scil animal care company Aesculap Care and Maintenance 1. Manual Cleaning 2. Rinse 3. Drying 4. Lubricating 5. Function Check (USE DISTILLED WATER) An autoclave does not clean; it only sterilizes. (Once a month 1 drop) Do Not Use: Flash Sterilization Chemical Sterilization (1 second spray every sterilization) DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris Rinse thoroughly with distilled water to remove excess debris and harmful mineral deposits from tap water Remove battery prior to cleaning and sterilization DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris • DO NOT AUTOCLAVE wet instruments and attachments Rinse thoroughly with distilled water to remove excess debris and harmful mineral deposits from tap water Remove battery prior to cleaning and sterilization DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris DO NOT: Immerse in water Use nylon brush Remove all traces of blood/debris Rinse thoroughly with distilled water to remove excess debris and harmful mineral • Dry instruments with clean towel deposits from tap water Rinse thoroughly with distilled water to remove excess debris and harmful mineral deposits from tap water Rinse thoroughly with distilled water to remove excess debris and harmful mineral deposits from tap • Allow sufficient water time for internal compartments to dry (use canned air or compressed air if necessary Rinse thoroughly to remove excess with distilled water to moisture from remove excess debris internal gears) and harmful mineral deposits from tap water (Internal hinge pins) 6. Steam Sterilization • Check the triggers • Temp: for smooth 270°F/275°F @ 4 movement minutes. • Check the rotor for smooth movement • Minimum drying • Check the time: 20 minutes coupling for proper functioning • Do not use tap • Operate drill in water in steam clockwise/counter sterilization: tap clockwise direction water contains • Operate drill in minerals and low, medium, max other substances speed which can cause oxidation, pitting, and staining of the • Install battery instruments • Install tool • Verify tool is seated properly by • Use distilled water for steam pulling on the saw sterilization blade • Briefly run the • Wrapped TPLO saw at instruments maximum speed should be placed (low whistling in materials which sound heard at the will allow steam startup of TPLO is penetration and normal promote drying, • Remove battery such as autoclave before autoclaving bag, autoclavable paper, or muslim towels • Verify cap fully seats on the drill • Allow a distance of or TPLO saw at least 1” between • Verify cap is able instruments to to be removed permit steam without much circulation effort • Check levers on cap to confirm they • Do not overload sterilizer: spring back when Overloading will depressed then cause inadequate released sterilization and drying • Check the function of the attachment coupling by attaching to drill • Install tool (drill bit, saw blade, etc…) • If wraps or instruments are still wet after autoclaving, increase the drying time • Position the • Verify tool is instruments and seated properly by attachments in the pulling on the tool standing position during autoclaving • Briefly run the drill if possible. This at maximum speed will allow built-up in clockwise and fluid to drain out of counter clockwise the tool. mode. The gears should move smoothly without resistance Example: Rinse thoroughly with distilled water to remove excess debris and harmful mineral deposits from tap water • Batteries should be left in charger if used daily • Batteries should be removed from charger if not being used for an extended period of time (one week or more) scil animal care company • 151 N Greenleaf St. Gurnee, IL 60031 • P: 877.724.5838 • F: 847.223.3374 • www.scilvet.com
© Copyright 2025 Paperzz