Logix5000 Clock Update Tool V2.00.36

Logix5000 Clock
Update Tool V2.00.36
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved.
1
Overview
Logix5000 Clock Update Tool
1.1.What
Whatisisit?
it?
2.2.How
Howwill
willitithelp
helpme?
me?
3.3.How
Howdo
doIIuse
useit?
it?
4.4.When
Whencan
canIIget
getit?
it?
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
2
What Is It?
• Free-of-charge application that allows you to manually and automatically
synchronize controllers’ wall clock time with PC’s time
– Automatic synchronization can be scheduled at intervals as fast as every minute
and as slow as one month
• Allows for configuration of up to 110 different devices, and up to 3
independent synchronization schedules.
• Improved version of tool called Chronos
• Requires RSLinx Classic Lite
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
3
How Will It Help Me?
• Allows easy and unattended synchronization of devices’ time
– Takes care of devices’ clock drift
– Need not to worry about daylight saving time or leap year changes
• It increases the effectiveness of time-stamping
• Eliminates the need to reset the device’s clock after
maintenance or power cycle
• Doesn’t require specialty “synchronization” module in each rack
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
4
Tool Overview
Add device
Add
schedule
Remove
schedule
PC’s clock
Schedules
List of
devices
Activity Log
12/13/2005
Time and date
when last update
occurred
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
Free-running time
difference
5
Features
• Allows for Manual synchronization, or up to three independent schedules
• Uses PC’s regional settings for date and time formatting
– Solves Daylight Savings Time and Leap year issues
• RSLogix 5000 and firmware version independent
• Appears on the Custom Tools menu of RSLogix 5000 (v13 and higher)
• Supports Logix5000 and others devices
– ControlLogix, CompactLogix, FlexLogix, DriveLogix and GuardLogix
– MicroLogix 1500, SLC500, PLC5, PowerMonitor II, and PowerMonitor 3000
– See on-line help for detailed list of products supported
• Accuracy is dependent on controller and network load
• Ability to start when Windows starts, and
minimize to the system tray to synchronize
devices in the background
• Leverages RSLinx Classic Lite
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
6
How Do I Use It?
• Step 1 - Add Devices
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
7
How Do I Use It?
• Step 2 - Setup a schedule
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
8
Accuracy
– 99% of readings indicated that the
controller and PC were less than
100ms apart
– 93% of readings indicated that the
controller and PC were less than
50ms apart
Accuracy
AccuracyTest
Test
300
300
Time Difference (ms)
Time Difference (ms)
• Actual accuracy will depend on
Controller’s load, network type,
network traffic, and may be
affected by the Overhead Time
Slice
• In the tests we administered…
250
250
200
200
150
150
100
100
50
50
0
0
• Based on these test results, this
tool may not be appropriate for
Sequence of Events Applications
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
9
Supports for Features Planned for V16
• Supports Universal Coordinated Time
(UTC) (Formerly known as GMT).
• Sets Time Zone and Daylight Savings
Time based on the user’s PC settings
• Requirements
– Device to be synchronized and PC must
reside in the same time zone.
– Requires V16 or higher Firmware for new
features. Devices with pre-V16 firmware
will store the local time, ignoring the time
zone and daylight saving time.
• Note: Users should avoid setting the Time
Zone or Daylight Savings Time from RSLogix
5000, as any changes will be overwritten
during the next synchronization.
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
10
In Conclusion…
• Allows easy, unattended, time synchronization for Logix5000
controllers and other devices
• Distributed Free of Charge
• RSLogix 5000 and Firmware independent.
– Relies only on RSLinx Classic Lite
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
11
Copyright / Trademark Notice
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
RSLogix, RSLinx, RSNetWorx, the RSLogix 5000 logo, and the Rockwell Software logo are
trademarks of Rockwell Software Inc. Logix5000, PLC-5, SLC-500 and Data Highway are
trademarks of Allen Bradley Company LLC., all other trademarks are the property of their
respective holders and are hereby acknowledged
For more information on the latest pricing or a demonstration of any Rockwell Software
package, please contact your local Rockwell Automation sales office or authorized AllenBradley distributor. For the very latest on Rockwell Software product development, visit our
Web Site on the Internet at:
http://www.software.rockwell.com
WORLDWIDE REPRESENTATION
Argentina, Australia, Austria, Bahrain, Belgium, Bolivia, Brazil, Bulgaria, Canada, Chile, China, Colombia, Costa Rica, Croatia Cyprus, Czech Republic, Denmark, Dominican
Republic, Ecuador, Egypt, El Salvador, Finland, France, Germany, Ghana, Greece, Guatemala, Honduras, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel, Italy,
Jamaica, Japan, Jordan, Kenya, Kuwait, Lebanon, Macao, Malaysia, Malta, Mauritius, Mexico, Morocco, Netherlands, New Zealand, Nigeria, Norway, Oman, Pakistan, Panama,
Peru, Philippines, Poland, Portugal, Puerto Rico, Qatar, Romania, Russia, Saudi Arabia, Singapore, Slovakia, Slovenia, South Africa, Republic of South Korea, Spain, Sweden,
Switzerland, Taiwan, Thailand, Trinidad, Tunisia, Turkey, United Arab Emirates, United Kingdom, United States, Uruguay, Venezuela, Vietnam, Zimbabwe
12/13/2005
Copyright © 2005 Rockwell Automation Inc., All Rights Reserved
12