Warning! Hazardous voltage! Installation by person with electrotechnical expertise only. Avertissement! Tension électrique dangereuse! Installation uniquement par des personnes qualifiées en électrotechnique. ¡Advertencia! ¡Tensión peligrosa! La instalación deberá ser realizada únicamente por electricistas especializados. Avvertenza! Tensione pericolosa! Far installare solo da un elettricista specializzato. Varning! Farlig spänning! Installation får endast utföras av en elektriker. Oсторожно! Опасное напряжение! Монтаж должен выполняться только специалистом-электриком. 警告!危险电压!仅可由电气专业人员安装。 CM-PBE, CM-PFE, CM-PFE.2, CM-PVE Operating and installation instructions Three-phase monitoring relays, CM range 2CDC 253 005 F0015 Note: All statements serve exclusively to describe the product and have not to be understood as assured characteristics with legal force. Further information and data is obtainable from the catalogues and data sheets of this product, from the local ABB sales organisations as well as on the ABB homepage www.abb.com. Subject to change without prior notice. 2CDC 253 004 F0015 0.6...0.8 Nm 5.31...7.08 lb.in Ø 4.5 mm / 0.177 in / PZ 1 10 mm 0.39 in 10 mm 0.39 in 10 mm 0.39 in 2 x 0.75...1.5 mm² 2 x 18...16 AWG 2 x 1.0...1.5 mm² 2 x 18...16 AWG 2 x 0.75...1.5 mm² 2 x 18...16 AWG 2CDC 252 048 F0009 CM/CT-E range 2CDC 252 048 F0009 Printed in Germany - Doc.no. 1SVC 550 510 M0001 A (12/15) Warnung! Gefährliche Spannung! Installation nur durch elektro technische Fachkraft. ABB STOTZ-KONTAKT GmbH, Eppelheimer Straße 82, 69123 Heidelberg / Germany www.abb.com/lowvoltage Technical data: Ta:-20 ... +60 °C (-4 ... +140 °F) IP 20 Pollution degree 3 CM-PFE.2: If both, ambient temperature > 50 °C and rated operational currents > 2 A, lateral spacing to other units has to be min. 10 mm (0.394 in). L1, L2, L3, N Measuring value L1, L2, L3, N with neutral L1, L2, N L1, L2, L3, N L3 t L1, L2, L3, N L1 t s L2, L3, N N <t v L1, L2 L1, L2, L3, N L3 t s <t s v 13-14 2CDC 252 045 F0203 CM-PBE R: yellow LED L1, L2, L3 Measuring value L1, L2, L3 without neutral L1, L2 L1, L2, L3 L3 t L1, L2, L3 L1, L2 L3 t s L1, L2, L3 L1, L2 L3 <t v t s <t s v 13-14 R: yellow LED 2CDC 252 046 F0203 ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms L1, L2, L3 Measuring value L1, L2, L3 L1, L3, L2 t t s L1, L2, L3 t v L1, L2 L1, L2, L3 L3 t s v t s 11-14 11-12 2CDC 252 061 F0208 CM-PFE, CM-PFE.2 R: yellow LED ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms L1, L2, L3, N Umax Umax - 5 % Measuring value with neutral Umin + 5 % Umin ts tv <ts ts <tv tv ts ts <tv tv ts 2CDC 252 047 F0203 CM-PVE 13-14 R: yellow LED L1, L2, L3 Umax Umax - 5 % Measuring value Umin + 5 % Umin without neutral ts tv <ts 13-14 R: yellow LED ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms 2CDC 252 048 F0203 ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms
© Copyright 2026 Paperzz