CELEBRATING YEARS HIGH PERFORMANCE MASS SPECTROMETERS Nu Plasma II Multi-Collector ICP-MS FOR ISOTOPIC AND ELEMENTAL ANALYSIS Aspect HR Stable Isotope Ratio MS Astrum Glow Discharge MS PRODUCT BROCHURE Panorama HR Stable Isotope Ratio MS Nu Plasma 1700 Multi-Collector ICP-MS Evolution HR Gas Analysis MS Nu TIMS Thermal Ionisation MS Horizon Stable Isotope Ratio MS Noblesse Noble Gas MS Attom High Resolution ICP-MS Perspective Stable Isotope Ratio MS 15846 www.nu-ins.com Nu Instruments Limited, Unit 74, Clywedog Road South, Wrexham, LL13 9XS UK. Tel: +44 (0)1978 661304 Email: [email protected] Email: [email protected] YEARS CELEBRATING Fax: +44 (0)1978 664301 EARTH & PLANETARY FORENSIC & CLINICAL BR05.2.0315 I NUCLEAR I I MATERIAL ENVIRONMENTAL I I FOOD SAFETY CHEMICAL DELIVERING UNCOMPROMISED PERFORMANCE THROUGH NEW TECHNOLOGY CELEBRATING 20 YEARS IN ISOTOPIC AND ELEMENTAL ANALYSIS Founded in 1995 by Dr Phil Freedman, Nu Instruments is a market leading designer and manufacturer of high performance mass spectrometers. Our expanding range of specialist products reflects not only our experience and technical proficiency, but our commitment to develop and deliver the most efficient and innovative industry solutions. Our very first instrument was the Nu Plasma MC-ICP-MS, which was delivered to Oxford University in 1997. Since then 9 other instruments have been added to the range, with the Panorama HR Stable Isotope Ratio MS being the GLOBAL MARKET latest addition to the family. Our instruments are manufactured in the UK and used Dr Phil Freedman by scientists in Academic and Research Laboratories worldwide. We take pride in providing our customers with a personal service through our global network of service and support engineers. INNOVATION & QUALITY At the core of our operation lies a dedicated R&D team of scientists and engineers, who strive to design and develop innovative ways of meeting the needs of our users. Our instruments are known for their: • Unbeatable analytical capability • Ease of use • Reliability & robustness • Low cost of ownership Panorama HR Stable Isotope Ratio MS E A R T H A N D P L A N E TA R Y | NUCLEAR | FORENSIC & CLINICAL | E N V I R O N M E N TA L | M AT E R I A L | FOOD SAFETY | CHEMICAL nu plasma II nu plasma 1700 MULTI-COLLECTOR ICP-MS MULTI-COLLECTOR ICP-MS The Nu Plasma II is a Multi Collector ICP The Nu Plasma 1700™ plasma source multi- Mass Spectrometer (MC-ICP-MS), designed Features collector mass spectrometer is a large to provide the best possible precision for • Double focussing high precision isotopic measurement mass spectrometer dispersion high resolution multi-collector simultaneous isotopic ion detection. The instrument utilises a unique, patented, variable dispersion ion optical Zoom lens enabling the simultaneous measurement of the isotopes of elements from lithium to uranium on its static collector array of sixteen Faraday detectors and up to six ion-counting ICP-MS. • Up to six large discrete dynode ion-counting multipliers valley) while maintaining peak flats for the • Variable independently-adjustable high resolution system for each channel ultimate in precise and accurate simultaneous • State-of-the-art ceramic Faraday detectors • High abundance deceleration filters available for individual ion-counting multipliers geometry enables resolutions of >5000 (10% isotopic measurements. • Up to five multiplier detector system • Compact torch box design with an externally mounted sample introduction system resolution slit system, allowing different upgradability and flexibility, the Nu Plasma II • Enhanced pumping configuration This unique feature gives the Nu Plasma represents a major advancement in Multi- • Enhanced Sensitivity option Ground potential analyser operation provides ease of access, serviceability and excellent reliability. With its high precision, accuracy, reliability, Collector ICP technology, making it the instrument of choice for Geological/Earth Science, Forensic Science, Environmental Science, Biochemistry, Biomedical Science and Nuclear Science laboratories. • High resolution and pseudo resolution capability Uniquely for a MC-ICP-MS, the large Furthermore, each Faraday and ion counting multipliers. • Double-focussing mass spectrometer with ultra-large dispersion • Sixteen Faraday detectors, each with a 55V dynamic range • Enhanced variable Zoom Optics for maximum flexibility electron Features • High resolution and pseudo high resolution capabilities multiplier detector has its own variable high resolution settings on individual detectors. 1700™ capabilities that cannot be matched by other MC-ICP-MS instruments. • High abundance deceleration filters • Unique pumping configuration • Ground potential analyser operation • High ionisation efficiency ICP source • Laminated magnet • State-of-the-art electronics • Ground potential analyser operation • Bespoke software with full monitoring of all instrument parameters • Compatible with third party accessories • Open access software policy HIGH RESOLUTION ICP-MS GLOW DISCHARGE MS The Attom from Nu Instruments is a double The Astrum is a Glow discharge mass Features spectrometer characterisation of conductive and non- designed to be the ultimate tool for rapid • Double focussing HR-ICP-MS with analyser and sample introduction system at ground potential and precise isotope ratio and quantitative • High ionisation efficiency ICP source quantifying virtually all elements from lithium analysis of trace elements in solid and liquid • Five programmable gas flow controllers focussing inductively coupled plasma mass spectrometer that has been purpose (GD-MS) • Easy access Peltier cooled spray chamber for the conductive materials. It is capable of to uranium, and from matrix to sub part-perbillion. The instrument matrices. used combines a glow discharge ion source with a high resolution Features • Glow discharge source based on proven technology with reduced flow static discharge for maximum stability • Tantalum cell construction for ease of cleaning • Pin and flat sample configurations for maximum analytical flexibility • Easy connection of alternative sample introduction systems mass spectrometer and is a major step • Easy sample changeover using a unique loading probe forward in GD-MS, from the cryo-cooled detector system make the Attom a • High performance ion extraction and transfer optics tantalum source/cell and rapid sample • Cryo-cooled source for analysis of low melting point samples and minimisation of background gases powerful analytical tool. Furthermore, the • All turbo pumped (water cooled) vacuum system changeover system through to the bespoke The unique fast scanning techniques, coupled with a novel wide dynamic range flexible high resolution slit system offers the best solution between sensitivity and resolution for unambiguous determinations in complex matrices. control software. The durable construction of • All vacuum pumps and sensors operated at ground potential the instrument and proven source design give maximum uptime with minimal intervention. • Double-focussing mass spectrometer, based on field proven technology • Continuously variable high resolution capabilities from 400 to >10000 (10% valley definition) • ‘FastScan’ scanning technology with multiple scan modes • Faraday and ion counting multiplier for wide dynamic range • Low noise discrete dynode electron multiplier • Determination of matrix to sub-ppb elements in a single scan • Unique patented detector attenuation system, no analogue mode required • Purpose built electronics with monitoring of all instrument parameters • Optional Faraday detector for 12 orders of magnitude dynamic range • Unique pumping configuration • Powerful and easy to use software for instrument control and data processing • Bespoke software with intuitive instrument control and data analysis THERMAL IONISATION MS Noblesse The Nu TIMS is a Thermal ionisation mass Over the last decade, Nu Instruments’ spectrometer (TIMS) designed for precise and accurate measurement of elemental isotopic ratios. It has been developed using our field-proven variable dispersion multicollector technology to improve the versatility and overall performance of this long established analytical technique. The instrument combines design advances in filament assembly, ion optics and electronics control with ease of use and high precision. The Nu TIMS utilises our unique, patented Features detectors. The optional ion-counting mini has established a solid track record in analysis • Enclosed filament assembly designed for reduction of cross contamination successfully for applications as diverse as Ar- • Rapid pumpdown for high throughput and Liquid nitrogen dewar with 24 hour supply • Patented Zoom optics for reliable peak alignment and no moving detectors, providing unrivalled method flexibility of all the noble gases. Noblesse has been used Ar dating of young samples, studies of noble gases from the Earth’s mantle, and measurement of Krypton and Xenon in solar wind samples returned by NASA’s Genesis mission. Different collector arrays are Features • High efficiency Nier source • Multi-collector options – many developed in collaboration with users • Minimal internal volumes • Total ‘dry’ pumping technology • Unique electrostatic Zoom Optics (patented) – fixed collector array, no moving parts, increased reliability available, many developed in collaboration • User configurable detector array with optional ioncounting systems, utilising full size ion-counting electron multipliers and Daly detectors with users for particular applications. The • Easy source filament change collectors are fixed, yet due to the • Five ion-counter option for small sample analysis in the nuclear sector • State of the art purpose built electronics instrument’s unique, patented, variable samples and low abundance isotopes, • Easy to use modern software suite with full instrument and operation control with automatic sample analysis provides the ultimate in stability, linearity and • Optional Degas bench for 20 filaments dynamic range. • Lifetime instrument support provided by Product Specialists Daly, capable of precise measurement of small Noblesse multi-collector mass spectrometer • Single and double filament configuration with 20 sample turret Zoom lens system to ensure perfect peak alignment without the requirement of moving NOBLE GAS MS dispersion Zoom lens system, instantaneous • Fully bakeable to 300 deg C switching is possible between different sets of • Intuitive control software operating under Windows isotopes. • Optional sample preparation system PERSPECTIVE STABLE ISOTOPE RATIO MS STABLE ISOTOPE RATIO MS The Horizon IRMS is designed for flexibility, The Nu Instruments Perspective geometry Features reliability and high performance, with user Features friendly instrument control and data analysis • High efficiency ion source with integral focussing lenses instruments. Designed for flexibility, high achieve precise measurements from the smallest powerful new features for both Dual Inlet and • Fully differentially pumped as standard, optimal pumping for both dual inlet and continuous flow applications Continuous Flow analysis for the best possible • Electromagnet stabilised with Hall probe control The Perspective with its standard collector • High efficiency, narrow entrance, deep Faraday collectors block sets a new benchmark in performance for • Amplifiers capable of measuring signals above 55V uses our patented variable dispersion Zoom routine stable isotope ratio applications for the • 100% analyser transmission Optics to monitor masses from 2 to 100 with • Amplifiers capable of measuring signals above 55V measurement of carbon, nitrogen, oxygen, • State-of-the-art electronics with full self-diagnostics • 100% analyser transmission sulphur and hydrogen. The addition of the IS • Unique SIRMS collector arrays using patented “Variable Zoom Optics” (with no moving parts) software. This next generation instrument possesses isotope ratio data. The unique collector array exact coincidence. forms the basis for two state of the art IRMS performance and reliability, it has the ability to sample. • State-of-the-art electronics with full self-diagnostics collector block, transforms the instrument into • Unique SIRMS collector arrays using patented “Variable Zoom Optics” (with no moving parts) the Perspective IS, which has the capability to • All masses, including H2, are measured at the full deflection radius • Integral ion source heater (temperature up to 200°C) analyse clumped isotopes with exceptional sensitivity and linearity. • High efficiency ion source with integral focussing lenses • Fully differentially pumped as standard • Hall probe stabilised electromagnet • High efficiency, narrow entrance, deep Faraday collectors • All masses, including H2, are measured at the full deflection radius • Integral ion source heater (temperature up to 200°C) • Simultaneous ion beam collection using up to twelve Faraday collectors • All masses measured at full 8kV accelerating potential • Simultaneous ion beam collection using up to six Faraday collectors • Mass resolution CNOS and H (m/Δm) >200 (10% valley) • Large mass dispersion - 30cm effective magnetic deflection radius for CO2 • Mini electrostatic filters for measurement of clumped isotopes and HD • All masses measured at full 5kV accelerating potential • Mass resolution CNOS and H (m/rm) >110 (10% valley)
© Copyright 2026 Paperzz