Installation Instructions MX LED Wall Wash

1 OF 6
Installation Instructions
MX LED Wall Wash
! WARNING
Risk of electrical shock. Disconnect power
before servicing or installing luminaire.
! WARNING
Risk of injury or damage. Luminaire will
fail if not installed properly. Follow
installation instructions.
! WARNING
Risk of injury. Wear safety glasses and
gloves during installation and servicing.
Allow ample time to cool before handling.
IS-R1026R8
IMPORTANT SAFETY INSTRUCTIONS
–– Read all installation instructions before installing. It is important to save these instructions.
–– Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with
power on, could damage the LEDs and is not covered by warranty.
–– Connectors on modules and approved housings are keyed for specific voltage combinations; do not force or attempt to bypass
connectors.
–– Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module,
warnings of installation near combustible materials and/or insulation.
–– Turn off power at circuit breaker before attempting to install or perform maintenance on the fixtures.
–– Be sure to connect ground wire to prevent electric shock or other potential hazards.
–– The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and
local codes by a person familiar with the construction and operation of the product and the hazards involved.
–– Do not block the trim aperture as this may cause unsafe operating conditions.
–– WARNING: RISK OF FIRE. Non-IC fixture requires that insulation must be kept at least 3” away from all sides of the fixture.
Minimum of 90°C supply conductors. Consult a qualified electrician before installation.
WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a
violation of N.E.C 110-3(B) and voids all warranties.
1
HOUSING INSTALLATION:
1. Mount fixture housing according to ceiling type.
-- Universal mounting bracket has slot openings for C-channel, flat bar, and 1/2” EMT;
secure to joist or grid using fasteners or wire. C-channel hangers are recommended for
T-Bar ceilings, install with notches facing down to engage T-Bar grid.
2
MOUNTING:
Bar hanger mounting brackets offer several height choices depending on installation
requirements. C-Channel, EMT and other joist bars can be ordered for various ceiling types.
Housing lid
Universal mounting
bracket
I100 (C-Channel)
I200 (Flat Bar)
I400 (Wood Joist)
EMT
3
WIRING
Metal conduit
knockout
Junction box
cover plate
4
ELECTRICAL CONNECTIONS:
1. Make electrical connections through desired knockout for conduit or Romex® cable. Use
only UL listed connectors.
2. Connect black wire from fixture to black (HOT) supply wire, white wire from fixture to
white (NEUTRAL) supply wire and connect the ground from fixture to green (GROUND)
supply wire. Use UL listed connectors or wire nuts to make the connections (provided by
others). Connect dimming wires if applicable, see page 4.
3. Close and lock junction box door ensuring all wire connections and wire are contained
within.
LED Module
Note: Insulation detector not
present on IC or CP housings
Black
Red
Hot
Neutral
Ground
Junction box
INSTRUCTIONS L/M-04132016 P-1
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
120V / 277V
connection
wires
2 OF 6
IS-R1026R8
HOUSING HEIGHT ADJUSTMENT:
Loosen wingnut to make adjustments so that housing collar is flush with ceiling line.
5
6
TRIMLESS INSTALLATION (A):
1. Screw perforated mud plate to housing with #8 drywall screws (by others).
2. Reinstall plenum cover to prevent paint damage to fixtures.
3. Apply joint compound over perforated mud plate and feather out accordingly.
Wingnut
Mud plate
Ceiling line
Plenum cover
Housing
collar
TRIMLESS INSTALLATION (B):
1. Screw in mud plate into drywall.
Screws
7
Note: Do not remove plenum cover until mud and
paint has been applied
MODULE INSTALLATION:
1. Ensure bracket is at a 0° angle.
2. Check that power is off at breaker, hot plugging may damage LEDs.
3. Connect female quick connect from housing to male quick connect on module.
4. Snap module into channel and confirm module sits parallel to ceiling line and is
securely fastened into housing.
Quick connect
8
Channel
Screw in mud plate into drywall
ADJUSTING HORIZONTAL ADJUSTMENT:
1. Loosen thumb screw to allow fixture to adjust horizontally.
2. Tighten thumb screw to lock horizontal rotation.
3. Trim alignment sticker must be pointed to wall.
9
10
ADJUSTING WALL WASH POSITION:
1. Loosen knurled head thumb screw to allow fixture to slide into position.
2. Slide wall wash module and bracket away from trim location label.
3. Tighten knurled head thumb screw to lock wall wash position, by hand or with 2.5mm
hex key.
Trim label
Thumb screw
(Horizontal locking)
INSTRUCTIONS L/M-04132016 P-2
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
Thumb screw
(Wall wash locking)
3 OF 6
IS-R1026R8
TRIM INSTALLATION (APPLIES TO ROUND HOUSING ONLY):
1. Position trim alignment label to trim location location label on the housing collar.
2. Snap trim into the housing.
3. Luminaire will direct wall washing light in the direction of the trim alignment label.
11
Trim location label
Trim
alignment
label
TRIM INSTALLATION (APPLIES TO SQUARE HOUSING ONLY):
1. Position trim alignment label to trim location label on the housing collar.
2. To install trim, rotation plate must be parallel with the housing. Note: Trim will not lineup at any other angle than 90º increments.
Rotation
plate
Trim location label
Trim alignment label
INSTRUCTIONS L/M-04132016 P-3
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
Housing
4 OF 6
IS-R1026R8
DRIVER REPLACEMENT:
1. Adjust wall wash assembly by pulling forward to assure clearance.
2. Unscrew all four 2mm allen key head machine screws on both sides.
3. Remove vertical adjustment assembly by tilting the assembly to assure clearance.
4. Unsnap driver plate from junction box. Disconnect quick connect from driver plate and input quick connect.
5. Guide driver/driver plate/module quick connect through opening.
6. Replace new driver on driver plate and replace module quick connect.
Driver plate
Module
quick
connect
Wall wash
assembly
Allen head machine
screws
Ceiling
opening
Accessories and Options
LED MODULE KIT
Example: MXMG2L02712
SERIES
WATTAGE
CCT / CRI
OPTIC
MXMG2 (MX G2 Module)
L0
L1
L2
L3
27
279
30
309
35
359
41
419
CA35
CW30
12 (12º Spot)
(10 Watts)
(16 Watts)
(20 Watts)
(26 Watts)
MECHANISM KIT
Converts between Downlight or Adjustable
ITEM NUMBER
IP-MXDN (MX Downlight Mechanism)
IP-MXAJ (MX Adjustable Mechanism)
INSTRUCTIONS L/M-04132016 P-4
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
(2700K / 82 CRI)
(2700K / 92 CRI)
(3000K / 82 CRI)
(3000K / 92 CRI)
(3500K / 82 CRI)
(3500K / 92 CRI)
(4100K / 82 CRI)
(4100K / 92 CRI)
(Class A 3500K)
(CrispWhite 3000K)
Input quick
connect
5 OF 6
Dimming Compatibility
0-10V DIMMING (10% Dimming, eldoLED 1%, eldoLED 0.1%)
-- 120V/277V
-- Consult dimming manufacturer for installation instructions and power packs
BLACK
COMPATIBLE DIMMERS
Manufacturer
Part Number(s)
HUNT
PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120,
PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V,
PS-010-3W-IV-277V, PS-010-3W-WH-277V,
FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V,
FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V,
FD-010-120V, FD-010-277V
Leviton
Leviton Centura Fluorescent Control System,
IllumaTech™ IP7 Series, DPSPE-212
Lightolier
ZP600FAM120, MP1500FAM120, V2000FAMU
Lithonia
LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC
Lutron
DVTV, NTFTV
Synergy
ISD BC 120/277
LUTRON ECOSYSTEM® DIMMING
-- 120V or 277V
-- Dims down to 1% or 5%
-- Consult dimming manufacturer for installation instructions
INPUT
WHITE
RED - POSITIVE
DRIVER
GREEN
0-10V
DIMMER
ECO
SYSTEM
CONTROL
(BY OTHERS)
BLACK - NEGATIVE
LED LIGHT
ENGINE
VIOLET (+)
GREY (-)
BLACK
WHITE
RED - POSITIVE
DRIVER
GREEN
BLACK - NEGATIVE
LED LIGHT
ENGINE
COMPATIBLE DIMMERS
Product
EcoSystem
Part Number(s)
CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM,
EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum
ECO SYS
BUS
VIOLET (E1)
VIOLET (E2)
LUTRON HI-LUME® DIMMING
-- 120V or 277V
-- Dims down to 1%
-- Consult dimming manufacturer for installation instructions
COMPATIBLE DIMMERS
Product
Part Number(s)
NovaT
NTF-10, NTF-103P, NTF-103P-277, NTF-10-277
Nova
NF-10, NF-103P, NF-103P-277, NF-10-277
VareoVF-10
Skylark
SF-10P, SF-12P-277, SF-12P-277-3, SF-103P
Diva
DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277
Ariadni
AYF-103P, AYF-103P-277
ViertiVTF-6AM
Maestro
MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277
Maestro Wireless MRF2-F6AN-DV
Spacer System
SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277
Lyneo
LXF-103PL, LXF-103PL-277
Radio RA 2
RRD-F6AN-DV
HomeWorks QS
HQRD-F6AN-DV
3-WIRE
CONTROL
(BY OTHERS)
BLACK
WHITE
ORANGE
GREEN
RED - POSITIVE
DRIVER
BLACK - NEGATIVE
LED LIGHT
ENGINE
ELV DIMMING
-- 120V only
-- Dims down to 1%
-- Consult dimming manufacturer for installation instructions
COMPATIBLE DIMMERS
MX MODULE DIMS DOWN TO
Product Part Number(s) L0 (10W)
L1 (16W)
L2 (20W)
L3 (26W)
Leviton
IPI06-1LZ - 1%1%1%
Leviton
6633-P 1%1%1% Lutron
DVCL-153P 1%1%1%1%
LutronS600P
3%
1%
2%
2%
CooperDLC03P
-
1%
1%
2%
Cooper
DAL06P
- 1%1%1%
INSTRUCTIONS L/M-04132016 P-5
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
120V INPUT
FROM
DIMMER
BLACK
WHITE
GREEN
RED - POSITIVE
DRIVER
BLACK - NEGATIVE
LED LIGHT
ENGINE
6 OF 6
INTENSE LIGHTING WARRANTY
INTERIOR LED PRODUCTS: 10-YEAR LIMITED WARRANTY
Intense Lighting warrants the LED electronics and components of its properly installed INTERIOR LED products listed
below, to be free of defects in material and workmanship in normal use, for a period of 10 years from the date of our
shipment or 50,000 hours of operation, whichever occurs first. Intense Lighting will repair or replace, at its option, any
warranted product returned to it that it determines to be defective. Usage documentation may be requested to validate
hours. This limited warranty does not include installation or removal, nor does it extend to the LED drivers which are
warranted for five years. For the first year after the date of shipment, Intense Lighting will provide personnel to make
field repairs for defective recessed fixtures only. Track fixtures must be sent back to factory for testing and evaluation.
In addition to complete failure, defects include lumen depreciation to levels below 70% of initial lumen output within
warranty period and/or color shift beyond that which is set forth in the Energy Star Program Requirements for SSL –
Version 1.1 within warranty period.
Defects do not include improper installation or operation, alterations, power surges or overheating due to external
conditions. To receive credit for defective merchandise, product must undergo quality inspection prior to the processing
of credit. If the product is found defective, you will be issued a credit. Product in good working condition will not receive
a credit. Please inform your accounting department not to short pay or issue any debits to our company regarding a
return. Testing and evaluation can take approximately 1-2 weeks based on quantity. At that time you will be notified if
credit is granted for your warranty return.
THE ABOVE EXPRESS WARRANTY STATES THE FULL AND COMPLETE OBLIGATION OF INTENSE LIGHTING. ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE
TERM OF THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES WILL INTENSE LIGHTING ACCEPT LIABILITY FOR ANY
CONSEQUENTIAL SPECIAL OR INDIRECT DAMAGES WHETHER ARISING OUT OF CONTRACT, TORT, OR STRICT LIABILITY.
INSTRUCTIONS L/M-04132016 P-6
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.