EN0H-0468GE25 R0516 Water Metering S110 Singlejet Water Meters DN15 and DN20 for Cold and Warm Potable Water Applications APPLICATION Honeywell S110 singlejet water meters are used for sub metering of cold or warm water in residential drinking water systems. They are available in sizes DN15 and DN20 and have a mechanical counter. They can be retrofitted with a clip on MBus and pulse out combimodule for integration into remote readout networks. APPROVALS • MID 2014/32/EU (based on OIML R49, EN14154) • ACS, UBA, KTW SPECIAL FEATURES • Retrofittable with wired M-Bus / pulse out communication TECHNICAL DATA Media Standard medium: Connections Nominal sizes: Nominal flow Q3: Operating temperatures Medium temperature: Temperature class: Ambient temperature: Specifications Water pressure class: Pressure loss class: Environmental class: Mechanical class: Electromagnetic class: Measuring process: Display: Display unit: Display range: Increments: Acceptable error: Installation position: Optional interfaces: Drinking water DN15 - DN20 2.5 - 4 m³/h Cold water: 0.1 - 30 °C Warm water: 30 - 90 °C Cold water: T30 Warm water: T30/90 5 - 55 °C MAP16 (max. 16bar) ΔP63 (max. 63kPa) B M1 E1 Mechanical counter with singlejet volume measurement 8-digit roller counter m3 105 with four decimal places 0.00005 m3 ±2% at Q3 for water ≤30 °C ±3% at Q3 for water >30 °C H, V (horizontal, vertical) Wired M-Bus and pulse out Product Specification Sheet • EN0H-0468GE25 R0516 • Subject to change 1 S110 - Singlejet Water Meters CONSTRUCTION Overview 1 2 3 4 5 6 7 8 9 METHOD OF OPERATION Counter • The meter can be read from a single line eight-digit roller counter with m³. The counter unit can be rotated for better readibility. Components Roller counter Serial number Inlet Outlet Approval number and specifications Cover of module interface Target CE marking and production year Flow arrow Materials Plastic Brass Brass Plastic - master or, in case the meter is not attached to an M-Bus, with an M-Bus hardware tool, for example the Relay Micro-Master. Flow Sensor • The singlejet technology of the flow sensor combines high measuring accuracy with long term stability. The impeller is connected to the counter by a magnetic coupling. The flow sensor has a sieve on the inlet to stop particles from entering the measuring chamber. Interfaces • S110 water meters can be retrofitted with the TMP-F clip on communication module for remote readout applications. The TMP-F module provides M-Bus and pulse out options. Both options can be operated in parallel. The module is clipped onto the meter in the field and can be fitted at any time, also when the meter is already operating. The module is supplied ready to use. Programming is required in case default values should be changed. M-Bus / pulse out combination module • M-Bus / pulse out combination module: The M-Bus / pulse out combination module has cables for wiring to an M-Bus and to a pulse counter. The M-Bus module is according to EN13757-3 with primary and secondary addressing. Programming is done via the M-Bus master. M-Bus address changes are done with the M-Bus master configuration software, for example MBConf. Pulse module configuration is also done via the M-Bus TRANSPORTATION AND STORAGE Keep parts in their original packaging and unpack them shortly before use. The following parameters apply during transportation and storage: Parameter Environment: Min. ambient temperature: Max. ambient temperature: Min. ambient relative humidity: Max.ambient relative humidity: Value clean, dry and dust free -20 °C 70 °C 5%* 95 % * *non condensing 2 Product Specification Sheet • EN0H-0468GE25 R0516 • Subject to change S110 - Singlejet Water Meters INSTALLATION GUIDELINES TECHNICAL CHARACTERISTICS Setup requirements Flow Data • Calming legs before or after S110 water meters are not required unless the meter is installed before or after a pump or motorised valve. In that case a calming leg of 5 x DN is required in front of or of 3 x DN behind the meter. • All sizes may be installed in both horizontal and vertical position. • S110 water meters must be installed with dial facing upwards or sidewards but not beneath the horizontal plane. • Avoid installation at highest point of system or system part as air may be trapped in meter • It is recommended to place a valve before and after the meter for easy replacement. • During measurement meter must be completely filled with water Nominal size diameter: Flow rates Minimum (Q1): Transitional (Q2): Permanent (Q3): Overload (Q4): Dynamic range (Q3/Q1): Additional flow data Starting flow: DN 15, 20 20 l/h l/h m3/h m3/h 63 100 2.5 3.125 R40 100 160 4 5 R40 7 10 l/h Sizing • S110 water meters should be selected in such a way that permanent system flow rates are between transition flow rate (Q2) and permanent flow rate (Q3) • The flow rate may not drop below minimum (Q1) or exceed overload flow rate (Q4) at any time DIMENSIONS Overview Note: Parameter Nominal size diameter: Meter thread G: Weight: Dimensions: All dimensions in mm unless stated otherwise. Note: Values DN Inch kg L H1 H2 ØD 15 G3/4 " 0.3 110 58 71 20 G1 " 0.4 130 58 74 64 Weight is without fittings or any other accessories. ORDERING INFORMATION The following tables contain all the information you need to make an order of an item of your choice. When ordering, please always state the type, the ordering or the part number. Options Nominal size diameter: DN 15 15 20 20 Flow rate: Length: Ordering Number Q3 2.5 m³/h 2.5 m³/h 2.5 m³/h 4 m³/h 80 mm 110 mm 130 mm 130 mm for cold water LA0003518 LA0003519 LA0005650 LA0003521 for warm water LA0003814 LA0003816 LA0005651 LA0003818 S110 Scope of Delivery • S110 water meter • Two paper sealings • Installation and setup instructions Product Specification Sheet • EN0H-0468GE25 R0516 • Subject to change 3 S110 - Singlejet Water Meters Accessories Description EWA1 Connection set V4020 V4000 TMP-F Environmental & Energy Solutions Honeywell GmbH Hardhofweg 74821 MOSBACH GERMANY Phone: (49) 6261 810 Fax: (49) 6261 81309 http://ecc.emea.honeywell.com Dimension Part No. Set of two union nuts, two sealings and two externally threaded brass tailpieces (one pack per meter required) – sealable with locking wire 1/ " x 3/ " For DN15 EWA1500035 2 4 3/ " x 1" For DN20 EWA1500042 4 Alwa shutoff valves with internal threads 1/ " internal For DN15 V4020YY015 2 threads 3/ " internal For DN20 V4020YY020 4 threads Alwa shutoff valves with internal threads and closed body 3/ " internal For DN20 4 threads Wired M-Bus / pulse out combination module For DN15-20, available approx. Q3/2016 Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell GmbH EN0H-0468GE25 R0516 Subject to change © 2016 Honeywell GmbH V4000YY020
© Copyright 2026 Paperzz