See next page for troubleshooting instructions and reset procedure. Apollo Instructions: !! The reset procedure has changed: RESET PROCEDURE: Press and hold the DOWN button on the Switch (P7) until the desk reaches Its lowest height. Release the DOWN button. Press and hold the DOWN button again until the LED Display reads “RST” or about 10 seconds on non-LED handset models. Release the DOWN Button. Press and hold the DOWN button again until the desk lowers a little bit more, slightly rises And stops. Release the DOWN button. Your desk is now ready to use. TROUBLE-SHOOTING Assuming the desk is plugged into a working outlet and all connections (such as power cord) are securely in place. If the handset is dark - replace the handset. If the replaced handset is still dark - replace the control box. If the handset say "R5T" (reset), Er1 – Er12: Most of the time, after performing a reset procedure, the desk will resume normal operation or the display changes to/ remains on an ER message (error message). If the handset still says "R5T" you can replace the control box to see if that fixes the issue. If you have an ER message, check if any of the cables are loose, do a reset procedure to see if the error message is cleared. If any ER message remains. 1) Make note of the error message - Er1 –Er12. 2) Switch the cables at the control box (only), do a reset, see if the error message changes. 3) If the error message does not change, replace the control box. 3) If the error message changes then it is most likely either the cable or lifting column coming from a particular port on the control box (see attached). 4) Now if you switch the cables completely (move the left cable to the right side, move the right cable to the left side), do a reset, does the error message change? 5) If yes, the cable is bad - replace the cable (see attached to determine port locations on the control box). 6) if not, the lifting column motor or hall sensor circuit board is bad - replace the lifting column (see attached to determine the port locations on the control box) !Control Box Error Messages: ! Error Code Error summary E01 M1 overcurrent protection Handset shows E01 All Columns Stop Working, Press any key shows RST System need reset E02 M2 overcurrent protection Handset shows E02,All Columns Stop Working, Press any key shows RST System need reset E03 M3 overcurrent protection Handset shows E03,All Columns Stop Working, Press any key shows RST System need reset E04 M4 overcurrent protection Handset shows E04,All Columns Stop Working, Press any key shows RST System need reset E05 M5 overcurrent protection Handset shows E05,All Columns Stop Working, Press any key shows RST System need reset E06 M6 overcurrent protection Handset shows E06,All Columns Stop Working, Press any key shows RST System need reset Description E07 M1 Hall Error Handset shows E07,All Columns Stop Working, Press any key shows RST System need reset E08 M2 Hall Error Handset shows E08,All Columns Stop Working Press any key shows RST System need reset E09 M3 Hall Error Handset shows E09,All Columns Stop Working Press any key shows RST System need reset E10 M4 Hall Error Handset shows E10,All Columns Stop Working, Press any key shows RST System need reset E11 M5 Hall Error Handset shows E11,All Columns Stop Working, Press any key shows RST System need reset E12 M6 Hall Error Handset shows E12,All Columns Stop Working, Press any key shows RST System need reset E13 communication interrupt between controller A and B Handset shows E13,All Columns Stop Working, Press any key shows RST System need reset H01 over heat protection/Duty cycle protection Handset shows H01,All Columns Stop Working, Press any key useless, Handset shows current height after rest Remark: 1、 6 lift columns synchro working by 2 control boxes, the main control box is "A", and the other one is "B" 2、M1M2M3 controlled by Single control box or "A" control box, M4M5M6 controlled by control box "B" 3、 Overcurrent protection trigger condition:(1)over loaded when columns lifting up (2)colums still running when reach highest/lowest position (3)mechanical fault ,electric fault 4、 Hall Error trigger condition:(1)+5V/GND/H1/H2/ wire fault (2)motor core fault , no signal or few signal output 5、Communication interrupt between A and B trigger condition:(1)controller B or controller A_SCI2 fault(2) connection between controller A and B fault 6、Over heat trigger condition Too high temperature for Heating elements 7、Duty cycle trigger condition continuously working more than 4 minutes, need rest 16 minutes !
© Copyright 2025 Paperzz