NALCO Champion Dilley Texas Tank 8 Inspection Date of Inspection: 7-14-2016 Inspector: Curtis Stewart API 653 #973 Tank Built: 2011 Manufacturer: Palmer of Texas Capacity: 210 BBL Serial Number: #25817 Standard: API 12F Modified API Monogram 0067 Pressure: 16oz Materials: Floor ¼’’ A36. Shell 3/16’’ A-36 Deck(Roof) 3/16” A-36 Interior: Interior is on good condition. Coating has isolated failed areas. UT readings of the floor found a general metal loss of 10 to 24 mils based on a original 0.250’’ datum plate thickness Shell: Tank has failed coating in the bottom 6-12 inches. UT of this area found loss of 2-4 mils based on the datum plate thickness of 3/16’’ Recommended: Interior: Tank liner is in good condition. Isolated areas of lining failure will require repair. Liner type has not yet been discovered and lining should not be repaired unless the lining type is found. Repair with another manufacturer system or with the incorrect Themic system can result in failure and accelerated corrosion of the repaired area(s). Exterior: Blast 2 feet of the bottom course and install new approved atmospheric coating system. Spot blast and repair failed paint with approved atmospheric paint system. After blasting the outside the bottom corner (chime) weld should be inspected for corrosion loss and acceptability of filet size. Tank Bottom & Containment: Tanks are setting on 6-inch-thick concrete pavers. These go under the tank to support the bottom. The containment is steel and setting on the ground. The condition of the steel containment under the concrete pavers cannot be determined. If the tanks are to be returned to service it is recommended the tanks and concrete pavers be removed and the steel inspected to determine continued service. The condition of the steel coating is poor. The containment would require relining with a suitable external UV resistant coating. Deck(Roof): The tank thief hatch should have the gaskets replaced and the pressure vacuum springs changed to a chemical resistant material. The threaded connections should be removed and the threads evaluated. During coating the threads should be coated and inspected prior to re-installing new connections. Pictures Tank 8 Dilley Texas Floor east quarter Floor south quarter Floor west quarter Floor north quarter. Note lining failure on shell left of center weld Tank roof and shell Tank roof and shell west half of tank 3-inch threaded nozzle next to manway. Corrosion on threads. 4-Inch threaded nozzle. Note staining from thread corrosion. Shell and containment corrosion from water setting against steel and coating failure Shell corrosion near manway Shell corrosion at 3-inch threaded nozzle and manway Shell corrosion and concrete support pavers Shell and containment corrosion on west side of tank
© Copyright 2026 Paperzz