Power cables AXQJ-RMF 7/12 kV 10 kV halogen-free power cable Application fields Material declaration Halogen-free and fire classified cable. No emittance of corrosive gases, low smoke density in case of fire. Primary developed for installation indoors, tunnels etc. The cable can also with advantage be installed outdoors and in ground. Ploughing down is not recommended. AXQJ-F, –RMF Alternative designation Impulse voltage 75 kV Bending radius At fixed mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D At pulling in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12D At ploughing down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8D SE-N10XC7Z1-AR Standards Design SS 424 14 16 CENELEC HD 620 Part 6 Section M CENELEC HD 604 Halogen-free Materials IEC 60754-1, –2 Corrosive Gases IEC 61034 Smoke Density Conductor . . . . . . . . . . . stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductor screen . . . . . extruded Insulation . . . . . . . . . . . . XLPE,min.thickness=2,96mm Insulation screen . . . . . extruded bonded Taping . . . . . . . . . . . . . . . conductive tape Concentric conductor. . annealed copper wires Sheath . . . . . . . . . . . . . . halogen-free compound, black Fire propagation class F4B acc. to SS 424 14 75 and IEC 60332-3 cat B and SS-EN 50266-2-3 Temperature range In continuous operation max. conductor temp . . . . .90˚C Lowest cable temperature under installation . . . . . –20˚C and below 0˚C special precaution shall be taken. Number of cores x cross section of conductor Diameter over insulation Overall diameter (approx.) Weight (approx.) Standard delivery length Standard drum size Article number Electrical data at +20˚C Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current Electrical data Current rating at core temp. 65˚C in ground Current rating at core temp. 65˚C in air Current rating at core temp. 90˚C in air Max. short circuit current on the conductor during 1 s at initial temp. 70˚C Max. short circuit current on the conductor during 1 s at initial temp. 90˚C Max. impulse current Marking E.g. AXQJ-RMF 7/12 kV 3x150/25 LT F4B DRAKA SE “Date”, meter marked. mm2 mm mm kg/100 m m 3x50/16 16,0 43,6 153,2 500 K18 0071210 3x95/16 19,3 51,1 219,4 500 K20 0071220 3x150/25 22,2 58,0 297,3 500 K22 0071230 3x240/25 26,1 66,8 405,3 500 K24 0071240 Ω/km Ω/km mH/km Ω/km µF/km A/km 0,641 1,2 0,34 0,11 0,23 0,4 0,320 1,2 0,31 0,10 0,30 0,6 0,206 0,8 0,29 0,09 0,35 0,7 0,125 0,8 0,27 0,09 0,43 0,8 A A A 145 130 160 205 190 230 260 250 305 340 330 400 kA 5,1 9,7 15,3 24,4 kA 4,7 9,0 14,2 22,7 kA 55 65 70 70 Nominal values unless otherwise specified. AS Draka Keila Cables www.draka.ee Member of Prysmian Group www.prysmian.com Paldiski Road 31 76606 Keila, Estonia Phone +372 674 7466 Fax +372 674 7468 The technical specifications may change any time without prior notice.
© Copyright 2026 Paperzz