spitfire p370

DESCRIPTION/SUGGESTED SPECIFICATIONS
SPITFIRE
P370
4 X Faster Than
Using Spindle
Insulation Anchors
5" Insulation
Pin Capacity
Automatic Piston
Return
Power Adjustment
Insulation Fastening System—
MOST COMMON APPLICATION IS INSULATION TO CONCRETE
The P370 System is 4 times faster than the traditional installation method. It allows the installer to attach
insulation in one simple step without the use of adhesives or cutting spindle insulation anchors anymore.
ADVANTAGES
„
4 times faster than traditional insulation
„
The tool allows you to fasten the insulation
fastening method saving time and labor costs
„
Fasten the insulation directly to the concrete
no need to glue and cut spindle insulation
anchors anymore.
„
The fastening is consistent and clean looking
in tight spaces through pipes and sprinkler
systems
„
Ramset Disc Technology—loads only advance
after 10-20% of load waste
„
The tool has a 5 Year Warranty
FASTENER SELECTION CHART
PIN #
INSUL4COMBO
INSUL4.75-5COMBO
DESCRIPTION
MOST COMMON APPLICATION
Insulation Pin and Load Combo - 4”
Insulation Pin and Load Combo - 4-3/4” - 5”
4" Insulation to Concrete
4-3/4" - 5" Insulation to Concrete
APPLICATIONS
The SPITFIRE P370 is ideal for fastening insulation
to concrete. In one simple operation the fastener
will secure the insulation directly on to the concrete
no need to glue and cut spindle insulation anchors
anymore.
Part No. SPITFIRE
SPECIFICATIONS
Part No. SPITFIRE
Adaptor Part No. INSUL ADAPTOR
.25 caliber 10-shot strip loads 2, 3, 4
Part No. INSUL ADAPTOR
Weight: 6.2 pounds
Length: 19-3/4"
Muzzle Bushing O.D.: 5/8"
POWER LEVEL GUIDE FOR LOADS
All loads are color coded and
load level numbered. As the
number increases, the power
level increases.
2 ....Brown
Always start with the lightest
load. If the fastener does not set
completely, use the next higher
load and repeat the process.
4 ....Yellow
Least
Powerful
3 ....Green
Most
Powerful
Maximum Pin Length: 5" Insulation
Construction Products
Call our toll free number 800-387-9692 or visit www.itwconstruction.ca for general information.
Visit Ramset’s web site www.ramset.com for the most current product and technical information.
R 33
Spitfire P370 Performance/Submittal
RAMSET FASTENERS MAY BE SPECIFIED BY THEIR TYPE OR CATALOG NUMBER TO SATISFY FASTENING REQUIREMENTS.
PIN SPECIFICATIONS
ITW INSULATION FASTENERS
„
Plastic Sleeve made from Polyethylen High Density
„
Steel Pin Austempered to a core hardness of 50-55 HRc, Electrogalvanizing, min zinc coating 7 µm
„
The nail head is moulded in thermoplastic-elastomer to improve the corrosion resistance
„
A protection cap to improve aesthetics and to reduce thermic transmission
PERFORMANCE TABLES
Tension
INSULATION
THICKNESS MM
THE ALLOWABLE TENSION LOAD IS CALCULATED FROM THE MEAN ULTIMATE LOAD AND A SAFETY FACTOR HIGHER THAN 4.
40
45
50
60
70
75
80
100
120
67 lbs (0.30 kN)
Allowable Tension Load
Shear
INSULATION
THICKNESS MM
40
THE ALLOWABLE SHEAR LOADS ARE CALCULATED FROM THE MEAN LOADS WITH A DISPLACEMENT
EQUAL TO 10 MM AND A SAFETY FACTOR HIGHER THAN 3.
45
50
60
70
75
80
100
Polystyren Density
=15 kg/m3
Polystyren Density
=30 kg/m3
120
29 lbs (0.13 kN)
49 lbs (0.20 kN)
Pull-Through
INSULATION
THICKNESS MM
40
Rock wool density
=120 kg/m3
Polystyren Density
=15 kg/m3
Polystyren Density
=30 kg/m3
THE ALLOWABLE SHEAR LOADS ARE CALCULATED FROM THE MEAN LOADS WITH A DISPLACEMENT
EQUAL TO 10 MM AND A SAFETY FACTOR HIGHER THAN 3.
45
50
60
70
75
80
100
27 lbs (0.12 kN)
120
36 lbs (0.16 kN)
49 lbs (0.20 kN)
67 lbs (0.30 kN)
SPACING AND EDGE DISTANCE
ANCHOR DEPTH
Between 2 fixings : minimum distance of 90 mm
It must be between 25 and 31 mm to achieve the
Allowable loads given above.
Distance from free edge : minimum distance of 100 mm
APPLICATION LIMIT
The mean compressive strength of the concrete must be between C20/25 and C40/50.
R 34
Construction Products
Call our toll free number 800-387-9692 or visit www.itwconstruction.ca for general information.
Visit Ramset’s web site www.ramset.com for the most current product and technical information.