Upgrade and Configuration Guide

Upgrade and Configuration Guide
3VR SmartRecorder, S-Series
The basic unit of system load is the Resource Unit (RU). Each 3VR SmartRecorder model has a different maximum RU capacity. For
the S-Series SmartRecorder, the following RU and Channel Capacity limits are enforced:
S-Series Resource Unit (RU) and Camera Capacity Table
S-Series
SmartSearch NVR
models
(SRS-N30- XXXX)
Maximum RU Capacity
8
Maximum Camera/Channel Capacity
(Analog and IP up to 704x576; NVR is IP
capacity only)
8
4-channel hybrid
models
(SRS-0430- XXXX)
8-channel hybrid
models
(SRS-0830- XXXX)
16-channel hybrid
models
(SRS-1630- XXXX)
4
8 (4 analog max)
12 (8 analog max)
16 (16 analog max)
Resource Units can be used for included and optional features, up to the Maximum RU Capacity limit.
Feature Resource Unit (RU) Requirements Table
Feature
Maximum Allowed on S-Series
(subject to RU capacity limit)
RU Required for each
Local OpCenter
1
2
Advanced Video Analytics Channels
(Facial Surveillance, LPR, etc.)
4
1 per analog camera or 704x576 region in an IP camera
8
0.5
Up to 2 MP
2 (4 on NVR)
2
Above 2 MP
1 (2 on NVR)
3
Up to 704x576
4 (8 on NVR)
1
Up to 2 MP
1 (2 on NVR)
4
Above 2 MP
0 (1 on NVR)
6
IP Cameras (MJPEG* or dual-stream**)
Up to 704x576
IP Cameras (MPEG4 or H.264 only)
Multiple streams from a camera should be treated as separate cameras, and require RUs that correspond with their resolution. For
example, 3 VGA virtual regions from the same 2MP camera are considered 3 separate IP cameras.
Cameras that contain multiple physical cameras (the Arecont™ 8180 or 8360, for example) should be treated as multiple cameras.
*
* *For MJPEG-only cameras, subject to maximum limit of 50 MP/s.
**Dual-stream cameras (most cameras are) can supply both MJPEG for motion detection
and analysis as well as a MPEG4 or H.264 stream for storage. This is preferred.
Upgrade and Configuration Guide
3VR SmartRecorder, P-Series
The basic unit of system load is the Resource Unit (RU). Each 3VR SmartRecorder model has a different maximum RU capacity. For
the P-Series SmartRecorder, the following RU and Channel Capacity limits are enforced:
P-Series Resource Unit (RU) and Camera Capacity Table
P-Series
SmartSearch NVR
models
(SRP-N80- XXXX)
Maximum RU Capacity
20
Maximum Camera/Channel Capacity
(Analog and IP up to 704x576; NVR is IP
capacity only)
32
16-channel hybrid
models
(SRP-1680- XXXX)
24-channel hybrid
models*
(SRP-2480- XXXX)
32-channel hybrid
models
(SRP-3280- XXXX)
16
32 (16 analog max)
32 (32 analog max)
Resource Units can be used for included and optional features, up to the Maximum RU Capacity limit.
Feature Resource Unit (RU) Requirements Table
Feature
Maximum Allowed on P-Series
(subject to RU cap. limit)
RU Required for each
Local OpCenter
1
2
Advanced Video Analytics Channels (Facial
Surveillance, LPR, etc.)
16
1 per analog camera or 704x576 region in an IP camera
32
0.5
Up to 2 MP
8 (10 on NVR)
2
Above 2 MP
5 (6 on NVR)
3
16 (20 on NVR)
1
Up to 2 MP
4 (5 on NVR)
4
Above 2 MP
2 (3 on NVR)
6
IP Cameras (MJPEG* or dual-stream**)
Up to 704x576
IP Cameras (MPEG4 or H.264 only)
Up to 704x576
Multiple streams from a camera should be treated as separate cameras, and require RUs that correspond with their resolution. For
example, 3 VGA virtual regions from the same 2MP camera are considered 3 separate IP cameras.
Cameras that contain multiple physical cameras (the Arecont™ 8180 or 8360, for example) should be treated as multiple cameras.
*
* *For MJPEG-only cameras, subject to maximum limit of 50 MP/s.
**Dual-stream cameras (most cameras are) can supply both MJPEG for motion detection
and analysis as well as a MPEG4 or H.264 stream for storage. This is preferred.
Upgrade and Configuration Guide
3VR SmartRecorder, ServerClass 100
The basic unit of system load is the Resource Unit (RU). Each 3VR SmartRecorder model has a different maximum RU capacity. For
the SmartRecorder, ServerClass 100, the following RU and Channel Capacity limits are enforced:
ServerClass 100 Resource Unit (RU) and Camera Capacity Table
ServerClass 100
SmartSearch NVR models
(SRSC-N100- XXXX)
Maximum RU Capacity
32-channel hybrid models
(SRSC–32100-XXXX)
24
Maximum Camera/Channel Capacity (Analog
and IP up to 704x576; NVR is IP capacity only)
48
48 (32 analog max)
Resource Units can be used for included and optional features, up to the Maximum RU Capacity limit.
Feature Resource Unit (RU) Requirements Table
Feature
Maximum Allowed on ServerClass
100 (subject to RU cap. limit)
RU Required for each
Local OpCenter
1
2
Advanced Video Analytics Channels (Facial
Surveillance, LPR, etc.)
20
1 per analog camera or 704x576 region in an
IP camera
Up to 704x576
48
0.5
Up to 2 MP
12
2
Above 2 MP
8
3
Up to 704x576
24
1
Up to 2 MP
6
4
Above 2 MP
4
6
IP Cameras (MJPEG* or dual-stream**)
IP Cameras (MPEG4 or H.264 only)
Multiple streams from a camera should be treated as separate cameras, and require RUs that correspond with their resolution. For
example, 3 VGA virtual regions from the same 2MP camera are considered 3 separate IP cameras.
Cameras that contain multiple physical cameras (the Arecont™ 8180 or 8360, for example) should be treated as multiple cameras.
***For MJPEG-only cameras, subject to maximum limit of 50 MP/s.
**Dual-stream cameras (most cameras are) can supply both MJPEG for motion detection