1 OF 6 Installation Instructions MX LED Wall Wash ! WARNING Risk of electrical shock. Disconnect power before servicing or installing luminaire. ! WARNING Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. ! WARNING Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling. IS-R1026R8 IMPORTANT SAFETY INSTRUCTIONS –– Read all installation instructions before installing. It is important to save these instructions. –– Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty. –– Connectors on modules and approved housings are keyed for specific voltage combinations; do not force or attempt to bypass connectors. –– Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module, warnings of installation near combustible materials and/or insulation. –– Turn off power at circuit breaker before attempting to install or perform maintenance on the fixtures. –– Be sure to connect ground wire to prevent electric shock or other potential hazards. –– The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved. –– Do not block the trim aperture as this may cause unsafe operating conditions. –– WARNING: RISK OF FIRE. Non-IC fixture requires that insulation must be kept at least 3” away from all sides of the fixture. Minimum of 90°C supply conductors. Consult a qualified electrician before installation. WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties. 1 HOUSING INSTALLATION: 1. Mount fixture housing according to ceiling type. -- Universal mounting bracket has slot openings for C-channel, flat bar, and 1/2” EMT; secure to joist or grid using fasteners or wire. C-channel hangers are recommended for T-Bar ceilings, install with notches facing down to engage T-Bar grid. 2 MOUNTING: Bar hanger mounting brackets offer several height choices depending on installation requirements. C-Channel, EMT and other joist bars can be ordered for various ceiling types. Housing lid Universal mounting bracket I100 (C-Channel) I200 (Flat Bar) I400 (Wood Joist) EMT 3 WIRING Metal conduit knockout Junction box cover plate 4 ELECTRICAL CONNECTIONS: 1. Make electrical connections through desired knockout for conduit or Romex® cable. Use only UL listed connectors. 2. Connect black wire from fixture to black (HOT) supply wire, white wire from fixture to white (NEUTRAL) supply wire and connect the ground from fixture to green (GROUND) supply wire. Use UL listed connectors or wire nuts to make the connections (provided by others). Connect dimming wires if applicable, see page 4. 3. Close and lock junction box door ensuring all wire connections and wire are contained within. LED Module Note: Insulation detector not present on IC or CP housings Black Red Hot Neutral Ground Junction box INSTRUCTIONS L/M-04132016 P-1 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. 120V / 277V connection wires 2 OF 6 IS-R1026R8 HOUSING HEIGHT ADJUSTMENT: Loosen wingnut to make adjustments so that housing collar is flush with ceiling line. 5 6 TRIMLESS INSTALLATION (A): 1. Screw perforated mud plate to housing with #8 drywall screws (by others). 2. Reinstall plenum cover to prevent paint damage to fixtures. 3. Apply joint compound over perforated mud plate and feather out accordingly. Wingnut Mud plate Ceiling line Plenum cover Housing collar TRIMLESS INSTALLATION (B): 1. Screw in mud plate into drywall. Screws 7 Note: Do not remove plenum cover until mud and paint has been applied MODULE INSTALLATION: 1. Ensure bracket is at a 0° angle. 2. Check that power is off at breaker, hot plugging may damage LEDs. 3. Connect female quick connect from housing to male quick connect on module. 4. Snap module into channel and confirm module sits parallel to ceiling line and is securely fastened into housing. Quick connect 8 Channel Screw in mud plate into drywall ADJUSTING HORIZONTAL ADJUSTMENT: 1. Loosen thumb screw to allow fixture to adjust horizontally. 2. Tighten thumb screw to lock horizontal rotation. 3. Trim alignment sticker must be pointed to wall. 9 10 ADJUSTING WALL WASH POSITION: 1. Loosen knurled head thumb screw to allow fixture to slide into position. 2. Slide wall wash module and bracket away from trim location label. 3. Tighten knurled head thumb screw to lock wall wash position, by hand or with 2.5mm hex key. Trim label Thumb screw (Horizontal locking) INSTRUCTIONS L/M-04132016 P-2 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. Thumb screw (Wall wash locking) 3 OF 6 IS-R1026R8 TRIM INSTALLATION (APPLIES TO ROUND HOUSING ONLY): 1. Position trim alignment label to trim location location label on the housing collar. 2. Snap trim into the housing. 3. Luminaire will direct wall washing light in the direction of the trim alignment label. 11 Trim location label Trim alignment label TRIM INSTALLATION (APPLIES TO SQUARE HOUSING ONLY): 1. Position trim alignment label to trim location label on the housing collar. 2. To install trim, rotation plate must be parallel with the housing. Note: Trim will not lineup at any other angle than 90º increments. Rotation plate Trim location label Trim alignment label INSTRUCTIONS L/M-04132016 P-3 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. Housing 4 OF 6 IS-R1026R8 DRIVER REPLACEMENT: 1. Adjust wall wash assembly by pulling forward to assure clearance. 2. Unscrew all four 2mm allen key head machine screws on both sides. 3. Remove vertical adjustment assembly by tilting the assembly to assure clearance. 4. Unsnap driver plate from junction box. Disconnect quick connect from driver plate and input quick connect. 5. Guide driver/driver plate/module quick connect through opening. 6. Replace new driver on driver plate and replace module quick connect. Driver plate Module quick connect Wall wash assembly Allen head machine screws Ceiling opening Accessories and Options LED MODULE KIT Example: MXMG2L02712 SERIES WATTAGE CCT / CRI OPTIC MXMG2 (MX G2 Module) L0 L1 L2 L3 27 279 30 309 35 359 41 419 CA35 CW30 12 (12º Spot) (10 Watts) (16 Watts) (20 Watts) (26 Watts) MECHANISM KIT Converts between Downlight or Adjustable ITEM NUMBER IP-MXDN (MX Downlight Mechanism) IP-MXAJ (MX Adjustable Mechanism) INSTRUCTIONS L/M-04132016 P-4 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. (2700K / 82 CRI) (2700K / 92 CRI) (3000K / 82 CRI) (3000K / 92 CRI) (3500K / 82 CRI) (3500K / 92 CRI) (4100K / 82 CRI) (4100K / 92 CRI) (Class A 3500K) (CrispWhite 3000K) Input quick connect 5 OF 6 Dimming Compatibility 0-10V DIMMING (10% Dimming, eldoLED 1%, eldoLED 0.1%) -- 120V/277V -- Consult dimming manufacturer for installation instructions and power packs BLACK COMPATIBLE DIMMERS Manufacturer Part Number(s) HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V, FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V Leviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212 Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC Lutron DVTV, NTFTV Synergy ISD BC 120/277 LUTRON ECOSYSTEM® DIMMING -- 120V or 277V -- Dims down to 1% or 5% -- Consult dimming manufacturer for installation instructions INPUT WHITE RED - POSITIVE DRIVER GREEN 0-10V DIMMER ECO SYSTEM CONTROL (BY OTHERS) BLACK - NEGATIVE LED LIGHT ENGINE VIOLET (+) GREY (-) BLACK WHITE RED - POSITIVE DRIVER GREEN BLACK - NEGATIVE LED LIGHT ENGINE COMPATIBLE DIMMERS Product EcoSystem Part Number(s) CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum ECO SYS BUS VIOLET (E1) VIOLET (E2) LUTRON HI-LUME® DIMMING -- 120V or 277V -- Dims down to 1% -- Consult dimming manufacturer for installation instructions COMPATIBLE DIMMERS Product Part Number(s) NovaT NTF-10, NTF-103P, NTF-103P-277, NTF-10-277 Nova NF-10, NF-103P, NF-103P-277, NF-10-277 VareoVF-10 Skylark SF-10P, SF-12P-277, SF-12P-277-3, SF-103P Diva DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277 Ariadni AYF-103P, AYF-103P-277 ViertiVTF-6AM Maestro MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277 Maestro Wireless MRF2-F6AN-DV Spacer System SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277 Lyneo LXF-103PL, LXF-103PL-277 Radio RA 2 RRD-F6AN-DV HomeWorks QS HQRD-F6AN-DV 3-WIRE CONTROL (BY OTHERS) BLACK WHITE ORANGE GREEN RED - POSITIVE DRIVER BLACK - NEGATIVE LED LIGHT ENGINE ELV DIMMING -- 120V only -- Dims down to 1% -- Consult dimming manufacturer for installation instructions COMPATIBLE DIMMERS MX MODULE DIMS DOWN TO Product Part Number(s) L0 (10W) L1 (16W) L2 (20W) L3 (26W) Leviton IPI06-1LZ - 1%1%1% Leviton 6633-P 1%1%1% Lutron DVCL-153P 1%1%1%1% LutronS600P 3% 1% 2% 2% CooperDLC03P - 1% 1% 2% Cooper DAL06P - 1%1%1% INSTRUCTIONS L/M-04132016 P-5 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. 120V INPUT FROM DIMMER BLACK WHITE GREEN RED - POSITIVE DRIVER BLACK - NEGATIVE LED LIGHT ENGINE 6 OF 6 INTENSE LIGHTING WARRANTY INTERIOR LED PRODUCTS: 10-YEAR LIMITED WARRANTY Intense Lighting warrants the LED electronics and components of its properly installed INTERIOR LED products listed below, to be free of defects in material and workmanship in normal use, for a period of 10 years from the date of our shipment or 50,000 hours of operation, whichever occurs first. Intense Lighting will repair or replace, at its option, any warranted product returned to it that it determines to be defective. Usage documentation may be requested to validate hours. This limited warranty does not include installation or removal, nor does it extend to the LED drivers which are warranted for five years. For the first year after the date of shipment, Intense Lighting will provide personnel to make field repairs for defective recessed fixtures only. Track fixtures must be sent back to factory for testing and evaluation. In addition to complete failure, defects include lumen depreciation to levels below 70% of initial lumen output within warranty period and/or color shift beyond that which is set forth in the Energy Star Program Requirements for SSL – Version 1.1 within warranty period. Defects do not include improper installation or operation, alterations, power surges or overheating due to external conditions. To receive credit for defective merchandise, product must undergo quality inspection prior to the processing of credit. If the product is found defective, you will be issued a credit. Product in good working condition will not receive a credit. Please inform your accounting department not to short pay or issue any debits to our company regarding a return. Testing and evaluation can take approximately 1-2 weeks based on quantity. At that time you will be notified if credit is granted for your warranty return. THE ABOVE EXPRESS WARRANTY STATES THE FULL AND COMPLETE OBLIGATION OF INTENSE LIGHTING. ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE TERM OF THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES WILL INTENSE LIGHTING ACCEPT LIABILITY FOR ANY CONSEQUENTIAL SPECIAL OR INDIRECT DAMAGES WHETHER ARISING OUT OF CONTRACT, TORT, OR STRICT LIABILITY. INSTRUCTIONS L/M-04132016 P-6 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
© Copyright 2025 Paperzz