Logix5000 Clock Update Tool V2.00.36 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved. 1 Overview Logix5000 Clock Update Tool 1.1.What Whatisisit? it? 2.2.How Howwill willitithelp helpme? me? 3.3.How Howdo doIIuse useit? it? 4.4.When Whencan canIIget getit? it? 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 2 What Is It? • Free-of-charge application that allows you to manually and automatically synchronize controllers’ wall clock time with PC’s time – Automatic synchronization can be scheduled at intervals as fast as every minute and as slow as one month • Allows for configuration of up to 110 different devices, and up to 3 independent synchronization schedules. • Improved version of tool called Chronos • Requires RSLinx Classic Lite 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 3 How Will It Help Me? • Allows easy and unattended synchronization of devices’ time – Takes care of devices’ clock drift – Need not to worry about daylight saving time or leap year changes • It increases the effectiveness of time-stamping • Eliminates the need to reset the device’s clock after maintenance or power cycle • Doesn’t require specialty “synchronization” module in each rack 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 4 Tool Overview Add device Add schedule Remove schedule PC’s clock Schedules List of devices Activity Log 12/13/2005 Time and date when last update occurred Copyright © 2005 Rockwell Automation Inc., All Rights Reserved Free-running time difference 5 Features • Allows for Manual synchronization, or up to three independent schedules • Uses PC’s regional settings for date and time formatting – Solves Daylight Savings Time and Leap year issues • RSLogix 5000 and firmware version independent • Appears on the Custom Tools menu of RSLogix 5000 (v13 and higher) • Supports Logix5000 and others devices – ControlLogix, CompactLogix, FlexLogix, DriveLogix and GuardLogix – MicroLogix 1500, SLC500, PLC5, PowerMonitor II, and PowerMonitor 3000 – See on-line help for detailed list of products supported • Accuracy is dependent on controller and network load • Ability to start when Windows starts, and minimize to the system tray to synchronize devices in the background • Leverages RSLinx Classic Lite 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 6 How Do I Use It? • Step 1 - Add Devices 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 7 How Do I Use It? • Step 2 - Setup a schedule 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 8 Accuracy – 99% of readings indicated that the controller and PC were less than 100ms apart – 93% of readings indicated that the controller and PC were less than 50ms apart Accuracy AccuracyTest Test 300 300 Time Difference (ms) Time Difference (ms) • Actual accuracy will depend on Controller’s load, network type, network traffic, and may be affected by the Overhead Time Slice • In the tests we administered… 250 250 200 200 150 150 100 100 50 50 0 0 • Based on these test results, this tool may not be appropriate for Sequence of Events Applications 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 9 Supports for Features Planned for V16 • Supports Universal Coordinated Time (UTC) (Formerly known as GMT). • Sets Time Zone and Daylight Savings Time based on the user’s PC settings • Requirements – Device to be synchronized and PC must reside in the same time zone. – Requires V16 or higher Firmware for new features. Devices with pre-V16 firmware will store the local time, ignoring the time zone and daylight saving time. • Note: Users should avoid setting the Time Zone or Daylight Savings Time from RSLogix 5000, as any changes will be overwritten during the next synchronization. 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 10 In Conclusion… • Allows easy, unattended, time synchronization for Logix5000 controllers and other devices • Distributed Free of Charge • RSLogix 5000 and Firmware independent. – Relies only on RSLinx Classic Lite 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 11 Copyright / Trademark Notice Copyright © 2005 Rockwell Automation Inc., All Rights Reserved RSLogix, RSLinx, RSNetWorx, the RSLogix 5000 logo, and the Rockwell Software logo are trademarks of Rockwell Software Inc. Logix5000, PLC-5, SLC-500 and Data Highway are trademarks of Allen Bradley Company LLC., all other trademarks are the property of their respective holders and are hereby acknowledged For more information on the latest pricing or a demonstration of any Rockwell Software package, please contact your local Rockwell Automation sales office or authorized AllenBradley distributor. For the very latest on Rockwell Software product development, visit our Web Site on the Internet at: http://www.software.rockwell.com WORLDWIDE REPRESENTATION Argentina, Australia, Austria, Bahrain, Belgium, Bolivia, Brazil, Bulgaria, Canada, Chile, China, Colombia, Costa Rica, Croatia Cyprus, Czech Republic, Denmark, Dominican Republic, Ecuador, Egypt, El Salvador, Finland, France, Germany, Ghana, Greece, Guatemala, Honduras, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kenya, Kuwait, Lebanon, Macao, Malaysia, Malta, Mauritius, Mexico, Morocco, Netherlands, New Zealand, Nigeria, Norway, Oman, Pakistan, Panama, Peru, Philippines, Poland, Portugal, Puerto Rico, Qatar, Romania, Russia, Saudi Arabia, Singapore, Slovakia, Slovenia, South Africa, Republic of South Korea, Spain, Sweden, Switzerland, Taiwan, Thailand, Trinidad, Tunisia, Turkey, United Arab Emirates, United Kingdom, United States, Uruguay, Venezuela, Vietnam, Zimbabwe 12/13/2005 Copyright © 2005 Rockwell Automation Inc., All Rights Reserved 12
© Copyright 2026 Paperzz