Operating and installation instructions WAREMA Mobile System WMS Wind sensor Keep for future use Valid from 01 February 2017 General information CCAUTIO Never activate buttons on your transmitter arbitrarily without visual contact to the sun shading product. Children may not play with this product - remote controls or transmitters may not get into the hands of children! Carry out the following steps in the sequence given to ensure problem-free operation: Please read these instructions carefully Execute the necessary installation work with the system in a de-energised state. Take the wind sensor into service as described below Fig. 1 WMS Wind sensor The WAREMA Mobile System (WMS) Wind sensor is designed for use with terrace awnings. The wind sensor is mounted on the drop profile and evaluates the movements of the awning. In high winds, the sensor sends a signal to the WMS Plug receiver, which then retracts the awning. In awnings with a valance roller blind, the valance is retracted first, and then the awning. The WMS Wind sensor is combined with a WMS Plug receiver at the factory. The wind sensor is not visible in the WMS radio network and communicates directly with the plug receiver. Various packages are available at the factory that fit the projection of the awning (length when extended). Prefabricated packages with the necessary number of wind sensors and plug receivers are also available for awnings with one or two valance roller blinds. The awning can also be controlled by additional sensors (e.g. photo, precipitation) in parallel to the wind sensor. Intended use The WMS Wind sensor was developed to control sun shading systems. The approval of the manufacturer must be obtained for uses outside of the purposes listed in these instructions. Check that the system is functioning correctly Installation The WMS Wind sensor is mounted on the drop profile of the terrace awning. The wind sensor may not be exposed to direct sunlight. When using multiple WMS Wind sensors, the distance between the sensors must be at least 0.3 m! If the awning is delivered with the WMS, the mounting plate for the wind sensor is preinstalled. The "Mounting information" section contains the necessary figures and instructions for your awning type. Have the small parts needed to attach the mounting plate ready. De-energise the entire sun shading control system. Screw the mounting plate of the wind sensor onto the drop profile of the awning as shown in the figure. Note also the additional mounting information in the table. CCAUTIO If your awning has the minimum unit width of the corresponding type (see the table), an additional arm stop is necessary (not included). First mount the arm stop and then the wind sensor to prevent the articulated arms from pushing off the wind sensor when the awning is closed. Safety instructions WWARNIN Work on the electrical and mechanical parts of the overall system must only be performed when the system has been deenergised. The system must be sufficiently secured against unauthorised and inadvertent reactivation. The wind sensor may cause the awning to move unexpectedly if it is jolted – danger of an accident! 890376_e•en•2017-02-01 We reserve the right to carry out improvements 1 Commissioning Operating elements and displays Insert the supplied batteries into the battery compartment as described in the "Maintenance" section. Click the wind sensor into the mounting plate. Switch on the power supply of the sun shading control system. Check the function of the wind sensor by shaking the drop profile with the awning extended. The unit is now ready for operation. NNOTICE A receiver and the connected sun shading system cannot be operated until a transmitter has been learned in successfully! The learning process is described in the receiver operating instructions. In addition, you can obtain the "WMS in practice" brochure with numerous practical examples of learning, making settings and WMS networks; the brochure is available free of charge from your specialist dealer. Alternatively, the brochure can be downloaded at: http://www.warema.de Products Controls WAREMA Mobile System. The WAREMA Mobile System also enables a wide range of special functions. Should you require further information, your specialist dealer will be pleased to give you the WMS application brochure. Fig. 2 Pos. Fig. A Insert the supplied batteries into the battery compartment. Proceed as described in the WMS Toolkit software manual. After programming is completed, snap the wind sensor into the mounting plate. Function Red LED Indicates weak batteries, a wind alarm or a malfunction Learn button Causes the associated receiver to wave B C Green LED Indicates that the batteries are sufficiently charged Battery button Displays the battery charge status or activates the "Replace battery" mode D Back Commissioning with the WMS Toolkit If the WMS Wind sensor has not been programmed on the WMS receiver at the factory (retrofitting, spare part, etc.), the commissioning must be carried out using the free WMS Toolkit software. A WMS Stick (art. no. 1002 775) is absolutely required for this. Operating panel of the WMS Wind sensor Fig. 3 Pos. K + AAA – – AAA + Back of the WMS Wind sensor Fig. Function Batteries The WMS Wind sensor requires two batteries of type AAA (IEC LR03, "Micro") Check the function of the WMS wind sensor by shaking the front rail when the awning is extended. The unit is now ready for operation. 2 We reserve the right to carry out improvements 890376_e•en•2017-02-01 Operation Opening the "Replace battery" mode Checking the battery charge status Occasionally check the battery charge status of the wind sensor. If the wind sensor can no longer respond, the awning is automatically retracted or is stopped after several seconds if it is being extended to protect against wind damage. Button/ display Action/result Switch off the wind monitor as follows, for example to replace the batteries. Button/ display Press the battery button for at least 5 seconds. The LEDs indicate the status of the wind sensor: GREEN flashes:Battery OK, communication with the plug receiver is OK GREEN flashes, RED lights up:Battery OK; communication with the plug receiver is faulty RED flashes:The battery charge status is critical No display:The battery voltage is already below the minimum level NNOTICE battery button for approx. 5 seconds until Press the the red LED lights up continuously and then take the wind sensor off the mounting plate. To replace the batteries (type AAA, IEC LR03, "Micro"), remove the four screws on back of the housing. Open the battery compartment (Fig. 3) and insert the new batteries. Ensure the correct polarity: The plus (+) and minus (-) poles of the batteries must agree with the marks in the battery compartment. The wind sensor goes into sleep mode after 3 minutes. The "Replace battery" mode remains active. It continues to remain active even after the batteries are replaced. Press any button to end the "Replace battery" mode. NNOTICE Replacing the batteries Check the battery charge status at least once a year. Replace the batteries if the red LED lights up after pressing the battery button. If the batteries are depleted, the awning is automatically retracted or is stopped after several seconds if it is being extended to protect against wind damage. The red LED lights up. The wind monitor is deactivated. The wind sensor can be removed without initiating a wind alarm. Briefly press the battery button. Action/result If the "Replace battery" mode cannot be activated before replacing the batteries (e.g. the batteries are depleted), you should activate the mode briefly after inserting the new batteries. In this way, the wind sensor can detect that you replaced the batteries, enabling it to correctly determine the battery charge status again. Identifying the plug receiver Button/ display Action/result Press the learn button for at least 3 seconds. The red LED lights up for half a second. The plug receiver belonging to the wind sensor (i.e. the connected awning) waves. Only use new batteries of the same type and always replace both batteries. Use high quality batteries inexpensive batteries can leak and damage the device. If the device is not used for a longer period, please remove the batteries. Do not use rechargeable batteries. Clip the wind sensor back onto the mounting plate and press any button on the wind sensor to end the "Replace battery" mode. 890376_e•en•2017-02-01 We reserve the right to carry out improvements 3 Maintenance and cleaning Storage If you will not be using the awning for an extended period (e.g. over the winter, during which negative temperatures will shorten the battery life), take the WMS Wind sensor off the mounting plate. Store the wind sensor in an enclosed area and remove the batteries during this time. Technical data WAREMA Mobile System WMS Wind sensor Min. Typ. Max. Unit Supply Battery type 2 x AAA (IEC LR03, "Micro") Supply voltage 2.4 3.0 3.2 V DC RF transmitter Cleaning Clean the enclosure with a soft, damp cloth. Do not use detergents or cleaners, abrasive substances or steam cleaners. Liability Failure to comply with the product information in these instructions and use of the unit in a manner that contravenes its intended use and purpose may result in the manufacture refusing to honour warranty claims for product damage. In this case, liability for consequential harm to persons or damage to property will also be excluded. Follow the instructions in the operating instructions of your sun shading system. Liability is also excluded for damage to the sun shading system resulting from operation under icy conditions. Disposal After use, the device and the batteries must be disposed of according to legal regulations or brought to your local recycling centre. Transmission frequency 2.40 2.48 GHz Transmission power 0 dBm Reception sensitivity -95 dBm Range (environment without interference) 30 m Enclosure Dimensions (L×W×H in mm) 71 × 40 × 27 Degree of protection IP65 Safety class III Automatic operation Type 1 Software class A Location of use Clean ambient conditions Conformity Viewable under www.warema.de This device complies with the EMC directives for use in residential and commercial areas. Ambient conditions Operating temperature -20 Storage temperature -25 Rel. humidity (non-condensing) 10 20 40 60 °C 70 °C 85 %RH Article numbers WMS Wind sensor 1002 772 WAREMA Renkhoff SE Hans-Wilhelm-Renkhoff-Strasse 2 D-97828 Marktheidenfeld Germany 4 We reserve the right to carry out improvements 890376_e•en•2017-02-01
© Copyright 2025 Paperzz