SALES: 1800 800 878 SERVICE & HIRE: 1800 802 697 EMAIL: [email protected] CONVERSION CHART Electric & Diesel Compressors Generators FLOWRATE CONVERSION CHART Blowers TO CONVERT cfm l/Sec to m3/min m3/hour l/sec m3/min m3/hour cfm m3/min m3/hour cfm l/sec m3/hour cfm l/sec m3/min Multiply By Air Treatment 0.472 0.0283 1.699 2.119 0.06 0.001 35.315 16.667 60 0.589 0.278 0.0167 Air Receivers Gas Generation Air Tools Hoists & Winches Energy Efficiency Services Aftermarket (Parts & Servicing) PRESSURE CONVERSION CHART TO CONVERT psi kPa to bar Atmospheres kPa bar Atmospheres bar Atmospheres psi kPa Atmospheres psi kPa bar psi Multiply By 6.895 0.069 0.068 0.01 0.0098 0.145 100 0.987 14.504 101.3 1.013 14.7 CONVERT kWh ELECTRICITY TO CO2 kg /pa Formula - kWh x hours run p/a x Relevant state CO2 multiplier INDIVIDUAL STATE CO2 MULTIPLIER CHART NSW / ACT VIC QLD SA WA TAS NT 1.07 1.37 1.02 0.85 0.93 0.35 0.77 Data from Department of Climate Change & Energy Efficiency ENERGY SAVINGS AVAILABLE VIA PRESSURE REDUCTION Energy Savings = 8% kW rating x pressure reduction x operating hours EXAMPLE 1: Reducing the system pressure on a 100 Kw air compressor from 8 bar to 7 bar operating for 8000 hours per year Energy Savings = 0.08 x 110 KW x 1 Bar x 8000 = 70,400 kWh per year $7,040 (@ $0.1/kWh) *Reducing compressed air supply pressure by 50 kPa = 4% reduction in power usage AIR LEAKAGE, WASTED ENERGY AND COST FOR EQUIVALENT HOLE DIAMETER EQUIVALENT HOLE DIAMETER (mm) QUANTITY OF AIR LOST IN LEAKS (l/s) ANNUAL ENERGY WASTE (kWh) ANNUAL COST OF LEAKS ($ AUD) 1.6 3.2 6.4 12.7 3.2 12.8 51.2 204.8 2,128 8,512 34,040 136,192 $213 $851 $3,404 $13,619 www.capsaustralia.com.au
© Copyright 2026 Paperzz