INSTRUCTIONS ORIFICE METERS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components, by unqualified personnel, can result in fire, explosion, severe personal injury, or even death. TABLE OF CONTENTS Subject A. B. C. D. E. F. Page General Information..............................................................................................…… 2 Receiving and Inspection.....................................................................................…… 2 Installation..............................................................................................................….. 3 Manometer Adjustment...........................................................................................…. 3 Operation................................................................................................................…. 3 Maintenance............................................................................................................…. 4 Attached: Hauck Orifice Meter Capacity Charts These instructions are intended to serve as guidelines covering the installation, operation, and maintenance of Hauck equipment. While every attempt has been made to ensure completeness, unforeseen or unspecified applications, details, and variations may preclude covering every possible contingency. WARNING: TO PREVENT THE POSSIBILITY OF SERIOUS BODILY INJURY, DO NOT USE OR OPERATE ANY EQUIPMENT OR COMPONENT WITH ANY PARTS REMOVED OR ANY PARTS NOT APPROVED BY THE MANUFACTURER. Should further information be required or desired or should particular problems arise which are not covered sufficiently for the purchaser's purpose, contact Hauck Mfg. Co. HAUCK MANUFACTURING CO., 100 North Harris Street Cleona, PA 17042 717-272-3051 4/14 www.hauckburner.com Fax: 717-273-9882 OMG-9 Page 2 OMG-9 A. GENERAL INFORMATION The Hauck Orifice Metering System is a family of assemblies of threaded or welded design used for measuring the flow of either combustion air or any industrial gas. These meters may be used in the main gas and air lines or in the gas and air lines of individual burners. The former configuration allows the monitoring of total flow while the latter method allows precise setting of each burner. B. RECEIVING AND INSPECTION Upon receipt, check each item on the bill of lading/and or invoice to determine that all equipment has been received. A careful examination of all parts should be made to ascertain if there has been any damage in shipment. IMPORTANT If the installation is delayed and the equipment is stored outside, provide adequate protection as dictated by climate and period of exposure. Special care should be given to all motors and bearings, if applicable, to protect them from rain or excessive moisture. C. INSTALLATION 1. Install the orifice meter in any position in the appropriate line. Most orifice meters are available in either of two configurations: one designed specifically for a welded connection, the other for a threaded female connection. The location chosen for installation should permit easy access to both pressure cocks and allow sufficient space to remove the orifice plate, if required. When used in the gas and air lines of individual burners, mount the orifice meter between a flow control valve and the burner. NOTE For maximum accuracy provide 10 pipe diameters of straight piping without fittings immediately preceding the orifice meter and 5 pipe diameters downstream of the orifice. 2. Insert and loosely tighten the three (3) connecting bolts not required to hold the orifice plate in position. 3. Insert the orifice plate and secure it in place by insertion of the fourth connecting bolt. Page 3 OMG-9 4. Firmly tighten all bolts. 5. Insert a threaded plug in the unused cock openings. D. MANOMETER ADJUSTMENT 1. Place the manometer on a rigid support. 2. Insert the proper amount of fluid into the manometer and adjust the fluid height until a 0.0" manometer reading is obtained. 3. Connect the orifice meter pressure cocks to the manometer, using EQUAL lengths of vinyl tubing, such as Tygon, or equivalent. E. OPERATION The orifice metering system is designed so that the specific water column (wc) differential observed on the manometer corresponds to a specific flow rate through the orifice (for the specific plate being used). 1. Fully open the orifice meter pressure cocks. Page 4 OMG-9 NOTE To reduce the risk of "blowing" the manometer (forcing the fluid out of the manometer into the tubing) tubing clips or valves can be located in the vinyl tubing lines near the manometer. The clips or valves are first closed and then the orifice meter cocks are opened. The clips or valves are then opened. Locating the shutoff near the manometer minimizes the gas volume being compressed when the opposite leg of the manometer is opened to system pressure. Reducing this volume limits movement of fluid in the manometer. 2. Read the water column differential in inches and tenths of an inch. If the reading differs from the desired reading, adjust the flow control valve until the manometer coincides with the desired reading. 3. Fully close the orifice meter pressure cocks (and tubing clips if applicable). 4. Disconnect the connecting tubing, if desired. F. MAINTENANCE The design of the orifice plate and brackets requires no service or maintenance. If it ever becomes necessary to change the orifice plate: 1. Loosen all four (4) connecting bolts. 2. Completely remove the plate positioning bolt. 3. Remove the old plate and insert the new one. 4. Securely tighten all connecting bolts. Periodically check the quantity of fluid in the manometer and refill as required. Page 5 OMG-9 OMG SERIES ORIFICE METERS AIR & NATURAL GAS FLOW CAPACITY (SCFH) 100 – 200 Series Threaded / Weld-In 3/8" Through 1 ½" Pipe Size Pipe Size OMG Model Number 3/8" 103 1/2" 105 3/4" 107 1" 110 1 ¼" 112 1 ½" 115 Orifice Bore Size 0.197 0.232 0.266 0.307 0.350 0.232 0.266 0.317 0.368 0.423 0.273 0.324 0.379 0.437 0.508 0.585 0.324 0.384 0.452 0.523 0.613 0.715 0.456 0.533 0.630 0.735 0.850 0.986 0.533 0.635 0.744 0.867 1.005 1.156 Air 0.5" 1" 3" w.c.P w.c.P w.c.P 33 57 24 33 46 80 44 62 107 61 85 147 84 118 203 45 78 32 42 60 103 61 86 149 85 120 206 118 166 286 62 107 44 62 87 151 86 121 208 116 163 282 162 228 394 221 322 555 86 149 61 86 122 210 120 170 293 163 230 398 231 326 562 331 467 806 120 170 294 165 233 403 233 330 570 324 457 790 447 632 1092 641 905 1564 164 232 400 234 331 572 325 459 794 450 636 1100 626 885 1530 881 1245 2151 5" w.c.P 73 103 137 189 261 100 133 191 265 368 137 194 268 363 507 714 192 270 378 513 724 1039 379 520 734 1018 1407 2015 516 737 1023 1417 1972 2771 Natural Gas 3" 0.5" 1" w.c.P w.c.P w.c.P 30 43 73 42 60 103 57 80 137 78 110 189 108 152 262 41 58 100 55 77 133 79 111 192 109 154 266 152 214 369 57 80 137 80 113 194 110 156 269 149 211 363 208 294 508 294 415 716 79 111 192 111 157 271 155 219 378 211 297 513 297 420 725 427 602 1040 155 219 379 213 301 520 301 425 735 418 590 1020 577 815 1409 827 1168 2018 212 299 517 302 427 738 419 593 1024 581 821 1419 808 1142 1974 1137 1607 2776 5" w.c.P 94 132 177 244 336 129 171 247 342 475 177 250 346 468 654 921 247 349 487 661 935 1340 488 671 947 1314 1816 2600 666 951 1320 1829 2544 3576 Notes: 1. 2. 3. 4. 5. Orifice Bore Size Equals The Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Equals Schedule 40 Pipe. Capacity Based On 60F @ 1 psig Upstream Pressure. Natural Gas Specific Gravity At 0.60; Air Specific Gravity At 1.0. 1__ Model Number Designates NPT Threaded Connection. 2__ Model Number Designates Weld-In Connection. All Flow Rates At Standard Barometric Pressure: 29.92" Hg (Sea Level). Design Capacity Is Based On 3" W.C.P. Continued Page 6 OMG-9 OMG SERIES ORIFICE METERS AIR & NATURAL GAS FLOW CAPACITY (SCFH) 100 – 200 Series Threaded / Weld-In 2" Through 6" Pipe Size Pipe Size OMG Model Number 2" 120 2 ½" 125 3" 130/230 4" 240 6" 260 Orifice Bore Size 0.640 0.754 0.875 1.034 1.203 1.375 0.754 0.890 1.048 1.236 1.423 1.625 0.894 1.056 1.252 1.452 1.688 1.963 1.261 1.470 1.722 2.029 2.345 2.691 1.735 2.067 2.437 2.879 3.314 3.850 4.388 Air 0.5" w.c. P 238 334 455 650 911 1250 330 464 651 926 1266 1730 462 649 923 1262 1753 2483 919 1258 1748 2479 3418 4731 1729 2470 3468 4924 6685 9423 13055 1" w.c. P 335 470 640 914 1278 1753 465 652 916 1302 1778 2428 651 914 1300 1776 2466 3489 1295 1773 2462 3491 4810 6655 2439 3484 4890 6941 9420 13272 18381 3" w.c.P 5" w.c.P 0.5" w.c.P 577 808 1100 1568 2192 3003 800 1123 1576 2237 3053 4164 1122 1575 2237 3056 4238 5993 2234 3056 4242 6009 8275 11440 4211 6011 8434 11965 16231 22856 31638 743 1039 1415 2016 2817 3858 1030 1445 2027 2877 3925 5353 1444 2027 2879 3932 5452 7706 2877 3935 5461 7734 10648 14716 5425 7743 10863 15408 20897 29419 40712 307 430 586 836 1170 1605 425 597 838 1191 1628 2223 595 836 1188 1625 2256 3193 1184 1621 2251 3192 4400 6088 2229 3184 4469 6344 8611 12135 16809 Natural Gas 3" 1" w.c.P w.c.P 432 605 824 1175 1644 2253 599 840 1180 1676 2288 3123 839 1178 1674 2287 3174 4491 1670 2285 3173 4497 6195 8568 3146 4493 6305 8947 12140 17101 23679 744 1041 1417 2019 2822 3865 1031 1447 2030 2881 3932 5362 1446 2030 2884 2938 5460 7719 2881 3941 5468 7746 10665 14741 5432 7754 10878 15429 20928 29466 40781 Notes: 6. 7. 8. 9. 10. Orifice Bore Size Equals The Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Equals Schedule 40 Pipe. Capacity Based On 60F @ 1 psig Upstream Pressure. Natural Gas Specific Gravity At 0.60; Air Specific Gravity At 1.0. 1__ Model Number Designates NPT Threaded Connection. 2__ Model Number Designates Weld-In Connection. All Flow Rates At Standard Barometric Pressure: 29.92" Hg (Sea Level). Design Capacity Is Based On 3" W.C.P. 5" w.c.P 958 1339 1823 2597 3629 4967 1328 1863 2613 3707 5056 6894 1863 2614 3712 5068 7026 9929 3710 5075 7041 9971 13725 18966 6998 9988 14011 19870 26946 37931 52484
© Copyright 2026 Paperzz