4 Hrs Fire Rating [ES20/ES20M]

ES20/ES20M
Non Monitored/ Monitored
Electric Strike
Rated 4 hours on Fire Doors
Full Monitoring and High Security
v.1.6
Introduction
The ES20/20M electric strikes are fully monitored high security door strikes. The ES20/20M series are designed to
provide Power to Lock (PTL) or Power to Open (PTO) change over by rotating the “Capstan” locking mechanism
without tampering with the internal locking operations. Both ES20 and ES20M are manufactured purely from stainless
steel with a 850KG holding force, 120J impact resistance, 1 million product life cycles, and have the added advantage of
accepting DC voltages from 10 to 30 volts. In addition, the ES20M model is provided with full monitoring features
including Lock Status Sensor, Door Status Sensor and “Anti-Tamper Switch” to allow entire security control as part of a
building management system.
Specification
SPECIFICATION
ES20/ES20M
Illustration
ES20M Model, ES20 Model without DSS, LSS, ATS monitoring
Certifications
Fail Safe/Fail Secure
Lock Dimension
Lock Operating Voltage
Lock Operating Current
Lock Holding Force
Impact Force
BS476: The product has been fire rated under British Standard for 4 hours on fire door.
Can be mannualy switched between Power to Open and Power to Lock
176.0L x 44.5W x 26.5H (mm)
12~24VDC ±10%
12VDC – 220mA
24VDC – 120mA
850Kg
120J
Output Signals
Operating Temp
Weight
Operating Humidity
Surface Finish
Standard Packing
ES20M only:
Anti-Tamper Switch (ATS) COM/NO/NC
Max. 125VAC, 5A; Max. 250VAC, 3A
Door Status Signal (DSS) COM/NO/NC
Door closed or opened status output
Max. 125VAC, 3A; Max. 30VDC, 2A
Lock Status Signal (LSS) COM/NO/NC
Lock closed or opened status output
Max. 125VAC, 3A; Max. 30VDC, 2A
-10°C ~60°C
0.6Kg
0~95% (non-condensing)
Stainless Steel Body, Black powder coating
20pcs/carton
Wiring and Voltage Setting
TERMINAL
Wiring
DESCRIPTIONS
12~24VDC Power Input, 2 terminals, Red (+)/Black(-)
LSS Output, 3 terminals, C/NO/NC, Black/Yellow/Green
3A, 125VAC; 2A, 30VDC
DSS Output, 3 terminals, C/NO/NC, Black/Blue/Orange
3A, 125VAC; 2A, 30VDC
ATS Output, 3 terminals, C/NO/NC, Black/Red/White
5A, 125VAC; 3A, 250VAC
Power to Open and Power to Lock Conversion
Figure 1
Step 1:
Position the lock body as shown in Figure 1.
Figure 2
Step 2:
Remove the Rubber cap and carefully peel the sticker to reveal the end hole as shown in Figure 2.
Figure 3
Step 3:
Separate the provided screw driver pen as shown in Figure 3.
Figure 4
Step 4: Use the “-“ (slot) end of the Big Screw Driver to loosen both Capstan Release Screws as shown in Figure 4.
NOTE: DO NOT turn more than 2 full revolutions when loosen the Capstan Release Screws.
Figure 5
Step 5:
Figure 6
As shown in Figure 5, the Capstan is located inside the square cutout. The Capstan Gear can only be revealed
by inserting the provided Small Screw Driver into the End Hole as shown in Figure 6.
Figure 7
Figure 8
Step 6:
As shown in Figure 7, the Capstan Gear can be seen from the square cutout when the Capstan is pushed from
the End Hole by using the Small Screw Driver. At the same time, use the Big Screw Driver to rotate the
exposed Capstan Gear to alter the Lock function between PTO and PTL. As shown in Figure 8, rotate the
Capstan Gear towards left hand side to achieve PTL function; vice versa for PTO.
Step 7:
After the desire Lock function is switched, remove the force applying on the Capstan from the Hole End, and
tighten the Capstan Release Screws. Replace the Rubber Cap and the Sticker to complete the conversion
process.
ES20/ES20M Installations
Electric Strike and Mortise Lock Configuration:
NOTE:
As shown from the figure above, it is important to have a 1mm gap between the door latch and the front face of strike
keeper to prevent the door from exerting back pressure on the keeper while the door is closed
Installation For ES20/20M:
ES20/ES20M Series Models and Accessories
ES20/20M SERIES
Model
Accessories
MODEL
NUMBER
ES20
ES20M
ES20-LL
ES20M-LL
ES20-EL15
ES20-EL25
ES20-EL50
ES20-EL75
DESCRIPTION
Standard ES20 Electric Strike without monitoring
ES20 Electric Strike with full monitoring
Standard ES20 Electric Strike, Lipless version
ES20 Electric Strike with full monitoring, Lipless version
Extension Lip of 15mm for ES20 series
Extension Lip of 25mm for ES20 series
Extension Lip of 50mm for ES20 series
Extension Lip of 75mm for ES20 series