uses
only
even
numbers
(18,
20,
22,
etc.)
as
measuring
The AAMI uses only even numbers (18, 20, 22, etc.) as
units. A similar measurement definition exists in Great Britain and
measuring units. A similar measurement definition exists in
this is known as the SWG (Standard Wire Gauge). The SWG uses
Great
Britain
and
is known as
the
SWGetc.)
(Standard
Wire
The AAMI
uses
onlythis
even
(18,
as measuring
consecutive
numbers,
ie 13numbers
to 24 and
is 20,
the 22,
more common
Gauge).
The
SWG
usesfor
consecutive
numbers,
ie 13
to 24and
and
units. A of
similar
measurement
definitioninexists
in Great
Britain
method
measurement
catheters
Europe.
The
Charriere,
this
is
known
as
the
SWG
(Standard
Wire
Gauge).
The
SWG
uses
is
the
more
common
method
of
measurement
for
catheters
commonly known as French, relates directly to the catheter size, ie
consecutive
numbers,
13 to
24 tables
and is the
the
moreas
common
in
Europe.
The
Charriere,
commonly
known
French,
1
Ch
= 0.33mm.
In theiefollowing
measurements
of the
method
of measurement
for
catheters
in
Europe.
The
Charriere,
relates
directly
to theare
catheter
size,
i.e.
1toCh
0.33mm.
In
AAMI
- SWG
- French
shown
in
relation
the=
outer
ø in mm.
commonly
known
as French,
relates directlyof
tothe
theAAMI
catheter
size, iethe
following
tables
the measurements
- SWG
1Table
Ch = 0.33mm.
In the
following
measurements
of the
1.321
1the
French
are shown
in 1relation
totables
the outer
ø in mm.
.1
.524
SWG - AAMI
AAMI
- SWG - French are
shown in relation18to the outer ø in mm.
1.9
14G
30
19
2
13G
14G
2.31
1.9
1
19
20
2
13G
20
20 21
2
2.184
21
21 22
0,027
0.027
0,024
0,031
0,027
0.031
0,035
0,031
0.035
0,039
0,035
0.039
0,043
0,039
0.043
0,047
0,043
0.047
0,051
0,047
0,055
0.051
0,051
0,059
0.055
0,055
0,063
0.059
0,059
0,067
0.063
0,063
0,071
0.067
0,067
0,075
0,071
0.071
0,079
0,075
0.075
0,083
0,079
0.079
0,086
0,083
0.083
0,091
0,086
0.086
0,094
0,091
0.091
0,098
0,094
9
2.48
2.1
84
22
24
22 23
0,024
0.024
0,019
2.489
23
0.019
(Association for the Advancement of Medical Instrumentation USA). This states how many cannulae fit into a tube with an inner
diameter of 1” (1 inch = 25.4mm).
1 inch
1 inch
0.
0,6
0.6 0,5
0,7
0.7 0,6
0,8
0.8 0,7
0,9
0.9 0,8
1,0
0,9
1.01,1
1,0
1.11,2
1,1
1.21,3
1,2
1.31,4
1,3
1.41,5
1,4
1,6
1.5
1,5
1,7
1.6 1,6
1,8
1.7 1,7
1,9
1.8 1,8
2,0
1.9 1,9
2,1
2.0 2,0
2,2
2,1
2.12,3
2,2
2.22,4
2,3
2.32,5
2,4
inch
0,019
Charriere
Charriere
(French)
(French)
1
Ch=0,33
mm
1Ch = 0.33mm
Charriere
(French)
1 Ch=0,33 mm
24G
G
22
24
2423
inch
Inch
G
outer Ø
Outer
Ø
mm
mm
outer Ø
mm
0,5
0.5
22
Gauge
(SWG)
Gauge
Gauge
(SWG)
Outer Diameters/Gauge-French Sizes
AAMI
BD’s
multi lumen catheter (Careflow™) hub colour
SWG
coding differentiates the
white
proximal
BD’s multi
catheter (Careflow™)
colour
lumens
andlumen
not the
brown hub tip
Argon’s
multi
lumen
catheter
(Careflow
)
hub
colour
coding differentiates
catheter
gauge, ie the
blue
middle
white
proximal
TM
7
7
coding differentiates
lumens
and not the the
lumens and
not ie
the
catheter
gauge,
catheter gauge, i.e.
white
brown
brown
blue
blue
proximal
tip
tip
middle
middle
Teflon™, Tyvek™ registered to Dupont Inc.
Teflon™,
Tyvek™ registered
to Dupont
Inc.
Nylon™
registered
to Atrochem
Corporation
Nylon™
registered
Atrochem
Corporation
BD,
BD logo
and all to
other
trademarks
are the property of Becton, Dickinson and Company. © 2004 BD
21
BD, BD logo and all other trademarks are the property of Becton, Dickinson and Company. © 2004 BD
21
Appendix
Quality Management with Argon
Argon products are designed and manufactured to meet applicable international Quality Management System
requirements in accordance with the European Medical Devices Directive 93/42/EEC (MDD) and FDA QSR where
applicable. Hence, all Argon manufacturing sites hold a valid certification against ISO 9001:2000 and/or ISO 13485:2003.
Likewise, all Argon manufacturing sites are subject of periodic external as well as internal audits to ensure compliance
with aforementioned Quality Management System requirements.
Symbol Guidance
The CE mark, signifying compliance with European Medical Device Directive.
Rx ONLY
Catalogue number/
reference number/
re-order number
Serial number
Lot number/batch
code/batch number
Fragile
Authorised representative
in the European
Community
Keep dry
Sterilised using
Ethylene Oxide
Do not re-use/single
use/use only once
Use by
Keep away
from sunlight
Date of manufacture
Do not use if
package is damaged
Manufacturer
Green Dot Recycle in Europe
This way up
Caution/attention/see
instructions for use
Does not contain
natural rubber latex
Contains or presence
of natural rubber latex
Contains or presence of
phthalates: Bis(2-ehylhexyl)
phthalate (DEHP)
Temperature limitation
Caution: Federal Law (USA)
restricts this device to sale by
or on the order of a physician
!
Caution, consult
accompanying documents
Index
The Netherlands
Finland
Denmark
Argon Medical Devices Netherlands B.V.
Argon Medical Devices Netherlands B.V.
Suomen sivuliike
Argon Medical Devices
Registered address:
Prins Bernhardplein 200
1097 JB Amsterdam
The Netherlands
Please send any correspondence to:
Beech Avenue 54-80
1119 PW Schiphol-Rijk
The Netherlands
Tel: +31 13 547 93 70
Fax: +31 20 799 80 32
[email protected]
Germany
Argon Medical Devices Netherlands B.V.
Zweigniederlassung Deutschland
Steinpilzweg 26
91058 Erlangen
Deutschland
Tel: +49-(0)9131-9085969
Fax: +49-(0)9131-9081964
[email protected]
Televisiokatu 3
00240 Helsinki
Finland
Tel: + 358 9 4730 5240
Fax: + 358 9 4730 5249
[email protected]
Belgium
Argon Medical Devices Netherlands B.V.,
Belgium Branch
Noordlaan 21
9200 Dendermonde
Belgium
Tel: + 32 3 218 22 75
Fax: + 32 3 218 20 20
[email protected]
Tel: +45 4547 5017
Fax: +45 4547 5016
[email protected]
UK
Argon Medical Devices Netherlands B.V.,
UK Branch
The Core Business Centre
Milton Hill
Abingdon, Oxfordshire OX13 6AB
United Kingdom
Tel: +44 (0) 1235 828293
Sweden
Argon Medical Devices Netherlands B.V. Filial
Sweden
Stora Åvägen 21
436 34 Askim
Sweden
Tel: +46 (0)31 723 84 91
Fax: +46 (0)31 723 84 69
[email protected]
© 2013 Argon Medical Devices Inc. All Rights Reserved.
No reproduction of any portion of this work shall be made without prior permission of the author.
96-4100-09/0413B
Dronninggårds Alle 136
2840 Holte
Denmark
www.argonmedical.com