Protan Exposed Membrane Roof

Te c h n i c a l D r a w i n g s
Protecting values
Protan Exposed Membrane Roof
Protan Exposed Membrane Roof
Drawing No.: Name:
Page:
40-10-01
40-10-02
Standard overlap – insulated. ................................................. 5
Standard overlap – uninsulated............................................... 5
40-15-01
S e c r e t F i x S y s t e m .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
40-20-01
40-20-02
40-20-03
40-20-04
40-20-05
40-20-06
40-20-07
40-20-08
40-20-09
40-20-10
40-20-11
40-20-12
P a r a p e t w i t h s e c r e t f i x p o c k e t + h i g h w a l l t e r m i n a t i o n d e t a i l .. . . . . . . . 7
P a r a p e t w i t h s e c r e t f i x s t r i p d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Parapet with secret fix pocket + low wall termination detail.......... 9
W a t e r c h e c k d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0
Upstand termination with wall counter-flashing detail. ............... 10
Upstand termination bar detail.............................................. 11
Edge trim detail. ................................................................ 11
Valley flashing detail . ........................................................ 12
Roof light kerb flashing detail with secret fix pocket. ................ 13
R o o f l i g h t k e r b f l a s h i n g d e t a i l w i t h s e c r e t f i x s t r i p .. . . . . . . . . . . . . . . . . . . 1 4
Upstand termination with compression counter flashing detail..... 15
I n s u l a t e d p a r a p e t w i t h s e c r e t f i x p o c k e t .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5
40-25-01
40-25-02
40-25-03
Internal gutter detail – narrow girth. ...................................... 16
I n t e r n a l g u t t e r d e t a i l – w i d e g i r t h w i t h s e c r e t f i x p o c k e t .. . . . . . . . . . . . 1 5
R i d g e f l a s h i n g d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7
40-30-01
40-30-02
40-30-03
40-30-04
40-30-05
Drainage
Drainage
Drainage
Drainage
Drainage
40-35-01
40-35-02
P i p e f l a s h i n g d e t a i l – c o n t i n u o u s .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1
P i p e f l a s h i n g d e t a i l – c l o s e d .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1
40-40-01
E x p a n s i o n j o i n t d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2
40-45-02
Walkway – normal duty........................................................ 23
40-50-01
40-50-02
Omega architectural profile.................................................. 24
T r i a n g u l a r a r c h i t e c t u r a l p r o f i l e .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4
40-55-01
40-55-02
40-55-03
40-55-04
Vacuum
Vacuum
Vacuum
Vacuum
40-60-01
A d h e r e d R o o f i n g S y s t e m – g e n e r a l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 8
–
–
–
–
–
o u t l e t w i t h f a c t o r y a t t a c h e d P r o t a n M e m b r a n e .. . . . . . . . . .
c l a m p r i n g o u t l e t .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
syphonic outlet a). ..............................................
syphonic outlet b). ..............................................
through wall outlet. .............................................
Roofing
Roofing
Roofing
Roofing
System
System
System
System
–
–
–
–
general.........................................
p a r a p e t d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vacuum vent detail..........................
o u t l e t d e t a i l .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
18
19
19
20
26
26
27
27
3
S e p a ra t i o n l aye r s fo r P r o t a n P VC m e m b ra n e s
A separation layer/barrier between the roofing membrane and its underlying deck, is sometimes necessary to protect the
roofing material from chemical and/or mechanical influences.
The separation layer must be functional under all conditions that the roofing membrane might experience during its entire
lifetime.
Migration barriers are installed between two layers to avoid chemical interaction between them.
Sliding layers are installed between two layers to prevent friction between them.
Levelling layers are installed between two layers mainly for aesthetic reasons.
Protection layers are installed on top of the membrane mainly to protect it from mechanical stress etc.
(Protan recommends a layer of PVC 1,2-2,0mm, alternatively a very thick polypropylene fleece > 300g/m2.)
Table: Separation layers for Protan PVC
Unde rla y ing de c k
P ro tan P V C -m em b ran e
Old bitumen roofs
Protan EX
Protan EX has a 140 g/m2
polypropylene fleece migration barrier laminated
on the reverse side
Protan SE
Protan SE requires a separate migration
barrier installed on top of the bitumen surface
to avoid migration.
Protan recommends:
Fibertex F2B, 140g/m2 polypropylene, supplied
by Protan AS
EPS/XPS-insulation
Protan EXG
Protan EXG has a 60g/m2 glass
fleece migration barrier laminated
on the reverse side
Protan SE
Protan SE requires a separate migration
barrier installed on top of the bitumen surface
to avoid migration.
Protan recommends:
Glass fleece 50g/m2 supplied by Protan AS
Bases of smooth concrete
or light weight concrete
Protan SE
Protan SE requires a sliding/levelling layer installed on top of the concrete deck.
Protan recommends:
Fibertex F4M 300 g/m2 PP, supplied by Protan AS.
Note! Polyester felt must not be used on concrete!
Timber decks
As for old bitumen roofs
Rubber, such as underlying
blocks, mats, packing etc.
As for old bitumen roofs
Old mechanically fastened
polymeric membrane
As for old bitumen roofs (140g/m˝ polypropylene fleece/geo-textile).
Existing membrane to be slit at perimeters, change of angle, fixing lines etc to
alleviate any stress/tension transfer to new fasteners and to assist in
the drying out of any trapped moisture
Old gravel ballasted
polymeric membrane
Lubricated roofs
Where possible the existing membrane should be removed,
if this is not feasible, the existing membrane should be slit at perimeters, change of angle, fixing points etc
to alleviate any stress/tension
transfer to new fasteners and to assist in
the drying out of any trapped moisture
Lubricated roofs should be evaluated, please contact Protan Technical Services
Please contact Protan for a list of other tested and approved products for the use as separation layers.
4
Pr o tan Ex pos ed M em br ane R oof
Standard over lap – insula ted
Drawing No.:
Version No.:
Not to scale
40 -10 -01
02-2008
HEAT WELDED SEAM
PROTAN NON THERMAL
BRIDGING PLATE
PROTAN SE MEMBRANE
ALT. MIGRATION BARRIER
FASTENER
40mm
WELD
130mm Wide Overlap for
1M Wide Membrane
or
140mm Lap for 2M Wide Membrane
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
Standard over lap – uninsula ted
Drawing No.:
Version No.:
Not to scale
40-10-02
02-2008
METAL PLATE
HEAT WELDED SEAM
FASTENER
PROTAN SE MEMBRANE
GEOTEXTILE
(SUBJECT TO REQUIREMENTS)
40mm
WELD
SUPPORTING DECK
e.g. TIMBER
130mm Wide Overlap for
1M Wide Membrane
or
140mm Lap for 2M Wide Membrane
5
Pr o tan Ex pos ed M em br ane R oof
Secret Fix System
Drawing No.:
Version No.:
Not to scale
40-15-01
01-2004
ADJACENT ROLL OF PROTAN SE MEMBRANE
PROTAN SE MEMBRANE 2M WIDE
40mm SIDE WELD
100
mm
SID
EL
AP
NON THERMAL BRIDGING PLATE
AND FASTENER
SECRET FIX STRIP
FACTORY WELD
MIGRATION BARRIER
6
PROTAN SECRET FIX STRIPS
FACTORY WELDED ACROSS THE
ROLL WIDTH AT PRE-DESIGNED
CENTRES
Pr o tan Ex pos ed M em br ane R oof
Parapet with secret fix pocket
+ high wall ter mination detail
Drawing No.:
Version No.:
Not to scale
40-20-01
01-2004
METAL CAPPING
CONTINUOUS CLEAT
MECHANICALLY FASTENED
PROTAN SE MEMBRANE
METAL PLATE & FASTENER
SECRET FIX STRIP
AT MAXIMUM INTERVALS OF 400mm
HEAT WELDED SEAM
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
PROTAN SE MEMBRANE
FASTENER
HEAT WELDED SEAM
HEAT WELDED SEAM
ALT. MIGRATION BARRIER
NON THERMAL
BRIDGING PLATE
FASTENER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
7
Pr o tan Ex pos ed M em br ane R oof
Parapet with secret fix strip detail
Drawing No.:
Version No.:
Not to scale
40-20-02
02-2008
PROTAN SE MEMBRANE
WELDING CORD
PROTAN SE/FP SECRET FIX STRIP
STRIP 130mm WIDE
PROTAN METAL BAR MECHANICALLY FASTENED
HEAT WELDED SEAMS
PROTAN SE MEMBRANE
ALT. MIGRATION BARRIER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
8
Pr o tan Ex pos ed M em br ane R oof
Parapet with secret fix pocket
+ low wall ter mination detail
Drawing No.:
Version No.:
Not to scale
40-20-03
01-2004
PVC COATED METAL (TRIM 150mm OR DEEPER TO BE FACE FIXED)
HEAT WELDED SEAM
COUNTERSUNK
FASTENER
HEAT WELDED SEAM
PROTAN SE MEMBRANE
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
FASTENER
HEAT WELDED SEAMS
PROTAN NON THERMAL
BRIDGING PLATE
FASTENER
ALT. MIGRATION BARRIER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
9
Pr o tan Ex pos ed M em br ane R oof
Wa t e r c h e c k d e t a i l
Drawing No.:
Version No.:
Not to scale
40-20-04
01-2004
COATED METAL
COVER FLASHING
PROTAN NON THERMAL
BRIDGING PLATE
FASTENER
PROTAN SE MEMBRANE
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
FASTENER
HEAT WELDED SEAMS
OPTIONAL MIGRATION BARRIER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
Upstand ter mination with wall
counter-flashing detail
Drawing No.:
Version No.:
Not to scale
40-20-05
01-2004
WIND BARRIER
CLADDING
SEALANT
CLADDING FASTENER WITH WEATHERPROOF WASHER
CLADDING DRIP RAIL
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
FASTENER
PROTAN NON THERMAL
BRIDGING PLATE
HEAT WELDED SEAMS
FASTENER
PROTAN SE MEMBRANE
OPTIONAL MIGR. BARRIER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
10
Pr o tan Ex pos ed M em br ane R oof
Upstand termination bar detail
Drawing No.:
Version No.:
Not to scale
40-20-06
01-2004
SEALANT
COUNTERFLASHING
METAL PLATE
FASTENER
PROTAN SE MEMBRANE
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
PROTAN SE MEMBRANE
FASTENER
PROTAN NON THERMAL
BRIDGING PLATE
HEAT WELDED SEAMS
ALT. MIGR. BARRIER
FASTENER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
Edge trim detail
Drawing No.:
Version No.:
Not to scale
40-20-07
01-2004
PVC OR FPO COATED METAL (TRIM 150mm OR DEEPER TO BE FACE FIXED)
HEAT WELDED SEAM
COUNTERSUNK
FASTENER
HEAT WELDED SEAMS
NON THERMAL
BRIDGING PLATE
ALT. MIGRATION BARRIER
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
11
Pr o tan Ex pos ed M em br ane R oof
Va l l e y f l a s h i n g d e t a i l
Drawing No.:
Version No.:
Not to scale
40-20-08
02-2008
PROTAN SE MEMBRANE
HEAT WELDED SEAM
NON THERMAL
BRIDGING PLATE
FASTENER
PROTAN SECRET
FIX STRIP
HEAT WELDED SEAM
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
12
Pr o tan Ex pos ed M em br ane R oof
Roof light kerb flashing detail with
secret fix pocket
Drawing No.:
Version No.:
Not to scale
40-20-09
01-2004
PROTAN SEALANT
ALT.1 PROTAN G MEMBRANE
FULLY BONDED TO KERB / ALT.2 PROTAN SE LOOSELY INSTALLED
PROTAN STEEL BAR AND FASTENER
PROTAN SECRET FIX POCKET
HEAT WELDED SEAMS
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
13
Pr o tan Ex pos ed M em br ane R oof
Roof light kerb flashing detail with
secret fix strip
Drawing No.:
Version No.:
Not to scale
40-20-10
01-2004
PROTAN SEALANT
ALT.1 PROTAN G MEMBRANE
FULLY BONDED TO KERB / ALT.2 PROTAN SE LOOSELY INSTALLED
PVC CORD
PROTAN STEEL BAR AND FASTENER
HEAT WELDED SEAMS
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
14
Pr o tan Ex pos ed M em br ane R oof
U p s t a n d t e r m i n a t i o n w i t h c o m p r e s s i o n counter flashing detail
Drawing No.:
Version No.:
Not to scale
40-20-11
01-2004
SEALANT
TERMINATION BAR FLASHING
FASTENER WITH WEATHERPROOF WASHER
PROTAN SE MEMBRANE
PROTAN SECRET FIX POCKET
PROTAN SE MEMBRANE
PROTAN METAL BAR
FASTENER
PROTAN NON THERMAL
BRIDGING PLATE
HEAT WELDED SEAMS
ALT. MIGRATION
BARRIER
870mm Max
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
Insula ted parapet with secret fix pocket
Drawing No.:
Version No.:
Not to scale
40-20-12
01-2004
PVC COATED METAL (TRIM 150mm OR DEEPER TO BE FACE FIXED)
HEAT WELDED SEAM
COUNTERSUNK
FASTENER
HEAT WELDED SEAM
ALT. MIGRATION BARRIER
PROTAN SE MEMBRANE
PROTAN SECRET FIX POCKET
PROTAN METAL BAR
PROTAN NON THERMAL
BRIDGING PLATE
HEAT WELDED SEAMS
ALT. MIGRATION BARRIER
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
15
Pr o tan Ex pos ed M em br ane R oof
Internal gutter detail – narrow gir th
Drawing No.:
Version No.:
Not to scale
40-25-01
01-2004
PROTAN SE MEMBRANE
HEAT WELDED SEAM
PROTAN G MEMBRANE
FULLY BONDED TO GUTTER
ROUND PLATE
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
PLYWOOD
ALT. MIGRATION BARRIER
I n t e r n a l g u t t e r d e t a i l – w i d e g i r t h w i t h secret fix pocket
Drawing No.:
Version No.:
Not to scale
40-25-02
01-2004
PROTAN SE MEMBRANE
METAL PLATE
FASTENER
HEAT WELDED SEAM
FLEECE
PROTAN SECRET FIX POCKET / STRIP
PROTAN SE MEMBRANE
HEAT WELDED SEAM
SUPPORTING DECK
FASTENER
PROTAN METAL BAR
16
130mm
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
Pr o tan Ex pos ed M em br ane R oof
Ridge flashing detail
Drawing No.:
Version No.:
Not to scale
40-25-03
02-2008
GALVANISED STEEL ANGLE
(0.7mm THICK, 100mm x 100mm)
GEOTEXTILE
PROTAN SE MEMBRANE
(MAXIMUM 1M WIDE)
NON THERMAL
BRIDGING PLATE
HEAT WELDED
SEAM
FASTENER
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
17
Pr o tan Ex pos ed M em br ane R oof
D r a i n a g e – o u t l e t w i t h f a c t o r y a t t a c h e d Protan Membrane
Drawing No.:
Version No.:
Not to scale
40-30-01
01-2004
LEAF GRATE
PROTAN G STRIP FACTORY
ATTACHED TO DRAIN FLANGE
STAINLESS STEEL
BODY
COUNTERSUNK FASTENER
PROTAN SE MEMBRANE
HEAT WELDED SEAM
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
Drainage – clamp ring outlet
Drawing No.:
Version No.:
Not to scale
40-30-02
02-2008
LEAF GRATE WITH CLAMP RING
COMPRESSION SEALANT
PROTAN G
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
18
Pr o tan Ex pos ed M em br ane R oof
Drainage –syphonic outlet a)
Drawing No.:
Version No.:
Not to scale
40-30-03
01-2004
HEAT WELDED SEAM
PVC COMPATIBLE BODY
COUNTERSUNK
FASTENER
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
Drainage – syphonic outlet b)
Drawing No.:
40-30-04
Version: 01-2004
Not to scale
HEAT WELDED SEAM
PVC COMPATIBLE BODY
COUNTERSUNK
FASTENER
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
19
Pr o tan Ex pos ed M em br ane R oof
Drainage - through wall outlet
Drawing No.:
Version No.:
Not to scale
40-30-05
01-2004
PROTAN SE MEMBRANE
PROTAN G FACTORY ATTACHED
TO DRAIN FLANGE
HEAT WELDED SEAM
COUNTERSUNK FASTENER
STAINLESS STEEL BODY
HEAT WELDED SEAM
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
20
Pr o tan Ex pos ed M em br ane R oof
Pipe flashing detail – continuous
Drawing No.:
Version No.:
Not to scale
40-35-01
01-2004
SEALANT
COMPRESSION CLIP
PLATE
(MINIMUM OF 4 PER PIPE
& MAXIMUM DISTANCE
OF 150mm BETWEEN
PLATES)
50mm WIDE HEAT
WELDED SEAM
PROTAN G MEMBRANE
HEAT WELDED SEAMS
PROTAN G MEMBRANE
FASTENER
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
Pipe flashing detail– closed
Drawing No.:
Version No.:
Not to scale
40-35-02
01-2004
PROTAN G MEMBRANE
HEAT WELDED LAP
PLATE
(MINIMUM OF 4 PER PIPE
& MAXIMUM DISTANCE
OF 150mm BETWEEN
PLATES)
PROTAN PREFABRICADTED SLEEVE
PROTAN G MEMBRANE
HEAT WELDED SEAMS
FASTENER
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
21
Pr o tan Ex pos ed M em br ane R oof
Expansion joint detail
Drawing No.:
Version No.:
Not to scale
40-40-01
02-2008
COMPRESSIBLE TUBE
PROTAN SE MEMBRANE COVER STRIP
NON THERMAL
BRIDGING PLATE
HEAT WELDED SEAM
PROTAN SE MEMBRANE
FASTENER
SUPPORTING DECK
EXPANSION JOINT
FILLER
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
22
Pr o tan Ex pos ed M em br ane R oof
Wa l k way – n o r m a l d u t y
Drawing No.:
Version No.:
Not to scale
40-45-02
01-2004
PROTAN GT WALKWAY
500mm OR 1000mm WIDE
DISCONTINIOUS HEAT WELDS
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
23
Pr o tan Ex pos ed M em br ane R oof
Omega architectural profile
Drawing No.:
Version No.:
Not to scale
40-50-01
01-2004
OMEGA PROFILE WELDED
TO ROOF MEMBRANE
PROTAN SE MEMBRANE
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
ALT. MIGRATION BARRIER
20
ł=9
14
40
24
Pr o tan Ex pos ed M em br ane R oof
Tr i a n g u l a r a r c h i t e c t u r a l p r o f i l e
Drawing No.:
Version No.:
Not to scale
40-50-02
01-2004
TRIANGLULAR PROFILE WELDED
TO ROOF MEMBRANE
PROTAN SE MEMBRANE
WELDING CORD
SUPPORTING DECK
VAPOUR CONTROL LAYER
INSULATION
50
55
MIGRATION BARRIER
55
25
Pr o tan Ex pos ed M em br ane R oof
Va c u u m R o o f i n g S y s t e m - g e n e r a l
Drawing No.:
Version No.:
Not to scale
40-55-01
01-2004
PROTAN SE
MIN. 50mm MINERALWOOL
VAPOR CONTROL LAYER
SUPPORTING DECK,
AIRTIGHT
Va c u u m R o o f i n g S y s t e m – p a r a p e t d e t a i l
Drawing No.:
Version No.:
Not to scale
40-55-02
01-2004
MIGRATION BARRIER BONDED TO SUBSTRATE AND WALL
PROTAN AIR-SEALING BAND
PROTAN SECRET FIX POCKET
FASTNER
PROTAN STEEL BAR
HEAT WELDED SEAM
PROTAN SE
MINERALWOOL
SUPPORTING DECK,
AIR TIGHT
POSSIBLE AIRLEAK
26
Pr o tan Ex pos ed M em br ane R oof
Va c u u m R o o f i n g S y s t e m –
vacuum vent detail
Drawing No.:
Version No.:
Not to scale
40-55-03
01-2004
VENT. COVER
VENT HAUSING
CLAMP RING
PROTAN PREFABRICATED DETAIL
HEAT WELDED SEAM
PROTAN SE
MINERAL WOOL
VAPOUR CONTROL LAYER
SUPPORTING DECK,
AIRTIGHT
Va c u u m R o o f i n g S y s t e m – o u t l e t d e t a i l
Drawing No.:
Version No.:
Not to scale
40-55-04
01-2004
CLAMP RING
PROTAN G
HEAT WELDED
SEAM
PROTAN SE
MINERAL WOOL
PVC WELDING CORD
PROTAN STEEL BAR
PROTAN AIR SEALING BAND
VAPOUR CONTROL LAYER
FASTNER
SUPPORTING DECK,
AIRTIGHT
27
Pr o tan Ex pos ed M em br ane R oof
Adhered Roofing System - general
Drawing No.:
Version No.:
Not to scale
40-60-01
01-2004
PROTAN GX
EXISTING BITUMEN ROOF LOAD BEARING
INSULATION
SUPPORTING DECK
28
Protan Protected Membrane Roof
Protan Roof Renovation
Protan Terraces and Balconies
Protan Exposed Membrane Roof
Protan Technical Drawings
Protan AS
P. O. Box 420 Brakerøya - N-3002 Drammen - Norway
Telephone +47 32 22 16 00 - Fax +47 32 22 17 00
www.protan.com
The information in this document is believed to be correct at the date of publication. Protan AS does not accept any liability for errors or omissions, or for any consequences resulting therefrom.