UV Basics: Calculating Dose/Fluence Terminology • • • • • Dose vs Fluence????? UV Transmission (UVT, UVT254 , UVT200) Biodosimetry Reduction Equivalent Fluence/Dose Validated Fluence/Dose Dose vs Fluence????? IUPAC Gold book Definitions: Dose “Energy or amount of photons absorbed per volume (or per mass) by an irradiated object during a particular exposure time.” Fluence “At a given point in space, the radiant energy incident on a small sphere divided by the cross-sectional area of that sphere”. UV Transmission 10mm Blank (DI Water) Eo Et UVTλ = …% UV Transmission LAMP UV Transmission LAMP 80% UV Transmission LAMP 80% 64% UV Transmission LAMP 80% 64% 51% UV Transmission LAMP 80% 64% 51% 41% UV Transmission LAMP 80% 64% 51% 41% Practical Calculation of UV Fluence (Quasi) Collimated Beam Lamp Radiometer Petri Dish Low Pressure (LP) Calculation Incident Energy (Fluence Rate) X Sample Transmission X Time = UV FLUENCE Medium Pressure Collimated Beam Methodology Lamp Emission Spectrum Action Spectrum 1.6 Absorbtion cm-1 1.4 1.2 1 0.8 0.6 0.4 0.2 0 200 210 220 230 240 250 260 270 280 290 300 Wavelength (nm) Action Spectra (DNA abs) Detector Sensitivity Spectral Transmission 14 10 8 6 4 2 0 200 220 240 260 Wavelength (nm) 280 300 320 Percentage Transmission Relative Sensitivity 12 100 90 80 70 60 50 40 30 20 10 0 200 210 220 230 240 250 260 270 280 290 300 Polychromatic (Medium Pressure) Collimated Beam Calculation Incident Energy (λ) x Action Spectrum (λ) X Matrix Transmission (λ) X Time Polychromatic Calculation to 253.7nm Log Inactivation MP LP Fluence Practical Surrogate Example T1UV Phage HER 1024 E.coli Host ATCC 11303 E.coli Host ATCC 700609 "Phage" by Dr Graham Beards - en:Image:Phage.jpg. Licensed under Public domain via Wikimedia Commons - Reactor Fluence/Dose Calculation (Biodosimetry) Reduction Equivalent Fluence / Dose Collimated Beam Surrogate Reduction UV Reactor Reduction Equivalent Fluence Practical Considerations (Plate Counts) Practical Considerations (Plate Counts) 20-200 pfu Practical Considerations (Dilution Series) 1/10 1/10 1/10 1/10 Validated Fluence/Dose Validated Fluence/Dose Validation Uncertainty “an uncertainty term that accounts for error in measurements made during validation testing to develop the UV intensity setpoint(s) (for the UV Intensity Setpoint Approach) or dose-monitoring equation (for the Calculated Dose Approach).” (UVDGM 2006) Validated Fluence/Dose Validation Uncertainty “an uncertainty term that accounts for error in measurements made during validation testing to develop the UV intensity setpoint(s) (for the UV Intensity Setpoint Approach) or dose-monitoring equation (for the Calculated Dose Approach).” (UVDGM 2006) REF x Validation Factor = Validated Dose (Safety/Uncertainty)
© Copyright 2026 Paperzz