APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H Horizontal packaged air conditioners 10 28 kW FLATAIR AGU-MSL60-1505-E lennoxemeia.com INDEX FLATAIRTM APPLICATION GUIDE Ref : FLATAIR AGU-MSL60-1505-E CONTENTS PAGE 1 - General description 2 2 - Denomination 4 3 - Range of products /technical features 5 4 - Operation limits 7 5 - Fan performances 8 6 - Sound level 9 7 - Capacities 10 9 - Electrical data 17 10 - Dimensions 18 11 - Installation 25 12 - Options 28 All the technical and technological information contained in this manual, including any drawing and technical descriptions provided by us, remain the property of Lennox and must not be utilised (except in operation of this product), reproduced, issued to or made available to third parties without the prior written agreement of Lennox. Application Guide • FLATAIR-AGU-MSL60-1505-E •1• 1 - GENERAL DESCRIPTION 1.1- GENERAL DESCRIPTION The horizontal air conditioning units, range Flatair, cooling only or heat pump are air condensed units designed for small shopping center and housing. They can be supplied either compact or on split system. Due to their small dimensions they are designed for false ceiling and can be placed in air conducts both indoor and outdoor sections. A wide range of optionals, completed-factory assembled are also available. FURNITURE EXCHANGER Painted in galvanized metal furniture, high resistant to corrosion. The units are provided with metal profiles, capable of withstanding the unit and able as well of installing the unit hung from the ceiling or mounted on the floor. Panels are easily inter exchangeable, giving several air suction and return alternatives. An insulation with a protection of mesh is used in indoor section with a classification of M1 and F1, certifying that the material is auto-extinguishable and avoiding the fumes inside the room to be aconditionned. Auto extinguishable insulation M1 is used in outdoor units. Made-up with copper pipes and aluminium fings, designed to get a high heat transfer. COMPRESSORS All units are provided with scroll compressor, cooling by a suction gas with thermic protection inside the engine, so no other additional protection is required. It is mounted on anti-vibration devices both external and internal. All compresors are R410A In heat pump units the compressors are provided with a crankcase heater to heat the oil in the compressor so that a suitable lubrication can take place. AIR FILTER Washable air filter; auto extinguishable material with M1 classification, high efficiency filtrate with G2 classification. It can be removed through the upper part and from both sides. Their dimensions and design of the refrigenrant circuit have been specially worked to obtain the maximum performance of the exchanger increasing the power of the unit and reducing the consumption. COOLING CIRCUIT Carried out with welded deshydratable copper pipes with pressure intakes with schraeder valves in the suction and liquid lines both indoors and outdoor units. In unit 20-25-30 the pressure intakes in the outdoor section are approachable from the outer part of the unit. The unit is equipped with both high-low pressure switches with an automatic reset. It also has a dehydrating filter, expansion system with restrictors in units 10-12-15; expansion valves in units 20-25-30. The heat pump units are equipped as well with a suction accumulator to avoid the liquid return to the compressor, 4 way valve and no-return valve. ELECTRICAL CIRCUIT Designed according to EN 60204-1 normative hermetically sealed to avoid condensation. With circuits breakers to protecto the unit from overloading. FAN Outdoor and indoor fans are centrifugal with an assembled engine, statically balancing, with a low sound level. Those fans are assembled to the inserted panel of the units and split from upper side of the fan with insulated materials to void vibrations. Flatair units are designed for false ceiling mounting, to be installed exclusively indoor. For outdoor mounting, a shelter or roof structure has to be installed, to avoid direct water entry in the sensible parts of the unit (electrical board, joints between the indoor unit and the outdoor unit). •2• Application Guide • FLATAIR-AGU-MSL60-1505-E 1 - GENERAL DESCRIPTION 1.2- CONTROL CLIMATIC 40 VERSION CLIMATIC 60 VERSION CLIMATIC™ 60 controller intelligently improves efficiency and helps set up and service operations to guarantee long lasting performance. We have two versions of Control in Flatair units: - The basic C40 platform, wich includes one terminal in the unit and another DC40 remote - The advanced platform C60 which includes one terminal in the unit, and 3 remote terminals as in option (DC, DS, DM) OPTIMIZED OPERATION AND SETUP SAVES ENERGY CLIMATIC™ 60 is designed to provide the best energy efficiency throughout unit’s life cycle while ensuring reliable and consistent operation with user friendly interfaces. This new controller constantly monitors more machine parameters than ever to improve rooftop operation and maximize efficiency and reliability 1.3- OPTIONS Flatair units can be equipped with the following options: - Main switch - Heating electrical heater, made of blinded elements and assembled inside the unit - Kit low ambient -15 degrees - Kit low ambient 0 degrees (only for cooling units) - 3 Phase controller (only for 3 phase units) - Customer terminal DC60 (only for CLIMATIC 60 version) - Service terminal DS60 (only for CLIMATIC 60 version) - Remote duct sensor in return - Ambient remote sensor (only en CLIMATIC 40 version) - Thermostatic freecooling - Enthalpic freecooling (only in CLIMATIC 60 version) - Second return damper for kit freecooling - Different airflow configurations in return and supply - BMS communication interface (CLIMATIC 40 as standard and CLIMATIC 60 as an option) - Echelon communication interface (CLIMATIC 60) - Bacnet communication interface (CLIMATIC 60) Application Guide • FLATAIR-AGU-MSL60-1505-E •3• 2 - DENOMINATION EXAMPLE : F F M C 0 1 5 S N M 1 M M FLATAIR 400V/3/50 Revision number M Compact unit S Outdoor unit I Indoor unit C Cooling only H Heat pump X Cooling only / heat pump M R410A --- S 1 Circuit Approximate Cooling capacity in kW i •4• FMC: Cooling only unit R-410A FMH: Heat pump unit R-410A Application Guide • FLATAIR-AGU-MSL60-1505-E 3 - MAIN TECHNICAL FEATURES A BOX FCM/FCH 10 B BOX 12 15 C BOX D BOX 20 25 30 Cooling capacity * (cooling only) kW 9.7 12 15 19.5 23.5 27 Heating capacity* (heat pump) kW 10 12.5 15.5 20.5 25 27.9 DIMENSIONS Height mm 495 495 595 595 645 645 Lenght mm 1250 1250 1300 1450 1500 1500 Depth mm 1250 1250 1330 1520 1800 1800 Kg 170 174 250 268 322 338 20 25 30 NET WEIGHT OUTDOOR UNIT FSC/FSH 10 12 15 1 / Scroll Number & Type of compressor FAN Maximum airflow rate m3/h 3500 3400 4500 5650 6000 5850 Minimum airflow rate m3/h 2350 2400 3740 4095 4760 5000 Pa 100 90 120 150 160 100 kg 112 116 165 159 202 208 Height mm 495 495 595 595 645 465 Lenght mm 1250 1250 1300 1450 1500 1500 Depth mm 820 820 830 900 1025 1025 Maximum available presure (1) NET WEIGHT DIMENSIONS PIPES CONNEXIONS Liquid m3/h 3/8" 3/8" 1/2" 5/8" 5/8" 5/8" Gas m3/h 3/4" 3/4" 7/8" 7/8" 1-1/8" 1-1/8" FIC/H 2O 20 FIC/H 25 FIC/H 30 INDOOR UNIT FIX FIX 10 FIX 12 FIX 15 Number & Type of compressor 1 / Scroll FAN Maximum airflow rate m3/h 2350 2300 3575 4850 5750 5500 Minimum airflow rate m3/h 1500 1650 2410 2090 3455 3695 Pa 120 110 160 200 240 180 kg 58 58 85 109 121 131 Electrical heater kg 7 7 7 7 8 8 Free-cooling 1 damper kg 12 12 12 14 15 15 Free-cooling 2 damper kg 24 24 24 28 30 30 Height mm 495 495 595 595 645 645 Lenght mm 1250 1250 1300 1450 1500 1500 Depth mm 430 430 500 620 775 775 Maximum available presure (1) NET WEIGHT OPTIONS WIEGHT DIMENSIONS PIPES CONNEXIONS Liquid m3/h 3/8" 3/8" 1/2" 5/8" 5/8" 5/8" Gas m3/h 3/4" 3/4" 7/8" 7/8" 1-1/8" 1-1/8" (*) (*) (1) Air intake temperature in the indoor exchanger : 27ºC DB/19ºC WB Air intake temperature in the outdoor exchanger: : 35ºC DB DB WB Dry bulb temperature Wet bulb temperature With admissible minimum air flow Application Guide • FLATAIR-AGU-MSL60-1505-E •5• 3 - MAIN TECHNICAL FEATURES 3.1 DIMENSIONS Box Unit Lenght Deep Height 1250 1250 495 1300 1330 595 1450 1520 595 A 10-12 B 15 C 20 D 25-30 1500 1800 645 A 10-12 1250 430 495 B 15 1300 500 595 C 20 1450 620 595 D 25-30 1500 775 645 A 10-12 1250 820 495 B 15 1300 830 595 C 20 1450 900 595 D 25-30 1500 1025 645 Packaged Indoor unit Outdoor unit 3.2 MINIMUM, MAXIMUM AND NOMINAL AIRFLOW RATES INDOOR UNIT FIC/H FIH 10 FIH 12 FIH 15 FIH 20 FIH 25 FIH 30 AIRFLOW RATE Maximum Nominal Minimum 2350 2140 1500 2300 2040 1650 3575 3170 2410 4850 4500 3090 5750 5470 3455 5500 5060 3695 OUTDOOR UNIT FSC/H FSH 10 FSH 12 FSH 15 FSH 20 FSH 25 FSH 30 •6• AIRFLOW RATE Maximum Nominal Minimum 3500 2970 2350 3400 2890 2400 4500 4250 3740 5650 5150 4095 6000 5600 4760 5850 5400 5000 Application Guide • FLATAIR-AGU-MSL60-1505-E 3 - MAIN TECHNICAL FEATURES 3.3 WEIGHTS FLATAIR (STANDARD) Cooling only units Heat pump units MODEL 10 12 15 20 25 30 Indoor unit FIX/FIC 58 58 85 109 121 131 Outdoor unit FSC 112 116 165 159 202 208 Package (indoor+outdoor) FMC 170 174 250 268 322 338 Indoor unit FIX/FIH 58 58 85 109 121 131 Outdoor unit FSH 117 121 170 164 207 213 Package (indoor+outdoor) FMH 175 179 255 273 327 343 electrical heater 7 7 7 7 8 8 free-cooling 1 damper 12 12 12 14 15 15 free-cooling 2 damper 24 24 24 28 30 30 OPTIONS to add indoor unit 4 - OPERATION LIMITS OPERATION LIMITS FOR COOLING ONLY UNITS Indoor temperature Maximum temperatures Minimum temperatures 32ºC DB / 23ºC WB 21ºC DB / 15ºC WB Table 1 Standard unit : + 15ºC 0ºC(*) / -15ºC(**) Cooling mode Outdoor temperature (*) With option kit low temperature 0ºC (**) With option kit low temperature -15ºC DB.- Dry bulb temperature WB.- Wet bulb temperature OPERATION LIMITS FOR HEAT PUMP UNITS Indoor temperature Maximum temperatures Minimum temperatures 32ºC DB / 23ºC WB 21ºC DB / 15ºC WB Table 1 + 15ºC STANDARD UNIT 0ºC(*) / -15ºC(**) 27ºC DB 15ºC DB Sizes 12-15-20-30 : 25ºC (1) Sizes 12-25 : 23ºC -12ºC Cooling mode Outdoor temperature Indoor temperature Heat pump mode Outdoor temperature (*) Active CL40 parameter to operate at 0ºC (**) With option kit low temperature -15ºC Application Guide • FLATAIR-AGU-MSL60-1505-E (1) : Indoor temperature : 20°C DB.- Dry bulb temperature WB.- Wet bulb temperature •7• 5 - FAN PERFORMANCES Available static pressure (Pa) INDOOR UNITS 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 10 12 25 30 2350 2300 3575 4850 5750 5500 2275 2250 2240 2200 3495 4785 5730 5455 3410 4715 5705 5405 2190 2150 2140 2100 3330 4645 5670 5350 3250 4575 5630 5285 2080 2025 2040 3170 4500 5580 5220 1975 3095 4425 5530 5140 1975 1925 1925 3020 4345 5470 5060 1860 2945 4260 5405 4965 1840 1800 2875 4175 5330 4870 1775 1730 2800 4090 5250 4765 1625 1650 2735 4000 5165 4655 1500 ---- 2665 3910 5075 4640 --- --- 2600 3815 4975 4415 --- --- 2535 3720 4870 4285 --- --- 2470 3620 4755 4150 --- --- 2410 3520 4640 4005 --- --- --- 3415 4515 3855 --- --- --- 3310 4380 3695 --- --- --- 3200 4245 --- --- --- --- 3090 4100 --- --- --- --- --- 3945 --- --- --- --- --- 3790 --- --- --- --- --- 3625 --- --- --- --- --- 3455 --- Airflow rate (m3/h) OUTDOOR UNITS Available static pressure (Pa) Airflow rate (m3/h) 15 20 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 10 12 15 20 25 30 3500 3400 4500 5650 6000 5850 3410 3325 4460 5550 5920 5755 3300 3160 4410 5450 5840 5665 3190 3075 4360 5350 5760 5575 3080 2980 4310 5250 5680 5485 2970 2890 4250 5150 5600 5400 2840 2790 4190 5050 5520 5315 2700 2690 4125 4945 5445 5235 2560 2580 4055 4840 4365 5155 2410 2400 3980 47365 5290 5075 2350 --- 3905 4630 5210 5000 --- --- 3825 4525 5135 ---- --- --- 3740 4420 5060 ---- --- --- --- 4315 4985 ---- --- --- --- 4205 4910 ---- --- --- --- 4095 4835 ---- --- --- --- --- 4760 ---- With option G4 additional pressure drop 50Pa Nominal airflow rate Keep in mind reduction on air flow and static pressure services if you use mufflers or external air filter. •8• Application Guide • FLATAIR-AGU-MSL60-1505-E 6 - SOUND LEVEL OUTDOOR UNIT dB Hz Lw dB(A) 125 250 500 1000 2000 4000 8000 10 73 70 71 72.9 69.3 68.9 62.8 77 12 74 78 69 73.6 66.3 66.1 60.5 77 15 79 74 77 78.0 75.5 72.9 68.0 82 20 81 75 81 81.9 79.2 76.5 72.2 86 25 83 76 76 76.4 75.3 72.4 65.9 81 30 83 75 75 76.0 74.7 71.6 65.0 81 Size With compressor jacket, estimated reduction of 2 Dba INDOOR UNIT dB Size Hz Lw dB(A) 125 250 500 1000 2000 4000 8000 10 71 67 67 67.4 64.9 64.1 58.3 72 12 71 67 67 67.4 64.9 64.1 58.3 72 15 74 69 72 71.3 69.1 66.0 59.7 76 20 77 71 75 75.8 73.4 70.7 65.7 80 25 79 73 79 80.2 77.4 74.5 74.3 84 30 78 72 77 78.4 75.7 72.9 68.4 83 With compressor jacket, estimated reduction of 2 Dba Application Guide • FLATAIR-AGU-MSL60-1505-E •9• 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 1500 m3/h 16 19 22 2140 m3/h 16 19 22 16 2350 m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 10 19 22 20 °C 25 °C 30 °C 35°C 40 °C 45 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC 9,56 9,56 9,60 10,46 10,45 10,48 11,46 11,44 11,45 9,96 9,98 10,03 10,90 10,90 10,94 11,93 11,92 11,94 10,00 10,02 10,18 10,95 10,95 10,99 11,99 11,98 12,00 2,80 2,80 2,80 2,84 2,84 2,84 2,88 2,88 2,88 3,05 3,05 3,05 3,09 3,09 3,09 3,13 3,13 3,13 3,15 3,15 3,16 3,19 3,19 3,19 3,24 3,24 3,24 5,88 7,21 8,41 5,78 7,14 8,33 5,61 6,98 8,18 6,61 8,36 9,97 6,46 8,27 9,91 6,22 8,08 9,76 6,83 8,71 10,18 6,68 8,62 10,40 6,42 8,43 10,26 9,29 9,30 9,35 10,15 10,15 10,18 11,12 11,10 11,11 9,65 9,67 9,75 10,55 10,56 10,60 11,55 11,54 11,57 9,67 9,70 9,91 10,59 10,60 10,64 11,59 11,59 11,62 2,96 2,96 2,96 3,00 3,00 3,01 3,05 3,05 3,05 3,21 3,21 3,22 3,26 3,26 3,26 3,31 3,31 3,31 3,31 3,31 3,33 3,36 3,36 3,36 3,41 3,41 3,41 5,75 7,07 8,27 5,65 7,00 8,19 5,48 6,85 8,05 6,48 8,21 9,75 6,34 8,12 9,74 6,11 7,95 9,61 6,70 8,55 9,91 6,56 8,47 10,23 6,32 8,30 10,11 8,96 8,98 9,03 9,79 9,79 9,83 10,71 10,70 10,72 9,28 9,31 9,45 10,15 10,16 10,21 11,11 11,10 11,14 9,29 9,32 9,59 10,17 10,18 10,24 11,14 11,14 11,18 3,16 3,16 3,16 3,21 3,21 3,21 3,26 3,26 3,26 3,40 3,40 3,42 3,46 3,46 3,46 3,52 3,52 3,52 3,51 3,51 3,54 3,57 3,57 3,57 3,63 3,63 3,63 5,60 6,91 8,09 5,51 6,84 8,02 5,35 6,70 7,89 6,32 8,02 9,45 6,20 7,95 9,54 6,00 7,79 9,43 6,54 8,35 9,59 6,42 8,29 10,01 6,21 8,14 9,91 8,57 8,59 8,66 9,36 9,37 9,42 10,25 10,25 10,28 8,85 8,89 9,09 9,68 9,70 9,76 10,60 10,61 10,65 8,85 8,89 9,21 9,69 9,71 9,77 10,62 10,63 10,67 3,41 3,41 3,41 3,46 3,46 3,47 3,52 3,52 3,52 3,65 3,65 3,68 3,72 3,72 3,72 3,78 3,78 3,78 3,77 3,76 3,80 3,84 3,84 3,84 3,90 3,90 3,90 5,43 6,71 7,87 5,35 6,65 7,81 5,21 6,53 7,70 6,14 7,79 9,09 6,04 7,74 9,30 5,86 7,61 9,21 6,36 8,11 9,21 6,25 8,07 9,75 6,07 7,95 9,68 8,12 8,15 8,22 8,88 8,90 8,95 9,73 9,73 9,77 8,37 8,41 8,68 9,16 9,18 9,25 10,04 10,05 10,10 8,35 8,40 8,79 9,15 9,18 9,32 10,05 10,06 10,11 3,74 3,74 3,74 3,80 3,80 3,81 3,87 3,87 3,87 3,98 3,97 4,02 4,06 4,06 4,06 4,14 4,14 4,14 4,11 4,10 4,14 4,19 4,19 4,21 4,27 4,27 4,27 5,23 6,47 7,61 5,17 6,43 7,57 5,06 6,34 7,48 5,93 7,52 8,68 5,85 7,49 9,00 5,71 7,39 8,94 6,13 7,82 8,79 6,06 7,80 9,32 5,91 7,72 9,39 7,62 7,66 7,73 8,34 8,36 8,42 9,15 9,16 9,20 7,82 7,87 8,22 8,57 8,61 8,68 9,42 9,44 9,49 7,79 7,84 8,31 8,56 8,59 8,77 9,42 9,44 9,49 4,21 4,20 4,20 4,29 4,29 4,28 4,36 4,36 4,36 4,44 4,43 4,49 4,55 4,54 4,54 4,64 4,64 4,64 4,59 4,58 4,63 4,71 4,70 4,73 4,80 4,80 4,79 5,00 6,19 7,29 4,96 6,18 7,27 4,88 6,11 7,22 5,68 7,19 8,22 5,63 7,19 8,64 5,52 7,13 8,62 5,87 7,47 8,31 5,82 7,48 8,77 5,72 7,44 9,04 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 10 2140 m3/h 2350 m3/h 1500 m3/h Nominal airflow Maximum airflow rate Minimum airflow Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 NC Net cooling capacity (kW) : • 10 • -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 6,40 6,40 6,41 6,43 6,45 6,48 6,62 6,61 6,61 6,63 6,65 6,67 6,84 6,83 6,83 6,84 6,86 6,88 2,44 2,60 2,71 2,88 3,01 3,15 2,50 2,70 2,76 2,93 3,05 3,18 2,49 2,69 2,74 2,90 3,02 3,14 7,39 7,36 7,36 7,35 7,36 7,37 7,66 7,62 7,62 7,61 7,61 7,62 7,90 7,86 7,85 7,84 7,84 7,85 2,62 2,77 2,89 3,07 3,20 3,34 2,63 2,83 2,89 3,06 3,18 3,31 2,61 2,80 2,85 3,01 3,12 3,24 8,37 8,32 8,30 8,27 8,26 8,26 8,69 8,63 8,61 8,58 8,57 8,56 8,95 8,88 8,87 8,84 8,82 8,81 2,79 2,95 3,07 3,26 3,39 3,54 2,76 2,96 3,02 3,19 3,31 3,44 2,73 2,92 2,97 3,12 3,23 3,35 9,34 9,27 9,23 9,18 9,16 9,14 9,72 9,63 9,61 9,55 9,52 9,50 10,00 9,90 9,88 9,82 9,79 9,77 2,96 3,13 3,25 3,45 3,59 3,74 2,89 3,10 3,15 3,32 3,45 3,58 2,84 3,03 3,08 3,24 3,35 3,47 9,73 9,65 9,60 9,55 9,51 9,49 10,13 10,02 10,00 9,94 9,90 9,87 10,42 10,31 10,28 10,22 10,18 10,15 3,03 3,20 3,32 3,53 3,68 3,83 2,94 3,15 3,21 3,38 3,50 3,64 2,89 3,08 3,13 3,29 3,40 3,52 10,31 10,21 10,16 10,09 10,05 10,01 10,75 10,62 10,59 10,51 10,47 10,43 11,04 10,91 10,88 10,80 10,76 10,72 3,13 3,31 3,44 3,65 3,80 3,97 3,02 3,23 3,29 3,47 3,59 3,73 2,96 3,15 3,20 3,37 3,48 3,60 11,27 11,15 11,08 10,99 10,93 10,88 11,76 11,60 11,57 11,47 11,41 11,35 12,08 11,92 11,88 11,78 11,71 11,66 3,31 3,50 3,64 3,87 4,03 4,21 3,16 3,37 3,43 3,62 3,75 3,89 3,08 3,28 3,33 3,50 3,62 3,75 NH Net heating capacity (kW) : SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power Application Guide • FLATAIR-AGU-MSL60-1505-E 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 1650 m3/h 16 19 22 2040 m3/h 16 19 22 16 2300 m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 12 19 22 20 °C 25 °C 30 °C 35°C 40 °C 43 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC 12,12 12,13 12,14 13,22 13,22 13,24 14,41 14,41 14,42 12,48 12,49 12,51 13,59 13,61 13,63 14,80 14,82 14,84 12,60 12,61 12,64 13,73 13,74 13,77 14,95 14,97 14,99 3,88 3,88 3,88 3,94 3,94 3,94 4,03 4,03 4,03 4,08 4,08 4,09 4,15 4,15 4,15 4,25 4,25 4,26 4,23 4,24 4,24 4,31 4,31 4,31 4,42 4,42 4,42 7,28 8,79 10,21 7,16 8,65 10,06 6,97 8,44 9,82 7,76 9,55 11,26 7,59 9,39 11,10 7,34 9,14 10,84 8,05 10,02 11,92 7,86 9,85 11,76 7,59 9,59 11,51 11,76 11,77 11,79 12,81 12,82 12,84 13,95 13,96 13,98 12,08 12,10 12,12 13,15 13,17 13,19 14,32 14,33 14,36 12,17 12,20 12,23 13,26 13,28 13,31 14,44 14,46 14,49 4,13 4,13 4,13 4,20 4,20 4,20 4,30 4,30 4,30 4,33 4,33 4,33 4,40 4,40 4,41 4,52 4,52 4,52 4,48 4,48 4,49 4,57 4,57 4,57 4,69 4,69 4,70 7,10 8,60 10,03 6,97 8,47 9,88 6,79 8,27 9,65 7,58 9,36 11,06 7,41 9,20 10,91 7,18 8,97 10,67 7,88 9,82 11,70 7,69 9,66 11,56 7,43 9,42 11,32 11,30 11,31 11,33 12,30 12,32 12,34 13,41 13,42 13,44 11,58 11,60 11,63 12,61 12,63 12,66 13,74 13,76 13,78 11,65 11,68 11,71 12,70 12,72 12,76 13,83 13,86 13,89 4,45 4,45 4,45 4,52 4,52 4,52 4,64 4,64 4,64 4,64 4,64 4,65 4,73 4,73 4,74 4,86 4,86 4,87 4,80 4,80 4,81 4,90 4,90 4,91 5,05 5,05 5,06 6,89 8,37 9,79 6,77 8,25 9,65 6,60 8,06 9,44 7,37 9,12 10,79 7,21 8,97 10,66 6,99 8,76 10,44 7,66 9,57 11,41 7,49 9,43 11,29 7,25 9,21 11,08 10,74 10,75 10,78 11,70 11,72 11,75 12,76 12,78 12,80 10,99 11,01 11,05 11,98 12,00 12,03 13,06 13,08 13,11 11,04 11,07 11,10 12,04 12,07 12,10 13,13 13,16 13,20 4,88 4,88 4,88 4,96 4,96 4,96 5,09 5,09 5,10 5,07 5,07 5,07 5,17 5,17 5,18 5,33 5,33 5,34 5,23 5,23 5,24 5,35 5,36 5,36 5,53 5,53 5,54 6,64 8,09 9,48 6,53 7,99 9,36 6,38 7,82 9,19 7,11 8,81 10,45 6,98 8,69 10,34 6,79 8,51 10,16 7,39 9,24 11,03 7,25 9,13 10,94 7,05 8,95 10,78 10,08 10,10 10,13 11,01 11,03 11,06 12,02 12,04 12,07 10,30 10,33 10,37 11,24 11,27 11,31 12,28 12,31 12,34 10,32 10,36 10,40 11,28 11,31 11,35 12,33 12,36 12,40 5,50 5,50 5,50 5,59 5,59 5,60 5,75 5,75 5,76 5,68 5,68 5,69 5,81 5,81 5,82 6,00 6,01 6,01 5,87 5,87 5,87 6,02 6,02 6,03 6,24 6,24 6,25 6,35 7,75 9,09 6,26 7,67 9,01 6,14 7,54 8,87 6,81 8,44 10,01 6,70 8,35 9,94 6,54 8,21 9,81 7,07 8,84 10,59 6,96 8,77 10,52 6,80 8,63 10,40 9,64 9,67 9,70 10,54 10,56 10,60 11,53 11,55 11,58 9,84 9,87 9,91 10,76 10,79 10,83 11,77 11,80 11,84 9,85 9,88 9,93 10,78 10,81 10,86 11,80 11,84 11,88 6,03 6,03 6,03 6,13 6,13 6,14 6,31 6,31 6,32 6,21 6,21 6,22 6,36 6,36 6,36 6,58 6,58 6,59 6,41 6,41 6,41 6,59 6,59 6,60 6,85 6,85 6,86 6,15 7,51 8,82 6,08 7,45 8,76 5,98 7,35 8,65 6,59 8,18 9,71 6,51 8,12 9,67 6,38 8,01 9,57 6,85 8,56 10,26 6,77 8,52 10,21 6,63 8,41 10,13 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 12 1650 m3/h 2040 m3/h 2300 m3/h Maximum airflow rate Nominal airflow Minimum airflow Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 GC Gross cooling capacity (kW) : -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 8,31 8,40 8,46 8,57 3,31 3,58 3,78 4,12 9,51 9,56 9,60 9,68 9,73 3,57 3,85 4,06 4,40 4,66 10,69 10,71 10,73 10,77 10,80 3,83 4,12 4,33 4,69 4,96 8,41 8,51 8,53 8,62 8,69 3,23 3,57 3,66 3,96 4,19 8,50 8,58 8,61 8,68 8,74 8,80 3,26 3,59 3,68 3,98 4,20 4,44 9,65 9,70 9,72 9,78 9,82 9,87 9,77 9,81 9,82 9,87 9,90 9,94 3,47 3,80 3,90 4,20 4,42 4,67 3,48 3,80 3,89 4,18 4,40 4,63 10,88 10,89 10,89 10,91 10,94 10,96 11,03 11,02 11,02 11,03 11,05 11,07 3,69 4,04 4,13 4,44 4,66 4,91 3,69 4,01 4,10 4,39 4,61 4,84 11,85 11,84 11,84 11,85 11,86 11,88 12,09 12,05 12,04 12,03 12,03 12,04 12,26 12,21 12,20 12,18 12,17 12,17 4,10 4,40 4,62 4,99 5,27 5,58 3,92 4,27 4,37 4,68 4,92 5,17 3,89 4,22 4,31 4,61 4,82 5,06 12,31 12,29 12,28 12,27 12,28 12,28 12,56 12,51 12,50 12,48 12,47 12,47 12,75 12,68 12,67 12,64 12,62 12,61 4,21 4,51 4,74 5,12 5,41 5,72 4,01 4,37 4,46 4,78 5,02 5,28 3,97 4,30 4,40 4,69 4,91 5,15 13,00 12,96 12,93 12,91 12,90 12,89 13,28 13,20 13,18 13,14 13,12 13,10 13,48 13,39 13,37 13,31 13,29 13,26 4,37 4,68 4,92 5,32 5,61 5,95 4,15 4,51 4,61 4,94 5,18 5,45 4,10 4,43 4,53 4,83 5,05 5,30 14,13 14,05 14,01 13,95 13,92 13,89 14,45 14,33 14,30 14,23 14,18 14,14 14,69 14,55 14,52 14,43 14,38 14,34 4,65 4,99 5,24 5,67 5,99 6,35 4,39 4,77 4,87 5,22 5,47 5,76 4,31 4,66 4,75 5,07 5,30 5,56 NH Net heating capacity (kW) : Application Guide • FLATAIR-AGU-MSL60-1505-E SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power • 11 • 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 2410 m3/h 16 19 22 3170 m3/h 16 19 22 16 3575 m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 15 19 22 20 °C 25 °C 30 °C 35°C 40 °C 45 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC 14,83 14,84 15,00 16,26 16,20 16,29 17,95 17,82 17,84 15,36 15,43 15,67 16,81 16,82 16,99 18,52 18,46 18,55 15,46 15,57 15,90 16,92 16,97 17,17 18,65 18,62 18,75 4,75 4,75 4,76 4,79 4,79 4,79 4,83 4,82 4,82 4,98 4,98 5,00 5,02 5,02 5,03 5,05 5,05 5,05 5,13 5,14 5,16 5,16 5,17 5,18 5,20 5,20 5,20 9,09 11,40 13,26 8,89 11,37 13,32 8,31 11,01 13,12 10,17 12,89 15,17 10,00 12,91 15,29 9,45 12,60 15,16 10,69 13,60 15,90 10,56 13,66 16,27 10,04 13,41 16,20 14,39 14,41 14,60 15,77 15,72 15,84 17,40 17,29 17,33 14,89 14,98 15,23 16,28 16,31 16,50 17,94 17,90 18,01 14,97 15,10 15,48 16,38 16,44 16,67 18,05 18,05 18,19 4,98 4,98 4,99 5,02 5,02 5,02 5,06 5,06 5,06 5,20 5,21 5,22 5,24 5,25 5,26 5,28 5,28 5,29 5,36 5,37 5,39 5,40 5,40 5,41 5,43 5,43 5,44 8,90 11,16 13,01 8,72 11,15 13,07 8,18 10,82 12,90 9,96 12,63 14,88 9,82 12,66 15,01 9,32 12,40 14,91 10,47 13,32 15,48 10,36 13,40 15,96 9,90 13,19 15,93 13,85 13,89 14,09 15,17 15,15 15,28 16,75 16,66 16,72 14,31 14,43 14,70 15,66 15,70 15,91 17,27 17,24 17,37 14,38 14,53 14,97 15,74 15,82 16,06 17,35 17,37 17,54 5,25 5,26 5,27 5,30 5,30 5,31 5,34 5,34 5,34 5,47 5,48 5,49 5,52 5,53 5,54 5,56 5,56 5,57 5,64 5,65 5,67 5,68 5,69 5,70 5,72 5,73 5,73 8,66 10,88 12,69 8,52 10,88 12,77 8,03 10,60 12,63 9,71 12,30 14,52 9,60 12,36 14,66 9,16 12,15 14,61 10,20 12,98 14,97 10,13 13,09 15,59 9,73 12,92 15,59 13,21 13,27 13,49 14,48 14,47 14,63 16,01 15,93 16,01 13,64 13,78 14,10 14,93 15,00 15,23 16,49 16,49 16,63 13,69 13,86 14,38 14,99 15,10 15,36 16,56 16,60 16,78 5,60 5,60 5,62 5,65 5,66 5,66 5,70 5,70 5,70 5,82 5,83 5,85 5,88 5,88 5,89 5,92 5,92 5,93 5,99 6,00 6,02 6,05 6,06 6,07 6,09 6,10 6,10 8,39 10,53 12,30 8,28 10,56 12,40 7,86 10,34 12,31 9,41 11,92 14,10 9,34 12,01 14,25 8,97 11,85 14,23 9,89 12,56 14,38 9,86 12,70 15,14 9,52 12,59 15,19 12,47 12,55 12,79 13,68 13,70 13,87 15,16 15,11 15,21 12,87 13,03 13,45 14,11 14,20 14,44 15,61 15,63 15,80 12,90 13,09 13,70 14,15 14,28 14,57 15,67 15,72 15,93 6,06 6,07 6,08 6,12 6,13 6,13 6,16 6,17 6,17 6,28 6,29 6,31 6,35 6,36 6,36 6,39 6,40 6,40 6,47 6,48 6,48 6,54 6,55 6,55 6,58 6,59 6,59 8,07 10,12 11,84 8,00 10,19 11,96 7,66 10,02 11,93 9,06 11,46 13,45 9,04 11,58 13,75 8,73 11,49 13,79 9,51 12,07 13,70 9,52 12,25 14,57 9,27 12,20 14,71 11,63 11,73 12,00 12,79 12,83 13,02 14,22 14,18 14,30 12,00 12,18 12,71 13,19 13,30 13,56 14,64 14,67 14,86 12,02 12,23 12,94 13,22 13,36 13,73 14,68 14,75 14,98 6,72 6,73 6,72 6,79 6,80 6,79 6,81 6,82 6,82 6,93 6,94 6,93 7,01 7,02 7,01 7,05 7,06 7,06 7,16 7,16 7,11 7,25 7,25 7,26 7,27 7,28 7,28 7,69 9,63 11,29 7,68 9,74 11,45 7,41 9,65 11,47 8,64 10,91 12,71 8,67 11,08 13,16 8,45 11,06 13,26 9,06 11,49 12,94 9,13 11,71 13,73 8,96 11,74 14,13 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 15 Minimum airflow 2410 m3/h Nominal airflow 3170 m3/h Maximum airflow rate 3575 Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 NC Net cooling capacity (kW) : • 12 • -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 10,12 10,07 10,04 9,98 9,94 9,90 10,34 10,28 10,26 10,21 10,17 10,13 10,46 10,40 10,38 10,33 10,29 10,25 4,46 4,69 4,85 5,09 5,25 5,42 4,47 4,77 4,85 5,09 5,26 5,42 4,56 4,88 4,96 5,21 5,38 5,56 11,66 11,59 11,53 11,44 11,38 11,32 11,95 11,85 11,82 11,74 11,68 11,62 12,10 12,00 11,98 11,89 11,84 11,78 4,68 4,91 5,07 5,32 5,49 5,66 4,65 4,95 5,03 5,27 5,44 5,60 4,72 5,03 5,11 5,36 5,53 5,70 13,19 13,08 13,01 12,89 12,81 12,73 13,55 13,40 13,37 13,25 13,17 13,09 13,74 13,59 13,56 13,44 13,36 13,28 4,89 5,12 5,29 5,54 5,72 5,90 4,82 5,13 5,20 5,45 5,61 5,78 4,87 5,17 5,25 5,50 5,67 5,84 14,71 14,57 14,47 14,32 14,22 14,12 15,13 14,94 14,89 14,75 14,65 14,55 15,35 15,17 15,12 14,97 14,88 14,77 5,08 5,33 5,50 5,76 5,95 6,14 4,98 5,29 5,37 5,62 5,79 5,97 5,01 5,32 5,40 5,65 5,82 5,99 15,31 15,16 15,05 14,89 14,78 14,67 15,75 15,55 15,50 15,34 15,23 15,12 15,99 15,79 15,74 15,58 15,48 15,37 5,16 5,41 5,58 5,85 6,04 6,24 5,05 5,36 5,44 5,69 5,86 6,04 5,06 5,37 5,45 5,70 5,88 6,06 16,21 16,04 15,92 15,74 15,62 15,49 16,69 16,46 16,41 16,23 16,11 15,99 16,95 16,72 16,67 16,49 16,37 16,25 5,28 5,53 5,71 5,99 6,18 6,38 5,14 5,46 5,54 5,79 5,97 6,16 5,15 5,46 5,54 5,79 5,97 6,15 17,69 17,49 17,35 17,14 17,00 16,85 18,24 17,97 17,90 17,69 17,55 17,41 18,53 18,27 18,20 17,99 17,85 17,71 5,47 5,73 5,92 6,21 6,42 6,64 5,30 5,62 5,71 5,97 6,16 6,35 5,29 5,60 5,69 5,95 6,13 6,32 NH Net heating capacity (kW) : SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power Application Guide • FLATAIR-AGU-MSL60-1505-E 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 3090 m3/h 16 19 22 4500 m3/h 16 19 22 16 4850 m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 20 19 22 20 °C 25 °C 30 °C 35°C 40 °C 44 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC 19,16 19,14 19,30 20,92 20,82 20,89 22,99 22,81 22,80 19,98 20,10 20,40 21,78 21,81 22,03 23,88 23,84 23,96 19,93 20,08 20,46 21,73 21,80 22,05 23,85 23,84 23,99 6,03 6,02 6,04 6,17 6,16 6,16 6,34 6,32 6,32 6,57 6,58 6,62 6,71 6,71 6,74 6,88 6,88 6,89 6,82 6,84 6,88 6,96 6,97 7,00 7,13 7,13 7,15 11,63 14,52 16,83 11,31 14,41 16,83 10,52 13,89 16,50 13,41 16,93 19,89 13,20 16,95 20,04 12,52 16,57 19,88 13,83 17,47 20,46 13,67 17,55 20,78 13,06 17,23 20,69 18,60 18,61 18,79 20,29 20,22 20,32 22,31 22,15 22,16 19,37 19,51 19,84 21,10 21,16 21,40 23,14 23,13 23,27 19,30 19,48 19,92 21,04 21,14 21,41 23,09 23,11 23,29 6,35 6,34 6,37 6,50 6,48 6,49 6,67 6,65 6,65 6,88 6,89 6,94 7,03 7,04 7,07 7,21 7,21 7,22 7,15 7,17 7,22 7,30 7,31 7,35 7,48 7,48 7,50 11,40 14,22 16,48 11,12 14,13 16,50 10,39 13,66 16,21 13,15 16,58 19,48 12,97 16,62 19,64 12,36 16,29 19,52 13,54 17,09 19,92 13,43 17,20 20,36 12,88 16,94 20,31 17,92 17,95 18,16 19,55 19,50 19,63 21,50 21,37 21,41 18,63 18,81 19,15 20,30 20,39 20,66 22,28 22,29 22,47 18,56 18,76 19,26 20,23 20,35 20,65 22,22 22,26 22,47 6,74 6,74 6,77 6,90 6,89 6,90 7,08 7,06 7,07 7,26 7,29 7,33 7,43 7,44 7,47 7,62 7,62 7,64 7,56 7,59 7,63 7,72 7,74 7,78 7,91 7,92 7,94 11,11 13,85 16,06 10,88 13,79 16,10 10,22 13,38 15,86 12,82 16,14 18,98 12,69 16,22 19,16 12,15 15,95 19,09 13,20 16,64 19,26 13,13 16,77 19,85 12,65 16,58 19,85 17,11 17,18 17,41 18,68 18,66 18,82 20,57 20,47 20,53 17,78 17,98 18,22 19,38 19,50 19,79 21,30 21,34 21,54 17,69 17,92 18,50 19,30 19,45 19,78 21,22 21,29 21,53 7,26 7,26 7,29 7,42 7,41 7,43 7,61 7,59 7,60 7,77 7,79 7,97 7,94 7,96 8,00 8,14 8,15 8,18 8,11 8,14 8,17 8,28 8,30 8,34 8,48 8,49 8,52 10,77 13,40 15,55 10,59 13,39 15,62 10,01 13,05 15,44 12,42 15,63 18,22 12,35 15,74 18,59 11,90 15,55 18,58 12,78 16,09 18,50 12,76 16,27 19,24 12,38 16,14 19,30 16,19 16,28 16,54 17,70 17,71 17,89 19,52 19,45 19,54 16,80 17,03 17,35 18,34 18,49 18,81 20,20 20,26 20,49 16,70 16,96 17,62 18,25 18,42 18,78 20,11 20,21 20,47 7,96 7,96 8,00 8,12 8,12 8,14 8,32 8,31 8,32 8,46 8,49 8,72 8,65 8,67 8,71 8,86 8,87 8,90 8,86 8,89 8,90 9,04 9,07 9,11 9,25 9,26 9,30 10,37 12,88 14,95 10,24 12,91 15,05 9,76 12,65 14,94 11,95 15,01 17,35 11,94 15,18 17,91 11,58 15,06 17,97 12,28 15,44 17,62 12,32 15,66 18,53 12,03 15,62 18,66 15,37 15,48 15,76 16,82 16,85 17,05 18,60 18,54 18,65 15,94 16,18 16,58 17,43 17,59 17,93 19,23 19,31 19,56 15,82 16,10 16,83 17,32 17,52 17,89 19,13 19,25 19,53 8,74 8,75 8,78 8,91 8,91 8,93 9,10 9,10 9,11 9,23 9,25 9,55 9,43 9,45 9,48 9,65 9,66 9,69 9,71 9,73 9,69 9,90 9,92 9,96 10,11 10,13 10,16 9,99 12,39 14,39 9,92 12,47 14,53 9,52 12,27 14,47 11,52 14,45 16,58 11,56 14,65 17,29 11,28 14,61 17,41 11,82 14,85 16,83 11,91 15,11 17,87 11,71 15,13 18,06 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 20 4500 m3/h 4850 m3/h 3090 m3/h Nominal airflow Maximum airflow rate Minimum airflow Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 GC Gross cooling capacity (kW) : -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 13,12 13,12 13,13 13,15 13,16 13,19 13,56 13,53 13,53 13,52 13,52 13,53 13,79 13,75 13,74 13,73 13,72 13,72 5,19 5,51 5,73 6,10 6,35 6,62 5,29 5,69 5,80 6,13 6,37 6,62 5,50 5,92 6,03 6,38 6,62 6,88 15,13 15,08 15,06 15,04 15,03 15,02 15,68 15,59 15,57 15,52 15,50 15,47 15,93 15,83 15,81 15,75 15,72 15,70 5,57 5,89 6,12 6,49 6,75 7,03 5,60 5,99 6,10 6,43 6,67 6,91 5,77 6,19 6,30 6,64 6,88 7,14 17,14 17,05 17,00 16,94 16,90 16,87 17,80 17,65 17,62 17,53 17,48 17,43 18,07 17,92 17,89 17,79 17,73 17,68 5,93 6,26 6,50 6,88 7,16 7,45 5,89 6,29 6,40 6,74 6,97 7,22 6,05 6,46 6,57 6,91 7,16 7,41 19,15 19,03 18,95 18,84 18,78 18,72 19,92 19,72 19,68 19,54 19,46 19,38 20,23 20,02 19,97 19,83 19,74 19,66 6,30 6,65 6,89 7,30 7,59 7,89 6,19 6,60 6,71 7,05 7,30 7,55 6,32 6,74 6,85 7,20 7,45 7,71 19,96 19,82 19,73 19,61 19,53 19,46 20,77 20,55 20,50 20,35 20,26 20,17 21,09 20,86 20,80 20,65 20,55 20,46 6,45 6,80 7,06 7,47 7,76 8,08 6,31 6,72 6,83 7,18 7,43 7,69 6,43 6,85 6,97 7,32 7,57 7,83 21,18 21,01 20,90 20,75 20,66 20,57 22,05 21,80 21,74 21,56 21,45 21,35 22,38 22,12 22,06 21,88 21,76 21,65 6,67 7,04 7,30 7,73 8,04 8,37 6,49 6,91 7,03 7,38 7,64 7,90 6,60 7,03 7,14 7,50 7,76 8,03 23,20 22,99 22,86 22,67 22,55 22,43 24,19 23,88 23,80 23,59 23,45 23,32 24,55 24,23 24,15 23,93 23,79 23,65 7,06 7,45 7,74 8,19 8,53 8,88 6,80 7,24 7,36 7,73 8,00 8,28 6,89 7,34 7,45 7,83 8,10 8,38 NH Net heating capacity (kW) : Application Guide • FLATAIR-AGU-MSL60-1505-E SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power • 13 • 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 3455 m3/h 16 19 22 5470 m3/h 16 19 22 16 5750m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 25 19 22 20 °C 25 °C 30 °C 35°C 40 °C 44 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC 23,00 22,91 23,05 25,15 24,97 25,01 27,60 27,31 27,25 24,31 24,44 24,80 26,43 26,46 26,73 28,84 28,77 28,93 24,01 24,17 24,56 26,12 26,19 26,48 28,53 28,49 28,67 7,15 7,13 7,15 7,29 7,27 7,27 7,49 7,46 7,46 7,92 7,93 7,97 8,09 8,10 8,13 8,32 8,32 8,34 8,37 8,39 8,43 8,54 8,55 8,58 8,77 8,77 8,80 13,63 16,87 19,43 13,21 16,71 19,42 12,18 16,02 18,96 15,92 20,01 23,44 15,65 20,02 23,62 14,79 19,51 23,37 16,20 20,34 23,84 16,01 20,43 24,09 15,24 20,01 23,94 22,35 22,28 22,45 24,42 24,25 24,32 26,77 26,51 26,46 23,55 23,70 24,08 25,58 25,63 25,92 27,90 27,86 28,03 23,23 23,41 23,82 25,26 25,34 25,66 27,57 27,56 27,76 7,54 7,53 7,55 7,68 7,67 7,68 7,89 7,87 7,87 8,28 8,30 8,35 8,47 8,48 8,52 8,72 8,73 8,76 8,79 8,81 8,86 8,97 8,99 9,03 9,22 9,23 9,26 13,33 16,52 19,05 12,94 16,38 19,04 11,97 15,72 18,62 15,59 19,60 22,98 15,35 19,63 23,16 14,57 19,17 22,95 15,86 19,91 23,36 15,69 20,01 23,62 15,00 19,64 23,50 21,55 21,50 21,68 23,52 23,38 23,46 25,79 25,54 25,52 22,63 22,80 23,20 24,57 24,65 24,95 26,80 26,78 26,97 22,30 22,50 22,93 24,24 24,34 24,67 26,46 26,47 26,69 8,03 8,03 8,06 8,18 8,17 8,19 8,40 8,39 8,39 8,75 8,78 8,83 8,96 8,98 9,02 9,23 9,25 9,28 9,32 9,36 9,41 9,53 9,55 9,60 9,81 9,83 9,87 12,98 16,08 18,56 12,63 15,97 18,58 11,73 15,37 18,21 15,19 19,08 22,40 15,00 19,14 22,60 14,29 18,75 22,44 15,43 19,37 22,75 15,31 19,50 23,02 14,70 19,19 22,95 20,58 20,55 20,76 22,47 22,34 22,45 24,64 24,42 24,42 21,55 21,75 22,17 23,41 23,50 23,82 25,55 25,54 25,75 21,21 21,43 21,90 23,05 23,18 23,53 25,19 25,21 25,46 8,67 8,69 8,72 8,83 8,83 8,86 9,06 9,06 9,08 9,36 9,40 9,47 9,60 9,63 9,68 9,91 9,94 9,98 10,05 10,09 10,06 10,28 10,32 10,37 10,60 10,63 10,68 12,56 15,55 17,97 12,25 15,48 18,01 11,45 14,96 17,70 14,70 18,46 21,68 14,56 18,55 21,91 13,95 18,24 21,81 14,92 18,71 21,90 14,85 18,88 22,29 14,33 18,65 22,28 19,46 19,45 19,67 21,25 21,15 21,28 23,34 23,14 23,15 20,32 20,53 20,97 22,08 22,19 22,54 24,13 24,14 24,38 19,95 20,19 20,79 21,71 21,85 22,23 23,75 23,80 24,06 9,57 9,60 9,65 9,73 9,75 9,79 9,98 9,99 10,03 10,22 10,28 10,35 10,49 10,54 10,60 10,85 10,90 10,95 11,09 11,15 11,01 11,36 11,41 11,48 11,73 11,78 11,84 12,06 14,92 17,26 11,82 14,89 17,34 11,11 14,46 17,10 14,12 17,71 20,82 14,04 17,85 21,08 13,53 17,62 21,05 14,30 17,92 20,79 14,30 18,13 21,41 13,88 17,99 21,47 18,44 18,45 18,69 20,17 20,08 20,22 22,18 21,99 22,03 19,21 19,44 28,25 20,90 21,03 21,39 22,88 22,91 23,16 18,83 19,09 19,80 20,52 20,68 21,07 22,49 22,56 22,84 10,61 10,65 10,71 10,75 10,80 10,85 11,01 11,06 11,11 11,21 11,27 7,35 11,51 11,58 11,65 11,92 11,99 12,06 12,32 12,39 12,09 12,62 12,70 12,77 13,05 13,13 13,20 11,59 14,34 16,60 11,41 14,35 16,71 10,80 14,00 16,53 13,58 17,01 26,61 13,56 17,20 20,31 13,14 17,04 20,34 13,73 17,19 19,80 13,78 17,44 20,60 13,44 17,37 20,72 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 25 5470 m3/h 5750 3455 m3/h Nominal airflow Maximum airflow rate Minimum airflow Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 NC Net cooling capacity (kW) : • 14 • -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 16,02 16,00 15,99 15,99 16,00 16,01 16,69 16,63 16,62 16,59 16,57 16,56 17,12 17,05 17,04 17,00 16,99 16,97 6,72 7,13 7,43 7,92 8,28 8,67 6,77 7,26 7,39 7,81 8,11 8,43 7,21 7,74 7,88 8,34 8,67 9,03 18,42 18,35 18,31 18,26 18,23 18,21 19,27 19,14 19,11 19,03 18,98 18,94 19,72 19,58 19,55 19,47 19,42 19,37 7,21 7,64 7,95 8,46 8,83 9,24 7,14 7,63 7,76 8,18 8,48 8,80 7,54 8,06 8,20 8,65 8,98 9,32 20,79 20,67 20,60 20,50 20,44 20,38 21,82 21,62 21,58 21,45 21,36 21,29 22,30 22,09 22,05 21,91 21,83 21,75 7,71 8,16 8,48 9,02 9,41 9,84 7,51 8,00 8,13 8,55 8,86 9,18 7,87 8,39 8,53 8,98 9,31 9,66 23,15 22,98 22,87 22,72 22,63 22,54 24,35 24,09 24,03 23,84 23,73 23,62 24,85 24,58 24,52 24,33 24,22 24,10 8,22 8,69 9,03 9,60 10,02 10,48 7,88 8,38 8,52 8,95 9,27 9,60 8,21 8,74 8,89 9,35 9,68 10,03 24,09 23,90 23,78 23,60 23,50 23,39 25,36 25,07 25,00 24,80 24,67 24,55 25,87 25,57 25,50 25,30 25,17 25,04 8,42 8,91 9,26 9,85 10,29 10,76 8,03 8,54 8,68 9,12 9,44 9,78 8,35 8,89 9,03 9,50 9,84 10,20 25,49 25,27 25,13 24,92 24,80 24,67 26,87 26,53 26,45 26,22 26,08 25,93 27,39 27,05 26,97 26,74 26,59 26,44 8,74 9,25 9,62 10,24 10,69 11,19 8,26 8,79 8,93 9,38 9,71 10,06 8,57 9,12 9,26 9,74 10,08 10,45 27,80 27,53 27,36 27,11 26,94 9,30 9,85 10,26 10,93 11,43 29,36 28,96 28,86 28,58 28,40 28,22 29,91 29,50 29,41 29,12 28,94 28,76 8,66 9,21 9,36 9,84 10,19 10,56 8,94 9,52 9,67 10,17 10,53 10,92 NH Net heating capacity (kW) : SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power Application Guide • FLATAIR-AGU-MSL60-1505-E 7 - CAPACITIES COOLING CAPACITIES Air inlet temperature at condenser (dry bulb) Indoor wet bulb 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 21 24 27 24 27 30 27 30 33 3695 m3/h 16 19 22 5060 m3/h 16 19 22 16 5500 m3/h Maximum airflow rate Nominal airflow rate Minimum airflow rate Mixed air temperature °C Indoor dry bulb FMC/H 30 19 22 20 °C 25 °C 30 °C 35°C 40 °C 41 °C NC AC SC NC AC SC NC AC SC NC AC SC NC AC SC NC AC 27,18 27,15 27,18 29,61 29,57 29,59 32,26 32,21 32,21 28,49 28,48 28,54 31,01 31,00 31,04 33,76 33,73 33,75 28,47 28,47 28,53 31,02 31,02 31,06 33,80 33,78 33,81 8,87 8,87 8,88 9,10 9,09 9,10 9,31 9,30 9,30 9,38 9,38 9,39 9,62 9,61 9,62 9,84 9,83 9,84 9,80 9,80 9,81 10,04 10,03 10,04 10,25 10,25 10,25 16,14 19,69 22,96 15,82 19,36 22,58 15,37 18,87 22,04 18,20 22,81 27,13 17,73 22,39 26,73 17,10 21,80 26,15 18,76 23,64 28,25 18,27 23,25 27,90 17,62 22,66 27,36 26,31 26,30 26,35 28,63 28,60 28,64 31,16 31,12 31,14 27,49 27,50 27,57 29,90 29,90 29,95 32,52 32,51 32,55 27,43 27,45 27,57 29,87 29,88 29,94 32,52 32,52 32,56 9,37 9,37 9,38 9,63 9,63 9,63 9,86 9,86 9,87 9,86 9,86 9,87 10,13 10,13 10,14 10,39 10,38 10,39 10,32 10,32 10,37 10,59 10,60 10,60 10,85 10,85 10,85 15,73 19,25 22,52 15,40 18,92 22,13 14,97 18,45 21,61 17,80 22,34 26,61 17,34 21,94 26,23 16,74 21,38 25,69 18,34 23,14 27,57 17,89 22,77 27,36 17,27 22,23 26,87 25,21 25,22 25,28 27,41 27,40 27,45 29,82 29,80 29,83 26,27 26,29 26,38 28,55 28,57 28,64 31,06 31,06 31,11 26,16 26,20 26,51 28,48 28,50 28,58 31,01 31,02 31,08 10,02 10,02 10,03 10,31 10,32 10,33 10,59 10,59 10,60 10,48 10,49 10,50 10,81 10,81 10,82 11,11 11,11 11,12 11,00 11,01 11,08 11,33 11,34 11,35 11,63 11,63 11,64 15,24 18,70 21,92 14,93 18,38 21,56 14,52 17,95 21,08 17,30 21,72 25,90 16,88 21,36 25,57 16,33 20,86 25,08 17,82 22,50 26,51 17,41 22,17 26,65 16,86 21,69 26,22 23,88 23,90 23,98 25,96 25,96 26,03 28,25 28,24 28,29 24,81 24,85 25,04 26,97 27,00 27,09 29,36 29,37 29,44 24,66 24,71 25,25 26,86 26,89 26,99 29,27 29,29 29,37 10,89 10,90 10,92 11,25 11,26 11,27 11,58 11,58 11,60 11,33 11,34 11,66 11,73 11,74 11,75 12,10 12,10 12,11 11,95 11,96 12,06 12,36 12,37 12,39 12,73 12,74 12,75 14,66 18,03 21,17 14,38 17,74 20,85 14,02 17,36 20,43 16,68 20,95 25,04 16,32 20,65 24,72 15,84 20,22 24,32 17,18 21,67 25,25 16,83 21,41 25,74 16,36 21,02 25,40 22,32 22,35 22,44 24,27 24,29 24,37 26,45 26,45 26,51 23,11 23,17 23,62 25,16 25,20 25,30 27,42 27,45 27,53 22,93 22,99 23,79 25,00 25,05 25,16 27,30 27,33 27,42 12,17 12,18 12,21 12,63 12,64 12,66 13,04 13,05 13,06 12,58 12,59 13,09 13,10 13,11 13,12 13,56 13,56 13,58 13,37 13,38 13,51 13,91 13,92 13,94 14,39 14,39 14,41 13,97 17,20 20,22 13,74 16,97 19,96 13,45 16,66 19,63 15,93 19,99 23,62 15,64 19,77 23,67 15,26 19,44 23,37 16,39 20,65 23,79 16,12 20,48 24,61 15,75 20,19 24,38 21,98 22,01 22,11 23,91 23,93 24,01 26,06 26,07 26,13 22,74 22,80 23,31 24,77 24,81 24,92 27,01 27,04 27,13 22,55 22,62 23,47 24,60 24,66 24,77 26,87 26,91 27,01 SC 12,50 13,82 12,52 17,01 12,54 20,01 12,99 13,60 13,00 16,80 13,02 19,77 13,42 13,32 13,43 16,51 13,45 19,45 12,90 15,76 12,91 19,77 13,46 23,31 13,45 15,49 13,46 19,57 13,48 23,43 13,94 15,13 13,94 19,26 13,96 23,16 13,74 16,21 13,76 20,42 13,89 23,47 14,32 15,96 14,33 20,27 14,35 24,35 14,82 15,61 14,83 20,00 14,84 24,15 HEATING CAPACITIES Air inlet temperature at condenser (dry bulb) FMH 30 50600 m3/h 5500 m3/h 2695 m3/h Nominal airflow Maximum airflow rate Minimum airflow Indoor Dry Bulb 15 18 20 23 25 27 15 19 20 23 25 27 15 19 20 23 25 27 GC Gross cooling capacity (kW) : -10 °C -5 °C 0 °C 5°C 7 °C 10 °C 15 °C NH AC NH AC NH AC NH AC NH AC NH AC NH AC 18,30 18,32 18,35 18,40 18,45 18,51 18,63 18,61 18,61 18,63 18,66 18,69 18,97 18,94 18,93 18,94 18,96 18,98 7,75 8,25 8,60 9,18 9,59 10,03 7,57 8,18 8,34 8,86 9,23 9,62 7,86 8,50 8,67 9,22 9,61 10,01 21,01 20,97 20,95 20,94 20,95 20,96 21,49 21,39 21,37 21,32 21,30 21,29 21,88 21,76 21,74 21,68 21,65 21,64 8,31 8,82 9,19 9,78 10,21 10,65 8,04 8,66 8,82 9,34 9,71 10,09 8,29 8,93 9,10 9,64 10,02 10,42 23,70 23,59 23,53 23,46 23,42 23,39 24,33 24,14 24,10 23,99 23,93 23,88 24,77 24,57 24,52 24,40 24,33 24,27 8,87 9,40 9,78 10,40 10,84 11,31 8,50 9,13 9,29 9,82 10,19 10,58 8,71 9,35 9,52 10,06 10,44 10,85 26,37 26,19 26,09 25,95 25,87 25,80 27,16 26,88 26,82 26,64 26,54 26,45 27,65 27,35 27,29 27,10 26,99 26,89 9,43 9,99 10,39 11,04 11,51 12,01 8,96 9,60 9,77 10,31 10,70 11,10 9,13 9,78 9,95 10,50 10,90 11,31 27,43 27,23 27,11 26,95 26,85 26,76 28,28 27,97 27,90 27,70 27,58 27,47 28,79 28,46 28,39 28,18 28,05 27,93 9,66 10,23 10,64 11,31 11,79 12,31 9,14 9,79 9,96 10,51 10,91 11,32 9,30 9,96 10,13 10,69 11,08 11,50 29,02 28,78 28,63 28,43 28,31 28,20 29,96 29,60 29,52 29,28 29,13 28,99 30,50 30,12 30,04 29,79 29,63 29,49 10,01 10,60 11,03 11,72 12,23 12,77 9,42 10,08 10,26 10,83 11,23 11,66 9,56 10,23 10,40 10,97 11,38 11,81 31,65 31,35 31,16 30,89 30,73 30,57 32,75 32,30 32,19 31,89 31,70 31,52 33,34 32,87 32,76 32,45 32,25 32,06 10,61 11,24 11,71 12,46 13,01 13,60 9,90 10,59 10,78 11,38 11,80 12,26 10,00 10,69 10,88 11,47 11,90 12,35 NH Net heating capacity (kW) : Application Guide • FLATAIR-AGU-MSL60-1505-E SC Sensible cooling capacity (kW) : Compressor absorbed AC (kW) : power • 15 • 7 - CAPACITIES CORRECTION COEFICIENTS CALCULATION OF COOLING CAPACITY DEPENDING ON AIR FLOW INDOOR & OUTDOOR AIRFLOW RATES Sizes 10-12-15-20 Sizes 25-30 Minimum Nominal Maximum Minimum Nominal Maximum Cooling capacity x 0.97 x 1.00 x 1.01 x 0.98 x 1.00 x 1.01 Sensible capacity x 0.90 x 1.00 x 1.03 x 0.95 x 1.00 x 1.02 CALCULATION OF HEATING POWER DEPENDING ON AIR FLOW INDOOR & OUTDOOR AIRFLOW RATES Sizes 10-12-15-20 Sizes 25-30 Minimum Nominal Maximum Minimum Nominal Maximum Cooling capacity x 0.98 x 1.00 x 1.01 x 0.91 x 1.00 x 1.03 Sensible capacity x 0.98 x 1.00 x 1.01 x 0.98 x 1.00 x 1.01 • 16 • Application Guide • FLATAIR-AGU-MSL60-1505-E 8 - ELECTRICAL DATA UNITS WITHOUT ELECTRICAL HEATER (STANDARD UNITS) PACKAGED UNIT (INDOOR+ OUTDOOR) TYPE 10-230 l 10 12 15 20 25 30 Maximum power (KW) 5,5 5,3 6,6 7,8 10,4 12,6 14,2 Maximum current (A) 31,7 13,7 16,0 18,6 23,6 30,0 31,0 Starting current (A) 90,2 34,1 39,7 49,0 75,3 82,3 86,9 LRC (A) 133,7 48,7 57,2 70,8 109,6 120,0 127,0 10 12 15 20 25 30 INDOOR UNIT TYPE 10-230 l Maximum power (KW) 0,4 0,4 0,4 0,8 1,0 1,3 1,3 Maximum current (A) 2,6 2,6 2,6 2,8 4,3 4,3 4,3 Starting current (A) 1,7 1,7 1,7 1,8 2,8 2,8 2,8 LRC (A) 2,6 2,6 2,6 2,8 4,3 4,3 4,3 10-230 l 10 12 15 20 25 30 Maximum power (KW) 5,1 4,9 6,1 7,0 9,4 11,3 13,0 Maximum current (A) 29,1 11,1 13,4 15,8 19,3 25,7 26,7 Starting current (A) 87,6 31,5 37,1 46,2 71,0 78,0 82,6 LRC (A) 131,1 46,1 54,6 68,0 105,3 115,7 122,7 25 30 OUTDOOR UNIT TYPE ELECTRICAL HEATER (add the following consumption for heat pump units) TYPE Power input (kW) Maximum current (A) Application Guide • FLATAIR-AGU-MSL60-1505-E 10-230 l 10 12 15 20 3 3 4.5 7.5 6 6 6 9 9 9 12 13.0 7.5 11.3 18.8 26.1 15 15 22.5 - 22.5 22.5 30 • 17 • 9 - DIMENSIONS 9.1 - UNIT DIMENSION FIX 10-12 FSC / FSH 10-12 • 18 • Application Guide • FLATAIR-AGU-MSL60-1505-E 9 - DIMENSIONS 9.1 - UNIT DIMENSION FIX 15 FSC / FSH 15 Application Guide • FLATAIR-AGU-MSL60-1505-E • 19 • 9 - DIMENSIONS 9.1 - UNIT DIMENSION FIC / FIH 20 FSC / FSH 20 • 20 • Application Guide • FLATAIR-AGU-MSL60-1505-E 9 - DIMENSIONS 9.1 - UNIT DIMENSION FIC / FIH 25-30 FSC / FSH 25-30 Application Guide • FLATAIR-AGU-MSL60-1505-E • 21 • 9 - DIMENSIONS 9.1 - UNIT DIMENSION FMC/FMH 10-12 FMC/FMH 15 • 22 • Application Guide • FLATAIR-AGU-MSL60-1505-E 9 - DIMENSIONS 9.1 - UNIT DIMENSION FMC/FMH 20 FMC/FMH 25-30 Application Guide • FLATAIR-AGU-MSL60-1505-E • 23 • 9 - DIMENSIONS 9.2.- DUCT POSITION MODELS 10-12-15 SPLIT UNIT Packaged unit Outdoor fan Outdoor fan Indoor fan Indoor fan Electrical heater Electrical heater O O ut co il Compressor or co il do co il Ind oo r or co il do Ind oo r ut Compressor MODEL 20 SPLIT UNIT Packaged unit Compressor Compressor Indoor fan Indoor fan il l oi c or do co Electrical heater d Electrical heater ut r oo ut O Outdoor fan Ind Ind oo oo rc rc oil oil O Outdoor fan MODELS 25-30 Packaged unit Indoor fan Compressor oo Ind oo rc il co l oil r oo i co or do td Ou Electrical heater Outdoor fan Outdoor fan STANDARD • 24 • rc oil t Ou Electrical heater Indoor fan OPTION Ind Compressor SPLIT UNIT ELECTRICAL BOX Application Guide • FLATAIR-AGU-MSL60-1505-E 10 - INSTALLATION 10.1 - REFRIGERANT CONNECTIONS Split units are supplied with gas and liquid lines sealed with copper covers, and located 60mm from casing. Service ports Gas Cupper cover Brazing Terminal block Liquid Split units are supplied with nitrogen gas, this must be removed and then proceed as folow: 1. Remove the nitrogen gas through the high and low 5/16” service ports located inside and provide a low vacuum for safety. 2. Remove the caps from the connecting lines. 3. Braze the piping connection lines. Select piping diameter from table 2.7.1. (When brazing refrigerant pipes, nitrogen gas must be supplied into the pipes through the service ports to remove the air). 4. Leak test: Add nitrogen gas, check that a pressure of 5 kg/cm2 has been reached and that there are no leaks in the circuit or brazing by applying soapy water to the pipes which will cause the bubbles to form where there are leaks. To detect small leaks, proceed as follows: Add nitrogen gas and check that a pressure of 25 kg/cm2 has been reached, there are no leaks if the pressure remains the same for at least 24 hours and the final pressure is not less than 10% below the initial pressure. 5. Ensure that the gas line is insulated. 6. Evacuation: Remove the nitrogen gas, connect the gauge manifold and vacuum pump to both the liquid and gas lines, fully open the gauge manifold valve and switch on the vacuum pump. Check to make sure the gauge shows a pressure of -750mm Hg. Once a level of -750mm Hg is reached, keep the vacuum pump running for at least one hour. 7. Refrigerant charge: - Check TABLE 3.1. and 3.2. for the amount of refrigerant charge, depending on the length and size of the pipe connections. - Disconnect the vacuum pump and connect to the refrigerant-charging bottle. Open the charging pump and purge the air from the hose at the pressure gauge manifold. - Set up the amount of additional refrigerant on the weighing scale, open the high pressure and charged in the liquid state. If the total amount of refrigerant charge has not been reached because the pressure is balanced, turn off the high side of the gauge manifold, turn on the unit, and add the remaining amount of the refrigerant charge required slowly through the low side of the pressure gauge. (With R-410A refrigerant, the charging bottle must be in a vertical position and charged in the liquid state). Close the pressure gauge, disconnect it from the from the service port of the unit and fit caps on the service ports. The unit is then ready to operate. During installation operations, keep gas and liquid pipes covered, in order to prevent humidity and dirt, get into them. Take special concern about refrigerant pipes are isolated. Avoid collapse on line installation. Application Guide • FLATAIR-AGU-MSL60-1505-E • 25 • 10 - INSTALLATION 10.2 - REFRIGERANT CONNECTIONS To locate the outdoor and the indoor units, refer to the following information: OUTDOOR UNIT A,B,C: Units positions L: Total length 1: Gas line 2: Liquid line INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT POSITION A: A syphon suction must be installed on the vertical line of the gas line 1, and syphons must be installed every 8 meters upward. The minimum speed suction must not be below 6 m/s. POSITION B: Tip the lines toward the outdoor unit. Make special attention to the line length longer than 10m and avoid collapse on pipe lines installation. w DISPOSICIÓN C: Install a syphon at the base of the vertical line, no more syphons are necessary. TABLE 2.7.1.: REFRIGERANT LINES SIZE REFRIGERANT LINES 10 12 15 20 25 30 Liquid 3/8” 3/8” 1/2” 1/2” 5/8” 5/8” Gas 3/4” 3/4” 7/8” 7/8” 1 1/8” 1 1/8” Maximum vertical line length (m) 15 15 15 15 15 15 Maximum number of bends 12 12 12 12 12 12 Total length 0 to 30m For other positions and lines lengths between 30 and 50m or longer, consult the commercial-technical department, pipe dimensions, syphon suction, isolations, refrigerant load, line lengths. Split units are supplied with nitrogen gas.The installer should remove this gas and charge the units with the charge of refrigerant R410A , shown in the table 2.7.2 plus the charge by additional meter shown in the table 2.7.3. • 26 • Application Guide • FLATAIR-AGU-MSL60-1505-E 10 - INSTALLATION TABLE 2.7.2 : REFRIGERANT CHARGE MODELS Cooling only Refrigerant charge R-410A Heat pump 10 12 15 20 25 30 2,14 2,57 3,55 4,46 5,38 6,15 2,5 2,93 4 4,9 6,3 7 TABLE 2.7.3 : EXTRA REFRIGERANT CHARGE R410A BY METER Liquid Gas g/m 3/8” 3/4” 57 1/2” 7/8” 108 5/8” 1 1/8” 177 10.3 - ELECTRICAL CONNECTIONS - Before making any electrical connections, ensure that all circuit breakers are open. - In order to make the electrical connections, follow the electrical diagram supplied with the unit. POWER SUPPLY POWER SUPPLY 230V SINGLE PHASE UNITS Nº of cables x section (mm²) SIZE Supply without electrical coil Supply with electrical coil 10 3x4 3 x 16 POWER SUPPLY 400V THREE-PHASE UNITS Nº of cables x section (mm²) SIZE Supply without electrical coil Supply with electrical coil 10 5 x 2,5 5x4 12 5 x 2,5 5x4 15 5x4 5x6 20 5x4 5 x 10 25 5x6 5 x 10 30 5x6 5 x 10 VOLTAGE OPERATING LIMITS: 342-462V SIZE 10 12-15-20-25-30 Application Guide • FLATAIR-AGU-MSL60-1505-E VOLTAGE LIMIT 230V-1Ph-50 Hz 198-264 V 400V-3Ph-50 Hz 400V-3Ph-50 Hz 342-462 V • 27 • 10 - INSTALLATION DC 40 THERMOSTAT, ELECTRICAL CONNECTION CONTROL PANEL GND TX+ TX- GO 90 GND TX+ TX- 91 92 93 G 94 GO G DC 40 2 x Shielded twisted pairs AWG 20. 100 m maximum. 1x Shielded twisted pair AWG20 + 2 x 1,5 mm. 200m maximum. IMPORTANT THE SHIELDED CONNECTING CABLE BETWEEN THE CONTROL PANEL AND THE UNIT MUST BE SEPARATED FROM ANY OTHER TYPE OF ELECTRICAL WIRING. CONNECT IT TO THE ELECTRIC PANEL LOCATED IN THE OUTDOOR UNIT. NOTES: - For securing and connecting the Control Panel, consult the control panel Manual supplied with the unit. - Connection between the DC40 and the unit must be made using shielded twisted pair cables (where the screens are connected to the control panel and the unit Electrical box). - The Tx+ and Tx- polarity must strictly comply with the electrical diagram supplied with the unit. • 28 • Application Guide • FLATAIR-AGU-MSL60-1505-E 11 - OPTIONS ELECTRIC HEATER Optionally, these units can contain shielded element electric heating batteries that are mounted on the inside of the unit in the schematic opposite. The electric heater must get its power from the unit’s electrical box. 10 1F UNIT STANDARD (kW) 10 3F 15 3 MEDIUM (kW) HIGH 12 20 4.5 6 - 25 30 7.5 9 9 12 MAIN SWITCH The main switch is located on the access panel to the electrical box in the outdoor section in such a way that the unit is disconnected when the panel is opened. (Refer to the size diagram a pages 20 to 31 to see the position of the electrical box access panel). Check to make sure that the main switch is large enough to handle the current for the unit if electric heaters are installed. PHASE SEQUENCER (THREE-PHASE UNIT) The phase sequencer is located in the electrical box in the outdoor section, thus assuring that the unit will not begin operation while the phase connection of the compressor is not correct. Should this occur, then just switch two phase connections. REMOTE ROOM TEMPERATURE SENSOR, REMOTE DUCT SENSOR These sensors may be used in conjunction with remote controller, allowing the controller to be mounted in a room away from the conditioned space. - REMOTE DUCT SENSOR : The sensor will be located in the return air duct, detecting the air temperature of the air being air conditioned. - REMOTE ROOM TEMPERATURE SENSOR : The sensor will be placed in the area to be air conditioned. KIT 0 DEGREES TEMPERATURE : This kit includes an crankase heater in the cooling only version , to allow working with outdoor temperatures up to 0 degrees .In heat pump orders , this crankase heater comes as standard . KIT -15 DEGREES TEMPERATURE : This kit includes a proportional regulation of the outdoor fan , to allow working with outdoor temperatures up to minus 15 degrees. FREECOOLING ONE DAMPER Fresh air damper regulated by the control , to introduce fresh air from the ambient if the temperature conditions are favourable . SECOND DAMPER FREECOOLING Second damper for the freecooling , to regulate the return air regarding the % of fresh air introduced in the room . This option is only valid with the option FREECOOLING ONE DAMPER. LOW NOISE LEVEL Compressor jacket to reduce the sound level around 2 dBA. AIRFLOW CONFIGURATIONS These units have different configurations to manage the airflow , both in the indoor and outdoor section . Application Guide • FLATAIR-AGU-MSL60-1505-E • 29 • lennoxemeia.com SALES OFFICES : BELGIUM AND LUXEMBOURG + 32 3 633 3045 FRANCE +33 1 64 76 23 23 GERMANY +49 (0) 211 950 79 600 ITALY + 39 02 495 26 200 RUSSIA +7 495 626 56 53 SPAIN +34 915 401 810 UKRAINE +380 44 585 59 10 UNITED KINGDOM AND IRELAND +44 1604 669 100 NETHERLANDS + 31 332 471 800 POLAND +48 22 58 48 610 PORTUGAL +351 229 066 050 OTHER COUNTRIES : LENNOX DISTRIBUTION +33 4 72 23 20 20 Due to Lennox’s ongoing commitment to quality, the specifications, ratings and dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency FLATAIR AGU-MSL60-1505-E
© Copyright 2026 Paperzz