Cobalt Chromium

CoCr
LEAR N
Ordering Information
Ø (mm)
*Nominal Pressure **Rated Burst Pressure – Do Not Exceed
PAS T
|
OB S ER VE
TH E
PR ES EN T
|
CRE ATE
TH E
FU TU R E
Product Specifications
Stent
LENGTH (mm)
9
TH E
13
15
18
23
28
33
Strut dimensions:
0.0034" (0.09 mm, width) x 0.0032" (0.08 mm, thickness)
Radiopacity:
Moderate
2.5
225-092-6A 225-132-6A 225-152-6A 225-182-6A 225-232-6A
-
-
Material:
L605 cobalt chromium alloy
2.75
227-092-6A 227-132-6A 227-152-6A 227-182-6A 227-232-6A
-
-
Side branch access:
4.5 mm
3.0
230-092-6A 230-132-6A 230-152-6A 230-182-6A 230-232-6A 230-282-6A 230-332-6A
Foreshortening:
< 2 %*
3.5
235-092-6A 235-132-6A 235-152-6A 235-182-6A 235-232-6A 235-282-6A 235-332-6A
Recoil:
< 5 %*
4.0
240-092-6A 240-132-6A 240-152-6A 240-182-6A 240-232-6A 240-282-6A 240-332-6A
Vessel wall coverage:
14 %*
Radial force (to 50% lumen collapse):
26 Psi*
Proximal Shaft (2.3F)
Hub
Radiopaque Markers
Rx Port
Transition Zone
Distal Shaft (2.9F)
Azule
Exit Markers
Catheter Working Length (138 cm)
Proximal shaft:
Hypotube
Nominal pressure:
9 atm
Rated burst pressure:
16 atm
Avg. burst pressure:
31 atm
Nominal crossing profile:
0.038" (0.97 mm)*
Catheter tip length:
4.25 mm
Max. guidewire OD:
0.014"
Shaft (prox/distal):
2.3F/2.9F
Guiding catheter compatibility:
5F (0.056" ID min)
cobalt chromium
*3.0 mm diameter stent
For more information please visit our website at www.OrbusNeich.com or contact us:
MARKETING & SALES HEADQUARTERS EMEA
Drs. W. van Royenstraat 5
3871 AN Hoevelaken
The Netherlands
Phone
+31.33.254.1150
Toll Free Phone
Fax
+31.33.254.1151
Toll Free Fax
00800.0254.1150*
00800.0254.1151*
* Only for Belgium, Denmark, France, Luxembourg, Netherlands, Norway, Sweden and UK.
© 2011 OrbusNeich. All rights reserved. Not available for sale in the USA. #G-70-0076 Rev01
Azule and OrbusNeich are Trademarks of OrbusNeich Medical, Inc. All data and photos on file. Illustrations are not to be considered as engineering drawings or photos.
c h r o m i u m
Uniquely Designed Thin Strut CoCr Stent for Dynamic Performance
Balloon Catheter
(0.014")
c o b a l t
CoCr
The Advanced Stent System behind the Genous Bio-engineered Cobalt Chromium Stent
S T E N T
Uniquely Designed Thin Strut CoCr Stent for Dynamic Performance
Cobalt Chromium when
Material Matters
The unique Dual Helix design provides natural conformability and
Thinner stent struts are better, as long as radial force is not compromised.
tremendous radial strength without compromising its extreme flexibility.
Thinner metal results in a lower profile, greater flexibility and reduced
up to 4.5 mm in diameter, to enable excellent side branch access
for effective bifurcation stenting and for maintaining patency of
restenosis, while maintaining adequate radiopacity.1
Dual Helix Design
side branches.
Unsurpassed Sidebranchability
CoCr
Squared Ends
– for lesion coverage and minimal foreshortening
Stent
Strut Thickness
Azule
0.0032" (=0.081 mm)
Integrity® and Driver®
0.0036" (=0.091mm)
Vision™
0.0032" (=0.081 mm)
1. Pache, J, et al., Journal of the American College of Cardiology, April, 2003, 16;41(8):1289-92. Intracoronary stenting and angiographic results:
strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.
Data on file
The Azule stent is made from the L605 cobalt chromium alloy, which has
no molybdenum and less nickel than 316L stainless steel or MP35N cobalt
Dual Helix Backbone
– for flexibility, radial strength and natural conformability
chromium alloy. Some patients are allergic to both nickel and molybdenum and
Proven Results when
Performance Matters
Extreme flexibility for ideal deliverabilty and conformability*
Lower is better
Mounted Stent
Flexibility (g/mm)
The Azule Cobalt Chromium Stent cells can be expanded to
Dual Helix when
Design Matters
1.1
1.0
0.9
0.8
0.7
0.6
0.5
Azule
Integrity
Vision
Driver
Tremendous radial strength for luminal scaffolding and
resistance to compressive forces*
Higher is better • To >50% collapse
30
Radial
Strength (psi)
Effective Bifurcation
Stenting when Side Branch
Access Matters
25
20
15
Azule
can develop restenosis as a result.2
Integrity
Vision
Driver
Low profile for excellent crossability and deliverabilty*
Lower is better
Azule
Sinusoidal Rings
– for scaffolding, coverage and support
cobalt chromium
Nickel Content
Molybdenum
L605
9 – 11 %
0%
316L
13 – 15 %
2.25 – 3.00 %
MP35N
33 – 37 %
9.00 – 10.50 %
2. Koster, R, et al., The Lancet, 2000, 356:1895-7. Nickel and Molybdenum Contact Allergies in Patients With Coronary In-stent Restenosis.
0.050
Crimped Stent
Profile (in)
Material
0.045
0.040
0.035
Azule
Integrity
Vision
Driver
* 3.0 mm diameter stent, data on file