Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE — Provides minimum of 90 minutes of illumination for rated wattage upon loss of AC power. Unique design for light and heavy industrial applications, as well as heavy commercial environments. Superior performance lamp heads are ideal for higher mounting heights. CONSTRUCTION — Rugged front and navy back (std. colors) .140” thick, injection-molded thermoplastic (large back housing is .187” thick, compression-molded composite). Vertical orientation, designed for pole or column mounting. Also suitable for wall, I-beam and unistrut mounting. Easy installation with epoxy-coated, corrosion-resistant, 12-gauge steel mounting bracket shipped standard. U.S. Patent No. 6,135,624 - Mounting Bracket Utility patent. Conduit entry points located on top and both sides of unit. Maintenance made easy by tool-less lamp replacement, hinged front cover, printed circuit board mounting shelf and battery belt. U.S. Patent No. D419,097 - Design patent. OPTICS — Lamps: U.S. Patent No. 6,193,395 - Lamp Head Utility patent. Full range of lamp options available from 9W to 50W in sealed-beam or composite versions of krypton or halogen lamps. Composite lamps feature unique field-adjustable beam spread (by turning lamp bezel). ELECTRICAL — Dual voltage input capacity (120/277V). Brownout protection is standard feature of self-diagnostics. AC/LVD reset prevents battery damage from deep discharge. Current limiting charger. Thermal protection prevents overheating and charger failure. Thermal compensation provides optimum charge voltage relative to ambient temperature. Battery: Sealed, maintenance-free, lead-acid (SLA) battery with capacity of 18W to 450W for 90 minutes of emergency operation. Available in 6V and 12V. Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. P2 and P3 options offer high-temperature batteries (DM802618 and DM80212100 only). UL listed from 32°F to 131°F (0° C to 55° C) (P2) or -40°F to 131°F (-40° C to 55° C ) (P3). Diagnostics (with P1, P2 and P3 packages): US Patent No. 6,502,044 - Self Diagnostics utility patent. Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Load learning capability self-calibrates to DC load at first test, enabling it to detect a lamp failure on future tests. May be re-calibrated at any time by holding down test switch for 15 seconds. INSTALLATION — Column and pole mounting standard (12-gauge steel mounting bracket included). Other mounting options available for ceiling mount or I-Beam mounting (see accessories). LISTINGS — UL Listed. Damp location listing. Meets UL 924, NFPA 101 (current Life Safety Code), NFPA 101-NEC and OSHA illumination standards. ORDERING INFORMATION Series 6 Volts DM802618 DM802654 12 Volts DM8021254 DM80212100 DM80212150 DM80212450 Industrial Emergency Lighting Unit DeSoto M802 6 or 12 Volts Sealed Lead-Acid (SLA) or Ni-Cad Battery Small Housing Large Housing WARRANTY — Three-year limited warranty. (Battery is prorated.) Five-year pro-rated warranty on ni-cad batteries.Complete warranty terms located at: http://www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice. For shortest lead times, configure product using bolded options. Housing color (blank) Gray front/navy back 18W 54W 54W 100W1 150W1 450W1 Lamp type (2 heads) 6 Volts PAR36 Composite K0906 9W/6V krypton8 H2006 20W/6V halogen8 12 Volts PAR36 Composite H2012 20W/12V halogen9 PAR36 Sealed-Beam H3512S 35W/12V halogen H5012S 50W/12V halogen Example: DM802618 K0906 P1 Options (blank) Features remote test, time delay and damp location 50° F to 104° F (10° C to 40° C)3 P1 Features self-diagnostics, time delay, remote test and damp location 50° F to 104° F (10° C to 40° C)3 P2 Features high-temperature ni-cad battery (DM802618 only) or high-temperature lead calcium battery (DM80212100 only), self-diagnostics, time delay, remote test and damp location. UL listed for 32° F to 131° F(0° C to 55° C) 3, 4, 6 P3 Features heater, thermostat and battery blanket with a high temperature ni-cad battery (DM802618 only) or high-temperature lead-calcium battery (DM80212100 only), self-diagnostics, time delay, remote test and damp location. UL listed for -40° F to 131° F (-40° C to 55o C)3, 4, 6 NOTES: Accessories: Order as separate catalog number ELA DM RTT ELA WG2M ELA WGLG ELA BS ELA DM802 PM EMERGENCY Remote test transmitter 3 Wire guard - small (18W-100W)7 Wireguard - large (150-450W)7 Banding Strap (see spec sheet ELA-DM-RTT-BS) Pendant mount kit for DM802618/654/1254/121005,7 ELA DM802 CM1 ELA DM802 CM2 ELA DM802 K0906 Ceiling mount kit for DM8026182,7 Ceiling mount kit for DM802654/1236/12542,7 Single remote head, PAR36 composite 6V9W krypton lamp10 ELA DM802 T K0906 Twin remote head, PAR36 composite 6V9W krypton lamps10 1. Not suitable for ceiling mount. 2. Required for ceiling mount. Color is not a factor. 3. Must order a Remote transmitter (ELA DM RTT). One per job required. See spec sheet ELA-DM-RTT-BS. 4. Only available on DM802618 and DM80212100. 5. ELA DM802 PM accessory cannot be used with the DM80212100 P2 or DM80212100 P3. Color is not a factor. 6. DM80212100 P2 and DM80212100 P3 come in a larger housing size. 7. See spec sheet ELA-DM-PM-CM-WG. 8. K0906 only available for DM802618; H2006 only available for DM802654. 9. H2012 standard lamp for DM8021254/12100/12150/12450 10. See spec sheet ELA-DM802-DM90X for additional remote heads available. DESOTO M802 DeSoto M802 Industrial Emergency Lighting Units, 6/12 Volts MOUNTING SPECIFICATIONS All dimensions are inches (centimeters). Shipping weight: DM802618 - 13 lbs. (5.9 kgs ) DM80212150 - 45 lbs. ( 20.4 kgs) DM802654 - 18 lbs. (8.2 kgs) DM80212450 - 75 lbs. (30.0 kgs) DM8021254 - 18 lbs. (8.2 kgs) DM80212100 - 27 lbs. (12.2 kgs) ELECTRICAL: Primary Circuit Type DM802618 DM802654 DM8021254 DM80212100 DM80212150 DM80212450 Volts AC Input Amps1 Watts1 120 .163 19.6 277 .069 19.11 120 .172 20.64 277 .075 20.78 120 .174 20.88 277 .078 21.6 120 .174 20.88 277 .074 20.49 120 .359 43.08 277 .168 46.54 120 .33 39.96 277 .15 43.77 Output Volts 1-1/2 hrs. 2 hrs. 3 hrs. 4 hrs. 6 18 13.5 9 6 Large Housing (100W P2 and P3; 150-450W) 6 54 40 27 20 12 54 40 27 20 12 100 75 50 37 12 150 112 75 56 12 450 337 225 168 18 (45.7) 16 (40.6) 13-1/4 (33.7) 16 (40.6) Small Housing (18-54W; 100W Standard and P1) 12 (31.0) Mounting bracket 8-5/8 (22.0) 9 (22.9) BATTERY High-Temperature Nickel-Cadmium Shelf life2 Typical life3 Maintenance4 Optimum Temperature5 6/12 3 yrs. 7-9 yrs. none 32 -131 F (0 -55 C) 0 0 0 2-1/4 (5.7) 8 (20.3) 3/4 (1.9) 0 Voltage Shelf life Typical life Maintenance Optimum Temperature 6/12 1 yr. 3-5 yrs. none 600-900F (160-320C) 4 1 (2.5) 1/4 (6.0) 2-1/4 (57.0) 2-3/4 (7.0) PHOTOMETRICS For additional spacing information, see the complete list of DeSoto M802 ies files. Lead-Acid (SLA) 3 8-3/8 (21.3) 12-1/2 (31.8) Voltage 2 3/8 (10.0) 5 ELA DM802 K0906 One (1) 9 Watt Krypton In Vertical, Base Up Position HORIZONTAL High-Temperature Lead-Acid (SLA) 6 Voltage Shelf life2 Typical life3 Maintenance4 Optimum Temperature5 6/12 1 yr. 5-7 yrs. none 320-1310F (00-550C) 4 2 0 1 0.5 0.3 1 0.5 0.3 20 30 2 NOTES: 1 For ULT option consult factory for input power factor, if required. 2 At 77°F (25°C). 3 Based on normal room temperatures and conditions. 4 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. 5 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. 4 6 VERTICAL 6 4 2 0 2 4 6 10 40 Ft. PERFORMANCE DIAGRAMS KEY FEATURES FLOOD 25.5' Center-to-center spacing* yields 25.5'. MEDIUM DM802 K0906 Medium Distribution SPOT 12-gauge epoxy-coated steel mounting bracket included with each unit. Field-adjusted beam pattern for composite lamps. 3' ELA DM RTT Order remote transmitter separately. *Note: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes space of 200'L x 200'W x 30'H, mounting height: 12', ceiling height: 30', and reflectances: 10/10/10. Analysis based on independently tested photometrics. EMERGENCY: DESOTO M802 3825 Columbus Road, Granville, OH 43023 Phone: 740-345-9631 www.holophane.com © 2013-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 03/02/2016
© Copyright 2024 Paperzz