7.2 PEM6 7.4 7.3 PEM7 7.4 PIB1 7.5 PIB2 PIB5 PEM2 PEM8 7.5 7.6 7.3 7.5 PIB3 PIB4 7.6 PIB6 PIB7 7.7 7.7 1.9 1.9 1.10 1.10 1.11 1.11 1.12 1.10 Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 Pg7 7.2 Emergency LEGAL REQUIREMENTS The Occupational Health and Safety Act (Act 85 of 1993) requires emergency evacuation lighting for workplaces without natural light. It is therefore illegal not to have emergency evacuation lighting in work areas or public places where no natural light is present. A minimum of 0.3 lux at the floor level is required to enable evacuation but a level of not less than 20 lux is required for moving machinery or where it is necessary to shut down plant or processes where dangerous materials are present. The act also requires that the emergency lighting must be activated within 15 seconds and the emergency lighting must be kept in good working order and tested at intervals of not more than three months.All emergency lighting must comply with the following requirements of SABS 1464 Part 22: Classification: Emergency luminaires shall have labelling to indicate whether they are self contained or centrally supplied, maintained or non-maintained, have test devices and emergency duration. The following symbols shall be used: X = self-contained, Z = centralsupply, 0 = non-maintained, 1 = maintained, 6 = satellite, A = including test devices, B =including remote rest mode, C = including inhibiting mode, D = high risk task area lighting, 10 = ten minutes duration, 60 = one hour duration, 120 = two hours duration, 180 = three hours duration. Marking: Luminaires shall be clearly marked with rated voltage, correct replacement lamps and maximum ambient temperature. Emergency lamp holders in combined luminaires shall be identified by a green dot. A label on the battery pack shall indicate replacement battery details, battery manufacture and commissioning date. An instruction leaflet shall be provided detailing test facilities and test procedures. Electrical safety: Requirements of SABS 598-1 shall apply. Endurance and thermal testing: The unit must satisfy various soak and cycle testing to ensure reliability. Battery charge and discharge: The batteries must be charged within 24 hours, deep battery discharge must be prevented and high temperature batteries must be used in self contained emergency luminaires. Pg7.1 Photometric performance: The luminaire shall provide rated lumen output claimed by the manufacturer during emergency mode for 1 minute after failure of supply and continuously to the end of rated duration. In other words, if the unit is marked as a 50% light output then the emergency light output must be 50% of the mains light output. Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 PEM6 LED Emergency exit Code PEM6-LED L 375 W 147 H Lamp H Lamp 25 LED FEATURES: • 2 hour emergency duration • Slimline • Satisfies all SABS specifications • Long life LED’s • All SABS legends available • Energy saving PEM7 LED Emergency exit Code PEM7-LED L 375 W 147 25 LED Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 Pg7.2 FEATURES: • 5 hour emergency duration • Slimline • Satisfies all SABS specifications • Long life LED’s • Energy saving PEM8 Emergency exit Code L PEM8-19SS 550 PEM8-29SS 550 PEM8-19DS 550 PEM8-29DS 550 OPTIONS: /ECG - Electronic control gear W 355 355 355 355 H Lamp H Lamp 130 130 130 130 1 x 9w CFL 2 x 9w CFL 1 x 9w CFL 2 x 9w CFL FEATURES: • An economical range of beveled edge exit signs. • Available with single or double side. • Available with different pictograms. • Standard with conventional control gear PEM2 Pg7.3 FEATURES: • Standard with EXIT pictoral • Ceiling or wall mounted • Toughened glass lense • SMC-fiberglass frame Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Emergency exit Code L W PEM2EXIT-29PL 310 310 PEM2MAN-29PL 310 310 OPTIONS: /ECG - Electronic control gear /EMG - Emergency gear /RD - Running man down exit /RL - Running man left exit /RR - Running man right exit /DS - Double sided /M - Maintained mode /NM - Non-maintained mode Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] 65 65 2x 9w 2x 9w Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 PIB1 Emergency pack Code Duration Lamp Type PIB1- 1HR 1 Hour Fluorescent up to 65w PIB1- 3HR 3 Hour Fluorescent up to 65w • Figures below for 1hr units (3hr units figures in brackets) Lamp Type OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch PIB2 Self testing pack Code PIB2- 1HR PIB2- 3HR Lamp Type OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch Light Output Battery Current Duration T8 : 58w 12% (11%) 1.3A (1A) 1.4 (4) hours T8 : 36w 18% (15%) 1.1A (0.9A) 1.6 (4.4) hours T8 : 18w 20% (22%) 0.7A (0.7A) 2.6 (6.1) hours T8 : 10w 30% (32%) 0.6A (0.5A) 3 (8) hours T5 : 8w 40% (45%) 0.7A (0.6A) 2.6 (6.8) hours TC-DEL: 26w 32% (18%) 1.2A (0.8A) 1.5 (4.7) hours TC-DEL: 18w 29% (26%) 1A (0.8A) 1.8 (4.7) hours TC-DEL: 13w 36% (30%) 1A (0.6A) 1.8 (6.8) hours TC-DD : 28w 25% (15%) 1.2A (0.7A) 1.5 (6.1) hours TC-L : 18w 23% (19%) 0.7A (0.6A) 2.6 (6.8) hours TC-EL : 11w 43% (42%) 0.9A (0.6A) 2 (6.8) hours TC-EL : 9w 36% (31%) 0.6A (0.5A) 3 (8) hours TC-EL : 7w 38% (44%) 0.7A (0.5A) 2.6 (8) hours Note: The emergency lighting duration and light output may vary due to ambient temperature, cell type and lamp manufacturer. The PIB1emergency control units cover all axial fluorescent lamps as well as four pin compact types from 6 to 65 Watts. T8 : 58w T8 : 36w T8 : 18w T5 : 8w TC-DEL: 26w TC-DEL: 18w TC-DEL: 13w TC-DD : 16w TC-DD : 26w TC-L : 18w TC-EL : 9w Duration Lamp Type 1 Hour 3 Hour Fluorescent up to 65w Fluorescent up to 65w Light Output Battery Current 15% 20% 44% 71% 27% 30% 38% 38% 25% 38% 58% 1.2 A 1.1 A 1.1 A 0.9 A 1A 1A 0.8 1A 1A 1A 0.9 Duration 1.7 (3.3) 1.8 (3.6) 1.8 (3.6) 2.2 (4.4) 2 (4) 2 (4) 2.5 (5) 2 (4) 2 (4) 2 (4) 2.2 (4.4) Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 Pg7.4 This emergency lighting control unit incorporates a self testing facility that exercises batteries and establishes lamp condition on a regular basis. Automatic tests are conducted on a weekly basis with full functional tests every month. The weekly tests, of two minutes duration, establish battery and lamp condition whilst the monthly tests last 40 minutes in order to remove battery memory effects. System faults are reported via both audible and visual means PIB3 Emergency pack Code PIB3-1HR Duration 1 Hour Lamp Type 36w & 58w The PIB3 emergency control units achieve 50% light output for 1 hour on 36w and 58w linear fluorescent tubes OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch PIB4 Emergency pack Code PIB4-1HR Duration 1 Hour Lamp Type 36w & 58w The PIB4 emergency control units achieve 100% light output for 1 hour on 36w and 58w linear fluorescent tubes OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch PIB5 Emergency pack Code PIB5-1HR Duration 1 Hour Lamp Type 2 Pin Compact fluorescent Pg7.5 The PIB5 emergency control units are for 1 hour duration on compact fluorescent lamps. The inverter’s small dimensions make it possible to mount in smaller luminaires OPTIONS: LIGHT OUTPUT: /M - Maintained 26w - 40% 11w - 70% /NM - Non-Maintained 18w - 50% 9w - 80% /STS - Stand by switch 13w - 60% 7w - 100% Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 PIB6 Emergency pack Code PIB6-1HR Duration 1 Hour Lamp Type LV & 8w Fluorescent The PIB6 System can be connected to six 8W fluorescent lamps, or two 12V 20W halogen lamps or one 12V 50W lamp OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch Photometric data available on request PIB7 Emergency pack Code PIB7-1HR Duration 1 Hour Lamp Type 20w & 50w LV The PIB7 has beeen designed to fit through the downlight hole in to the ceiling cavity, the unit can be used in maintained mode (where the normal Lv supply, fixed or dimming, is routed through the unit). Johannesburg Unit 3 Incredible Solutions 8 Olympia Street Eastgate Ext 11 Sandton Tel: +27 11 262 5179 Head Office Cape Town 100 Upper Canterbury Str Tel: +27 21 464-4661 Fax: +27 21 464-4664 Email: [email protected] Namibia-Windhoek Unit 2, Tesoro Building 31 TV More Street Windhoek Tel: +264 61 40 0339 Pg7.6 OPTIONS: /M - Maintained /NM - Non-Maintained /STS - Stand by switch
© Copyright 2026 Paperzz