K2 Level 2 Cabling Guide

K2 Storage System
Level 2 Cabling Guide
071-8593-00
3a. Cable as shown for non-redundant (L2) system. Follow step 3b on reverse side for redundant system.
July 3, 2007
K2 Media Clients
IN
3-4
REF
GPIO
COMPOSITE LOOP
THRU
3-4
!
OUT
LTC CH 4
IN
Pus
h
Pus
h
Pus
h
SERVICE
OUT
LTC CH 3
AES/EBU CH 4
IN
OUT 1-2
1-2
3-4
3-4
UNUSED
UNUSED
IN
Pus
h
Media
Control
POWER
OUT
LTC CH 2
AES/EBU CH 3
IN
OUT1-2
1-2
3-4
To control port
on GigE switch
Control point PC
RS-422
Port 1
Port 2
SCSI
10Bt
100Bt
1000Bt
To media (iSCSI) port
on GigE switch
K2 Media Server
Fibre Channel
connection
K2
RAID STORAGE
K2
RAID STORAGE
!
POWER
SERVICE
POWER
SERVICE
!
With Level 2 RAID Expansion Chassis (if present):
No documentation included
!
3-4
RS-422
Port 3
Port 4
Media
Media
Control
FTP
RAID STORAGE
SERVICE
AES/EBU CH 2
IN
OUT 1-2
1-2
3-4
Gigabit Ethernet Switch
Control
With Level 2 RAID Primary Chassis:
Documentation CD*
Cabling Guide
Storage Release Notes
!
POWER
AES/EBU CH 1
IN
OUT 1-2
1-2
OUT
FTP/streaming
Control
K2
RAID STORAGE
SDI CH 4
IN
OUT
IN
With K2 Media Server:
No documentation included
K2
SDI CH 3
IN
OUT
LTC CH 1
With Gigabit Ethernet Switch:
Manufacturer’s documentation
!
Media
Control
Media
Control
!
SDI CH 2
IN
OUT
3-4
With K2 Media Clients:
Documentation CD*
Quick Start Guide
Client Release Notes
!
!
SDI CH 1
IN
OUT
Open boxes and find documentation.
!
!
Pus
h
!
Pus
h
1. Unpack
NOTE: K2 Media Client model
SD-00 is shown. Other
models have similar connections. Refer to each model’s
K2 Media Client Quick Start
Guide for cabling details.
L2 RAID Primary
Chassis
Media (iSCSI) ports
L2 RAID Expansion
Chassis (optional)
NOTE: 2900 series is shown.
Other HP switches have
similar connections. Refer to
the K2 Storage System
Instruction Manual for cabling
details on different models.
*
* Control ports are for control connections from
K2 Media Clients, Aurora products,
automation, etc., as well as FTP connections
from Grass Valley and 3rd party systems.
Control ports
* Read the Storage System Manual and other manuals on the
Documentation CD for complete instructions.
K2
Documentation
Xxx 2005
Software version XX
System Requirements:
Microsoft Windows and
Internet Explorer 5.5x or
Netscape 4.7x or later.
If this disc does not
auto-start, open the
home.htm file on the
disc.
.
Copyright © Thomson Broadcast
and Media Solutions, Inc.
All rights reserved.
063-xxxx-xx
- User Guide
- System Guide
- Service Manual
- Storage System Manual
- RAID Instruction Manuals
To K2 Media
Server
To media (iSCSI)
ports on GigE switch
2. Rack
PCI 2
PCI 1
Mount devices in your racks. A suggested
elevation is shown.
Gigabit Ethernet
Switches
!
K2
RAID STORAGE
K2
RAID STORAGE
!
POWER
SERVICE
POWER
SERVICE
!
!
!
PCI 3
Gb 1
0
To control port
on GigE switch
Primary
To control port
on GigE switch
Diagnostic
Cable
L2 RAID Primary
Chassis
L2 RAID Expansion
Chassis (optional)
1
Chassis
Address = 1
Expansion
4 3 2 1 ON
ID = “0”
Gb 2
1
Address ID = 1
K2 Media Servers
!
K2
Media
Clients
Fibre Channel
to RAID controller
FTP: To control port
on GigE switch
NOTE: Dell 2950 is shown.
Other Dell models have
similar connections. Refer to
the K2 Storage System
Instruction Manual for cabling
details on different models.
3b. Cable as shown for redundant (L2R) system. Follow step 3a on reverse side for non-redundant system.
K2 Media Clients
!
SDI CH 1
IN
OUT
SDI CH 2
IN
OUT
SDI CH 3
IN
OUT
SDI CH 4
IN
OUT
AES/EBU CH 1
IN
OUT 1-2
1-2
3-4
3-4
Media A
Control A
Media B
Control B
Media A
Control A
Media B
Control B
Media A
Control A
Media B
Control B
OUT
LTC CH 1
AES/EBU CH 2
IN
OUT 1-2
1-2
3-4
OUT
LTC CH 2
IN
3-4
OUT
LTC CH 3
IN
AES/EBU CH 3
IN
OUT1-2
1-2
3-4
AES/EBU CH 4
IN
OUT 1-2
1-2
3-4
3-4
REF
COMPOSITE LOOP
THRU
3-4
GPIO
!
OUT
LTC CH 4
IN
UNUSED
UNUSED
Pus
h
!
Pus
h
!
NOTE: K2 Media Client model
SD-00 is shown. Other
models have similar connections. Refer to each model’s
K2 Media Client Quick Start
Guide for cabling details.
To control port
on GigE switch B
IN
FTP/streaming
Pus
h
B
Pus
h
A
Pus
h
ISLs
Pus
h
Gigabit Ethernet
switches
Control
To media (iSCSI) port
on GigE switch B
RS-422
Port 3
Port 4
10Bt
100Bt
1000Bt
FTP
Media
Media
Control
Media
Media
Control
FTP
Control
To media (iSCSI) port
on GigE switch A
K2 Media
Servers
Control point PC
A
To control port
on GigE switch A
RS-422
Port 1
Port 2
SCSI
B
Fibre Channel
connections
K2
RAID STORAGE
K2
RAID STORAGE
!
POWER
SERVICE
POWER
SERVICE
!
L2R RAID Primary
Chassis
L2R RAID Expansion
Chassis (optional)
Media (iSCSI) ports
NOTE: 2900 series is shown.
Other HP switches have
similar connections. Refer to
the K2 Storage System
Instruction Manual for cabling
details on different models.
A
Control ports
To K2 Media
Server B
*
Media (iSCSI) ports
To K2 Media
Server A
1 Gig
ISLs
B
0
0
2
To control port
on GigE switch A
Control ports*
*Control ports are for control connections from
K2 Media Clients, Aurora products,
automation, etc., as well as FTP connections
from Grass Valley and 3rd party systems.
1
To media (iSCSI)
ports on GigE switch A
Fibre Channel
to RAID controller
Address ID = 1
Address ID = 2
PCI 2
Primary
Diagnostic
Cable
Diagnostic
Cable
A
PCI 1
PCI 3
Gb 1
Gb 2
To control port
on GigE switch A
1
Chassis
Address = 1
Expansion
FTP: To control port
on GigE switch A Heartbeat
cable
(serial)
To media (iSCSI)
ports on GigE switch B
4 3 2 1 ON
Fibre Channel
to RAID controller
ID = “0”
PCI 2
B
PCI 1
PCI 3
Gb 1
To control port
on GigE switch B
Gb 2
FTP: To control port
on GigE switch B
NOTE: Dell 2950 is shown.
Other Dell models have
similar connections. Refer to
the K2 Storage System
Instruction Manual for cabling
details on different models.
Copyright © 2007 Grass Valley, Inc.