IPC FEC Standard® with Analog Processing (FEC 620/FEC 660)

IPC FEC Standard®
with Analog Processing (FEC 620/FEC 660)
Digital or analog?
Extremely practical
Programming
This is the question that now
Analog inputs and outputs (3
FST is a classic and very easy-to-
arises with the FEC family of
AD/1 DA) for air flow
use PLC programming language
controllers.
measurement/monitoring, air-
that operates “the way you
consumption measurement,
think”: IF ... THEN ... OTHERWISE.
Systematically more flexible
temperature
In addition to this, FST offers
These are heavy-duty miniature
measurement/monitoring,
STEP operation for programming
controllers with analog signal
length/displacement
sequences. With the aid of basic
processing. The multifunctional
measurement, pressure/force
arithmetic functions, calculations
sensor/actuator connector,
measurement and, last but not
can be carried out quickly and
optionally with integrated 3-row
least, dynamically controlling
easily, while FST has an inte-
terminals, allows the direct
proportional valves.
grated PID controller module for
connection of sensors.
closed-loop control functions.
The FEC 660 can be programmed
via Ethernet if desired, can be
configured as a Web server.
IPC.FEC.PSI.US
Product Short Information
IPC FEC Standard®
with analog processing (FEC 620/FEC 660)
1
Features
2
5
1 32 digital inputs, 24 V DC, PNP
2 3 analog inputs, 1 analog
output
3 16 digital outputs
4 Power supply connector
5 Rotary RUN/STOP switch
Front End Display
6 2 serial interfaces,
Ethernet (FC660 only)
Push-buttons
1
3
4
6
FEC stand-alone solution
FEC network solution
– 2 serial interfaces
Ethernet interface is available
– COM interface for programming
on FC660 for:
– Web server
– Communication between
– Sending e-mails from the
and debugging
controllers
– EXT interfaces for operator
panel, barcode reader, modem,
Sensors
– Data exchange via a Windows
environment using DDE or OPC
controller
– Programming and debugging
etc.
IPC FEC ® Standard
FST
Ethernet
Valves
Technical data FEC 620/FEC 660
No. of analog inputs
3
Signal range
0 ... 20 mA (4 ... 20 mA via software)
Resolution
12 bits
Conversion time
1 ms
Max. cable length
30 m (screened)
No. of analog outputs
1
Signal range
0 ... 20 mA
Resolution
12 bits
Conversion time
1 ms
Max. cable length
30 m (screened)
Dimensions (W x H x D)
156.8 x 105 x 35 mm
Cylinders
Relays
Motors
Festo Corporation
Tel:
Fax:
E-mail:
Web:
Subject to change
1.800.99.FESTO
1.800.96.FESTO
[email protected]
www.festo.com/us
IPC.FEC.PSI.US
2.05