Prospex® Plus XL PinholeTrimless accent downlight for Xicato modules 093+XL-13-XIC-TL Recessed adjustable pinhole trimless for Xicato led modules with 70mm diameter reflectors Die cast aluminium construction. Seperate die cast plaster kit for seamless installation Gear driven tilt and rotation. Trimmed versions available Hot aiming simplifies focussing while lamp is on. Aiming remains locked in focus throughout re-lamping. Deep regressed lamp for minimal glare. IP44 as standard. Ref Number: 093+XL-13-XIC-TL-WH 093+XL-13-XIC-TL-BK White (RAL 9010) Black (RAL 9005) Module Type max output max wattage max driver max depth X XTM 3000lm 29.3w 1050mA 171mm XTA 2000lm 26.4w 1050mA 135mm XTV83 3000lm 29.3w 1050mA 171mm XTV98 2000lm 26.4w 1050m 135mm Module Type max output max wattage max driver max depth X XTM9 2000lm 30.2w 1050mA 171mm XTA9 1300lm 24.3w 1050mA 171mm XTV983 2000lm 30.2w 1050mA 171mm XTV998 1300lm 24.3w 1050mA 171mm max. depth is based on max lumen output with the deepest reflector @ ambient temperature 35°C. other combinations may vary Lamp quantity Lamp Adjustable Aperture Overall dimension Required depth First fix requirement* Ceiling cut out Ceiling thickness Ingress protection** Dimming options*** 1 Xicato range 45° 75mm Ø 141mm Ø Height +25mm minimum clearance Yes 140mm Ø 25mm MAX IP44 Phase/DALI/1-10v Cut out 140mm Ø www.lucent-lighting.com *First Fix requirement. Luminaire comprised of fixture body with separate front plate and trimless installation kit, which is to be fitted to the ceiling before skimming. Ensure correct alignment of the installation kit before the ceiling is skimmed & final assembly (see luminaire installation instructions for details). **IP Rating. Tested from underside of the ceiling. ***Dimming. Whilst Lucent can offer the majority of its luminaires with various dimming options, it remains the responsibility of the specifier/installer to check and ensure compatibility of any control equipment used. Additional cabling may be required depending on the dimming protocol specified. ****Active Heatsink. Fixture with fan cooled heatsink to allow for larger output modules. Requires an additional 12v supply for the fan. Enssure the correct driver is specified or an additional power supply is provided. It is the policy of Lucent Lighting to continually review and improve its products and therefore reserve the right to change any details of product or withdraw specifications without prior notice. Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned by or licensed to Lucent Lighting UK Ltd. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: [email protected] t: +44 (0)20 8442 0880 Fitting Ref Europe China Quantity Russia Lucent Xicato LED Modules with 70mmØ Reflectors Module Code Builder. Lumen outputs shaded in gray are available with passive heatsink for use with this luminaire type. Higher lumen outputs may be available with active cooling. Please consult Lucent Lighting for details. XTM XTA XTV XTM9 XTA9 XTV9 www.lucent-lighting.com 5000lm 4000lm 3000lm 2000lm CRI 83 83 83 83 83 98 98 98 83 98 83 98 83 98 83 83 83 83 83 98 98 98 83 98 83 98 83 98 1300lm Type Lumen output at maximum drive current. 700lm Module Colour Reflector (70Ø) Beam angle (°) temp (K) 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 30 30 30 30 30 30 30 30 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 30 30 30 30 30 30 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 23/42/57 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 10/24/41/64 Max. Drive Wattage Current (mA) 700mA 700mA 1050mA 1400mA 1400mA 700mA 1050mA 1050mA 700mA 700mA 1050mA 1050mA 1050mA 1050mA 1400mA 1400mA 700mA 700mA 1050mA 700mA 1050mA 1400mA 700mA 700mA 700mA 1050mA 1050mA 1400mA (W) 11.7 19.5 29.3 39.1 46.8 15.6 26.4 34.1 11.7 15.6 19.5 26.4 29.3 34.1 39.1 46.8 7.8 15.6 30.2 9.7 24.3 42.1 7.8 9.7 15.6 24.3 30.2 42.1 7 Xictao Module Type Required. Heatsink. (Blank) - Passive Heatsink AF - Active Heatsink (Refer to luminaire speification sheet) Lumen Output. (Refer to luminaire speification sheet for maximum permitted output) Colour temperature required * Separate die cast plaster in kit for plaster ceilings. ** Tested from ceiling underside. To specify IP54; add '-IP' to end of code. *** Dimming options depend on driver (toimprove be separately policy of Lucent Lighting to continually review and its products ordered/specified). and therefore reserve the right to change any details of product or It is the withdraw specifications prior notice. Some controlwithout methods may require additional cabling Diameter of reflector (70mm) Beam angle required. Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned or licensed to Lucent Lighting UK Ltd. Lucent reserve the right to change any details, dimensions colours etc without priorbynotice. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: [email protected] t: +44 (0)20 8442 0880 Fitting Ref Quantity Lucent Xicato LED Modules with 70mmØ Reflectors Module Code Builder. Indicates modules available in the range. Refer to the luminaire specification for maximum modules permitted. XTB 5000lm 4000lm 3000lm 2000lm CRI 95 95 1300lm Type Lumen output at maximum drive current. 700lm Module Colour Reflector (70Ø) Max. Drive Wattage temp (K) 27 27 Beam angle (°) Current (mA) 700mA 1050mA (W) 15.6 26.4 23/42/57 23/42/57 7 Xictao Module Type Required. Lumen Output. (Refer to luminaire speification sheet for maximum permitted output) Diameter of reflector (70mm) Colour temperature required Beam angle required. www.lucent-lighting.com * Separate die cast plaster in kit for plaster ceilings. ** Tested from ceiling underside. To specify IP54; add '-IP' to end of code. *** Dimming options depend on driver (toimprove be separately policy of Lucent Lighting to continually review and its products ordered/specified). and therefore reserve the right to change any details of product or It is the withdraw specifications prior notice. Some controlwithout methods may require additional cabling Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned or licensed to Lucent Lighting UK Ltd. Lucent reserve the right to change any details, dimensions colours etc without priorbynotice. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: [email protected] t: +44 (0)20 8442 0880 Fitting Ref Quantity
© Copyright 2024 Paperzz