Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions 2 | Smart control Smart control | 3 Savings have seldom felt so good. With Climotion, you can achieve optimized climate control in your buildings. We create a very comforComfort Efficiency table atmosphere based on specific individual room requirements while simultaneously reducing energy costs Sustainability by up to 30 percent on average. Benefit from Climotion in three ways: Energy consumption is lowered, comfort is increased and CO2 emissions are reduced noticeably. Be one step ahead! Our innovative control for HVAC systems improves room comfort and increases energy efficiency. Thanks to intelligent measurement and control technology based on carefully adjusted sensors, air is distributed throughout the entire room. The comfortable result is a uniform temperature distribution without air layers. High temperatures under the ceiling created by rising air no longer occur. Rapid air movement in the vicinity of windows and exterior walls is not felt either. With Climotion you quickly create a comfortable atmosphere in your building without any changes to the building’s substance while simultaneously realizing significant energy savings. It‘s simple but effective! The benefits are in the air: u Energy cost savings of 30 percent on average, depending on the building up to 70 percent are possible u Reduction of CO2 emissions u Comfortable and healthy room climate u Low investment for retrofitting u Lower construction costs for new buildings u Greater architectural design freedom u Lower maintenance and repair costs u Optimal mixing of incoming air with room air u No pockets with high levels of humidity and pollutants 4 | Better climate by Climotion Better climate by Climotion | 5 The perfect working environment begins with the perfect room climate. Whether a modern office building, production facility, indoor swimming pool or cultural facility – regardless of the building concerned, the HVAC system plays an increasingly important role. At all times of the year, it provides comfortable temperatures despite the weather, internal heat generation (via body heat and electrical equipment) and makes it pleasant to stay in buildings. Furthermore, a good building climate has a beneficial effect not only on the occupants, but also on the building’s substance, the useful life of exhibits, equipment, machines and the quality of products. Energy efficiency in the future. Large areas of commercial buildings are already air-conditioned today and the trend is growing. Existing buildings are being retrofitted and new buildings without air-conditioning and ventilation systems are the exception. Studies project a steady increase in the energy demand for air-conditioning and ventilation in commercial buildings; this alone will result in a major increase in CO2 emissions. Owners face the challenge of operating buildings as efficiently as possible, keeping costs for operation and energy low and satisfying the comfort requirements of the building’s occupants. This is where our innovative Climotion control technology helps. In addition to significant energy cost savings, this technology simultaneously ensures a uniform temperature distribution without the adverse aspects of drafts. A person breathes approx. 15 kg of air daily, 90 percent of it in closed 15 kg rooms. After all, we spend the majority of our lives in buildings. Whether we feel comfortable there and would actually like to stay there for an extended period thus ultimately depends on the climatic conditions experienced. 6 | Reduce consumption, increase comfort Reduce consumption, increase comfort | 7 No. 1 Buildings are the number 1 energy consumer since they account for 30 percent of the world’s demand for energy. With Climotion, we achieve, on average, energy cost savings of 40 percent and in this way contribute to the energy efficiency of buildings. Optimal conditions in every corner. A comfortable room temperature and good air quali- must be cooled in the summer and heated in the tive algorithm expands the capability of the HVAC recirculated air or the amount of humidification is ty are the prerequisites for high visitor and occupant winter. This not only requires complex equipment, control system through incorporation of a software regulated automatically. While conventional HVAC satisfaction not only in offices, schools or swimming but also results in high energy costs. If building module to create an intelligent control. It guarantees systems cause drafts as a consequence of the high facilities, but in enclosed facilities of any kind. Fre- occupants are not satisfied, additional personnel optimal mixing of the incoming air with the room air velocities of the incoming and outgoing air, distribu- quently, however, despite major efforts it is not pos- costs and financial outlays result, and energy and and ensures a uniform distribution through slow air tion of air on the basis of the Climotion control prin- sible to control the temperature, humidity, air flow operating costs increase further. flow. The desired air quality, humidity and tempera- ciple ensures slow circulation of air at uniform air and air quality such that a comfortable climate is ture are specified for each ventilation zone and are velocities of approx. 0.1 m/s throughout the entire found in all rooms. subsequently monitored continuously. room. Uniform distribution of air prevents high tem- Amazingly simple. The Climotion approach With conventional HVAC technology, fresh air is fre- to efficiency. quently distributed unevenly in a room. Pockets form peratures under the ceiling or at windows as well as The HVAC systems are controlled on the basis of the uncomfortable drafts. This uniform distribution also measured values. If the air conditions deviate from prevents local buildup of pollutants and reduces the with different temperatures and higher concentra- With our Climotion system, this is all relegated to the the set values, Climotion adjusts the fan speeds as levels of CO2 and volatile organic compounds. For tions of pollutants; window fronts radiate heat and past, since we create an optimal climate for commer- well as the temperature of the incoming air automati- this purpose, the quality of the air is measured con- drafts occur. Complaints increase, the comfort level cial buildings with impressive comfort and efficiency cally and corrects temperature differences by con- tinuously and introduction of fresh air is adjusted decreases and performance suffers. In addition, a effects on the basis of individual requirements! In trolling the air dampers. When there are changes in on the basis of the measured values. relatively large amount of fresh air is needed, which buildings with a 1-duct or 2-duct system, our innova- air quality or humidity, the ratio of outside air to 8 | So easy: Climotion So easy: Climotion | 9 Our secret. The right control. Compared to conventional ventilation systems, the use of Climotion technology reduces energy costs It has been verified that a by, on average, 30 percent by saving the energy good climate in the room used to operate HVAC systems and to heat or cool increases satisfaction and fresh air. The better mixing of incoming air and performance. An optimal room air allows introduction of air with a greater temperature and a low CO2 level also have a beneficial temperature spread into the room. This means that effect on health. overall a smaller amount of air is needed to introduce the same amount of energy into the room. For example, decreasing the volumetric air flow by one-half reduces pressure drops in the entire HVAC system to one-quarter and the power consumption of fans to one-eighth of the previous costs. In addition, temperature stratification in the room is minimized to a difference of max. 1 K over a room height of 10 meters. Transmission heat loss resulting from high temperatures at the ceiling in the summer or cold regions near the floor in the winter are eliminated entirely. This reduces the amount of heat energy needed and assures uniform, comfortable temperatures throughout the room. The desired climate is quickly achieved in the room through continuous adjustment. Unnecessary overshoot of actual values is prevented, this reduces the number of heating and cooling cycles needed. This means that the heating and cooling capacities needed can be reduced, which extends the life of the HVAC system. Building owners benefit additionally from lower maintenance costs. Climotion reduces the overall amount of recirculated air, filters need to be replaced, registers cleaned and sensors checked less frequently. Saving energy. Improving comfort. Easily retrofitted without great expense. Climotion can be retrofitted to all HVAC systems Regardless of the building, a modern HVAC system One system, but many benefits for you. must satisfy two critical requirements today. On are reduced significantly. Moreover, exterior that incorporate outside air. Depending on their walls no longer feel as cold and uncomfortable suitability, existing volumetric flow controllers may the one hand, it must provide a comfortable room By improving the control of temperature, humidity air drafts are eliminated. In addition, the noise continue to be used or they may be replaced by air climate throughout the year; on the other, it must and air quality parameters in conjunction with control that is so common with conventional air-con- dampers to implement the control strategy. Existing contribute to energy efficiency. With its patented on the basis of air pressure, a comfortable and fully ditioning systems is reduced. Climotion climate sensors are usedand missing sensors needed for control algorithm for central HVAC systems, Climo- programmable climate can be achieved at all times. control benefits not only people, but also sen- measuring air quality, humidity, temperature and tion optimizes energy costs and increases the sa- Good fresh air reaches every corner of the room, sitive exhibits, machines and equipment. They pressure are added. Finally, the new control is loa- tisfaction of employees with the climate control temperatures remain constant and are perceived as are uniformly surrounded with the required air ded into the the HVAC system’s existing controller in buildings. comfortable everywhere. Pockets of pollution are temperature and humidity, which protects and programmed. prevented, and cold air flows along glass façades them from damage. 10 | Technical requirements Technical requirements | 11 It all depends on the right mixture. Our Innovative duct system achieves energy savings 70 % of up to 70 percent in existing buildings and reduces the construction costs for heating, ventilation and air-conditioning (HVAC) in new buildings. How intelligent efficiency can be – duct. When there are different temperatures in the the Climotion duct system. ducts, fresh air is supplied to each of the definedroom zones via a continuous damper only by the duct The Climotion duct system was developed to provide that is the most appropriate for achieving the value efficient and comfortable air conditioning of new set for the desired room temperature. If only little buildings. It makes HVAC energy savings of up to 70 heating or cooling is needed, the damper switches to percent possible. With this system, the optimal air the small duct. As the need drops, one duct can be volume for the building is provided by a central sys- closed completely. tem through two ducts, neither of which is strictly a hot air or cold air duct. The air flow rates and tem- Achieve more with less. peratures are determined on an as-needed basis for both ducts and are adjusted continuously. Here, the Our 2-duct system offers numerous advantages two supply air ducts have a ratio of ⅓ to ⅔. When over a conventional 1-duct system with an additive the heating is on, for instance, the entire building is heating and cooling system. Neither separate heating supplied by only one duct or both ducts, depending and cooling water systems nor additive heating and on the load. When full-load cooling is needed, both cooling components are needed in the building. This ducts supply cool air; for partial-load cooling, air is translates not only into lower HVAC investment costs supplied by either the ⅓-duct or the ⅔-duct. in the building, but also lower maintenance and operating costs. In addition, safety and security are For instance, both ducts are used for cooling in the increased, since water damage from leaks is a thing summer and heating in the winter, in transitional of the past. By eliminating radiators and ceiling seasons, there is either a warm-air duct or a cool-air panels, you gain space for more efficient utilization. 12 | Climotion: Ideal for existing and new buildings Climotion: Ideal for existing and new buildings | 13 We optimize. You benefit. Ohne Climotion Climotion Solution Ohne Climotion Climotion Duct System Ideal for existing buildings with 1-duct systems Ideal for new construction for even more savings Lower energy costs: u On average, 30 percent lower energy costs for HVAC u Minimum temperature stratification even in u Additional energy savings of up to 70 percent possible rooms with high ceilings, and thus reduced transmission heat losses Maximum comfort in rooms: u A better climate in the room as the result of u Individualized single-room/zone control by less incoming air and the elimination of ascen- the HVAC system through elimination of static ding warm air, descending cool air, pockets of heating, cooling ceiling panels, concrete air with a different temperature/higher con- coreactivation etc. centration of pollutants u Maintenance of set temperature/humidity values when the room load changes frequently u Reduction of the noise associated with HVAC systems (less recirculation of air) u Simplified routing of supply/exhaust air ducts with positioning of outlets anywhere and/or elimination of conventional supply air outlets with their induction effect u Modification of ceiling discharge, fewer air outlets in the ceiling, improved esthetics Lower construction and operating costs: u In existing 2-duct systems, the conversion is ventilation and air-conditioning due to lower 2 control dampers (this means lower conver- investment costs than for a conventional 1-duct sion costs, less background noise, conversion Climatic fluctuations in Europe from January to December are great. In winter, temperatures sometimes reach -30 °C and on hot summer day they can even reach 40 °C. In order to have an optimal climate for 22 °C work in offices and large production facilities (22 °C room temperature), a flexible and efficient HVAC system is needed. With Climotion, you lower energy consumption while simultaneously reducing construction costs and raising the comfort level in rooms. Regardless of whether an existing building or new construction. u Reduction of construction costs for heating, limited largely to replacing the mixing box with possible during operation) u Retrofitting of existing systems (1- and 2-duct systems) with, on average, 2 years 22° payback time system with additive heating/cooling systems u Greater reliability, since heating and cooling water systems are not needed in the building u Higher simultaneity factor through use of zone damper control u Reduced maintenance expenses, since heating and cooling systems are eliminated 14 | Climotion and its applications Climotion and its applications | 15 Global application, local implementation. We provide the optimal climate after considering the special aspects and challenges of your branch of industry and your building. Our certified partner companies provide onsite assistance. You also benefit from the extensive know-how associated with the Bosch brand. The Climotion algorithm is available for different makes of controllers as a preprogrammed module. This makes retrofitting of existing buildings easy and generally quite cost-effective, often resulting in short payback. It is only necessary to replace existing volumetric flow controllers with control dampers, install any additional sensors required and retrofit the HVAC controller with the Climotion module. Exact programming is provided by our experienced partners during commissioning. We assist planning and engineering offices with implementation of Climotion in buildings by providing appropriate tools and personal support. To date, Climotion has been installed in more than 2,000 HVAC systems worldwide. When will you add your name to the list? One system for almost all types of buildings: u Production facilities and shops, logistics centers u Administration and office buildings u Museums, libraries and churches u Airports u Hotels, restaurants, cafeterias u Conference and exhibition halls u Theaters, concert halls, movie theaters u Schools and universities, lecture halls u Sports facilities, multipurpose halls, fitness centers u Ice-skating rinks u Indoor swimming pools, water parks, spas u Arenas and stadiums u Radio and TV stations/studios Benefit from the experience of our certified partners. An overview of all companies can be found on our Internet page: www.climotion.com u Shopping centers and supermarkets u Greenhouses Climate Technology Email: [email protected] www.climotion.com Bosch Energy and Building Solutions GmbH Mittlerer Pfad 4 70499 Stuttgart, Germany Phone: +49 711 811-26262 Fax: +49 711 811-5183819 Bosch Energy and Building Solutions GmbH Munich branch Gutenbergstraße 8 85737 Ismaning, Germany Phone: +49 89 219094-0 Fax: +49 89 219094-130 Robert Bosch UK Holdings Limited P.O.Box 98; Broadwater Park North Orbital Road Middlesex UB9 5HJ Denham Phone: +44 1895 83-8577 www.climotion.co.uk Robert Bosch AG Bosch Energy and Building Solutions Derffl ingerstraße 15 4020 Linz, Austria Phone: +43 732 7667-733 Fax: +43 732 7667-781 www.climotion.at Robert Bosch AG Bosch Energy and Building Solutions Post offi ce box 264 4501 Solothurn, Suisse Visitors address: Luterbachstrasse 10 4528 Zuchwil, Suisse Phone: +41 32 686-5780 Fax: +41 32 686-7204 www.climotion.ch Printed in Germany 100 % chlorine free paper
© Copyright 2026 Paperzz