DISPLACEMENT 64 AWB Bow shaped displacement unit • • • • Special dimensions Compact design High finish Suitable for all types of rooms AWB is a bow shaped displacement unit for wall mounting, which provides supply air at low velocity. The terminals are suitable for comfort installations. AWB is installed with base, decorative top or duct cover as accessory. Width, depth and connections are standardized while the height is made according to costumer’s requirement. Design The unit consists of a back plate with top, bottom and air distribution plate with nozzles. It is available with top/bottom connection or rear connection if a duct cover is used. The connection in the top or rear is round. In a version for bottom connection AWB is made with rectangular connection. The back plate with its components is fixed to corner profiles. The perforated front is mounted to the corner profiles with a few screws. If AWB is order without duct cover it is delivered with a top lid in painted sheet steel. As accessory it can be supplied with a decorative top in painted MDF or in various wood material Material Front plate made in 1.25 mm hot dipped galvanized sheet steel. Other parts in galvanized sheet steel with thickness depending on size. Visible parts powder coated in RAL 9010. Other colors according to RAL or NCS are available on request. Round top connection and duct cover Round rear connection in the duct cover. Specials versions Other dimensions Stainless steel Standard EN 1.4301 Surface brushed Other qualities on request Base std height 100 Bas Reinforced front Accessory Duct cover Base Decorative top Damper . Waterloo 6.0 Round bottom connection and base. Rectangular bottom connection and supply duct with round connection. Unit with bottom connection, base and decorative top. Tel: +44 (0) 1622 717861 DISPLACEMENT 65 AWB Dimensions and weights A,C,Ø is standard dimensions. B is chosen according to costumers requirement Bs = suitable height B which fits to A,C,Ø Max B is 2000 40 Ønom 100-250 Ø AWB-R LMax 1960 20 AWB-T/B 100 125 160 A 400 500 640 Bs 600 600 600 C 150 180 210 D 70 83 100 Ø 100 125 160 kg 25 30 38 200 800 1000 250 120 200 47 2000 Table 1 Table 2 B AWB-R 125 A 400 Bs 600 C 150 Ø 125 kg 25 160 200 500 640 600 600 180 210 160 200 30 38 250 800 1000 250 250 47 A D C Ø AWB-T/B Table 3 AWB/O-T/B 100 A 400 Bs 600 C 150 D 70 Ø 100 kg 8 125 160 500 640 600 600 180 210 83 100 125 160 9 10 200 800 1000 250 120 200 24 B A D C Ø AWB/O Table 4 A 400 Bs 600 C 150 e 60 f 280 kg 90 002-600 003-600 500 640 600 600 180 210 60 90 350 400 10 11 004-1000 800 1000 250 100 600 25 100-250 AWB/O-TB 001-600 f 100 B Accessory Base: Standard height of base is 100 , other heights on request. A e C Supply duct: Length is made according to request : Table 5 AWB/O g h Ø L 001 284 64 160 280-2000 002 003 354 404 64 94 160 200 280-2000 320-2000 004 604 104 250 370-2000 Waterloo 6.0 20 Ø L h g Tel: +44 (0) 1622 717861 DISPLACEMENT 66 AWB Quick selection table AWB standard sizes dB(A) value as sound power level LwA Adjacent zones L02 for under temperute 3K and 6K AWB Round connection top or bottom as table 1 and table 3 The velocity over the front is 0.15m/s Size 100-600 125-600 160-600 200-1000 l/s 35 50 63 130 dB(A) 38 36 31 37 L02 m 0.5/0.8 0.6/1 0.7/1.1 0.9/1.4 AWB-R rear connection as table 2 The velocity over the front is 0.2m/s Size 125-600 l/s 50 dB(A) 36 L02 m 0.7/1.1 160-600 200-200 250-1000 68 85 170 34 32 36 0.9/1.3 0.9/1.4 1.2/1.8 AWB Rectangular connection top or bottom as table 4 The velocity over the front is 0.2m/s Size 001-600 002-600 003-600 004-1000 Waterloo 6.0 l/s 50 68 85 170 dB(A) 33 35 31 31 L02 m 0.7/1.1 0.9/1.3 1/1.5 1/1.6 Tel: +44 (0) 1622 717861 DISPLACEMENT 67 AWB Assembly The AWB terminal is mounted to the wall by removing the front plate and screw through the back plate . If a base is used it is first fitted to the bottom of the terminal. The duct cover is mounted to the wall using corner profiles. The length of the duct cover is made according to costumer’s specification. Max length in one piece is 1960. By using several duct covers overlapping each other lengths exceeding max values are achieved. Top connection Rear connection Maintenance There are no parts in the units that have to be replaced. If necessary clean the front with water and mild detergent. Specification AWB bow shaped displacement unit to be mounted on walls. Terminal including internal air distribution plate with nozzles. Width… mm Depth…mm Height…mm top/bottom/rear connection ......... mm. Removable front and corner profiles made in galvanized sheet steel powder coated in RAL 9010. Waterloo 6.0 Alt. Top lid made in powder painted sheet steel/ Duct cover with corner profiles in galvanized sheet steel powder coated in RAL 9010. Duct covers length above terminal …..mm. Accessory: Base with height 100mm in galvanized sheet steel powder coated in RAL 9010. Alt. Powder coat in special color according to RAL or NCS. Supply duc in galvanized sheet steel t total length ......mm with round connection Ø ... mm. Tel: +44 (0) 1622 717861 DISPLACEMENT 68 AWB Product code AWB aaa-bbbb-c-ddd RAL9010 Total length of unit mm R= Including duct cover , rear connection T= Including duct cover , top connection B= Including duct cover . bottom connection Active Height (B) mm Size according to table 1-2 AWB/O aaa-bbbb-c RAL9010 T= top connection B= bottom connection Active Height (B) mm Size according to table 3-4 Without duct cover Base AWB-aaa-b /100 RAL9010 Height in mm R= rear connection T/B = top or bottom connection Size according to table 1-4 Waterloo 6.0 Tel: +44 (0) 1622 717861
© Copyright 2026 Paperzz