Emergency Catalogue

7.2
PEM6
7.4
7.3
PEM7
7.4
PIB1
7.5
PIB2
PIB5
PEM2
PEM8
7.5
7.6
7.3
7.5
PIB3
PIB4
7.6
PIB6
PIB7
7.7
7.7
1.9
1.9
1.10
1.10
1.11
1.11
1.12
1.10
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
Pg7
7.2
Emergency
LEGAL REQUIREMENTS
The Occupational Health and Safety Act (Act 85 of 1993) requires emergency evacuation lighting for
workplaces without natural light. It is therefore illegal not to have emergency evacuation lighting in work
areas or public places where no natural light is present. A minimum of 0.3 lux at the floor level is required
to enable evacuation but a level of not less than 20 lux is required for moving machinery or where it is
necessary to shut down plant or processes where dangerous materials are present. The act also requires
that the emergency lighting must be activated within 15 seconds and the emergency lighting must be kept
in good working order and tested at intervals of not more than three months.All emergency lighting must
comply with the following requirements of SABS 1464 Part 22:
Classification: Emergency luminaires shall have labelling to indicate whether they are self contained or
centrally supplied, maintained or non-maintained, have test devices and emergency duration. The following
symbols shall be used: X = self-contained, Z = centralsupply, 0 = non-maintained, 1 = maintained,
6 = satellite, A = including test devices, B =including remote rest mode, C = including inhibiting mode,
D = high risk task area lighting, 10 = ten minutes duration, 60 = one hour duration, 120 = two hours
duration, 180 = three hours duration.
Marking: Luminaires shall be clearly marked with rated voltage, correct replacement lamps and maximum
ambient temperature. Emergency lamp holders in combined luminaires shall be identified by a green dot.
A label on the battery pack shall indicate replacement battery details, battery manufacture and
commissioning date.
An instruction leaflet shall be provided detailing test facilities and test procedures.
Electrical safety: Requirements of SABS 598-1 shall apply.
Endurance and thermal testing: The unit must satisfy various soak and cycle testing to ensure reliability.
Battery charge and discharge: The batteries must be charged within 24 hours, deep battery discharge
must be prevented and high temperature batteries must be used in self contained emergency luminaires.
Pg7.1
Photometric performance: The luminaire shall provide rated lumen output claimed by the manufacturer
during emergency mode for 1 minute after failure of supply and continuously to the end of rated duration.
In other words, if the unit is marked as a 50% light output then the emergency light output must be 50%
of the mains light output.
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
PEM6
LED Emergency exit
Code
PEM6-LED
L
375
W
147
H
Lamp
H
Lamp
25
LED
FEATURES:
• 2 hour emergency duration
• Slimline
• Satisfies all SABS specifications
• Long life LED’s
• All SABS legends available
• Energy saving
PEM7
LED Emergency exit
Code
PEM7-LED
L
375
W
147
25
LED
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
Pg7.2
FEATURES:
• 5 hour emergency duration
• Slimline
• Satisfies all SABS specifications
• Long life LED’s
• Energy saving
PEM8
Emergency exit
Code
L
PEM8-19SS
550
PEM8-29SS
550
PEM8-19DS
550
PEM8-29DS
550
OPTIONS:
/ECG - Electronic control gear
W
355
355
355
355
H
Lamp
H
Lamp
130
130
130
130
1 x 9w CFL
2 x 9w CFL
1 x 9w CFL
2 x 9w CFL
FEATURES:
• An economical range of beveled
edge exit signs.
• Available with single or double side.
• Available with different pictograms.
• Standard with conventional control
gear
PEM2
Pg7.3
FEATURES:
• Standard with EXIT pictoral
• Ceiling or wall mounted
• Toughened glass lense
• SMC-fiberglass frame
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Emergency exit
Code
L
W
PEM2EXIT-29PL 310
310
PEM2MAN-29PL 310
310
OPTIONS:
/ECG - Electronic control gear
/EMG - Emergency gear
/RD
- Running man down exit
/RL
- Running man left exit
/RR
- Running man right exit
/DS
- Double sided
/M
- Maintained mode
/NM - Non-maintained mode
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
65
65
2x 9w
2x 9w
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
PIB1
Emergency pack
Code
Duration
Lamp Type
PIB1- 1HR
1 Hour
Fluorescent up to 65w
PIB1- 3HR
3 Hour
Fluorescent up to 65w
• Figures below for 1hr units (3hr units figures in brackets)
Lamp Type
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch
PIB2
Self testing pack
Code
PIB2- 1HR
PIB2- 3HR
Lamp Type
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch
Light Output Battery Current Duration
T8 : 58w
12% (11%)
1.3A (1A)
1.4 (4) hours
T8 : 36w
18% (15%)
1.1A (0.9A)
1.6 (4.4) hours
T8 : 18w
20% (22%)
0.7A (0.7A)
2.6 (6.1) hours
T8 : 10w
30% (32%)
0.6A (0.5A)
3 (8) hours
T5 : 8w
40% (45%)
0.7A (0.6A)
2.6 (6.8) hours
TC-DEL: 26w
32% (18%)
1.2A (0.8A)
1.5 (4.7) hours
TC-DEL: 18w
29% (26%)
1A (0.8A)
1.8 (4.7) hours
TC-DEL: 13w
36% (30%)
1A (0.6A)
1.8 (6.8) hours
TC-DD : 28w
25% (15%)
1.2A (0.7A)
1.5 (6.1) hours
TC-L : 18w
23% (19%)
0.7A (0.6A)
2.6 (6.8) hours
TC-EL : 11w
43% (42%)
0.9A (0.6A)
2 (6.8) hours
TC-EL : 9w
36% (31%)
0.6A (0.5A)
3 (8) hours
TC-EL : 7w
38% (44%)
0.7A (0.5A)
2.6 (8) hours
Note: The emergency lighting duration and light output may vary due to
ambient temperature, cell type and lamp manufacturer.
The PIB1emergency control units cover all axial fluorescent lamps
as well as four pin compact types from 6 to 65 Watts.
T8 : 58w
T8 : 36w
T8 : 18w
T5 : 8w
TC-DEL: 26w
TC-DEL: 18w
TC-DEL: 13w
TC-DD : 16w
TC-DD : 26w
TC-L : 18w
TC-EL : 9w
Duration
Lamp Type
1 Hour
3 Hour
Fluorescent up to 65w
Fluorescent up to 65w
Light Output Battery Current
15%
20%
44%
71%
27%
30%
38%
38%
25%
38%
58%
1.2 A
1.1 A
1.1 A
0.9 A
1A
1A
0.8
1A
1A
1A
0.9
Duration
1.7 (3.3)
1.8 (3.6)
1.8 (3.6)
2.2 (4.4)
2 (4)
2 (4)
2.5 (5)
2 (4)
2 (4)
2 (4)
2.2 (4.4)
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
Pg7.4
This emergency lighting control unit incorporates a self testing facility that
exercises batteries and establishes lamp condition on a regular basis.
Automatic tests are conducted on a weekly basis with full functional tests
every month. The weekly tests, of two minutes duration, establish battery
and lamp condition whilst the monthly tests last 40 minutes in order to
remove battery memory effects. System faults are reported via both audible
and visual means
PIB3
Emergency pack
Code
PIB3-1HR
Duration
1 Hour
Lamp Type
36w & 58w
The PIB3 emergency control units achieve 50% light output for 1
hour on 36w and 58w linear fluorescent tubes
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch
PIB4
Emergency pack
Code
PIB4-1HR
Duration
1 Hour
Lamp Type
36w & 58w
The PIB4 emergency control units achieve 100% light output
for 1 hour on 36w and 58w linear fluorescent tubes
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch
PIB5
Emergency pack
Code
PIB5-1HR
Duration
1 Hour
Lamp Type
2 Pin Compact fluorescent
Pg7.5
The PIB5 emergency control units are for 1 hour duration on
compact fluorescent lamps. The inverter’s small dimensions
make it possible to mount in smaller luminaires
OPTIONS:
LIGHT OUTPUT:
/M
- Maintained
26w - 40%
11w - 70%
/NM - Non-Maintained
18w - 50%
9w - 80%
/STS - Stand by switch
13w - 60%
7w - 100%
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
PIB6
Emergency pack
Code
PIB6-1HR
Duration
1 Hour
Lamp Type
LV & 8w Fluorescent
The PIB6 System can be connected to six 8W fluorescent lamps,
or two 12V 20W halogen lamps or one 12V 50W lamp
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch
Photometric data available on request
PIB7
Emergency pack
Code
PIB7-1HR
Duration
1 Hour
Lamp Type
20w & 50w LV
The PIB7 has beeen designed to fit through the
downlight hole in to the ceiling cavity, the unit can
be used in maintained mode (where the normal Lv
supply, fixed or dimming, is routed through the unit).
Johannesburg
Unit 3 Incredible Solutions
8 Olympia Street
Eastgate Ext 11 Sandton
Tel: +27 11 262 5179
Head Office
Cape Town
100 Upper Canterbury Str
Tel: +27 21 464-4661
Fax: +27 21 464-4664
Email: [email protected]
Namibia-Windhoek
Unit 2, Tesoro Building
31 TV More Street
Windhoek
Tel: +264 61 40 0339
Pg7.6
OPTIONS:
/M
- Maintained
/NM - Non-Maintained
/STS - Stand by switch