TECHNICAL GUIDE Meters Water | Heat | Gas pipecenter.co.uk Meters Contents Metering has become a crucial part of energy monitoring and billing for both commercial and domestic customers. Introduction To Meters 02 “Jet” Ultrasonic Meters 04 “Jet” Multijet Meters 08 This has resulted in an increase in legislation such as the MID (Measuring Instrument Directive) standard, product approvals and types. The JET range of meters encompasses these changes to offer high quality and up to date solutions for every application. The MID standard is an umbrella approval for all meters and is a requirement for all billing meters. The water meters have the MID R80 standard and the heat meters have various MID approvals, including Class 2 for the ultrasonic range which are ideal for RHI (Renewable Heat Initiative) applications. WRAS Approval up to 85°C applies to the range of water meters further demonstrating the quality of the products. The Heat Network (Metering and Billing) Regulations 2014 state that any heat supplier into a building that is either a District Heating Scheme or Communal Heating where heat was provided as part of a service charge must now all be metered for the end user and charged accordingly. “Jet” Woltmann Meters 10 “Jet” Wall Mounted Meters 12 “Jet” Gas Meters 14 Part L of the building regulations also requires metering, so it is important to choose carefully and install the appropriate products to ensure that the building is managed properly and in accordance with good practice. There are numerous product communication options available, such as pulsed output, M-bus, wireless etc. to suit all requirements, whether a one off or a large complex infrastructure. There are many solutions to metering that we can offer, whether for water, heating, gas or industrial processing with ultrasonic or magflow products. 02 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 03 Heat Meters The JET range of ultrasonic MID Class 2 meters range from Dn15 to Dn100 (up to Dn200 available) and are available with either pulsed, mbus or wireless output. These are ideal for long term, durable applications which require a high degree of consistent accuracy. There are no moving parts ensuring longevity in addition to maintaining the highly accurate wide flow range of 100:1 from minimum to maximum flow rates. Both the ultrasonic flow sensor and the calculator are supplied together as an integral unit, complete with temperature sensors. The normal method of operation is by battery with the option of mains power. These meters can be fitted vertically or horizontally without compromising performance. Renewable heat applications normally use heat meters. For the Renewable Heat Initiative (RHI) the preferred type is the MID Class 2 ultrasonic meters. The JET range of high quality Class 2 ultrasonic meters are ideal for domestic, commercial and RHI schemes. The JET range of heat meters have all the necessary approvals. These include MID (Measuring Instrument Directive) 2004/22/ EC, CEN EN 1434 (2007) and OIML R5 (2002). This also ensures accuracy, durability and that legal billing standards are met. A full range of interfaces are available to integrate the meters into any design of heat metering application from a single source. Ultrasonic Type (RHI Class 2 Standard) Wolseley Code Threaded 171741 171742 171743 171744 171745 - - - - Unions N22009 N22010 N22011 N22011 N22013 n/a n/a n/a n/a Flanged Dn Size (mm) Union Tails Flange Width C (mm) - - - - - 171746 171747 171748 171749 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 1/2” BSP Male 3/4” BSP Male 1” BSP Male 1” BSP Male 1 1/2” BSP Male - - - - - - - - - 165 185 200 235 Bolt Circle Centres D (mm) - - - - - 125 145 160 190 Minimum flow l/hr 15 25 35 60 100 150 250 400 600 Nominal Flow m3/hr 1.5 2.5 3.5 6 10 15 25 40 60 Maximum Flow m3/hr 3 5 7 12 20 30 50 80 120 Temp range °C 90 90 90 90 130 130 130 130 130 Length L (mm) 110 130 130 150 150 200 300 300 360 Height H (mm) 50 61 61 61 102 62 118 120 128 Nominal Pressure (Bar) 16 16 16 16 16 25 25 25 25 Pulsed Output Value (kw/h per pulse) 1 1 1 10 10 10 10 100 100 3/4” 1” 1 1/4” 1 1/4” 2” - - - - - - - - - Pn25 Pn25 Pn25 Pn25 Connection Threaded “A” Connection Flanged “C” • MID Class 2 Approved • Pulsed or M-bus versions available • Wireless options available • Battery or mains power versions available • Fluid temperature measurement range 1-130°C (90°C up to Qp10 size) • Large easy to read display • Constant display of total energy used • Horizontal or Vertical Mounting • No loss of data when changing battery • Connection of up to two additional meters possible • All major components are recyclable MID Approved 04 Flanged Threaded Sizes 50mm to 100mm Flanged version Sizes 15mm to 40mm Threaded version METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 05 Heat Meters Packs Heat Meters are generally used in applications such as central boiler services fitted to large buildings, or in District Heating schemes. Submetering is also a common application. Wall Mounted Heat Meter Packs c/w Multijet water meter Chilled water meters are typically used on air conditioning systems (note that temperature pockets are reversed for this application). (Pack contains Multijet water meter, heat meter 10L, c/w 3m cabel PIPO, stainless steel pockets M10 x 85mm) MID Approvals (Measuring Instrument Directive) enables manufacturers to obtain a single approvals certificate valid throughout Europe EN1434-6:1997 standard for heat meters, installation, commissioning, operational monitoring and maintenance. Chilled Hot Size mm Qmin l/hr Qt l/hr Qn M3/hr Qmax M3/hr Energy kW/h per pulse 600813 695457 15 30 120 1.5 3 10 600814 695458 20 50 200 2.5 5 10 600815 695459 25 70 280 3.5 7 10 Inline Heat Meter Packs 600816 695460 32 120 480 6 12 10 600817 695461 40 200 800 10 20 100 (Pack contains Inline heat meter and ball valve) 600818 695462 50 300 1050 15 30 100 600819 695463 50* 300 1200 15 30 100 All of our heating and chilled water meters include BMS pulsed output (MBUS is also an option) Qt l/hr Qn M3/hr Qmax M3/hr Energy kW/h per pulse 2.5 6 0.6 1.2 1 3 15 1.5 3 1 5 25 2.5 5 1 Chilled Hot Size mm Qmin l/hr 600810 695454 20 600811 695455 20 600812 695456 25 Suitable for larger flow rates greater than 2.5 M3/hr, includes flowmeter, integrator and pockets *PN16 flanged Wall Mounted Heat Meter Packs c/w Woltmann water meter Suitable for small pipework applications up to a flow rate of 2.5 M3/hr (appartments, underfloor heating, low flow applications) (Pack contains Woltmann water meter, heat meter 100L, c/w 3m cabel PIPO, stainless steel pockets M10 x 85mm) Chilled Hot Size mm QnMin M3/hr Qt M3/hr Qn M3/hr Qmax M3/hr Energy kW/h per pulse 600820 695464 50 0.45 3 15 30 100 600821 695465 65 0.75 5 25 50 100 600822 695466 80 1.2 8 40 80 100 600823 695467 100 1.8 12 60 120 100 600824 695468 125 3 20 100 200 100 600825 695469 150 4.5 30 150 300 100 600826 695470 200 7.5 50 250 500 100 Suitable for larger flow rates greater than 2.5 M3/hr, includes flowmeter, integrator and pockets 06 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 07 Water Meters Accessories MID R80 Approved Remote reader (Indoor use only, battery operated) One display unit per meter required Red Meter max. 90°C Sizes 15mm to 50mm Blue Meter max. 30°C Sizes 15mm to 50mm D500 10L Dn15 to Dn32 meters D500 100L Dn40 to Dn50 meters Pulse converter Converts a pulse signal from the meter to a modbus or mbus signal. Up to 5 pulsed inputs per module Multijet - Class B type DPMODBUS 5 inputs Pulse to Modbus converter DPMBUS 5 inputs Pulse to Mbus converter • MID R80 Approved • Epoxy Powder Coated Terms of Reference: • For cold (30°C) or hot (90°C) water • Real performances exceed MID standards Size (mm) - Refers to inside bore diameter • WRAS Approved up to 85°C • Screwed BSP for Union Connection Metrological Performance • Pulsed Output Fitted As Standard • Low flows Indicator Wheel Q MAX (Q4) = Max Flow Rate (Q m3/h) - Refers to the emergency flow rate in the event of system failure. Damage may result • Mbus or Modbus conversion option QN (Q3) = Nominal Flow Rate (QN m3/h) - typical application for everyday useage • Maximum working Pressure: 16 Bar • Standard Horizontal Installation (for vertical installation = 2x Trans Flow Rate) • Dry Dial - Large & easy to read • Security via tamper evident wire lock & seal • All major components are recyclable Q MIN (Q1) = Minimum Flow Rate (L/hr) - The absolute minimum flow rate required for the unit to function • Brass Body QT (Q2) = Transitional Flow Rate (L/hr) - Point of which the flow rate is high enough to achieve a level of accurate measurement MID R80 Approved - Measures accurately at very low flow rates Bolt Circle Centers - Refers to the distance between opposite bolt holes on the flange, taken centre to centre Cold (Pulsed Output) 171253 171254 Cold (Non-Pulsed Output) 171243 171243 - - - - - Hot (Pulsed Output) 171273 171274 171275 171276 171277 171278 171279 Unions N22009 N22010 N22011 N22012 N22013 N22014 FLANGED 2 (DN50) 2 (DN50) 31.25 31.25 Dn Size (mm) 171255 1/2 (DN15) 3/4 (DN20) 1 (DN25) Q Max (Q4) - Max Flow (m3/hr) 3.12 5 7.87 171256 171257 1-1/4 (DN32) 1-1/2 (DN40) 12.5 20 171258 QN (Q3) - Nominal Flow (m3/hr) 2.5 4 6.3 10 16 25 25 QT (Q2) - Trans Flow (l/h) 50 80 126 200 320 500 500 Q Min (Q1) - Flow (l/h) 32 50 78 125 200 312.5 300 Pulse (Litres Per Pulse)* 10 10 10 10 100 100 100 Body Length “L” (mm) 145 190 260 260 300 300 300 Body Length with Unions (mm) 230 280 370 375 420 435 n/a Height “H” (mm) 105 106 115 115 148 173 165 (dia. Outer) Width “W” (mm) 100 100 104 105 125 126 125 crs bolt circle Weight (kg) 1.5 1.7 2 3.2 5.4 8.2 11.5 - - - - - - 4 x M16 Bolt Dia. (mm) * Reed switch operates between 0-24 vdc Figures apply to both hot & cold metres 171259 Pressure drops on all sizes generally below 0.2 bar Current max 0.2 amps All sizes are approximate and are given for guidance only. Product and specification may be subject to change from those shown without notice. 08 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 09 Water Meters Accessories MID R80 Approved Remote reader (Indoor use only, battery operated) One display unit per meter required Blue Meter max. 30°C Red Meter max. 90°C D500 100L Dn50 to Dn125 meters D500 1000L Dn150 and upwards Pulse converter Converts a pulse signal from the meter to a modbus or mbus signal. Up to 5 pulsed inputs per module Woltmann type DPMODBUS 5 inputs Pulse to Modbus converter DPMBUS 5 inputs Pulse to Mbus converter • MID R80 Approved • Flanged to EN1092-2 PN16 Connection Terms of Reference: • Cold (up to 30°C) and hot (up to 90°C) • Supplied c/w Flange Gaskets Size (mm) - Refers to inside bore diameter • WRAS Approved up to 85°C • Epoxy Powder Coated Metrological Performance • Pulsed Output Fitted As Standard • Low flow Indicator Wheel Q MAX (Q4) = Max Flow Rate (Q m3/h) - Refers to the emergency flow rate in the event of system failure. Damage may result • Mbus or Modbus conversion option QN (Q3) = Nominal Flow Rate (QN m3/h) - typical application for everyday useage • Maximum working Pressure: 16 Bar • Standard Horizontal Installation (for vertical installation = 2x Trans Flow Rate) • Dry Dial - Large & easy to read • Security via tamper evident wire lock & seal • All major components are recyclable Q MIN (Q1) = Minimum Flow Rate (L/hr) - The absolute minimum flow rate required for the unit to function • For cold (30°C) or hot (90°C) water QT (Q2) = Transitional Flow Rate (L/hr) - Point of which the flow rate is high enough to achieve a level of accurate measurement MID R80 Approved - Measures accurately at very low flow rates Bolt Circle Centers - Refers to the distance between opposite bolt holes on the flange, taken centre to centre Cold 171260 171261 171262 171263 171264 171265 Hot 171280 171281 171282 171283 171284 171285 171286 Flange Pack T83149 T83150 T83151 T83152 T83153 T83154 T83155 2 (DN50) 2-1/2 (DN65) 3 (DN80) 4 (DN100) 5 (DN125) 6 (DN150) 8 (DN200) Dn Size (mm) Q Max (Q4) - Max Flow (m3/hr) 50 78 78.5 125 200 312 500 QN (Q3) - Nominal Flow (l/hr) 40 63 63 100 160 250 400 QT (Q2) - Trans Flow (m3/hr) Q Min (Q1) - Flow (m3/hr) 3 5 8 12 20 30 50 0.45 0.78 0.79 1.25 2 3.12 5 Pulse (Litres Per Pulse)* 100 100 100 100 100 1000 1000 Body Length “L” (mm) 200 200 225 250 250 300 350 Height “H” (mm) 225 242 255 265 275 325 352 Diameter Outer (mm) 165 185 200 220 250 285 340 Bolt Circle Centres (mm) 125 145 160 180 210 240 295 Weight (kg) 16.3 17 18 22.8 28.3 46 59.6 4 x M16 4 x M16 8 x M16 8 x M16 8 x M16 8 x M20 12 x M20 Bolt Dia. (mm) * Reed switch operates between 0-24 vdc Figures apply to both hot & cold metres 171266 Current max 0.2 amps Pressure drops on all sizes generally below 0.2 bar All sizes are approximate and are given for guidance only. Product and specification may be subject to change from those shown without notice. 10 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 11 Inline Mounted Compact Calculators Wall Mounted Calculators Features: • MID Approved • EEC Class C Approved (non RHI) • Pulsed Output or Mbus versions (2 inputs available) • Radio version option three versions 0.6 m3/hr or 1.5 m3/hr or 2.5 m2/hr • Battery operated (6 year life) • IP54 protection rating • Vertical or horizontal mounting for installation in RETURN FLOW Features: • MID approved • EMC C Class according to EN1434 • Pulsed Output or Mbus versions (PIPO or M-BUS) • For use with mechanical, ultrasonic or magflow meters • DN15-300 Applications • Battery or 230v AC versions • IP54 Protection Rating • Fitted with 3M cable (2 wire) Option of 10 metre cables • No dataloss when battery is removed • Measurement Range 1 to 150°C • Ambient Temperature 5 to 55°C • Temperature Resolution 0.01°C • Measuring Frequency 20 to 120 seconds • Data storage Six times a day in non-volitile memory • Application oriented display menu - easy scan • 12 monthly values readable on the display • PT500 sensors • Installation in sensor pockets (3 sizes available) Wall Mounted Calculator 171710 Cold Meter 171738 171739 171740 Hot Meter 171730 171731 171732 N22009 N22009 N22010 Union Tails Unions 1/2” BSP male 1/2” BSP male 3/4” BSP male Meter Ends 3/4” BSP parallel 3/4” BSP parallel 1” BSP parallel Flow 0.6m3/hr 1.5m3/hr 2.5m3/hr Size 20mm 20mm 25mm PIPO PIPO PIPO 1 kw/hr 1 kw/hr 1 kw/hr BMS Output Type Output Valve (per pulse) Ball Valve with Temperature Pocket 171712 171713 15-32mm 40-125mm 150mm 15-32mm 40-125mm 150mm 171736 3/4” BSP BMS Output Type PIPO PIPO PIPO M-BUS M-BUS M-BUS 171736 3/4” BSP Ball valve for 20mm in line heat meter (1.5m3/hr) Pulse input value 10 L 100 L 1000 L 10 L 100 L 1000 L 171737 1” BSP Ball valve for 25mm in line heat meter (2.5m3/hr) 100 kw/hr 100 kw/hr 1 mw/hr 100 kw/hr 100 kw/hr 1 mw/hr 0.1 0.1 1 0.1 0.1 1 Battery Battery Battery Mains Mains Mains Suitable Meter Sizes Output value (per pulse) Volume (M3 / pulse) Power Source 171711 171714 171715 Ball valve for 20mm in line heat meter (0.6m3/hr) One required with Inline Meter Pulse converter Ball Valve with Temperature Pocket 171736 Ball valve for 20mm in line heat meter (0.6m3/hr) 171736 Ball valve for 20mm in line heat meter (1.5m3/hr) 171737 Ball valve for 20mm in line heat meter (2.5m3/hr) The meters as standard have either a pulsed or mbus output. To offer flexibility and compatibility with existing networks, a converter may be used. Converts a pulse signal from the meter to a modbus or mbus signal. Up to 5 pulsed inputs per module. DPMODBUS 5 inputs Pulse to Modbus converter DPMBUS 5 inputs Pulse to Mbus converter Two required with Inline Meter Stainless Steel Pockets 171720 1/2” BSP x 85mm 171721 1/2” BSP x 120mm 171722 1/2” BSP x 210mm Two required with Inline Meter 12 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 13 Gas Meters Gas Meters Description: The JET range of precision gas meters covers all domestic and commercial requirements, for both natural and LPG gas. All meters have a pulsed output as standard. Diaphragm Gas Meter (Pulsed) Wolseley Code Dn Size (mm) Flow rating Qmax (m3/hr) Qn Nominal Flow (m3/hr) Flanged Gas Turbine Meter P05385 P05386 P05387 P05388 P05389 3/4” (DN20) 1” (DN20) 1-1/4” (DN32) 1-1/2” (DN40) 2” (DN50) G4 G6 G10 G16 G25 6 10 16 25 40 Qn Nominal Flow (m3/hr) 10 10 Qmin- (m3/h) 1.5 1.5 Pule output value m3 0.1 0.1 4 6 10 16 25 Qmin- (m3/h) 0.04 0.06 0.1 0.16 0.25 Pule output value m3 0.01 0.01 0.01 0.1 0.1 Wolseley Code P05390 P05391 P05392 P05393 P05394 P05395 P05396 P05397 P05398 3/4” (DN20) 1” (DN20) 1-1/4” (DN32) 1-1/2” (DN40) 2” (DN50) 3” (DN80) 4” (DN100) 6” (DN150) 8” (DN200) Flow rating n/a n/a n/a n/a G40 G160 G250 G650 G1600 Qmax (m3/hr) 30 30 30 30 65 250 400 1000 2500 10 10 30 112 200 500 1200 1.5 1.5 6 13 20 50 80 0.1 0.1 0.1 1 1 1 1 Dn Size (mm) Width mm (D) 205 276 350 405 465 Length mm 170 170 170 170 100 120 150 180 600 Height mm (B) 228 282 311 375 375 Height mm 74 74 74 74 252 278 305 351 480 Depth mm (E) 160 202 202 275 275 Width mm 73 73 73 73 130 154 182 232 410 Weight kg 1.9 3.8 4.2 8 8.5 Weight kg 0.8 0.8 1 1 3.8 5.5 7.5 12 32 Pulse converter Pulse converter Converts a pulse signal from the meter to a modbus or mbus signal. Up to 5 pulsed inputs per module. Converts a pulse signal from the meter to a modbus or mbus signal. Up to 5 pulsed inputs per module. DPMODBUS 5 inputs any size gas meter Pulse to Modbus converter DPMODBUS 5 inputs any size gas meter Pulse to Modbus converter DPMBUS 5 inputs any size gas meter Pulse to Mbus converter DPMBUS 5 inputs any size gas meter Pulse to Mbus converter 14 METERS - WATER | HEAT | GAS METERS - WATER | HEAT | GAS 15 Branch Directory Branch Address Postcode Telephone Barking Unit 4, The Invicta Centre, Alfreds Way, Barking IG11 0BA 0208 594 4010 Basildon Paycocke Road, Basildon, Essex SS14 3JS 01268 246 990 Brentford Unit 7, Great West Trading Estate, 985 Great West Road, Brentford, Middlesex TW8 9DN 0208 560 4605 Croydon Unit 6, Beddington Cross, Beddington Lane, Croydon CR0 4XH 0208 665 1003 Dunstable Unit 23, Derby Road, Metropolitan Business Park, Greenford, Middlesex UB6 8UJ 0208 578 2300 Kings Cross Unit 30, Cedar Way, Elm Village Industrial Estate, Camden, London N1C 4PD 0207 380 4230 Luton Unit 8B, Cosgrove Way Industrial Estate, Luton, Bedfordshire LU1 1XL 01582 404 162 Orpington Unit 3, Denvale Trade Centre, Cray Avenue, Orpington, Kent BR5 3RN 01689 827 200 Slough 838-840 Yeovil Road, Slough Trading Estate, Slough SL1 4JG 01753 843 550 Strood Unit 4, Deacon Trading Estate, Knight Road, Strood, Kent ME2 2AU 01634 290 469 Tottenham Unit 17, Mowlem Trading Estate, Leeside Road, Tottenham, London N17 0QJ 0208 808 6633 Carlisle Unit 4, Grearshill Road, Kingstown Industrial Estate, Carlisle CA3 0ET 01228 819 647 Doncaster Unit 4, Kirk Sandall Network Centre, Kirk Lane, Kirk Sandall, Doncaster DN3 1GZ 01302 883 011 Hull Leads Road, Hull, East Yorkshire HU7 0BY 01482 838 880 Leeds Gelderd Trading Estate, 7 West Vale, Leeds, West Yorkshire LS12 6BD 0113 244 2161 Liverpool Unit 10, Atlantic Way, Section 3, Demster Buildings, Brunswick Business Park, Liverpool L3 4BE 0151 702 8700 Manchester Textilose Road, Trafford Park, Manchester M17 1WA 0161 872 8431 Newcastle Unit 31, New York Way, New York Industrial Estate, Newcastle, North Tyneside NE27 0QF 0191 296 1200 Sheffield Unit 4, Tinsley Park Close, Off Shepcote Lane, Tinsley, Sheffield S9 5DE 0114 242 4940 Stockton 20/25 Pennine Avenue, North Tees Industrial Estate, Stockton-on-Tees, Cleveland TS18 2RJ 01642 671 904 Stoke Sutton Street, Chesterton, Newcastle under Lyme ST5 7JH 01782 564 908 York Seafire Close, North York Trading Estate, York, North Yorkshire YO30 4UU 01904 691 111 Birmingham - Aston Units C&D, 4-6 Bracebridge Street, Dartmouth Industrial Estate, Birmingham B6 4NE 0121 359 7091 Birmingham - West Bromwich Unit B, Doranda Way, Doranda Way Industrial Park, West Bromwich B71 4LE 0121 500 3700 Cambridge Unit D, Beadle Trading Estate, Ditton Walk, Cambridge CB5 8PD 01223 275 200 Derby Dunstall Park Road, Off Ascot Drive, Derby DE24 8HJ 01332 297 222 Ipswich Unit 22, Foxtail Road, Ransomes Park, Ipswich IP3 9RT 01473 270 072 Leicester Unit 7, Highcliffe Road, Hamilton Industrial Park, Leicester LE5 1TY 0116 276 3709 Northampton Unit 2, Hartburn Close, Crow Lane Industrial Estate, Northampton NN3 9UE 01604 410 888 Norwich 189-191 Aylsham Road, Norwich, Norfolk NR3 2AD 01603 258 080 Nottingham Unit 5, Centurian Way, Riverside Industrial Estate, Nottingham NG2 1RW 0115 957 8200 Nottingham Crossgate Drive, Queens Drive Industrial Estate, Nottingham, Nottinghamshire NG2 1LW 0115 934 0500 Wolverhampton 34 Birmingham Road, Wolverhampton WV2 3LT 01902 455 854 Bristol Bonville Road, Brislington Trading Estate, Bristol, Avon BS4 5SE 0117 977 0733 Cardiff Unit 3 , Dominion Way Industrial Estate, Off Newport Road, Cardiff CF24 1RF 02920 480 046 Exeter Unit 3 Grace Units, Grace Road, Marsh Barton, Exeter EX2 8QA 01392 491 777 Gloucester Unit 8, Central Trading Estate, Cole Avenue, Gloucester GL2 5HA 01452 393 870 Hereford Unit 3, Three Elms Trading Estate, Three Elms Road, Hereford HR4 9PU 01432 370 899 Oxford Unit 35, Botley Works North, Hinksey Lane, Botley, Oxford OX2 0LS 01865 200 599 Plymouth Unit C, Plymouth Trade Park, Macadam Road, Cattedown, Plymouth, Devon PL4 0RU 01752 226 955 Poole 23 Witney Road, Sabre Business Park, Nuffield Industrial Estate, Poole, Dorset BH17 0GL 01202 666 748 Southampton Quayside Road, Southampton SO18 1AD 02380 635 633 Swansea 16a Mannesmann Close, Llansamlet, Enterprise Park, Swansea SA7 9AH 01792 797 079 Swindon Unit 9, Techno Trading Estate, Bramble Road, Swindon SN2 8HB 01793 694 000 Aberdeen Unit 1, Blackness Industrial Centre, Blackness Road, Altens, Aberdeen AB12 3LH 01224 872 990 Belfast Unit 12, 38 Montgomery Road, Belfast, N Ireland BT6 9HN 02890 791 222 Dundee Unit 6, George Buckman Drive, Camperdown Industrial Park, Dundee, Tayside DD2 3SN 01382 816 427 Edinburgh Unit 5, Bankhead Crossway North, Sightill Industrial Estate, Edinburgh EH11 4BP 0131 442 4949 Glasgow Unit 6, 31 Orton Place, Moorpark Industrial Estate, Govan, Glasgow G51 2HF 0141 425 2700 Glasgow 100 Townsend Street, Port Dundas, Glasgow G4 0LB 0141 331 7990 Inverness Unit 2, Seafield Trading Estate, 51 Seafield Road, Inverness IV1 1SG 01463 248 773 London & South East North Central Wales & South West Scotland & Northern Ireland pipecenter.co.uk
© Copyright 2026 Paperzz