Laars® Oil-Fired Water Heaters Photo is of L-CF-32-6 Features: ■ Factory Installed Sediment Reduction System—(Center flue models only) cold water inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up at top of tank. ■ Glass Lined Tank—LAARS Heating Systems water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. ■ Flexible Stainless Steel Baffle—(Center flue models only) hinged for low ceiling removal and cleaning. Designed for optimal heat transfer. ■ Controls—Dual immersion aquastat (supplied with burner) for precise, easy water temperature regulation and safety. ■ Fiberglass Insulation—High density fiberglass insulation provides a thick blanket around tank and combustion chamber for more heat retention and maximum fuel efficiency. ■ Ceramic Fiber Combustion Chamber—Concentrates the flame for a smaller, hotter fire and faster transfer of maximum heat. ■ Two Protective Magnesium Anode Rods—(Rear flue models have one anode rod) provides added protection against corrosion for long trouble-free service. ■ Brass Drain Valve. ■ Lowest Operating Cost—LAARS Heating Systems oil-fired water heaters provide hot water more economically than heaters powered with other fuels. Costs can be cut as much as 60 percent with these new units. ■ High Recovery Rates—Oil heats water 3 to 4 times faster than other methods. These models are designed to assure a constant supply of hot water provided the draw-off rate is within the recovery capacity of the unit. Center flue models from 32 to 50 gallons capacity delivery recovery rates as high as 114 gallons per hour. Rear flue models are designed for heavier demand with recovery rates as high as 184 gallons per hour. ■ Installed T&P Relief Valve. ■ Installation—Occupies relatively little floor space and does not require a separate fuel oil storage tank when used in an oil-heated residence. ■ Oil Burners—Beckett burners are available. Carlin and Riello are optional burners, but not available through LAARS Heating Systems. ■ Steel Tank—Heavy guage steel automatically formed, rolled and welded to assure a continuous seam for glass lining. 6-Year Limited Tank Warranties / 2-Year Limited Warranty on Parts and Burner. For products installed in USA, Canada and Puerto Rico. Some states and provinces do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105. Laars® Oil-Fired Water Heaters Energy Saver Models Meet or exceed ASHRAE 90.1b (current standard). Recovery at 100°F* Rise Capacity Model Number L-CF-32-6 L-CF-50-6 L-RF-30-6 L-RF-30SX-6 L-RF-50-6 U.S. Gal. 32 50 30 30 50 Imp. Gal. MBTUH* Input 27 42 25 25 42 91/105 105/119 119 119 175/189 Firing Rate .65/.75 .75/.85 .85 .85 1.25/1.35 U.S. GPH 88/102 97/114 116 118 170/184 L-CF-32-6 L-CF-50-6 L-RF-30-6 L-RF-30SX-6 L-RF-50-6 121 189 114 114 189 Approx. Water Air Tube Shipping Conn. Length Weight in. in. in. in. in. in. in. lbs. 74/85 81/95 97 99 142/154 51 1⁄2 62 55 1⁄2 49 1⁄2 68 1⁄2 20 1⁄2 23 1⁄2 23 1⁄2 24 3⁄4 26 1⁄2 6 6 6 6 7 – – 49 43 61 53 3⁄4 64 1⁄4 – – – ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 11⁄4 5 1⁄2 7 7 7 7 1⁄2 215 275 250 210 360 Nat. Liters/ Hour 333/386 367/431 439 446 kW Input 26.7/30.1 30.1/35.0 35.0 35.0 51.2/55.4 Liters E D C B Jacket Flue Floor to Floor to Dia. Conn. Flue Center Flue Imp. GPH Recovery at 50°C* Rise Capacity Model Number A Floor to Flue Conn. 643/696 A Floor to Flue Conn. D C B Jacket Flue Floor to Dia. Conn. Flue Center 3 E Floor to Flue Approx. Water Air Tube Shipping Conn. Length Weight AERO Burner Part Number Becket Burner Part Number AB1 AB2 AB3 AB3 AB4 BB1 BB2 BB3 BB3 BB4 AERO Burner Part Number Becket Burner Part Number mm. mm. mm. mm. mm. mm. mm. 1308 1575 1410 1257 521 597 597 629 152 152 152 152 – – 1245 1092 1365 1632 – – 19 19 19 19 133 178 178 178 98 125 113 95 AB1 AB2 AB3 AB3 BB1 BB2 BB3 BB3 1740 673 178 1549 – 32 191 163 AB4 BB4 CF = Center Flue RF = Rear Flue *MBTUH = Thousand Btu's/Hr. kg. BECKET Burner Part Number B C B E A BB1-228-44392-01 BB2-228-44392-03 BB3-228-44392-07 BB3-228-44392-07 BB4-228-44392-09 A D CENTER FLUE REAR FLUE General All Oil-Powered water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). Fuel: Approved for use with No. 2 fuel oil or lighter. Power Supply: 60 cycle, 115 volt, single phase (consult factory for other voltages.) Shipping weight for water heater less Oil Burner - deduct 40 lbs/18 kg. All center flue water heaters meet or exceed DOE and CSA B211 energy requirements as certified by ETL. All water heaters must be installed with a temperature and pressure relief valve and on a non-combustible floor. All water heaters are approved for use with “L” vent. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. 800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors) 20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130 www.Laars.com Litho in U.S.A. © Laars Heating Systems 0806 Document 11023
© Copyright 2026 Paperzz