www.martekpower.com 36 PVI series 40 to 110 watts Features: • Universal AC Input; 90-264 • Single, Dual and Triple Outputs • Modified and Custom Designs Available Input Characteristics Ideally Suited For: • Disk and Tape Drives • Telephone Switches • Computing Input Voltage: Efficiency Input Frequency: Hold Up Time: 90-264 VAC 75% typical 47-63 Hz (consult factory for >63 Hz) 20 mSec at nominal input and full load Output Characteristics Line Regulation: Load Regulation: +/-0.5% typical Main Output : +/-1% from 10% to 100% load Auxiliary Outputs: +/-3.5% from 10% to 100% load Ripple and Noise: 1% pk-pk of Vout Transient Response (50% load change) 2% maximum deviation; outputs return to regulation within 1.0 mSec maximum Overload Protection: Power limiting with auto recovery at 125% rated load Short Circuit Protection: Continuous without damage; auto recovery Over Voltage Protection: Main output only Environmental Characteristics Operating Temperature Range: Storage Temperature Range: Temperature Coefficient: Humidity: Reliability (MTBF per Mil-HDBK-217): Cooling: 0ºC to 50ºC continuous duty full rating. Derate linearly to 50% of full rating at 71ºC -20ºC to +85ºC 0.02%/degree C Up to 95% non-condensing >100,000 hours fan cooling required. Consult factory General Characteristics Isolation (Input to Output): Size: Weight: Agency Approvals 3750 VAC min. See case drawings Varies by model, consult factory UL, CUL, DEMKO and CE mark >>1 Les Auberges 69770 Montrottier France Tel. 33 (0)1 69 88 83 97 Fax: +33 (0) 1 69 88 80 37 [email protected] www.martekpower.com Available Models Main Output VDC/Amps +5 / 3.0 +5/ 3.0 +5/ 5.0 +5/6.0 +5/8.0 +5/8.0 +5/8.0 +5/10.0 +5/10.0 +5/10.0 +5/10.0 +5/10.0 +5/10.0 +5/14.0 +5/10.0 +5/10.0 Model PVI-40-21TA PVI-50-21TA PVI-65-30X PVI-80-21 PVI-80-30 PVI-80-34 PVI-80-37 PVI-90-30 PVI-90-32 PVI-90-34 PVI-90-40 PVI-90-43 PVI-90-44 PVI-110-31T PVI-110-32 PVI-110-34 Auxiliary 1 Output Current VDC/Amps/Peak Amps +12/2.02/4.5 +12/3.0/5.5 +12/2.0/— +12/6.0/13.0 +12/2.0/4.0 +15/1.5/3.0 +12/0.5/1.0 +12/3.0/4.0 +24/1.5/3.0 +15/2.0/4.0 +12/2.0/3.0 +15/2.5/4.0 +12/3.0/4.0 +12/3.0/3.0 +24/1.5/3.0 +15/2.0/4.0 Auxiliary 2 Output Current VDC/Amps Auxiliary 3 Output Current VDC/Amps -12/1.5 -12/2.0 -15/1.5 -5.2/4.0 -12/1.5 -12/1.5 -15/1.5 -12/1.5 -15/1.5 +12/1.5 -12/0.5 -12/1.5 -15/1.5 -5/1.5 -5/1.5 -12/1.0 Outline Drawing PVI50 PVI65 PVI80 4.8 122.00 4.80 122.00 4.55 115.57 3.94 100.00 3.15 80.00 3.00 76.20 2.55 64.77 3.94 100.00 3.15 80.00 .C.B. MOUNTING Ø4.0 4 PLACES P.C.B. MOUNTING Ø4.0 4 PLACES P.C.B. MOUNTING Ø4.0 4 PLACES 0.06 1.60 1.75 44.50 0.06 1.60 5.00 127.00 1.2 30.5 6.2 157.50 6.3 160.00 PVI90 PVI110 Consult factory for pin outs PVI40 7.07 179.50 6.69 170.00 1.81 46.00 0.06 1.60 6.57 167.00 3.15 80.00 3.64 92,50 3.25 82.50 4.42 112.30 2.00 50.80 1.60 40.80 P.C.B. MOUNTING Ø4.0 4 PLACES P.C.B. MOUNTING Ø4.0 4 PLACES 0.06 1.60 7.99 203.00 2.32 59.00 P.C.B. MOUNTING Ø4.0 4 PLACES 0.06 1.60 7.46 189.50 1.69 43.00 0.06 1.60 1.2 29.5 7.00 177.80 All specifications are typical at 25 degrees C with nominal input voltage and full output unless otherwise noted. Specifications are subject to change without notice. All dimensions are typical. >>2 Les Auberges 69770 Montrottier France Tel. 33 (0)1 69 88 83 97 Fax: +33 (0) 1 69 88 80 37 [email protected]
© Copyright 2026 Paperzz