Flat roof area to be provided 13mm with white chippings on 3 layers hot bonded Ruberoid roofing felt on 126mm Celotex TD400 Insulation on firrings laid min 1:60 fall on 175 x 50 @ 400cc C16 flat roof joists. Provide lead flashing to suitably seal between flat roof and pitched roof. Provide velux windows fitted in accordance with manufacturers requirements. Allow for double rafters each side. Velux GGL 78x118 Strip off extg jack rafters and provide new 100x50 rafters to match. Provide FR 4000 50mm Celotex insulation within rafters so that 50mm of ventilation is maintained over. Provide FR4000 90mm to underside of rafters, provide 12.5 mm plaster board over with skim finish. Flank window to be provided with obscure glass and top light opener only 3.45m 3.90m Tiles to match existing on tile battens on tyvek pro V underlay on 19mm plywood or OSB boarding on 125x50 @ 400cc vertical studs filled with 120mm GA400 Celotex insulation Provide 12.5mm plasterboard and set internally. Provide 9mm masterboard where within 1m of boundary 3.05m 3.05m 2.70m 7.61m Provide code 4 lead flashing where dormer meets extg Alter and extend existing stack to vent min 900mm above windows. Front Elevation Flank Elevation Flat roof area to be provided 13mm with white chippings on 3 layers hot bonded Ruberoid roofing felt on 126mm Celotex TD400 Insulation on firrings laid min 1:60 fall on 175 x 50 @ 400cc C16 flat roof joists. Provide lead flashing to suitably seal between flat roof and pitched roof. Proposed windows to be double glazed with argon fill and low emmisivity coating. Max U value to be 1.6W/m2k. Suggest Pilkington K glass. Tiles to match existing on tile battens on tyvek pro V underlay on 19mm plywood or OSB boarding on 125x50 @ 400cc vertical studs filled with 120mm GA400 Celotex insulation Provide 12.5mm plasterboard and set internally. Provide 9mm masterboard where within 1m of boundary 3.45m Tiles to match existing on tile battens on tyvek pro V underlay on 19mm plywood or OSB boarding on 125x50 @ 400cc vertical studs filled with 120mm GA400 Celotex insulation Provide 12.5mm plasterboard and set internally. Provide 9mm masterboard where within 1m of boundary 5.85m 3.90m 2.70m 2.70m Provide code 4 lead flashing where dormer meets extg Provide code 4 lead flashing where dormer meets extg Provide inward opening french doors and juliet balcony in accordance with specialist design. Min height 1100mm Note height of doors max 1900mm to allow for roof construction Flank Elevation Rear Elevation Permitted development justification Gable Extension 7.61mx3.05mx3.90 divided by 4 =22.63m3 Dormer 2.70mx3.45mx5.85m divided by 2 = 27.246m3 Total= 49.876m3 Therefore less than 50 m/cubed allowed for semi detached property Meters 0 1 2 3 Client 4 Drawing Title Proposed Elevations 5m Job Title 1:100 A1 Mr and Mrs Batchelor Loft Conversion at402 Hook Road Chessington. KT9 1NA Scale Drawing No 1:100 16/44-04 Date Drawn By October 2016 KRS Designs
© Copyright 2026 Paperzz