PVI 40-110 Watts AC-DC power supplies

www.martekpower.com
36
PVI series
40 to 110 watts
Features:
• Universal AC Input; 90-264
• Single, Dual and Triple Outputs
• Modified and Custom Designs
Available
Input Characteristics
Ideally Suited For:
• Disk and Tape Drives
• Telephone Switches
• Computing
Input Voltage:
Efficiency
Input Frequency:
Hold Up Time:
90-264 VAC
75% typical
47-63 Hz (consult factory for >63 Hz)
20 mSec at nominal input and full load
Output Characteristics
Line Regulation:
Load Regulation:
+/-0.5% typical
Main Output : +/-1% from 10% to 100% load
Auxiliary Outputs: +/-3.5% from 10% to 100% load
Ripple and Noise:
1% pk-pk of Vout
Transient Response (50% load change) 2% maximum deviation; outputs return to
regulation within 1.0 mSec maximum
Overload Protection:
Power limiting with auto recovery at 125%
rated load
Short Circuit Protection:
Continuous without damage; auto recovery
Over Voltage Protection:
Main output only
Environmental Characteristics
Operating Temperature Range:
Storage Temperature Range:
Temperature Coefficient:
Humidity:
Reliability (MTBF per Mil-HDBK-217):
Cooling:
0ºC to 50ºC continuous duty full rating. Derate
linearly to 50% of full rating at 71ºC
-20ºC to +85ºC
0.02%/degree C
Up to 95% non-condensing
>100,000 hours
fan cooling required. Consult factory
General Characteristics
Isolation (Input to Output):
Size:
Weight:
Agency Approvals
3750 VAC min.
See case drawings
Varies by model, consult factory
UL, CUL, DEMKO and CE mark
>>1
Les Auberges „ 69770 Montrottier „ France „ Tel. 33 (0)1 69 88 83 97 „ Fax: +33 (0) 1 69 88 80 37 „ [email protected]
www.martekpower.com
Available Models
Main
Output
VDC/Amps
+5 / 3.0
+5/ 3.0
+5/ 5.0
+5/6.0
+5/8.0
+5/8.0
+5/8.0
+5/10.0
+5/10.0
+5/10.0
+5/10.0
+5/10.0
+5/10.0
+5/14.0
+5/10.0
+5/10.0
Model
PVI-40-21TA
PVI-50-21TA
PVI-65-30X
PVI-80-21
PVI-80-30
PVI-80-34
PVI-80-37
PVI-90-30
PVI-90-32
PVI-90-34
PVI-90-40
PVI-90-43
PVI-90-44
PVI-110-31T
PVI-110-32
PVI-110-34
Auxiliary 1
Output Current
VDC/Amps/Peak Amps
+12/2.02/4.5
+12/3.0/5.5
+12/2.0/—
+12/6.0/13.0
+12/2.0/4.0
+15/1.5/3.0
+12/0.5/1.0
+12/3.0/4.0
+24/1.5/3.0
+15/2.0/4.0
+12/2.0/3.0
+15/2.5/4.0
+12/3.0/4.0
+12/3.0/3.0
+24/1.5/3.0
+15/2.0/4.0
Auxiliary 2
Output Current
VDC/Amps
Auxiliary 3
Output Current
VDC/Amps
-12/1.5
-12/2.0
-15/1.5
-5.2/4.0
-12/1.5
-12/1.5
-15/1.5
-12/1.5
-15/1.5
+12/1.5
-12/0.5
-12/1.5
-15/1.5
-5/1.5
-5/1.5
-12/1.0
Outline Drawing
PVI50
PVI65
PVI80
4.8
122.00
4.80
122.00
4.55
115.57
3.94
100.00
3.15
80.00
3.00
76.20
2.55
64.77
3.94
100.00
3.15
80.00
.C.B. MOUNTING Ø4.0 4 PLACES
P.C.B. MOUNTING Ø4.0 4 PLACES
P.C.B. MOUNTING Ø4.0 4 PLACES
0.06
1.60
1.75
44.50
0.06
1.60
5.00
127.00
1.2
30.5
6.2
157.50
6.3
160.00
PVI90
PVI110
Consult factory
for pin outs
PVI40
7.07
179.50
6.69
170.00
1.81
46.00
0.06
1.60
6.57
167.00
3.15
80.00
3.64
92,50
3.25
82.50
4.42
112.30
2.00
50.80
1.60
40.80
P.C.B. MOUNTING Ø4.0 4 PLACES
P.C.B. MOUNTING Ø4.0 4 PLACES
0.06
1.60
7.99
203.00
2.32
59.00
P.C.B. MOUNTING Ø4.0 4 PLACES
0.06
1.60
7.46
189.50
1.69
43.00
0.06
1.60
1.2
29.5
7.00
177.80
All specifications are typical at 25 degrees C with nominal input voltage and full output unless
otherwise noted. Specifications are subject to change without notice. All dimensions are typical.
>>2
Les Auberges „ 69770 Montrottier „ France „ Tel. 33 (0)1 69 88 83 97 „ Fax: +33 (0) 1 69 88 80 37 „ [email protected]