CANADA Commercial Catalogue Water Heaters, Hot Water Supply Boilers, Storage Tanks Tankless and Specialty Products www.hotwater.com Innovation Has A Name It should come as no surprise that a company that has built its reputation on the concept of innovation, continues to lead the industry with the broadest—and, yes, the most innovative selection of water heaters and hot water supply boilers in its long and storied history. What might come as a surprise to some is the fact that we view this accomplishment as a mere beginning—an indication of even greater things still to come. For everyone here at A. O. Smith, it’s never been just about exceeding what we had achieved in the past—it’s always been about exceeding everyone’s expectations for the future. Which is why you, our customers, can count on us to provide you with the perfect water heater solution for any application—day after day, year after year. Table of Contents Innovation Continues to Lead. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Gas Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–10 Tankless . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Powered Burner Gas Water Heaters . . . . . . . . . . . . . . . . . . . . . . . 12–14 Oil-Fired Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15–17 Electric Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18–23 Circulating Water Heaters & Hot Water Supply Boilers . . . . . . . . 24–33 Electric Boilers & Hot Water Generators . . . . . . . . . . . . . . . . . . . . 34–35 Storage Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36–37 iCOMM™ Remote Monitoring System. . . . . . . . . . . . . . . . . . . . . . . . . 38 Building Management System BACnet and MODBUS Interface. . . . . 39 Commercial Line Overview and Support Network. . . . . . . . . . . . 40–41 C.J. Smith establishes the company A. O. Smith Patents the glass-lined water heater Launches the Cyclone® Commerical Water Heater Cyclone® Mxi Launch Provides fully modulating combustion to precisely meet demands. Exclusive advanced LCD electronic control, with built-in diagnostics. Top mounted components include new spark ignition, quiet operation burner and blower combination. Enhanced PermaGlas® glass lining process that provides superior tank protection against corrosion. For more information, please visit 4 www.hotwater.com CFC-Free Foam Insulation n Minimizes radiant heat loss n Carries inlet water deep into tank Hot Surface Ignition n Solid state ignition surface that does not flutter or blow out n Provides increased reliability and efficiency over spark ignition systems n Eliminates the pilot and saves energy User-Friendly Enhanced-Flow Brass Drain Valve S olid brass, tamper resistant, enhanced-flow, ball type drain valve n Uses a standard female hose fitting that allows for fast and easy draining during maintenance n Designed for easy operation, this valve includes an integral screwdriver slot that features a ¼ turn (open/close) radius, which not only permits full straightthrough water flow but also a quick and positive shut off Powered Venting n State-of-the-art electronic gas control provides more precise temperautre control n LED control light displays operation status and diagnostic information Blue Diamond® Glass Coating n Provides superior corrosion resistance compared to the industry standard glass lining Anode T ank-mounted, screw-in magnesium anode for longer tank life rovides more venting flexibility P and savings. A new quiet blower allows exhaust venting through the roof or sidewall with plastic pipe such as ULC S636 PVC, CPVC or polypropylene n U p to 125 equivalent feet of pipe makes installation easy in any situation n B TF-80 is a Category 3 (positive pressure non-condensing) appliance n Factory-Installed Temperature and Pressure Relief Valve n High-Input n Conservationist® Power Vent BTF Model n Dip Tube n GAS WATER HEATERS 80% thermal efficient - approved for use in combined appliance applications. 7 6,000 BTU input assures plenty of hot water is available by providing faster recovery rates and higher first hour draws P roperly sized for each model (Specify if your local code requires a special T&P) LOW LEAD CONTENT 3-Year Limited Tank/1-Year Limited Parts Warranty Burner n High-input, multi-port burner for improved combustion efficiency MODEL CAPACITY USG (L) INPUT BTU/h MAXIMUM CERTIFIED ALTITUDE FT (M) RECOVERY 100°F (56°C) TEMP. RISE HEIGHT IN (CM) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) BTF-80 75 (284) 76,000 10,100 (3,078) 74 (280) 70 5/8 (179) 26 (66) 277 (126) GPH (LPH) 5 GAS WATER HEATERS Conservationist® Atmospheric Vent BT Models 80% thermal efficiency, ideal for light-duty applications. BT models provide reliable, efficient service for light-duty applications such as office buildings and duplex/fourplex apartment homes. Heavy Gauge Steel Jacket n Finished with baked enamel over bonderized undercoat Glass-Lined Tank n P rotects steel tank from corrosion and maximizes tank life Fully Automatic Controls with Safety Shut Off Accurate, dependable control system requires no electric connections n Fixed automatic gas shut off device for added safety n Temperature adjustable up to 181°F n Draft Diverter n L ow profile diverter furnished as standard equipment Hand Hole Clean Out n A llows for easy tank cleaning Foam Insulation n S aves fuel and helps reduce standby heat loss Maximum Working Pressure n LOW LEAD CONTENT 1 50 psi Maximum Gas Inlet Pressure n 1 4” W.C. Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 n C SA certified and ASME rated T&P relief valve n N ot recommended for sanitation rinse 3-Year Limited Tank/1-Year Limited Parts Warranty 6 APPROX. SHIPPING WEIGHT LB (KG) MODEL CAPACITY USG (L) INPUT BTU/h MAXIMUM CERTIFIED ALTITUDE FT (M) BT-80 74 (280) 75,100 7,700 (2,347) 73 (275) 61 1/8 (155) 26 1/2 (67) 275 (125) BT-100 98 (371) 75,100 7,700 (2,347) 73 (275) 68 5/8 (174) 27 3/4 (71) 350 (159) RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) HEIGHT IN (CM) DIAMETER IN (CM) Factory-Installed Draft Diverter and Flue Damper (BTRC 120-400 models) L ow-profile draft diverter helps for installation in tight spaces n A utomatic motorized flue damper helps minimize standby heat loss n B TRC 500 model features induced draft design and no damper Fully Automatic Control System M anual reset gas shut off device prevents excessive water temperature n A djustable thermostat with 120ºF–180ºF range n G as pressure regulator and pilot filter n n Water Connections n F or ease of installation, most models feature water connections on the front, top or rear of unit Hand Hole Clean Out n n Can be commonly vented with other Category I appliances, using standard metal type “B” vent n Optional power vent kits available to allow sidewall venting up to 100 equivalent feet n BTRC 120-200 P/N 197515-000; BTRC 250-500 P/N 197515-001 Eliminator™ Self Cleaning System n Directs incoming cold water to sweep the bottom of the tank so sediment does not accumulate n Reduced sediment buildup maintains rated thermal efficiency and reduces water heating costs CoreGard™ Anode Rod n S tainless steel core provides additional corrosion protection Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Factory-Installed, CSA Certified and ASME Rated T&P Relief Valve n Properly sized for each model A llows easy access to tank interior for cleaning Category I Appliance PermaGlas® Ultra Coat™ Glass Lining E xclusive process provides superior protection against corrosion n Applied after tank construction, the tank is mechanically maneuvered to ensure the liquid glass covers all surfaces for superior protection LOW LEAD CONTENT HLW 3-Year Limited Tank/1-Year Limited Parts Warranty On Select Models Approved to NSF Standard 5 with Optional Leg Kit APPROX. SHIPPING WEIGHT LB (KG) CAPACITY USG (L) INPUT BTU/h RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) VENT DIAMETER (IN) HEIGHT* IN (CM) DIAMETER IN (CM) STD ASME BTRC-120 71 (268) 120,000 116 (439) 5 69 3/4 (177) 27 3/4 (71) 512 (232) - BTRC-154 81 (307) 154,000 149 (564) 6 73 (185) 27 3/4 (71) 552 (250) - BTRC-180 76 (288) 180,000 174 (659) 6 67 ½ (171) 27 3/4 (71) 576 (261) - BTRC-197 95 (360) 199,000 193 (731) 6 75 (191) 27 3/4 (71) 645 (293) - BTRC-199 76 (288) 199,000 193 (731) 6 67 ½ (171) 27 3/4 (71) 592 (269) - BTRC-200A 100 (379) 199,000 193 (731) 6 72 (183) 30 1/4 (77) - 715 (324) BTRC-250A 100 (379) 250,000 242 (916) 8 72 (183) 30 1/4 (77) - 715 (324) BTRC-251(A) 65 (246) 251,000 243 (920) 8 75 (191) 27 3/4 (71) 660 (299) 661 (300) BTRC-275A 100 (379) 275,000 267 (1,011) 8 72 (183) 30 1/4 (77) - 721 (327) BTRC-305(A) 65 (246) 305,000 296 (1,120) 8 75 (191) 27 3/4 (71) 659 (299) 672 (305) BTRC-365(A) 65 (246) 365,000 349 (1,321) 8 79 ½ (202) 27 3/4 (71) 670 (304) 661 (300) BTRC-400A 100 (379) 390,000 387 (1,465) 8 75 1/2 (192) 30 1/4 (77) - 844 (383) BTRC-500A 85 (322) 500,000 479 (1,813) 8 81 ½ (207) 27 3/4 (71) - 824 (374) MODEL GAS WATER HEATERS Master-Fit® Atmospheric Vent BTRC Models 80% thermal efficiency, self-cleaning, easy-to-install. (A) - Available with ASME tank construction * Height to top of drafthood High altitude models also available. 7 GAS WATER HEATERS Cyclone® MXi Modulating BTH Gas Models Modulating burner advances the Cyclone to higher levels of efficiency. The full line of A. O. Smith Cyclone MXi condensing water heaters have been designed to provide years of dependable service and feature industry leading technology. Models are available from 120,000 to 500,000 BTU/h and all deliver thermal efficiencies of 95% and higher. The unique helical coil heat exchanger limits weld joints for optimal service life while maximizing heat transfer. Cyclone is the industry leader in high efficiency commercial water heating with over a quarter million sold since 1996. The MXi modulating models adjust firing rate to the specific demand further increasing efficiency and money savings. Submerged Combustion Chamber with Helical Heat Exchanger Coil P ositioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber n D irect spark ignition for years of worry free operation n Spiral heat exchanger keeps hot burner gases swirling and uses centrifugal force to maximize efficiency of heat transfer to water in tank n Spiral heat exchanger reduces lime scale from forming on water-side surfaces, which maintains energy efficiency over time n Intelligent Control System with LCD Display E xclusive A. O. Smith designed control system P rovides detailed water heater status information n P recise temperature control adjustable from 90°F to 180°F n B uilt-in diagnostics n R un history information n iCOMM™ compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information n C onnect to an existing building management system via BACnet or MODBUS with optional ICC gateway n n Powered Anodes Standard on All Models ANSl/NSF-5 1.888. WATER0 2 8 Provides long-lasting tank protection in varying water conditions n Powered anodes are non-sacrificial n Automatically adjusts output needed to properly protect the tank n GAS WATER HEATERS Cyclone® MXi Modulating BTH Gas Models Mechanical Venting Versatility n Flexibility of conventional power venting or direct venting vertically or through a sidewall n For added flexibility, easy install and access, the exhaust and condensate connections are located in the front of the heater n Installations require ULC S636 PVC, CPVC, polypropylene or AL29-4C® stainless steel pipe for intake and exhaust PermaGlas® Ultra Coat™ Glass Lining n G lass coating is applied using a liquid slush coating technique to ensure uniform coating n H eat exchanger coil is glassed both externally and internally for optimum protection High Efficiency Modulating Pre-Mix Powered Burner n D own-fired pre-mix burner provides optimum efficiency and quiet operation n T op-mounted burner position prevents condensation from affecting burner operation Space-Saving Design for Installation Flexibility n Reduced footprint, ease of service, protection from water damage in case of flooding n Easy to remove top cover for convenient access to serviceable parts n 0” installation clearances on sides and rear, 1-1/2” installation clearance on top, 4” alcove installation clearance in front hand hole clean out of unit n Hand hole clean out allows easy access to tank interior for cleaning n 0” clearance to combustibles, approved for installation on combustible floors 3-Year Limited Tank/1-Year Limited Parts Warranty APPROX. SHIPPING WEIGHT LB (KG) MODEL CAPACITY USG (L) INPUT BTU/h RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) VENT DIAMETER (IN) HEIGHT IN (CM) DIAMETER IN (CM) STD ASME BTH-120(A) 60 (227) 120,000 138 (523) 3, 4 55 ½ (141) 27 ¾ (71) 460 (208) 490 (220) BTH-150(A) 100 (379) 150,000 178 (674) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251) BTH-199(A) 100 (379) 199,000 235 (890) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251) BTH-250(A) 100 (379) 250,000 291 (1,101) 3, 4 76 ½ (195) 27 ¾ (71) 523 (237) 553 (251) BTH-300A 119 (451) 300,000 349 (1,321) 4, 6 75 ¾ (192) 33 1/8 (84) - 855 (387) BTH-400A 119 (451) 399,900 460 (1,743) 4, 6 75 ¾ (192) 33 1/8 (84) - 855 (387) BTH-500A 119 (451) 499,900 576 (2,179) 4, 6 75 ¾ (192) 33 1/8 (84) - 855 (387) (A) -Available with ASME tank construction 9 GAS WATER HEATERS Cyclone® Xi™ Available up to 96% thermal efficiency, venting flexibility, outstanding value. BTX and BTXL Gas Models The Cyclone Xi is a light-duty, power direct vent, fully condensing commercial gas water heater with an internal helical heat exchanger. This helical heat exchanger helps Cyclone Xi achieve 96% thermal efficiency and deliver outstanding hot water output. ENERGY STAR® Qualified Submerged Combustion Chamber, with Helical Heat Exchanger Coil P ositioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber n S piral heat exchanger reduces the accumulation of lime scale, to help maintain higher efficiency performance over time n PermaGlas® Ultra Coat™ Glass Lining n n E xclusive process provides superior corrosion protection B oth sides of heat exchanger coil are lined for protection against flue gas condensate inside coil Advanced Electronic Control System with LCD Display iCOMMTM compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information n P recise temperature control n C onnect to an existing building management system via BACnet or MODBUS with optional ICC gateway n B uilt-in diagnostics n 1.888. WATER0 2 Venting Options U ses inexpensive ULC S636 PVC, CPVC or polypropylene pipe vertically through the roof or horizontally through the wall (see instruction manual for complete venting instructions and allowable vent lengths) n Optional concentric vent and sidewall termination kits available n Side-Mounted Hot and Cold Recirculating Taps A llows Cyclone Xi to be installed as part of combination space heating/water heating applications n P lugs for the recirculating taps are factory installed n 3-Year Limited Tank/1-Year Limited Parts Warranty 10 MODEL CAPACITY USG (L) INPUT BTU/h MAXIMUM CERTIFIED ALTITUDE FT (M) RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) VENT DIAMETER (IN) HEIGHT IN (CM) BTX-100 50 (189) 100,000 10,100 (3,078) 116 (439) 2, 3 66 ¾ (170) 22 (56) 255 (116) BTXL-100 75 (284) 100,000 10,100 (3,078) 116 (439) 2, 3 65 ¼ (166) 27 3/4 (71) 382 (173) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) GAS WATER HEATERS Cyclone® HE™ BTX-80 76,000 BTU, 90% thermal efficiency. The 50-gallon light-duty power vent Cyclone HE is designed to produce more hot water than any commercial gas water heater in its class. Thanks to the internal helical heat exchanger—similar to the design of the industryleading Cyclone MXi and Xi™ models—the unit achieves 90% thermal efficiency. With its small footprint and easy installation, the Cyclone HE delivers heavy-duty performance for light-duty applications, making it the perfect choice for restaurants, offices and other light-duty applications. Helical Coil Heat Exchanger S ubmerged heat exchanger provides much greater heat transfer surface than standard straight flue tube n P roduces 90% thermal efficiency, which saves money on operating costs and increases hot water output compared to standard-efficiency water heaters n Versatile Power Vent Design n S ystem allows combined vertical and horizontal vent runs using ULC S636 PVC or CPVC pipe Modular Blower P VC Vent Attenuation Assembly (VAA) supplied for applications where extra-quiet operation is essential n C ondensate drain supplied n High-Output with Small Footprint n 2 2˝ diameter, combined with 90% efficiency and 76,000 BTU input means the Cyclone HE can be installed in less space than a larger 75-gallon unit with equal or better performance LOW LEAD CONTENT Blue Diamond® Glass Coating n P rovides superior corrosion resistance compared to industry standard glass lining Intelli-Vent™ * Gas Control E quipped with long-lasting silicon nitride hot surface igniter—no standing pilot n A dvanced electronics for more precise control of water temperature and simplified system diagnostics n 181°F maximum temperature setting n Side-Mounted Hot and Cold Recirculating Taps A llows Cyclone HE to be installed as part of combination space heating/water heating applications, or any system requiring a recirculating hot water loop n P lugs for the recirculating taps are factory-installed n Two Heavy-Duty Anode Rods n P rovide advanced corrosion protection *Intelli-Vent™ is a trademark of Emerson Electric Company 11 GAS WATER HEATERS Superior Heat Transfer By utilizing the innovative internal heat exchanger coil, the Cyclone® HE™ provides superior heat transfer capabilities, resulting in an unprecedented 90% thermal efficiency, far beyond a standard water heater design. Gallon for gallon, the Cyclone HE will heat water for significantly less, resulting in substantial savings on energy costs. With as much power as larger water heaters in a standard 50-gallon footprint, the Cyclone HE is the natural choice for upgrading during a renovation. And the versatile power vent design allows combined vertical and horizontal vent runs of up to 128 equivalent feet. Cyclone HE provides superior savings on energy costs. The classic Cyclone helical heat exchanger coil delivers 90% thermal efficiency. MODEL CAPACITY USG (L) INPUT BTU/h RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) HEIGHT IN (CM) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) BTX-80 50 (189) 76,000 83 (314) 71 1/ 8 (180) 22 (56) 210 (95) SUGGESTED SPECIFICATION Natural Gas water heater(s) shall be A. O. Smith Cyclone® HE™ model BTX-80, with 90% thermal efficiency, a storage capacity of 50 gallons, an input rating of 76,000 BTU per hour, a recovery rating of 83 gallons per hour at 100ºF rise and a maximum hydrostatic working pressure of 150 psi. Water heater(s) shall be of power vent design using 2˝, 3˝ or 4˝ ULC S636 PVC or CPVC pipe for horizontal and/or vertical vent runs. 3-Year Limited Tank/1-Year Limited Parts Warranty 12 GAS WATER HEATERS Endless hot water*. Compact Size. Energy Conservation. Tankless Models A. O. Smith commercial tankless water heaters will provide a steady flow of hot water for as long as your application needs it in the most energy efficient way possible. Because our tankless water heaters only activate when hot water is being used, no standby energy losses are incurred providing efficient heating and conserving gas energy. On top of all this, an A. O. Smith tankless water heater takes up much less space than conventional tank-type water heaters or boilers allowing for additional storage space and flexibility. Commercial Grade Copper Heat Exchanger Stronger than regular copper (C1220) and transfers heat faster than stainless steel n Resilient against erosion n Energy Efficient Units only heat the water being used so there is no standby energy loss n 540H condensing model is ENERGY STAR® qualified n Venting Flexibility (Condensing Only) n n etal vent collar for PVC with no gluing or cutting M Approved with ULC S636 PVC, CPVC, polypropylene or Cat. III/IV stainless steel pipe Non-Condensing Concentric Vent n n Vents with contractor-preferred concentric venting F ield convertible from natural gas to propane out of the box Multiple Unit Installation n n asy Link – Up to 4 units with no additional accessories E Multi Link – Up to 20 540H and 510C units with TM-MC02 system controller (10 units with 910 model) Dual Internal Freeze Protection 10-Year Limited Heat Exchanger/5-Year Limited Parts Warranty INPUT BTU/h MODEL MINIMUM MAXIMUM ENERGY FACTOR/ THERMAL EFFICIENCY C FLOW RATE GPM 30°F RISE 70°F RISE US HEIGHT IN (CM) WIDTH IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 17 3/4 (45) 10 ¾ (27) 58 (26) CONDENSING ATI-540H 13,000 199,000 0.95 10.0 5.4 22 ½ (57) NON-CONDENSING ATI-510 11,000 199,000 0.82 10.0 4.7 20 1/4 (52) 13 ¾ (35) 9 ½ (24) 39 (18) ATI-510C 15,000 199,000 0.82 10.0 4.7 20 ½ (52) 13 ¾ (35) 10 ½ (27) 51 (23) ATI-910(A) 15,000 380,000 80% (NG) 82% (LP) 14.5 8.7 25 1/4 (64) 24 7/8 (63) 12 ¼ (31) 112 (51) (A) – ASME version available *When sized appropriately. 13 GAS WATER HEATERS Large Volume Power Burner BTP Gas Models BTP-150-140 through BTP-600-2500. The high-volume powered burner line includes the largest, most powerful A. O. Smith tank-type gas water heaters. With tank capacities up to 600 gallons and firing capacities up to 2.5 million BTU per hour, these large-volume high-output water heaters are capable of producing over 3,000 gallons of hot water per hour at an 80°F rise. These heavy-duty industrialgrade water heaters are designed and built to handle the most demanding hot water heating requirements of large commercial and industrial users. Powered Gas Burner S uitable for natural or propane gas E lectronic flame safeguard control with intermittent spark ignition n M ain and pilot automatic gas valves with gas pressure regulators n D iaphragm air switch for proof of blower operation n F lame inspection port n n Fully Automatic Controls with Safety Shut Off H igh temperature limit control (manual reset) ASME-rated T&P valve n H inged door control compartment for easy access n U pper and lower thermostats for accurate temperature control n S tandard control is for 120°F-180°F water service n F actory-installed low water cut off n n Blue Diamond® Glass Lining HLW P roprietary A. O. Smith glass lining provides superior coverage and unmatched durability n E quipped with multiple anode rods for additional corrosion protection n LOW LEAD CONTENT Heavy-Duty Jacket H eavy gauge steel jacket with baked powder coated finish for durability n T wo 3˝ hand hole inspection openings n Maximum Hydrostatic Working Pressure n 160 psi for all models Professional Start-Up Service n A ssures proper installation and adjusts burner for clean combustion and most efficient operation Codes and Standards D esign-certified by UL (Underwriters Laboratories), according to ANSI Z21.10.3 - 4.3 CSA standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 n 14 14 GAS WATER HEATERS All models are approved for use in combined appliance applications. Other BTP Features wo layers of high-temperature ceramic fiber T insulation in combustion chamber n Mounted on rugged channel iron skids n National board stamping n Barometric draft regulator n 120V control circuit n Drain valve n 180°F water service thermostats n 3-Year Limited Tank/1-Year Limited Parts Warranty n F or complete information, consult written warranty or contact A. O. Smith BTP Options Factory mutual approved control arrangement High or low water pressure switch n M odular graphic burner systems management on heaters with 270,000 BTU/h input and over n n FIRST HOUR RATING GPH (LPH) RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) MOTOR HP 120V 60 Hz 1 PHASE VENT DIAMETER (IN) HEIGHT IN (CM) DIAMETER IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 140,000 256 (969) 136 (515) 1/15 HP 2.2 AMPS 5 84 1/2 (215) 36 1/2 (93) 48 (122) 1,292 (586) 199,000 313 (1,185) 193 (731) 1/15 HP 2.2 AMPS 6 84 1/2 (215) 36 1/2 (93) 48 (122) 1,292 (586) 150 (568) 255,000 367 (1,389) 247 (935) 1/15 HP 2.2 AMPS 6 84 1/2 (215) 36 1/2 (93) 48 (122) 1,292 (586) BTP-150-270 150 (568) 270.000 382 (1,446) 262 (992) 1/4 HP 4.6 AMPS 6 84 1/2 (215) 36 1/2 (93) 58 1/2 (149) 1,397 (634) BTP-150-400 150 (568) 400,000 507 (1,919) 387 (1,465) 1/4 HP 4.6 AMPS 7 84 1/2 (215) 36 1/2 (93) 58 1/2 (149) 1,397 (634) BTP-150-540 150 (568) 540,000 644 (2,438) 524 (1,984) 1/4 HP 4.6 AMPS 8 84 1/2 (215) 36 1/2 (93) 58 1/2 (149) 1,505 (683) BTP-150-720 150 (568) 720,000 818 (3,096) 698 (2,642) 1/3 HP 5.5 AMPS 10 84 1/2 (215) 36 1/2 (93) 58 1/2 (149) 1,510 (685) BTP-200-300 200 (757) 300,000 451 (1,707) 291 (1,102) 1/4 HP 4.6 AMPS 6 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,098 (952) BTP-200-600 200 (757) 600,000 742 (2,809) 582 (2,203) 1/4 HP 4.6 AMPS 8 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,098 (952) BTP-200-800 200 (757) 800,000 936 (3,543) 776 (2,937) 1/3 HP 5.5 AMPS 10 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,103 (954) BTP-200-1000 200 (757) 1,000,000 1,130 (4,278) 970 (3,672) 1/3 HP 5.5 AMPS 10 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,103 (954) BTP-200-1250 200 (757) 1,250,000 1,372 (5,194) 1,212 (4,588) 1/2 HP 7.4 AMPS 12 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,467 (1,119) BTP-200-1500 200 (757) 1,500,000 1,615 (6,113) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 83 1/2 (212) 44 3/4 (114) 67 1/2 (171) 2,675 (1,213) BTP-300-300 300 (1,136) 300,000 531 (2,010) 291 (1,102) 1/4 HP 4.6 AMPS 6 91 1/2 (232) 44 3/4 (114) 67 1/2 (171) 2,150 (975) BTP-300-600 300 (1,136) 600,000 822 (3,112) 582 (2,203) 1/4 HP 4.6 AMPS 8 91 1/2 (232) 44 3/4 (114) 67 1/2 (171) 2,150 (975) BTP-300-800 300 (1,136) 800,000 1,016 (3,846) 776 (2,937) 1/3 HP 5.5 AMPS 10 91 1/2 (232) 44 3/4 (114) 67 1/2 (171) 2,308 (1,047) BTP-300-1000 300 (1,136) 1,000,000 1,210 (4,580) 970 (3,672) 1/3 HP 5.5 AMPS 10 91 1/2 (232) 44 3/4 (114) 67 1/2 (171) 2,308 (1,047) BTP-300-1250 300 (1,136) 1,250,000 1,452 (5,496) 1,212 (4,588) 1/2 HP 7.4 AMPS 12 91 1/2 (232) 44 3/4 (114) 67 1/2 (171) 2,584 (1,172) BTP-300-1500 300 (1,136) 1,500,000 1,695 (6,416) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 91 1/2 (232) 44 3/4 (114) 82 1/2 (210) 2,774 (1,258) BTP-400-600 400 (1,514) 600,000 902 (3,414) 582 (2,203) 1/4 HP 4.6 AMPS 8 91 1/2 (232) 55 (140) 77 1/2 (197) 3,207 (1,455) BTP-400-800 400 (1,514) 800,000 1,096 (4,149) 776 (2,937) 1/3 HP 5.5 AMPS 10 91 1/2 (232) 55 (140) 77 1/2 (197) 3,212 (1,457) BTP-400-1000 400 (1,514) 1,000,000 1,290 (4,883) 970 (3,672) 1/3 HP 5.5 AMPS 10 91 1/2 (232) 55 (140) 77 1/2 (197) 3,212 (1,457) BTP-400-1250 400 (1,514) 1,250,000 1,532 (5,799) 1,212 (4,588) 1/3 HP 5.5 AMPS 12 91 1/2 (232) 55 (140) 77 1/2 (197) 3,212 (1,457) BTP-400-1500 400 (1,514) 1,500,000 1,775 (6,719) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 91 1/2 (232) 55 (140) 92 1/2 (235) 3,402 (1,543) BTP-400-1750 400 (1,514) 1,750,000 2,017 (7,635) 1,697 (6,424) 1/2 HP 7.4 AMPS 14 91 1/2 (232) 55 (140) 92 1/2 (235) 3,528 (1,600) BTP-400-2000 400 (1,514) 2,000,000 2,259 (8,551) 1,939 (7,340) 1/2 HP 7.4 AMPS 14 99 1/2 (253) 55 (140) 92 1/2 (235) 3,669 (1,664) BTP-500-2250 500 (1,893) 2,250,000 2,582 (9,774) 2,182 (8,260) 3/4 HP 10.2 AMPS 16 110 (279) 55 (140) 92 1/2 (235) 4,277 (1,940) BTP-500-2500 500 (1,893) 2,500,000 2,824 (10,690) 2,424 (9,176) 3/4 HP 10.2 AMPS 16 110 (279) 55 (140) 92 1/2 (235) 4,419 (2,004) BTP-600-720 600 (2,271) 720,000 1,178 (4,459) 698 (2,642) 1/3 HP 5.5 AMPS 10 115 (292) 55 (140) 77 1/2 (197) 3,667 (1,663) BTP-600-1000 600 (2,271) 1,000,000 1,450 (5,489) 970 (3,672) 1/3 HP 5.5 AMPS 10 115 (292) 55 (140) 77 1/2 (197) 3,667 (1,663) BTP-600-1250 600 (2,271) 1,250,000 1,692 (6,405) 1,212 (4,588) 1/3 HP 5.5 AMPS 12 115 (292) 55 (140) 77 1/2 (197) 3,667 (1,663) BTP-600-1500 600 (2,271) 1,500,000 1,935 (7,325) 1,455 (5,508) 1/2 HP 7.4 AMPS 12 115 (292) 55 (140) 92 1/2 (235) 3,837 (1,740) BTP-600-1750 600 (2,271) 1,750,000 2,177 (8,241) 1,697 (6,424) 1/2 HP 7.4 AMPS 14 115 (292) 55 (140) 92 1/2 (235) 3,837 (1,740) BTP-600-2000 600 (2,271) 2,000,000 2,419 (9,157) 1,939 (7,340) 1/2 HP 7.4 AMPS 14 115 (292) 55 (140) 92 1/2 (235) 3,837 (1,740) BTP-600-2250 600 (2,271) 2,250,000 2,662 (10,077) 2,182 (8,260) 3/4 HP 10.2 AMPS 16 115 (292) 55 (140) 92 1/2 (235) 4,477 (2,031) BTP-600-2500 600 (2,271) 2,500,000 2,904 (10,993) 2,424 (9,176) 3/4 HP 10.2 AMPS 16 115 (292) 55 (140) 92 1/2 (235) 4,619 (2,095) MODEL CAPACITY USG (L) INPUT BTU/h BTP-150-140 150 (568) BTP-150-199 150 (568) BTP-150-255 Field certification required on all BTP installations in Canada. 15 GAS WATER HEATERS Small Volume Power Burner BTP Gas Models Powered burner models provide thermal efficiencies of 80%. These gas powered burner models provide an outstanding thermal efficiency of 80% or more and are suitable for small to medium-sized commercial applications. Small-Volume BTP Quality Features U L listed power burner A SME construction n F actory-installed ASME-rated T&P valve properly sized for each model n H and hole clean outs for easy maintenance n F ully automatic controls ensure safe, efficient operation n B arometric draft damper ensures correct air flow in the vent n P rofessional start-up provided n M ounted on rugged channel iron skids for easy transport during installation n M ultiple anodes for extra protection against tank corrosion n F lame inspection port opening for visual inspection of flame characteristics during operation n S park pilot ignition n F actory-installed burner for easy installation n n Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 3-Year Limited Tank/1-Year Limited Parts Warranty n LOW LEAD CONTENT F actory start-up is required to validate warranty Options n 3 vent options: atmospheric, sidewall and direct-vent (to be specified at time of order) Shown here is the powered burner combustion chamber used in the BTP(V)-540A, BTP(V)-650A and BTP(V)-740A models. These models can vent through a sidewall up to 100 equivalent feet without an external blower. 1. Exclusive PermaGlas® Ultra Coat™ Glass-Lined Tank protects tank surfaces and all welds from the corrosive effects of hot water. 2. P atented Dome Combustion Chamber ensures optimum flue loading and efficient heat transfer by balancing pressure inside combustion chamber. 3. P re-mix Combustion System provides super clean low-NOx flame. Helps eliminate hot spots and uneven heat transfer. 4. S ealed Combustion Chamber reduces heat loss. HLW MODEL CAPACITY USG (L) INPUT BTU/h FIRST HOUR RATING GPH (LPH) RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) VENT DIAMETER (IN) HEIGHT IN (CM) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) BTP(V)-540A 85 (322) 540,000 583 (2,207) 523 (1,980) 9 80 ¾ (205) 29 1/2 (75) 950 (431) BTP(V)-650A 85 (322) 650,000 690 (2,612) 630 (2,385) 9 80 ¾ (205) 29 1/2 (75) 950 (431) BTP(V)-740A 85 (322) 740,000 778 (2,945) 718 (2,718) 9 80 ¾ (205) 29 1/2 (75) 950 (431) (V) - Available for Sidewall Vent or Direct Vent 16 OIL-FIRED WATER HEATERS COF models provide thermal efficiencies up to 82%. Oil-Fired Small-Volume Models Our COF-199 and larger models have an optional two-stage pump for use with below-grade oil storage tanks. Features include two hand hole clean outs for easy servicing. Small-Volume COF Quality Features F or small to medium-sized applications U L listed oil burner n 1 80°F adjustable thermostat n S ingle-stage oil pump for simple, efficient operation n S olenoid oil valve (standard on COF-455, COF-700) n 3 /4˝ drain valve n 1 /8 HP motor n F actory-installed ASME-rated T&P valve properly sized for each model n T wo hand hole clean outs (COF-385 and larger, and ASME models) for easy maintenance n B arometric draft regulator provided for proper operation, ensures correct flow in the vent n F oam insulation n Intermittent ignition n Anodic protection for longer tank life n F lame observation port n G lass-lined tank with 160 psi maximum working pressure n Professional start-up provided n n 3-Year Limited Tank/1-Year Limited Parts Warranty n F actory start-up is required to validate warranty Options T wo-stage pump for use with underground oil storage tanks n O il solenoid safety valve n A SME construction available on models COF-315 and larger n MODEL CAPACITY USG (L) INPUT* BTU/h MAXIMUM CERTIFIED ALTITUDE FT (M) COF-199 86 (326) 199,000 2,000 (610) 191 (723) COF-245 86 (326) 245,000 2,000 (610) 235 (890) COF-315(A) 84 (318) 315,000 2,000 (610) 302 (1,143) COF-385(A) 75 (284) 385,000 2,000 (610) COF-455(A) 75 (284) 455,000 2,000 (610) COF-700(A) 69 (261) 700,000 2,000 (610) RECOVERY 100°F (56°C) TEMP. RISE HLW APPROX. SHIPPING WEIGHT LB (KG) STD ASME DIAMETER IN (CM) DEPTH IN (CM) 74 1/2 (189) 27 3/4 (70) 36 ¾ (93) 553 (251) 74 1/2 (189) 27 3/4 (70) 36 ¾ (93) 554 (251) - 74 1/2 (189) 27 3/4 (70) 36 ¾ (93) 554 (251) 657 (298) 369 (1,397) 73 3/4 (187) 27 3/4 (70) 36 ¾ (93) 624 (283) 742 (337) 436 (1,650) 73 3/4 (187) 27 3/4 (70) 36 ¾ (93) 700 (318) 747 (339) 671 (2,540) 73 3/4 (187) 27 3/4 (70) 36 ¾ (93) 739 (335) 822 (373) GPH (LPH) HEIGHT IN (CM) LOW LEAD CONTENT - (A) -Available in ASME models *Based on No. 2 fuel oil 17 OIL-FIRED WATER HEATERS Heavy-Duty Oil-Fired COF/COBT Models Large Volume High Output Oil and Dual Fuel Water Heaters. COF models offer oil-fuel burners for use with No. 1 or 2 oil. COBT models feature combination gas/oil powered burners for the versatility of operating with natural gas/propane and No. 1 or 2 oil. COF/COBT models include some of the largest and most powerful A. O. Smith tank-type water heating systems available – with storage/input options up to 600 gallons/2,500,000 BTU/h and recoveries as high as 2,424 gallons/hour at 100°F rise. All models feature fully automatic controls with safety shut off, two thermostats (upper and lower) for accurate temperature control, and ASME tank construction. COF (Oil-Fired Models) Use either No. 1 or 2 fuel oil 3,450 rpm motor n Multi-annular fuel containment combustor head n Oil ignition transformer n Integral 2-stage fuel unit and oil safety valve n n COBT (Combination Gas/Oil-Fired Models) Use either natural gas or propane and No. 1 or 2 fuel oil 3,450 rpm motor n Multi-annular fuel containment combustor head n Gas/electric pilot and gas ignition transformer n Pilot and main pressure regulators n Air safety switch n Manual fuel selector switch n Integral 2-stage fuel unit n n Fully Automatic Controls with Safety Shut Off H igh temperature limit control (manual reset) A SME-rated T&P valve n H inged door control (COBT models) compartment for easy access n U pper and lower thermostats for accurate temperature control n HLW n Glass-Lined Tank E xclusive corrosion protection with glass-lining on all interior surfaces n E quipped with multiple anode rods for additional corrosion protection n Heavy-Duty Jacket H eavy gauge steel jacket with baked powder-coated finish for durability n T wo 3˝ hand hole inspection openings n Maximum Hydrostatic Working Pressure n 160 psi for all models Professional Start-Up Service n 18 A ssures most efficient combustion and safe initial installation COF/COBT Options F actory mutual approved control arrangement H igh or low water pressure switch n 1 80°F water service thermostats n A SME-rated T&P valve n M odular graphic burner systems management on heaters with 270,000 BTU/h input and greater n n Flame Inspection Port Opening Mounted on Rugged Channel Iron Skids ASME Stamping Codes and Standards Low Water Cut Off n 3-Year Limited Tank/1-Year Limited Parts Warranty n OIL-FIRED WATER HEATERS Two Layers of High Temperature Ceramic Fiber Insulation in Combustion Chamber A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Factory start-up is required to validate warranty MODEL CAPACITY USG (L) INPUT BTU/h OIL FIRING RATE GPH (LPH) FIRST HOUR RATING GPH (LPH) RECOVERY 100°F (56°C) TEMP. RISE COF-150-140 163 (617) 140,000 1 (3.8) 241 (912) 136 (515) COF-150-199 163 (617) 199,000 1.4 (5.3) 298 (1,128) 193 (731) COF-150-255 163 (617) 255,000 1.8 (6.8) 352 (1,332) 247 (935) COF-150-270 163 (617) 270,000 1.9 (7.2) 367 (1,389) COBT-150-350 150 (568) 350,000 2.2 (8.3) COF/COBT-150-400 151 (572) 400,000 COF/COBT-150-540 151 (572) COF/COBT-150-720 COF/COBT-200-300* GPH (LPH) COBT MOTOR HP 1 Ø 120V COF MOTOR HP 1 Ø 120V VENT DIAMETER (IN) HEIGHT IN (CM) DIAMETER IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 5 82 ¼ (209) 36 1/2 (93) 47 (119) 1,292 (586) 6 82 ¼ (209) 36 1/2 (93) 47 (119) 1,292 (586) 6 82 ¼ (209) 36 1/2 (93) 47 (119) 1,292 (586) 262 (992) 6 82 ¼ (209) 36 1/2 (93) 57 ½ (146) 1,397 (634) 444 (1,681) 339 (1,283) 7 82 ¼ (209) 36 1/2 (93) 57 ½ (146) 1,397 (634) 2.8 (10.6) 452 (1,711) 387 (1,465) 7 82 ¼ (209) 36 1/2 (93) 57 ½ (146) 1,397 (634) 540,000 3.8 (14.4) 629 (2,381) 524 (1,984) 8 82 ¼ (209) 36 1/2 (93) 57 ½ (146) 1,505 (683) 145 (549) 720,000 5.1 (19.3) 803 (3040) 698 (2,642) 10 82 ¼ (209) 36 1/2 (93) 57 ½ (146) 1,510 (685) 221 (837) 300,000 2.1 (7.9) 446 (1,688) 291 (1,102) 6 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,098 (952) 1/7 HP 4.4 Amp 1/3 HP 5.5 Amp 1/4 HP 4.6 Amp COF/COBT-200-600 221 (837) 600,000 4.2 (15.9) 737 (2,790) 582 (2,203) 8 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,098 (952) COF/COBT-200-800 221 (837) 800,000 5.7 (21.6) 931 (3,524) 776 (2,937) 10 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,103 (954) COF/COBT-200-1000 201 (761) 1,000,000 7.1 (26.9) 1,111 (4,206) 970 (3,672) COF/COBT-200-1250 201 (761) 1,250,000 8.9 (33.7) 1,353 (5,122) 1,212 (4,588) COF/COBT-200-1500 201 (761) 1,500,000 10.7 (40.5) 1,560 (5,905) 1,455 (5,508) COF/COBT-300-300* 300 (1,136) 300,000 2.1 (7.9) 501 (1,896) 291 (1,102) COF/COBT-300-600 300 (1,136) 600,000 4.2 (15.9) 792 (2,998) 582 (2,203) COF/COBT-300-800 300 (1,136) 800,000 5.7 (21.6) 986 (3,732) 776 (2,937) COF/COBT-300-1000 300 (1,136) 1,000,000 7.1 (26.9) 1,180 (4,467) 970 (3,672) COF/COBT-300-1250 300 (1,136) 1,250,000 8.9 (33.7) 1,422 (5,383) 1,212 (4,588) COF/COBT-300-1500 300 (1,136) 1,500,000 10.7 (40.5) 1,665 (6,303) 1,455 (5,508) COF/COBT-400-600 411 (1,556) 600,000 4.2 (15.9) 870 (3,293) 582 (2,203) COF/COBT-400-800 411 (1,556) 800,000 5.7 (21.6) 1,064 (4,028) 776 (2,937) COF/COBT-400-1000 411 (1,556) 1,000,000 7.1 (26.9) 1,268 (4,800) 970 (3,672) COF/COBT-400-1250 411 (1,556) 1,250,000 8.9 (33.7) 1,500 (5,678) 1,212 (4,588) COF/COBT-400-1500 397 (1,503) 1,500,000 10.7 (40.5) 1,733 (6,560) 1,455 (5,508) COF/COBT-400-1750 397 (1,503) 1,750,000 12.5 (47.3) 1,975 (7,476) 1,697 (6,424) COF/COBT-400-2000 397 (1,503) 2,000,000 14.2 (53.8) 2,217 (8,392) 1,939 (7,340) COF/COBT-500-2250 495 (1,874) 2,250,000 16.0 (60.6) 2,445 (9,255) 2,182 (8,260) COF/COBT-500-2500 495 (1,874) 2,500,000 17.8 (67.4) 2,687 (10,171) 2,424 (9,176) COF/COBT-600-720 594 (2,249) 720,000 5.1 (19.3) 1,114 (4,217) 698 (2,642) COF/COBT-600-1000 594 (2,249) 1,000,000 7.1 (26.9) 1,386 (5,247) 970 (3,672) COF/COBT-600-1250 594 (2,249) 1,250,000 8.9 (33.7) 1,627 (6,159) 1,212 (4,588) COF/COBT-600-1500 594 (2,249) 1,500,000 10.7 (40.5) 1,871 (7,083) 1,455 (5,508) COF/COBT-600-1750 594 (2,249) 1,750,000 12.5 (47.3) 2,116 (8,010) 1,697 (6,424) COF/COBT-600-2000 594 (2,249) 2,000,000 14.2 (53.8) 2,355 (8,915) 1,939 (7,340) COF/COBT-600-2250 575 (2,177) 2,250,000 16.0 (60.6) 2,585 (9,785) 2,182 (8,260) COF/COBT-600-2500 575 (2,177) 2,500,000 17.8 (67.4) 2,827 (10,701) 2,424 (9,176) 1/3 HP 5.5 Amp 3/4 HP 10.2 Amp 1/4 HP 4.6 Amp 1/3 HP 5.5 Amp 1/3 HP 5.5 Amp 3/4 HP 10.2 Amp 1/4 HP 4.6 Amp 1/3 HP 5.5 Amp 1/3 HP 5.5 Amp 3/4 HP 10.2 Amp 1 HP 16 Amp 1/3 HP 5.5 Amp 1/4 HP 4.6 Amp 1/3 HP 5.5 Amp 3/4 HP 10.2 Amp 1 HP 16 Amp 10 84 ½ (215) 44 ¾ (114) 66 ½ (169) 2,103 (954) 12 84 ¾ (215) 44 ¾ (114) 66 ½ (169) 2,467 (1,119) 12 84 ¾ (215) 44 ¾ (114) 81 ½ (207) 2,675 (1,213) 6 92 (234) 44 ¾ (114) 66 ½ (169) 2,150 (975) 8 92 (234) 44 ¾ (114) 66 ½ (169) 2,150 (975) 10 92 (234) 44 ¾ (114) 66 ½ (169) 2,308 (1,047) 10 92 (234) 44 ¾ (114) 66 ½ (169) 2,308 (1,047) 12 92 (234) 44 ¾ (114) 66 ½ (169) 2,584 (1,172) 12 92 (234) 44 ¾ (114) 81 ½ (207) 2,774 (1,258) 8 89 (226) 55 (140) 76 ½ (194) 3,207 (1,455) 10 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) 10 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) 12 89 (226) 55 (140) 76 ½ (194) 3,212 (1,457) 12 89 (226) 55 (140) 91 ½ (232) 3,402 (1,543) 14 89 (226) 55 (140) 91 ½ (232) 3,528 (1,600) 14 96 ¼ (244) 55 (140) 91 ½ (232) 3,669 (1,664) 16 108 (274) 55 (140) 91 ½ (232) 4,277 (1,940) 16 108 (274) 55 (140) 91 ½ (232) 4,419 (2,004) 10 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) 10 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) 12 114 (290) 55 (140) 76 ½ (194) 3,667 (1,663) 12 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) 14 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) 14 114 (290) 55 (140) 91 ½ (232) 3,837 (1,740) 16 114 (290) 55 (140) 91 ½ (232) 4,477 (2,031) 16 114 (290) 55 (140) 91 ½ (232) 4,619 (2,095) *COBT models are 350,000 BTU Field certification required on all COF/COBT installations in Canada 19 ELECTRIC WATER HEATERS DEN/DEL Electric Dura-Power™ Models The Dura-Power DEN (standard upright) and DEL (lowboy) series are available with tank capacities from 6 through 119 gallons. They can be installed for non-simultaneous and single-element operation (maximum input up to 6 kW ) or for simultaneous dual-element operation (maximum input up to 12 kW). They are designed for use as recovery heaters for light-duty hot water supply service. Zinc-Plated Copper Sheath Heating Elements Standard Factory-Wired Controls emperature control adjustable from T 110°F to 170°F on single- element or 120°F to 180°F on dual element models n M anual reset high temperature cut off per element (dual element models) n F actory-wired for non-simultaneous operation; easily converted to simultaneous operation (three-phase models only) n M edium-watt density design disperses element temperature over larger surface contact area to minimize scale build-up, maximize efficiency and prolong element life n E lement options from 1.5 kW to 6 kW (non-simultaneous or simultaneous operation), recoveries from 6 GPH to 49 GPH at 100°F rise n Glass-Lined Tank P rovides long-lasting protection against corrosion n E quipped with anode rod for additional corrosion protection n Standard Voltages for Easy Installation 1 20V, 277V single-phase, and 208V, 240V and 480V unbalanced three-phase delta n E asily converted to single-phase at terminal block (except for 208V with 6000W elements) n S ingle-element heater, single-phase only (see chart for dual-element options) n n 208V 240V 277V 480V Yes Yes Yes Yes* - Yes Yes Yes Yes Yes Yes Yes Yest (Yes) Yes Yes Yes Yes Yes Yes Yes Yes Yes (Yes) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6 gallon model not available above 3kW 6/10/15/20 gallon models all A6 circuit (2 wire) only * On dual element models, only available for non-simultaneous operation † On dual element models, only available for 3 phase simultaneous operation () Only available on single element models 20 Codes and Standards n S upplied on 208V, 240V and 480V models 120V 1 50 psi for all models A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 3-Year Limited Tank/1-Year Limited Parts Warranty ELEMENT AVAILABILITY 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 n Factory-Installed Terminal Block LOW LEAD CONTENT INPUT (W) Maximum Hydrostatic Working Pressure For complete information on available configurations, consult spec sheet. MAXIMUM KILOWATTS HEIGHT IN (CM) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) MODEL CAPACITY USG (L) DEL-6S 6 (23) 3 15 1/2 (39) 14 1/4 (36) DEL-10S 10 (37) 6 18 /4 (46) 18 (46) 54 (24) DEL-15S 13 (49) 6 26 (66) 18 (46) 58 (26) DEL-20S 19 (74) 6 22 1/4 (57) 21 3/4 (55) 73 (33) SINGLE ELEMENT POINT-OF-USE MODELS 1 35 (16) DUAL ELEMENT MODELS* DEL-30D 29 (111) 12 30 7/8 (78) 21 3/4 (55) 100 (45) DEL-40D 38 (145) 12 32 1/4 (82) 24 (61) 125 (57) DEL-50D 46 (175) 12 32 1/4 (82) 26 1/2 (67) 166 (75) DEN-30 28 (107) 12 34 1/2 (88) 20 1/2 (52) 98 (44) DEN-40 37 (143) 12 45 1/8 (115) 20 1/2 (52) 113 (51) DEN-52 46 (175) 12 54 7/8 (139) 20 1/2 (52) 131 (59) DEN-66 62 (237) 12 60 3/4 (154) 21 3/4 (55) 176 (80) DEN-80 75 (284) 12 59 3/8 (151) 24 (61) 211 (96) DEN-120 113 (428) 12 62 7/16 (159) 29 3/8 (75) 326 (148) *Pre-wired for unbalanced three-phase only, non-simultaneous operation of elements standard. Can be re-wired for single phase operation. ELECTRIC WATER HEATERS DRE/DVE Electric Gold and Gold Xi™ Series Gold and Gold Xi DRE/DVE series available with 50, 80, and 119 gallon storage tanks, with input choices ranging from 6 kW to 54 kW. They can be used as recovery heaters for hot water supply service or as boosters for supplying sanitizing rinse water for dish washing. Goldenrod® 24k gold-plated Elements Standard n Brass n S uperior scaling resistance, resulting in long term efficiency and damage protection n E lement sizes from 2 kW to 6 kW in 3, 6 or 9 element configurations provide input options from 6 kW to 54 kW, recoveries from 25 GPH to 221 GPH at 100°F rise n Internal Fusing for System Protection n D RE Gold models have surface mounted thermostats with temperature control adjustable 120° to 181°F n M anual reset high temperature cut off n Advanced Electronic Controls S afeguards elements and contactors from short circuits, overloading and line surges iCOMM™ compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information n C onnect to an existing building management system via BACnet or MODBUS with optional ICC gateway n P lain English text and animated icons n D isplays detailed operational and diagnostic information n F ault or alert messages appear if an operational issue occurs n L ast 9 fault and alert messages saved with time stamp n S ingle-phase and three-phase delta n F ield-convertible voltages threephase to single-phase (and vice versa) except for 208V/54 kW n 2 77V single-phase also available n Factory-Installed Terminal Block P rovide electrical service to heater and connect to block Heavy-Duty Magnetic Contactors (DVE Models Only) n DRE Gold Model Controls DVE Gold Xi Model Features Standard 208, 240 and 480V Options for Easy Installation n drain valve C SA Certified and ASME rated temperature and pressure relief valve U L-rated 100,000 cycles Other Standard DRE/DVE Features T wo anode rods for maximum corrosion protection n S implified circuitry, colour-coded for ease of service n B onderized undercoated baked enamel finished cabinets n B anks of heating elements (3 elements per bank) are energized according to adjustable (1˚ to 20˚F) differential set points for each bank. Helps reduce current surge and provides accurate water temperature control n L inear sequencing - first bank on is last bank off n H elps reduce current surge/spikes and avoid peak demand charges n H elps reduce operating costs during low load conditions n M anual reset high temperature cut off n Compliance n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 3-Year Limited Tank/1-Year Limited Parts Warranty Economy Mode Operation C ontrol system automatically lowers the operating set point by a programmed value during user-defined time periods n H elps reduce operating costs during unoccupied or low demand periods n Precise Temperature Regulation n Immersion thermostat allows for more accurate temperature adjustment from 90° to 190°F APPROX. SHIPPING WEIGHT LB (KG) MODEL CAPACITY USG (L) MAXIMUM KILOWATTS HEIGHT IN (CM) DIAMETER IN (CM) STD ASME DVE/DRE-52 50 (189) 54 55 3/4 (142) 21 3/4 (55) 265 (120) 315 (143) DVE/DRE-80 80 (303) 54 60 1/4 (153) 25 1/2 (65) 280 (127) 330 (150) DVE/DRE-120 119 (450) 54 62 1/4 (158) 29 1/2 (75) 390 (177) 440 (200) DVE Model DRE Model LOW LEAD CONTENT (DVE Models Only) HLW (Optional) 21 ELECTRIC WATER HEATERS Heavy-Duty Custom Xi™ Series Electric DSE Models The heavy-duty Custom Xi DSE series is Incoloy Sheath Heating Elements available with storage capacities from 5 Standard n I ndustrial-grade incoloy sheathed heating to 119 gallons. All tanks feature ASME elements are designed for rugged longtank construction. With input choices as lasting commercial service, and can withstand sheath temperatures up to high as 90 kW on 50 through 119 gallon 1500°F models, the DSE Custom Xi series can be nE ach heating element has three separate used for maximum-demand hot water heating loops, which provides more supply service or as boosters for supplying heating surface, lower watt density and maximum recovery efficiency sanitizing rinse water for dish washing. Progressive Sequencing nF irst heating element on is first heating element off nF irst heating element energized is rotated with each successive heating cycle on models with multiple heating elements n E vens out wear between heating elements n H elps reduce current surge/spikes and avoid peak demand charges nP re-wired leads provide excellent protection against oxidation and scaling n I nput options from 3 kW to 90 kW, recoveries from 12 GPH to 369 GPH at 100°F rise Standard Voltages for Easy Installation n2 08, 240 and 480V single-phase and threephase nS ingle-phase 208V and 240V are fieldconvertible to three-phase nA ll 208V and 240V at 24 kW and below are supplied as phase-convertible units (singleto three-phase and vice versa) n2 77V single-phase also available (Contact A. O. Smith for 120V circuit availability) n3 80, 415, 575 and 600 international voltages also available (check with A. O. Smith) Factory-Installed Terminal Block nT o accept copper or aluminum leads (on units with more than one contactor) Optional Goldenrod® 24-karat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500ºF. compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information nP lain English text and animated icons nC onnect to an existing building management system via BACnet or MODBUS with optional ICC gateway nD isplays detailed operational and diagnostic information nF ault or alert messages appear if an operational issue occurs nL ast 9 fault and alert messages saved with time stamp MODEL 22 CAPACITY USG (L) system automatically lowers the operating set point by a programmed value during user-defined time periods n H elps reduce operating costs during unoccupied or low demand periods Precise Temperature Regulation n A dvanced electronic control provides precise ±1°F temperature control that is ideal for industrial and food service applications where exact temperatures of hot water are needed nO perating set point is adjustable from 90° to 190°F n Manual reset high temperature cut off Heavy-Duty Magnetic Contactors Power Circuit Fusing for System Protection CSA Certified and ASME Rated T&P Relief Valve n i COMM™ LOW LEAD CONTENT nC ontrol PermaGlas® Ultra Coat™ Glass Lining with ASME Tank Construction Advanced Electronic Controls HLW Economy Mode Operation Compliance n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Brass Drain Valve 3-Year Limited Tank/1-Year Limited Parts Warranty MAXIMUM INPUT (kW) IMMERSION HEATERS HEIGHT IN (CM) DIAMETER IN (CM) APPROX. SHIPPING WEIGHT LB (KG) DSE-5 5 (19) 3 1 20 ¼ (51) 16 1/4 (41) 82 (37) DSE-10 10 (38) 6 1 26 ¼ (67) 18 3/4 (48) 116 (53) 145 (66) DSE-20 20 (76) 18 2 27 1/4 (69) 20 1/2 (52) DSE-30 30 (114) 24 2 35 3/4 (91) 20 1/2 (52) 150 (68) DSE-40 40 (151) 36 2 45 3/4 (116) 20 1/2 (52) 190 (86) DSE-50 50 (189) 90 5 54 3/4 (139) 20 1/2 (52) 221 (100) DSE-65 65 (246) 90 5 54 (137) 26 1/2 (67) 280 (127) DSE-80 80 (303) 90 5 52 ¼ (132) 28 (71) 285 (129) DSE-100 100 (379) 90 5 60 ½ (154) 28 (71) 354 (161) DSE-120 120 (450) 90 5 65 ½ (166) 30 (76) 420 (191) ELECTRIC WATER HEATERS Heavy-Duty CMC/SU Booster Electric Dura-Power™ Models The Dura-Power commercial electric water heaters are designed to boost the water temperatures for applications such as commercial dishwashers, which require very high temperature sanitizing rinse...typically 180°F. Both 5-gallon countermount CMC models and 20-gallon SU models are available with inputs up to 54 kW. All models are also available with an optional stainless steel tank, for use with deionized water. Incoloy-Sheath Heating Elements Standard Industrial-grade incoloy sheathed heating elements are designed for rugged long-lasting commercial service and can withstand sheath temperatures up to 1500°F n Each heating element has three separate heating loops, which provides more heating surface, lower watt density and maximum recovery efficiency n Pre-wired leads provide excellent protection against oxidation and scaling n Input options from 6 kW to 54 kW and recoveries from 25 GPH to 221 GPH at 100°F rise n Deionized models equipped with stainless steel standard elements n A. O. Smith Goldenrod® Elements Optional atent pending 24K gold-plated P sheath plus medium watt density ensures even longer element life n Higher resistance to scale build up compared to incoloy elements n Three-year warranty against failure due to lime scale build-up n Not available on deionized models n Standard Voltages for Easy Installation S ingle-phase and three-phase Single-phase 208V and 240V are field-convertible to three-phase n CMC models only, 208V and 240V at 24 kW and below are supplied as phase-convertible units (single- to three-phase and vice versa) n 277V single-phase also available (contact A. O. Smith for 120V circuit availability) Immersion Thermostat for Efficient Control lose differential, immersionC type thermostat for superbly accurate temperature control n Adjustable from 140°F to 185°F n Manual reset high temperature cut off n Power Circuit Fusing for System Protection n Safeguards elements and contactors from short circuits, overloading and line surges Heavy-Duty Magnetic Contactors n UL-rated 100,000 cycles Factory-Wired 120V Circuit Controls 20V control circuit powered 1 by fused transformer n Eliminates need for 120V service connection n Compliance n Optional Goldenrod® 24-karat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500ºF. 3-Year Limited Tank/1-Year Limited Parts Warranty NO. OF IMMERSION HEATERS MODEL CAPACITY USG (L) CMC-6 through 18 5 (19) 1 CMC-20 through 54 5 (19) 2* n n HLW models meet the thermal All efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 APPROX. SHIPPING WEIGHT LB (KG) INLET & OUTLET (IN) HEIGHT IN (CM) 3 /4 13 3/4 (35) 13 (33) 23 ½ (60) 80 (36) 3 /4 12 (31) 18 (46) 23 ½ (60) 96 (44) WIDTH IN (CM) DEPTH IN (CM) SU-6 through 18 20 (76) 1 3 /4 25 (64) 22 1/4 (57) 23 (58) 200 (91) SU-20 through 54 20 (76) 2* 3 /4 25 (64) 22 1/4 (57) 23 (58) 200 (91) *CMC-54 and SU-54 have three immersion heaters 23 ELECTRIC WATER HEATERS Heavy-Duty Premium Electric DVE/DHE Dura-Power™ Xi Models Dura-Power commercial electric water heaters are built to the same high quality standards as our gas models. These are the largest commercial electrics we manufacture. Ideal for use as recovery heaters for all types of large commercial and industrial applications or for large process potable hot water requirements. They can be customized to meet any special application with the large selection of available options. Advanced Electronic Control n A. O. Smith’s proprietary electronic water heater control provides precise ±1°F temperature control, that is ideal for industrial and food service applications where exact temperatures of hot water are needed. · Animated icons display detailed operational and diagnostic information, and plain text fault or alert messages appear if an operational issue occurs · Low water cut off is factory standard and uses a remote electronic immersion type probe to prevent energizing of the elements in the event of low water condition and eliminates accidental dry firing HLW LOW LEAD CONTENT Optional Goldenrod® 24-karat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500ºF. · Progressive modulating sizes the input of available elements to match current load conditions and rotates and lead lags element loads to provide long life and equal wear · Economy mode operation automatically lowers the operating set point by a programmed value during user defined time periods using a seven-day clock that may be programmed for night set back and/or weekend shutdown to reduce operating cost and save money · iCOMM™ compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information. · B uilding management system compatible via BACnet or MODBUS with optional ICC gateway PermaGlas® Ultra Coat™ Glass Lining nE xclusive process provides superior protection against corrosion in varying water conditions ASME Code Construction nA ll 24 models are constructed to the requirements of ASME and are available in 100, 125, 150 and 160 psi working pressures (125 psi working pressure is standard) Incoloy Immersion Heaters n Heavy-duty medium watt density elements (three immersion heater) have incoloy sheathing providing excellent protection against oxidation and scaling with input ranges from 15 kW to 3000 kW Power Circuit Fusing for System Protection Compliance n ll models meet the thermal A efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Magnetic Contactor(s) nH eavy cycles duty UL rated for 100,000 Other Standard Features nC olour-coded circuitry for easier servicing nA node rods for maximum corrosion protection nS tandard voltages include 208, 240, 480, 600 volt single or three-phase nF or other voltages consult A. O. Smith n F actory-installed terminal block(s) nC abinet has baked enamel finish nP re-wired element terminal leads nT emperature and pressure relief valve nT anks have a channel skid base n A 4" x 6" hand hole is furnished on 500, 600 and 700 gallon models and a 11" x 15" manhole on 800 gallon and larger sizes Optional Dual-Energy Source Capability nP rovides emergency back up energy source or winter/summer boiler operation nC an be specified with optional water to water or steam to water heat exchangers n B oth single and double wall heat exchangers are available nC omplete control packages can be factory installed for hook up and run capability 3-Year Limited Tank/1-Year Limited Parts Warranty n3 -1/2” DIAL-TYPE TEMPERATURE GAUGE – Factory-installed. n1 1” x 15” MANHOLE – Available as option on tanks 700 gallons down to 30" tank diameter. n TANK LININGS CEMENT – A special formulation of cement providing excellent corrosion protection. Available on 200-gallon and larger tanks. EPOXY – A solventless two component epoxy lining applied to a minimum ten-mil (.010”) dry thickness. Available on 200-gallon and larger tanks. n GOLDENROD® ELEMENTS – Available with optional Goldenrod elements - All DVE/DHE models are available with the Goldenrod 24K gold plated elements (patent pending). Goldenrod elements provide long-life and five times the scaling resistance of standard incoloy elements. Goldenrod elements carry a three-year warranty against failure due to scale buildup. n STAINLESS STEEL VESSELS – Are available for deionized water. Built with stainless steel under rules of Section IV of the ASME Boiler and Pressure Vessel Code for operation on deionized water having a minimum specific resistivity of 10 megohm/cm. n 150 OR 160 PSI WORKING PRESSURE – Must be specified at time of order. Other Optional Features n TEMPERATURE AND PRESSURE RELIEF VALVES – For working pressures other than standard consult factory. n HORIZONTAL OR VERTICAL – See specifications, most gallon capacities may be obtained in vertical or horizontal construction. n CIRCULATING PUMP PACKAGE – Circulating pump and piping sized to turn over entire storage capacity of tank once each hour. Recommended to optimize available water at temperature in horizontal tanks particularly where low draw conditions are anticipated. n OPTIONAL INTERNATIONAL VOLTAGES – 380 and 415 volts three-phase. n 3-1/2” DIAL-TYPE PRESSURE GAUGE – Factory-installed. Control Options n COPPER TUBE TANK HEATER – Double wall copper tube tank heaters are designed for heating potable water with both potable or non-potable liquids or steam, and are specifically engineered for installation in models DVE and DHE for dual-energy applications. Tank heaters have a positive fail-safe means of leak detection in the event of either tube failure to prevent mixture of heating medium and potable water. Single wall heat exchangers are also available. n TERMINAL BLOCKS – Allows for remote connection to building demand limiter or other functions. n AUTOMATIC RESET HIGH LIMIT – A control that in the event of high temperature, interrupts power, de-energizing elements, automatic reset. (Standard with modulating step control). n INDICATING LIGHTS – Denotes heating stage(s) in operation. Up to one light per contactor is available. n OVERRIDE SWITCHES – A simple means of load control allows all or part of unit input to be controlled manually. Up to one switch per contactor is available. n SAFETY DOOR INTERLOCK – Prevents opening of control panel door when heater power supply is on. NOTE: Once door is opened heater may be energized if necessary for service diagnosis. n SHUNT TRIP CIRCUIT BREAKER – A safety device (circuit breaker) which disconnects power to heater in the event of over-current, high temperature or low water level, breaker must be manually reset. n CIRCUIT BREAKER – A safety device which disconnects power to the heater in the event of overcurrent. VERTICAL ELECTRIC STORAGE HEATERS HORIZONTAL ELECTRIC STORAGE HEATERS MODEL* CAPACITY USG (L) MAX INPUT (kW) ELECTRIC WATER HEATERS Options HEIGHT IN (CM) WIDTH IN (CM) DEPTH IN (CM) MODEL* CAPACITY USG (L) MAX INPUT (kW) HEIGHT IN (CM) WIDTH IN (CM) DEPTH IN (CM) 37 (94) DHE-200 200 (757) 180 38 1/2 (98) 77 (196) 36 (91) DVE-140 140 (530) 150 83 ½ (212) 30 (76) DHE-250 250 (946) 240 38 1/2 (98) 91 (231) 36 (91) DVE-150 150 (568) 150 83 1/2 (212) 30 (76) 37 (94) DHE-300 300 (1,136) 300 44 1/2 (113) 81 (206) 42 (107) DVE-150L 150 (568) 150 59 1/2 (151) 36 (91) 43 (109) DHE-350 350 (1,325) 330 44 1/2 (113) 93 (236) 42 (107) DVE-200 200 (757) 180 79 1/2 (202) 36 (91) 43 (109) DHE-400 400 (1,514) 390 44 1/2 (113) 100 (254) 42 (107) DVE-250 250 (946) 240 93 (236) 36 (91) 43 (109) DHE-500 500 (1,893) 480 51 (130) 94 (239) 48 (122) DVE-300 300 (1,136) 300 83 1/2 (212) 42 (107) 49 (124) DHE-600 600 (2,271) 600 51 (130) 109 (277) 48 (122) DVE-350 350 (1,325) 330 95 1/2 (243) 42 (107) 49 (124) DHE-700 700 (2,650) 690 51 (130) 121 (307) 48 (122) DVE-400 400 (1,514) 390 102 1/2 (206) 42 (107) 49 (124) DHE-800 800 (3,028) 780 57 (145) 111 (282) 54 (137) DVE-500 500 (1,893) 480 97 (246) 48 (122) 55 (140) DHE-1000 1,000 (3,785) 990 61 (155) 111 (282) 60 (152) DVE-600 600 (2,271) 600 112 (284) 48 (122) 55 (140) DHE-1250 1,250 (4,732) 1,200 61 (155) 138 (351) 60 (152) DVE-700 700 (2,650) 690 124 (315) 48 (122) 55 (140) DHE-1500 1,500 (5,678) 1,500 61 (155) 150 (381) 60 (152) DVE-800 800 (3,028) 780 116 (295) 56 (142) 61 (155) DHE-2000 2,000 (7,571) 1,980 70 (178) 177 (450) 66 (168) DVE-1000 1,000 (3,785) 990 116 (295) 60 (152) 67 (170) DHE-3000 3,000 (11,356) 3,000 76 (193) 211 (536) 72 (183) DVE-1250 1,250 (4,732) 1,200 143 (363) 60 (152) 67 (170) DHE-5000 5,000 (18,927) 3,000 82 (208) 296 (752) 78 (198) DVE-1500 1,500 (5,678) 1,500 155 (394) 60 (152) 67 (170) DHE-7500 7,500 (28,391) 3,000 94 (239) 317 (805) 90 (229) DVE-2000 2,000 (7,571) 1,980 183 (465) 66 (168) 73 (185) DHE-10,000 10,000 (37,854) 3,000 106 (269) 345 (876) 102 (259) DVE-3000 3,000 (11,356) 3,000 217 (551) 72 (183) 79 (201) DVE-5000 5,000 (18,927) 3,000 309 (785) 78 (198) 85 (216) DVE-7500 7,500 (28,391) 3,000 330 (838) 90 (229) 97 (246) DVE-10,000 10,000 (37,854) 3,000 358 (909) 102 (259) 109 (277) *Complete model number includes the desired kW at the end. Minimum installation clearances required: 30˝ (76 cm) from front, 12˝ (30 cm) from top and 24˝ (61 cm) from right side. *Complete model number includes the desired kW at the end. Minimum installation clearances required: 30˝ (76 cm) from front, 12˝ (30 cm) from top and 24˝ (61 cm) from right side. Field certification required on all DVE/DHE installations in Canada. 25 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS XWH Model Circulating Water Heaters The ENERGY STAR® qualified A. O. Smith high efficiency condensing XP Water Heater utilizes a state-of-the-art heat exchanger and control technology to provide large volumes of hot water for demanding commercial and industrial potable hot water applications. The all stainless steel water tube heat exchanger construction allows the XP Water Heater to operate in a continuous condensing mode while maximizing longevity and delivering thermal efficiencies as high as 99% when operating in low temperature applications. A unique multi-burner design is control sequenced and modulated to produce turndown rates of up to 20:1. Precise temperature control and accurate load matching produce smooth system operation and eliminates wasteful short cycling and temperature overshooting. Advanced Multi-Burner, Low NOx Combustion Technology n n V enturi-mixing gas/air ratio system - works with variable speed blower to precisely mix gas and air throughout firing range F ully modulating capability prevents energy-stealing short cycling and provides smooth system operation with higher overall system efficiencies Advanced Sola Control n n n n n HLW L arge touch screen user interface F actory standard with MODBUS protocol connections T he latest in energy saving algorithms Includes remote tank temperature control to adjust tank temperature at the water heater - modulates the water heater to maintain tank set point temperature within ±1°F W ater heater output control features 20:1 turndown ratio on models 2 million BTU/h and up, 10:1 turndown ratio on models 1.7 million BTU/h and down All-Bronze Factory-Mounted Pump(s) n n n Integrally mounted, wired, and controlled by the water heater control F actory-sized for proper flow between water heater and storage tank A llows 50 equivalent feet of piping between water heater and tank Multi-Pass/Multi-Burner Condensing Stainless Steel Heat Exchanger n n n n n 26 U tilizes leading-edge multi-pass water tube heat exchanger to maximize heat transfer D esigned for fully condensing operation throughout the heating range A ll heating surfaces are 316L stainless steel to provide a long and trouble-free service life S aves both fuel and operating cost with every heating cycle Impervious to thermal shock Direct Vent Flexibility n n n n D irect vent up to 100 equivalent feet (30 meters) of pipe Sidewall or vertical L ower installation cost with ULC S636 approved PVC/CPVC venting material – uses CPVC for first 10 feet (3 meters) and PVC thereafter A pproved for use with UL approved AL29-4C® stainless steel venting materials CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS XWH Model Circulating Water Heaters A unique multi-burner design. Factory Start-Up Included n R equired for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certified start-up Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Up to 96% Thermal Efficiency (AHRI Certified) 5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty n F or complete information, consult written warranty or contact A. O. Smith Other XP Features: n n n M eets ASME CSD-1/GE gap codes – factory standard C SA certified to the ANSI Z21.10.3-CSA 4.3 water heater standard n D irect spark ignition n F actory-installed electrical disconnect H oneywell sola control with colour touch screen LCD display n A SME 160 psi working pressure n A SME rated pressure relief valve – 125 psi · Inlet/outlet and remote tank temperature display XP Options: · Logs faults, run time, cycles · Redundant flow and low water protection - factory installed LWCO and flow switch(s) n · Redundant ignition controls – should one burner fail remaining burners continue to heat n n n A SME HLW stamped heat exchanger(s) C ondensate neutralization kit V ent termination kits S kid mounted systems · Alarm buzzer RECOVERY CAPACITIES MODEL INPUT BTU/h XWH-1000 920,000 XWH-1300 1,300,000 XWH-1700 1,700,000 XWH-2000 1,999,900 XWH-2600 2,600,000 XWH-3400 3,400,000 WATER FLOW TEMPERATURE RISE - °F (°C) 40 60 70 80 90 100 120 140 (22) (33) (39) (44) (50) (56) (67) (78) GPH 2,662 1,775 1,521 1,331 1,183 1,065 887 761 LPH 10,078 6,719 5,759 5,039 4,479 4,031 3,359 2,880 GPH 3,742 2,495 2,139 1,871 1,663 1,497 1,247 1,069 LPH 14,167 9,444 8,095 7,083 6,296 5,667 4,722 4,048 GPH 4,904 3,269 2,802 2,452 2,180 1,962 1,635 1,401 LPH 18,565 12,376 10,608 9,282 8,251 7,426 6,188 5,304 GPH 5,794 3,862 3,311 2,897 2,575 2,317 1,931 1,655 LPH 21,931 14,621 12,532 10,966 9,747 8,773 7,310 6,266 GPH 7,501 5,000 4,286 3,750 3,334 3,000 2,500 2,143 LPH 28,393 18,929 16,225 14,196 12,619 11,357 9,464 8,112 GPH 9,891 6,594 5,652 4,945 4,396 3,956 3,297 2,826 LPH 37,441 24,961 21,395 18,721 16,641 14,976 12,480 10,697 27 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS SINGLE HEAT EXCHANGER MODELS High Efficiency Condensing Circulating Water Heaters SINGLE HEAT EXCHANGER BOILER DOUBLE HEAT EXCHANGER MODELS SINGLE HEAT EXCHANGER MODELS SINGLE HEAT EXCHANGER BOILER SINGLE EXCHANGER BOILER Rough In Dimensions (Double) INHEAT DIMENSIONS (SINGLE) Rough In Dimensions (Single) ROUGH ROUGH IN DIMENSIONS (SINGLE) ROUGH IN DIMENSIONS (SINGLE) Models XWH-1000 XWH-1300XWH-2000 XWH-1700 MODELS XWH-2600 XWH-3400 XWH-1000 XWH-1300 XWH-1700 XWH-1000 XWH-1300 XWH-1700 Models XWH-1000 XWH-1300 XWH-1700 Dimensions inches inches mm inches mm DIMENSIONS INCHES CM INCHES CM INCHESmm CM DIMENSIONS INCHES CM INCHES CM INCHES Dimensions inches inches mm mm inches mm mm inches inches mm CMmm Dimensions inches Flue Outlet Diameter 6 152 8 152 8 203 FLUE OUTLET FLUE OUTLET 6 15 86 15 8152 20 Flue Outlet 8 152 8 20 88 20 10 203 25 Flue Diameter Outlet Diameter 6 152 8 152 8 203 DIAMETER DIAMETER Air Intake Diameter 6 152 6 152 8 203 Air Intake Diameter 6 152 6 152 8 203 AIR INTAKE AIR INTAKE Air Intake Diameter 6 152 6 152 8 8 20 8 10 NPT 25 203 15 6 15 8 202 inch NPT Water Inlet6 2201/2 inch DIAMETER DIAMETER Water Inlet 2 inch NPT 2 1/2 inch NPT Water Inlet 2 inch NPT 2 1/2 inch NPT Water Outlet 2 inch NPT 2 1/2 inch NPT 3 inch NPT 4 inch NPT WATER INLET 2 inch NPT 2 1/2 inch NPT WATER INLET Water Outlet 2 inch NPT 2 1/2 inch NPT Water Outlet 2 inch NPT 2 1/2 inch NPT Gas Inlet 2 inch NPT 2 inch 4NPT 2 inch NPT 2 1/2 inch NPT 3 inch NPT inch NPT WATER OUTLET WATER OUTLET Gas Inlet 2 inch NPT 2 inch NPT Gas Inlet 2 inch NPT 2 inch NPT 1199 49INLET 1245 2 inch NPT 57 1448 2 inch NPT 47 2 inch NPT GAS INLET A 3 inch NPT GAS A 47 1199 49 1245 57 1448 1448 A 47 1199 49 1245 57 B 68A 1727 76 1930 47 120 49 67 125 57 1702 145 A 47 119 4976 125 57 1930145 B 67 1702 1702 68 1727 67 C B67 29 68 7371727 29 76 7371930 170 68 29 173 76 737 193 B 78 198 8029 203 91 737 231 B C 29 737 29 737 C 29 737 29 737 29 38 965 37 940737 29 74 29 37 74 29 94074 C D D 37 940 38 C 38 965 36 91 3737 94 37 940 94 940 D 37 940 965 37 23 584 24 610 37 94 38 23 97 37 58494 D E E 23 584 23 D 23 584 22 56 2224 56 22 610 56 610 E 584 9 23 22961 9 229584 9 24 229 23 58 23 58 24 E F F 9 229 9 229 9 229 F 9 229 40864229 102 41 41 104229 34E 9 341049 864 9 23 9 34 23 986486423 F G G 34 34 864 34 864 H G 44 34 1118864 45F 34 45 1534 1143 71143864 18 6 6 15 864 34 86 34 86 34 G H 44 1118 86 45 1143 1143 45 1143 1143 J H 6 44 1521118 6 G 45 152 25 6 2545 152 10 10 10 25 6 6 152 6 152 44 112 45 114 45152 114 H J K J 11 6 279152 11 6 279152 11 6 279152 11 11 H 11 279 4 10 4 11 10 4 279 10 6 15 6 15 6279 15 J K K 11 279 279 11 L 12 305 11 279 12 305279 12 305 28 11 279 20 51 1912 48 19 305 48 305 J 11 28 11 28 11 L11 12 305 279 12 K L MODELS Models 12 31 11 28 12 31 K 28 DOUBLE HEAT EXCHANGER BOILER 12 31 12 31 13 33 DOUBLE HEAT EXCHANGER MODELS L VERSATILE MULTI-VENTING CONFIGURATIONS CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS XWH Model Circulating Water Heaters DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE VERTICAL VENTING HORIZONTAL VENTING VERTICAL VENTING VERTICAL VENTING DIRECT VENT, VERTICAL VENT HORIZONTAL INTAKE DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE HORIZONTAL VENTING DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE DIRECT VENT, VERTICAL VENT HORIZONTAL INTAKE DIRECT VENT HORIZONTAL DIRECT VENT VERTICAL DIRECT VENT VERTICAL DIRECT VENT HORIZONTAL Direct or sidewall vent for up to 100 equivalent feet (30 meters) of pipe. Lower installation cost with approved ULC S636 CPVC/ PVC venting material – uses CPVC for first 10 feet (3 meters) and PVC thereafter. Also approved for use with UL approved AL29-4C® stainless steel venting materials. For the detailed venting instructions review the XP water heater instruction manual at www.hotwater.com. ULC S636 APPROVED VENT AND AIR INTAKE FITTINGS EXHAUST/VENT TERMINATIONS (PVC) PART NUMBERS AIR INTAKE TERMINATION (PVC) PART NUMBERS DIRECT VENT, VERTICAL VENT HORIZONTAL INTAKE HORIZONTAL VENTING Models Pipe Size Vertical (PVC Rain Cap) Horizontal (PVC Tee w/Screens) Models XWH 1000 6” 320884-000 321765-000 XWH 1000 XWH 1300 XWH 1300 XWH 1700 8” XWH 2000 320884-001 Pipe Size Combustion Air Intake (Elbow) 6” 321764-000 8” 321764-001 10” 321764-002 XWH 1700 321765-001 XWH 2000 XWH 2600 XWH 2600 XWH 3400 10” 320884-002 321765-002 XWH 3400 Please note: When direct or sidewall venting, the water heater’s CSA certification requires that only the above approved vent and combustion air intake terminations be used. FLOW RATE GAS PRESSURE REQUIREMENTS TYPE OF GAS MODELS (XWH) 1000, 1300, 1700, 2000, 2500, 3400 Natural Propane MAXIMUM SUPPLY PRESSURE MINIMUM SUPPLY PRESSURE INCHES W. C. kPa INCHES W. C. kPa 14.0 3.49 4.0 1.0 14.0 3.49 4.0 2.0 ELECTRICAL REQUIREMENTS MODEL SUPPLY VOLTAGE (VOLTS) FREQUENCY (HZ) CURRENT (AMPS) XWH-1000 120V 60 30 XWH-1300 120V 60 30 XWH-1700 120V 60 30 XWH-2000 120V 60 60 XWH-2600 120V 60 60 XWH-3400 120V 60 60 ELECTRICAL NOTES: A dedicated, single phase, 30/60 amp circuit breaker with a grounded neutral should be provided to supply power to the water heater. A dedicated, single phase, 60/60 amp circuit breaker with a grounded neutral should be provided to supply power to the water heater. RECOMMENDED FLOW RATES @ 0-12 GRAINS PER GALLON MODELS TEMPERATURE RISE (rT °F) GPM PRESSURE LOSS IN FEET OF HEAD (P) XWH 1000 25 70 17.5 XWH 1300 25 99 22 XWH 1700 25 129 23 XWH 2000 25 153 17.5 XWH 2600 25 198 22 XWH 3400 25 261 23 Notes: For hard water systems with water hardness greater than 12 grains per gallon, A. O. Smith recommends a water softener be installed and maintained. The factory installed/supplied pump is sized to maintain a rT of 25°F through the water heater at 100% fire. In addition to the pressure loss through the water heater, the factory supplied pump is sized for an additional 50 equivalent feet (15 meters) of piping between the water heater and a storage tank. Consult the factory for systems where the piping between the water heater and the tank exceed 50 equivalent feet (15 meters). 29 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS Burkay® HW Gas Models 80% thermal efficiency hot water supply boilers. Famous Burkay reliability. Because of their lightweight and compact design, they may be easily transported on a two-wheel dolly replacing large boilers in a much smaller space. Burkay models are for indoor use in installations requiring higher inputs up to 670,000 BTU. They can be manifolded for unlimited fire power. All Non-Ferrous Waterways A ll castings are made of bronze or brass A ll water tubes are made from copper n B razed joints or flare union construction make the boiler immune to the effects of thermal shock and thermal cycling n n Efficient Copper Coil Combustion Chamber T he combustion chamber is a heat exchanger formed from a two passage coil of tightly wound continuous copper tube n Water circulating through this coil surrounds the main burner and captures the radiant heat n A wrap of insulation on the outside of the coil retains the heat captured by the circulating water n Copper Heat Exchanger D irectly above the coil and the main burner is a compact, horizontal, copper fin tube heat exchanger n T he flue gases must pass through this efficient heat exchanger before leaving the boiler n T his unique design provides maximum heat transfer and proven field durability n Thermal Balancer n LOW LEAD CONTENT P atented pump delay system that allows the boiler and pump to run simultaneously but delays pump shot off at end of heating cycle to remove usable heat from the heat exchanger and reduce the scale forming tendencies of motionless hot water Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty HEIGHT* IN (CM) DIAMETER IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 8 65 (165) 25 1/4 (64) 29 5/8 (75) 250 (113) 10 57 1/8 (145) 27 (69) 31 1/2 (80) 301 (137) 10 57 1/8 (145) 27 (69) 31 1/2 (80) 301 (137) 515 (1,949) 10 68 5/16 (174) 27 (69) 36 1/2 (93) 381 (173) 600 (2,271) 12 68 5/16 (174) 27 (69) 36 1/2 (93) 381 (173) RECOVERY 100°F (56°C) TEMP. RISE MODEL INPUT BTU/h OUTPUT BTU/h HW-300 300,000 240,000 297 (1,124) HW-399 399,000 319,200 388 (1,469) HW-420 420,000 336,000 413 (1,563) HW-520 520,000 416,000 HW-670 660,000** 528,000** GPH (LPH) VENT DIAMETER (IN) *Height to top of diverter **Propane: 670,000 BTU/h INPUT; 536,000 BTU/h OUTPUT. 30 Burkay Genesis® Circulating Water Heaters A. O. Smith Burkay Genesis water heaters offer everything you could ask for in a non-condensing water heater. They provide a near condensing 85% thermal efficiency, outstanding venting flexibility, space-saving stackable design and an advanced electronic control system. CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS 85% thermal efficiency hot water heater. Electronic Control with Precise Temperature Management Controls every electrical water heater function, including pump operation and main burner ignition, delivers precise temperature management with ±1ºF accuracy n Display panel shows current operating status and fault readings in easy-to-understand English instead of confusing numeric codes n Display also shows temperature set points, outlet temperature, current inlet/outlet differential (∆T) and tank temperature n Help screens assist in water heater set-up and explain all control options n When mounted in the storage tank, the included remote temperature sensor allows the tank temperature to be set and monitored at the water heater n LOW LEAD CONTENT HLW Multiple Venting Options n All Genesis models can vent vertically in Category I with double wall “B” vent or horizontally in Category IV with AL29-4C® stainless steel vent material Copper Finned-Tube Heat Exchanger Gasket-less glass-lined headers and copper finned tubes with extruded integral fins deliver exceptional heat transfer n ASME certified "HLW" stamped 160 psi working pressure n Copper is lightweight for easier handling and immune to thermal shock n Stage Gas Firing System Prevents short cycling and ensures smooth operation, saves fuel and extends product life n Delivers maximum output when demand is high, reduced firing rates during off peak times n Factory Start-Up Included n Required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certified start-up Codes and Standards n All models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 5-Year Limited Heat Exchanger/1-Year Limited Parts Warranty 31 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS Clean burning Stainless Steel Premix Burners for smooth ignition and clean combustion 32 RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) WATER CONNECTION (IN) GAS CONNECTION (IN) VENT / INTAKE CONNECTION (IN) HEIGHT IN (CM) WIDTH IN (CM) WIDTH WITH PUMP IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 399,000 412 (1,560) 2 1 1/4 6/6 31 1/2 (80) 37 5/8 (96) 46 1/2 (118) 22 1/4 (57) 454 (206) GWH-500 500,000 515 (1,949) 2 1 1 /4 6/6 31 /2 (80) 45 /8 (115) 54 /4 (138) 22 1/4 (57) 467 (212) GWH-650 650,000 670 (2,536) 2 1 1/4 8/8 31 1/2 (80) 56 3/4 (144) 65 5/8 (167) 22 1/4 (57) 551 (250) GWH-750 750,000 773 (2,926) 2 1 1/4 8/8 31 1/2 (80) 64 (163) 72 7/8 (185) 22 1/4 (57) 611 (277) GWH-1000 990,000 1,020 (3,861) 2 1/2 2 10/10 36 (91) 48 1/2 (123) 54 3/8 (138) 33 (84) 843 (382) GWH-1250 1,260,000 1,298 (4,913) 2 1/2 2 12/12 36 (91) 58 3/4 (149) 64 5/8 (164) 33 (84) 939 (426) GWH-1450 1,440,000 1,484 (5,618) 2 1/2 2 12/12 36 (91) 68 7/8 (175) 74 3/4 (190) 33 (84) 1,035 (469) GWH-1800 1,800,000 1,855 (7,022) 2 1/2 2 14/12 36 (91) 82 3/8 (209) 88 1/4 (224) 33 (84) 1,168 (530) GWH-2100 2,070,000 2,133 (8,074) 2 1/2 2 14/12 36 (91) 92 5/8 (235) 98 1/2 (250) 33 (84) 1,285 (583) MODEL INPUT BTU/h GWH-400 1 3 1 Mechanical Venting Flexibility Direct-Venting Examples A llows clean, uncontaminated air to be drawn directly into the unit n F lue gas by-products are expelled through the wall to the outside n T he water heater can be vented directly through an outside wall or vertically through the roof CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS Burkay Genesis® n Horizontal sidewall directventing rear intake/exhaust Vertical direct-venting top intake/exhaust Vertical direct-venting with horizontal combustion air in-take rear intake/top exhaust Other Genesis Features S tage firing - 2 stages Sealed combustion chamber n Stainless steel burners n All bronze circulating pump (shipped loose) n On/Off switch n Adjustable high limit with manual reset n Pump delay n ASME T&P relief valve 125 psi n Factory mounted flow switch n BMS terminal strip n Contacts for air louvers n Contacts on any failure n n Genesis Options C upro-nickel heat exchanger High gas pressure switch with manual reset n Low gas pressure switch with manual reset n Low water cut off with manual reset and test n Stack rack n Combustible floor shield (400 - 750) n International voltage (230V 50Hz) n Sequencing control panel with cascade/ lead-lag operation for 1-4 water heaters n n Horizontal direct-venting with vertical combustion air intake top intake/rear exhaust Conventional Venting Examples Horizontal sidewall-venting with rear exhaust Conventional verticalventing with top exhaust See Installation Manual for detailed venting information and maximum/minimum intake and venting distances. 33 CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS Up to 87% efficient, hot water supply with modulating fire 4:1 turndown. Variable Fire (VF) Circulating Water Heaters The VF Series Circulating Water Heaters are designed with one thing in mind: to provide the best value for our customer. These heaters deliver an exceptionally high thermal efficiency by combining an advanced modulating venturi-mixing gas/air ratio system with a vertical multi-pass copper heat exchanger for outstanding efficiency of up to 87%. The secret to the stunning performance of the VF Series is its flexibility. The VF is capable of firing from 100% to 25% or a 4:1 turndown ratio. The water heater’s output is based strictly on the current system demand and required BTUs needed to maintain the desired system set-point temperature. The VF’s modulating capability is virtually limitless. The VF Water Heater sets a high-efficiency standard by combining thermal efficiencies up to 87% with a smoother, more energy-efficient overall system operation. Advanced High Efficiency Combustion Technology n n V enturi-mixing gas/air ratio system works with variable speed blower to precisely mix gas and air throughout firing range 4:1 turndown fully modulating capability prevents energy stealing short cycling and provides smooth system operation with higher overall system efficiencies n n Category II and IV Listed n n n HLW n ™ Z ero clearance on sides and lightweight copper heat exchanger makes VF Series easier to move and install in limited spaces —perfect for retrofits F its in an elevator, ideal for boiler rooms with limited access — only 24˝ wide Multiple water heater systems provide increased turndown and even smoother, more efficient system operation 4 water heaters with 4:1 turndown = 16:1 total system turndown High Efficiency Copper Fin Tube Heat Exchanger n n 34 V ertical heat exchanger design encircles the burner with a combustion chamber that is a 360° wall of copper fin tubes A ll internal heat exchanger noncopper surfaces are glass lined with A. O. Smith's proprietary porcelain glass coating to resist rust R equires AL29-4C® gas tight rust resistant venting material Factory Start-Up Included n Compact, Low-Profile Design n Impervious to thermal shock Heavy duty gasket-less heat exchanger design R equired for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certified start-up Codes and Standards n A ll models meet the thermal efficiency and standby loss requirements of NRCan and current edition of ASHRAE/IESNA 90.1 Other VF Water Heater Features: n n n n n n n SME-rated T&P valve A Factory mounted flow switch C ontacts for 0-10 VDC BMS external control C ontacts for alarm or any failure A ll bronze factory supplied pump D igital inlet and outlet temperature readout M anual reset hi-limit 5-Year Limited Heat Exchanger /1-Year Limited Parts Warranty VF Water Heater Approved Options n F or optional equipment, see VF Water Heater spec sheet HEIGHT IN (CM) WIDTH IN (CM) DEPTH WITH PUMP IN (CM) DEPTH IN (CM) APPROX. SHIPPING WEIGHT LB (KG) 527 (1,995) 44 1/2 (113) 23 1/8 (59) 45 1/2 (116) 30 3/8 (77) 573 (260) 791 (2,994) 52 1/8 (132) 23 1/8 (59) 45 1/2 (116) 30 3/8 (77) 622 (282) 999,999 1,054 (3,990) 59 ¼ (150) 23 1/8 (59) 45 ½ (116) 30 3/8 (77) 662 (300) VWH-1500 1,500,000 1,582 (5,989) 65 3/8 (166) 27 1/8 (69) 51 (130) 31 5/8 (80) 1,118 (507) VWH-2000 2,000,000 2,109 (7,983) 76 5/8 (195) 27 1/8 (69) 51 (130) 31 5/8 (80) 1,187 (538) MODEL INPUT BTU/h VWH-500 500,000 VWH-750 750,000 VWH-1000 RECOVERY 100°F (56°C) TEMP. RISE GPH (LPH) Versatile Multi-Venting Configurations n Two-pipe direct-venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building 50 Equivalent Feet (15 Meters) Exhaust 50 Equivalent Feet (15 Meters) Intake 90 Degree Elbows = 5 Feet (2 Meters) 45 Degree Elbows = 2 1/2 Feet (1 Meter) CIRCULATING WATER HEATERS & HOT WATER SUPPLY BOILERS Variable Fire (VF) Circulating Water Heaters DIRECT-VENTING n Conventional venting, vertical or horizontal sidewall 50 Equivalent Feet Max (15 Meters) 90 Degree Elbows = 5 Feet (2 Meters) 45 Degree Elbows = 2 1/2 Feet (1 Meter) SIDEWALL CONVENTIONAL VENTINGVENTING Please consult latest edition of the Installation Manual for detailed venting information and maximum/minimum venting distances. VF Electronic Control The VF Electronic Control is designed to operate all the various elements of a domestic hot water heating system. The VF Electronic Control will control temperature, operate the pump and dispense a large amount of operational data. Electronic Modulating Control n Modulates the burner to maintain tank temperature within ±1ºF n Infinite burner firing rate that modulates between 25% and 100% fire n L ED display provides current water heater status in easy-to-understand English with help screens to assist should a fault occur n C ontrols and monitors every electrical water heater function with onboard diagnostics n B uilding Management System (BMS) integration with 0-10 VDC input allows BMS to control water heater firing rate 35 ELECTRIC BOILERS & HOT WATER GENERATORS Heavy-Duty Electric Dura-Power™ NW Boiler Models Designed for use as a hot water boiler for space heating applications. ASME Code Construction A ll vessels manufactured to applicable ASME code V essels with maximum working pressure of 160 psi or less (standard design is for 125 psi) at 240ºF maximum temperature bear the “H” symbol per Section IV of ASME Code n V essels with greater than 160 psi working pressure or higher than 240°F operating temperature will bear the "S" symbol per Section I of ASME Code n n Incoloy Immersion Heaters H eavy-duty medium-watt density elements (3 per immersion heater) n Incoloy sheathing provides excellent protection against oxidation and scaling n Inputs range from 45 kW to 6,000 kW n Control and Power Circuit Fusing n 1 00,000 amp I.C. cartridge-type fuses protect all elements and contactors Pilot Switch and Light P ermits manual starting and stopping of heater by interrupting power to the control circuit n Pilot light indicates when control circuit is energized n Heavy-Duty Magnetic Contactors n U L-rated for 100,000 cycles Low Water Cut Off n Optional Goldenrod® 24-karat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500ºF. robe type, electric low water cut off prevent energizing P of elements in the event of low water condition 120V Control Circuit n Powered by fused transformer Modulating Step Control n S olid-state modulating step control modulates heat input to match load 1-Year Limited Tank/1-Year Limited Parts Warranty MODEL 36 CAPACITY USG (L) MAXIMUM KILOWATTS HEIGHT** IN (CM) WIDTH IN (CM) DEPTH IN (CM) INLET & OUTLET* (IN) BOILER DRAIN (IN) NW-37 37 (140) 180 42 (107) 32 (81) 30 (76) 3 1 NW-60 60 (227) 300 57 (145) 32 (81) 30 (76) 3 1 1 1 /4 NW-96 96 (363) 480 69 1/2 (177) 36 (91) 38 (97) 4 NW-150 150 (568) 720 69 1/2 (177) 54 (137) 44 (112) 5 1 1 /2 NW-220 220 (833) 1,140 71 (180) 60 (152) 50 (127) 5 1 1 /2 NW-334 334 (1,264) 1,740 99 (251) 60 (152) 50 (127) 6 2 NW-400 400 (1,514) 2,100 90 1/2 (230) 66 (168) 56 (142) 8 2 NW-500 500 (1,893) 2,580 90 1/2 (230) 72 (183) 62 (157) 8 2 NW-670 670 (2,271) 3,300 96 1/2 (245) 78 (198) 68 (173) 8 2 NOTE: For boilers 3400 kW to 6000 kW, consult factory *All fittings under 4˝ will be threaded type. All fittings 4˝ and larger will be flanged. **Where overall height is a problem, a larger diameter vessel with a reduced height may be furnished Field certification required on all NW installations in Canada. Packaged Hot Water Generating (HWG) Systems - Steam/Hot Water These skid-mounted water heater systems are completely assembled and packaged for use. All components are sized, piped and checked at the factory before shipment. HWG systems are available in space saving vertical or horizontal models. ELECTRIC BOILERS & HOT WATER GENERATORS Designed for utilizing steam or high temperature boiler water as the energy source. Custom units built to order, with tank capacities up to 12,000 gallons including special control trim and special heating units can be built to design specifications on a special order basis. Insulation n odels are insulated with M fiberglass to meet or exceed the thermal efficiency and standby loss requirements of NRCan and the most current edition of ASHRAE/IESNA 90.1 Integral Pump n System includes an integral bronze circulator pump Steam Units n Standard steam trim consists of temperature control valve, inlet and auxiliary steam traps, inlet and auxiliary strainers, steam pressure gauge with siphon, vacuum breaker and air vent Boiler Units n S tandard boiler water trim includes temperature control valve and boiler water temperature gauge Cathodic Protection n S tandard systems employing glass, cement or epoxylined tanks are fitted with magnesium anodes to help prevent corrosion Gallon Sizes n WG models are available H from 140 gallons to 12,000 gallons in both vertical and horizontal configurations Additional Features A ll-copper recirculation with two bronze ball valves n F lush-mounted T&P gauges n A SME-rated T&P valve n 5-Year Limited Tank Warranty and 1-Year Limited Coil Warranty Options S torage Tanks: 150 through 160 psi working pressure, ASME Section VIII construction, 4˝ x 6˝ hand hole, 11˝ x 15˝ manhole, cement or epoxy lining n W ater to Water: Self actuated or pneumatic operated temperature regulator and a bypass loop in boiler water line for regulator isolation n S team to Water: Pilot (spring, air, temperature) operated temperature regulator n HLW U Code Listing n T he standard system will employ an ASME "HLW" code glass-lined storage tank fitted with an ASME "U" code ¾" diameter copper tube heat exchanger For GPH recoveries, consult spec sheet. 37 STORAGE TANKS Custom Small and Large Volume Storage Tanks (T, TL, TN ,TJ, TJV, TJVT, TJH, TJHT) These storage tanks are ideal for use with gas-fired copper heat exchanger equipment and other A. O. Smith hot water systems for storage of any potable water at temperatures of 180ºF or lower. Sizes range from 80 to 12,500 gallons and custom models are available with special linings, heating coils (single-or double-wall), and accessories. Glass-Lined Tank Internal surfaces exposed to water are glass-lined per ASME HLW procedures n Some tanks use an NSF-approved glass-lining compound n Horizontal or Vertical Mounting " H" in the model number indicates horizontal only and "V" indicates vertical only n T J-80 (vertical only) and TL-500 (horizontal only) n Jacketed Tanks n T anks surrounded with high-density fiberglass insulation to meet or exceed the thermal efficiency and standby loss requirements of NRCan and the most current edition of ASHRAE/IESNA 90.1 Anodic Protection n M agnesium anodes help extend tank life ASME Construction S tandard on TJV/TJH-jacketed tanks 140 gallons and larger or with an "A" in the model number n 1 00, 125, 150 and 160 psi maximum working pressures available n HLW U LOW LEAD CONTENT 5-Year Limited Tank/1-Year Limited Parts Warranty (Except T120V & T200V models which have a 3-year limited tank warranty) Options F actory jacketing and insulation M anholes/hand holes n F actory-installed T&P valves n A ngle base n R ing base n H orizontal tank saddles n L ifting lugs n M ilitary specifications n n Other Linings Available C ement formulation provides excellent corrosion protection; available on 200-gallon and larger sizes n E poxy lining is suitable for cold or hot water storage; available on 200-gallon and larger sizes n Other Constructions n 38 B lack steel, stainless and silicon bronze tanks are available for extreme severe or special applications; ASME is standard STORAGE TANKS BARE (UNINSULATED) STORAGE TANKS MODEL Desired temperatures in A. O. Smith custom-lined hot water storage tanks can be maintained with special copper tube heating elements. Available for use with steam or boiler water, single- or double-wall construction. HD Custom Tanks Built to Order for Any Need A. O. Smith understands the variety of special needs you may have in designing a complete commercial hot water supply system. We can meet just about any need you specify, with our “HD” heavy duty large volume custom built storage tanks from 80 to 12,500 gallons, all with ASME construction, and with an extensive list of options, including: ement, epoxy or glass linings C Black steel tanks, stainless-steel tanks, silicon bronze tanks n Military specifications n M anholes n Hand holes n Lifting lugs n Steam or hot water tank heaters n Special and additional tank openings n Leg and ring bases n Horizontal tank saddles n Factory-mounted T&P gauges 12,500 CAPACITY USG (L) APPROX. OVERALL DIMENSIONS DIA. X LENGTH IN (CM) WORKING PRESSURE (PSI) APPROX. SHIPPING WEIGHT LB (KG) T-80S 80 (303) 20 x 62 1/8 (51 x 158) 150 170 (77) T-120S 119 (450) 24 1/4 x 65 (62 x 165) 150 287 (130) T-120V 119 (450) 24 x 60 3/4 (61 x 154) 150 270 (122) T-140A 140 (530) 24 x 76 1/4 (61 x 194) 125 400 (181) T-200V 188 (712) 28 x 75 (71 x 191) 125 402 (182) T-200S 200 (757) 30 x 72 (76 x 183) 150 460 (209) T-200A 200 (757) 30 x 72 (76 x 183) 125 460 (209) T-250A 250 (946) 30 x 84 (76 x 213) 125 505 (229) T-350S 350 (1,325) 36 x 88 (91 x 224) 125 670 (304) T-350A 350 (1,325) 36 x 88 (91 x 224) 125 670 (304) T-400A 400 (1,514) 36 x 97 (91 x 246) 125 775 (352) TL-500A 500 (1,893) 36 x 122 (91 x 310) 125 950 (431) TN-500A 500 (1,893) 42 x 89 (107 x 226) 125 815 (370) T-500A 500 (1,893) 48 x 74 (122 x 188) 125 950 (431) T-750A 750 (2,839) 48 x 106 (122 x 269) 125 1,290 (585) T-1000A 1,000 (3,785) 48 x 138 (122 x 351) 125 1,655 (751) VERTICAL JACKETED (INSULATED) STORAGE TANKS MODEL CAPACITY USG (L) APPROX. OVERALL DIMENSIONS DIA. X HEIGHT IN (CM) WORKING PRESSURE (PSI) APPROX. SHIPPING WEIGHT LB (KG) TJ-80S 80 (303) 25 ¼ x 63 (64 x 160) 160 236 (107) TJ-80A 80 (303) 26 ½ x 54 7/8 (67 x 139) 160 369 (167) TJV-120A 119 (450) 28 x 61 ¾ (71 x 157) 160 411 (186) TJV-120M 119 (450) 29 3/8 x 62 (75 x 157) 160 320 (145) TJV-140A 140 (530) 30 x 87 (76 x 221) 125 516 (234) TJV-200A 200 (757) 36 x 83 (91 x 211) 125 612 (278) TJV-200M (ASME) 180 (681) 32 x 77 (81 x 196) 160 560 (254) TJV-250A 250 (946) 36 x 96 (91 x 244) 125 900 (408) TJV-350A 350 (1,325) 42 x 97 (107 x 251) 125 1,080 (490) TJV-400A 400 (1,514) 42 x 105 (107 x 267) 125 1,282 (582) TJVT-500A 500 (1,893) 48 x 100 (122 x 254) 125 1,459 (662) TJV-500A 500 (1,893) 54 x 84 (137 x 213) 125 1,616 (733) TJV-750A 750 (2,839) 54 x 116 (137 x 295) 125 2,485 (1,127) TJV-1000A 1,000 (3,785) 54 x 150 (137 x 376) 125 3,410 (1,547) n HORIZONTAL JACKETED (INSULATED) STORAGE TANKS n MODEL CAPACITY USG (L) APPROX. OVERALL DIMENSIONS DIA. X LENGTH IN (CM) WORKING PRESSURE (PSI) APPROX. SHIPPING WEIGHT LB (KG) TJH-200A 200 (757) 36 x 77 (91 x 196) 125 790 (358) TJH-250A 250 (946) 36 x 90 (91 x 229) 125 1,000 (454) TJH-350A 350 (1,325) 42 x 93 (107 x 236) 125 1,370 (621) TJH-400A 400 (1,514) 42 x 99 (107 x 251) 125 1,476 (670) TJHT-500A 500 (1,893) 48 x 94 (123 x 239) 125 1,448 (657) TJH-500A 500 (1,893) 54 x 79 (137 x 201) 125 1,541 (699) TJH-750A 750 (2,839) 54 x 110 (137 x 279) 125 2,575 (1,168) TJH-1000A 1,000 (3,785) 54 x 143 (137 x 363) 125 3,261 (1,479) For complete specifications on A. O. Smith Commercial Storage Tanks, consult spec sheets at www.hotwater.com. 39 REMOTE MONITORING iCOMM™ Remote Monitoring System Hardware For information and ordering call 1-888-WATER02 or visit www.aosmithconnect.com. iCOMM Features MODEL ITEM DESCRIPTION ICMA iCOMM Communications Module IMDA iCOMM Multi-Device Adapter Needed if more than one water heater will be connected to the control module. Order 1 MDA for each water heater installed. IABA iCOMM Alarm Box Accessory alarm box that includes an audible alarm and alarm light. Main communications board required for any iCOMM installation. Note: If using wireless internet an optional wireless adapter is needed to provide wired connection to the communications module. Recommended adapter Linksys WGA600N or equivalent. P rovides remote monitoring via www.aosmithconnect.com n E -mail and text messaging of fault conditions n L eak detection and notification n G raphs unit performance and operational history n B ACnet compatibility with building management systems n iCOMM Requirements F acility must have “always on” internet (wired or wireless) n iCOMM compatible water heater n Compatible Units Include: Cyclone® MXi (BTH models) Cyclone Xi™ (BTX and BTXL models) n Custom Xi™ (DSE models) n Gold Series Xi™ (DVE models) n Heavy Duty Dura-Power™ Xi (DVE/DHE models) n Genesis™ Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (GB/GW models) n VF™ Variable Fire Domestic Water Heaters and Boilers manufactured between July 2009 and January 2014 (VB/VW models) n n 40 Building Management System BACnet and MODBUS Interface REMOTE MONITORING Introducing the BMS gateway for control of A. O. Smith Water Heaters. Models: ETH-1000 Ethernet connection XLTR-1000 Serial RS-485 connection Connect your A. O. Smith water heater to your building management system using the new Millennium control from ICC (Industrial Control Communications, Inc.) W orks with Cyclone®, McBee DVE, Renton DSE/ DVE/DHE 150 kW or less n Use the ICC Control to enable/disable the water heater n C hange temperature set points and differentials n T wo models with four different configurations to connect to BACnet and MODBUS n E thernet and Serial RS-485 versions available n 2 wire or 4 wire RS-485 Network n P ower can be supplied via the USB cable, as a 7-24 VDC input on the main terminal block, or via IEEE 802.3af Power over Ethernet (PoE on ETH-1000 only) n Configure protocols, network characteristics, and client/server object definitions n G raphically interact with the internal database in real-time via USB connection n A utomatically discover and configure IP settings Ethernet gateways connected to the current subnet n U pdate firmware n H eater connection wiring supplied with unit n F or questions on this product call 888-928-3702 Opt 1 n R TU and serial connect via RS-485 n E thernet and IP connect via RJ-45 ICC ENERGY MANAGEMENT INTERFACES PROTOCOL PART # 9910093000 n 9910094000 CONNECTION TYPE Serial (RS485) BACnet 9910099000 9910100000 9910096000 9910097000 Ethernet (IP) Serial (RS485) MODBUS 9910102000 9910103000 Ethernet (IP) APPLICATION Commercial Gas - Cyclone® BTH and BTX(L)-100 Commercial Electric - DSE, DVE, DHE 150 kW or less Commercial Gas - Cyclone® BTH and BTX(L)-100 Commercial Electric - DSE, DVE, DHE 150 kW or less Commercial Gas - Cyclone® BTH and BTX(L)-100 Commercial Electric - DSE, DVE, DHE 150 kW or less Commercial Gas - Cyclone® BTH and BTX(L)-100 Commercial Electric - DSE, DVE, DHE 150 kW or less 41 Innovation Continues to Lead. For over 140 years, A. O. Smith has built a reputation for innovation and this continues to lead with our most complete line of products yet. With the trademark blend of innovative technology and energy-efficient solutions, our comprehensive line is the natural source for everything from the smallest light commercial installation all the way up to the largest multi-structure complex. We offer over 500 different commercial models, including gas-fired, oil-fired and electric configurations, ranging in capacities from 5 gallons to 12,500 gallons, with input range from 50,000 BTU to the equivalent of 2,500,000 BTU. Through an inspired blend of innovation, efficiency and over 140 years of expertise, A. O. Smith continues to set the industry standard for performance and quality of water heaters and storage tanks. 42 No Other Company is Better Qualified to Fill Your Hot Water Needs. Knowledgeable People at Your Service To better serve our customers, A. O. Smith has over 200 manufacturer’s representatives covering Canada and the United States. In addition, we have more than 400 factory-authorized service technicians to provide reliable, immediate warranty services. We also maintain a well-staffed Customer Care and Technical Support facility in Fergus, Ontario that can provide information on A. O. Smith products, sizing, competitive analysis, etc. A. O. Smith Customer Care Facility “Our job is to ‘smooth the road’ from proper product selection to installation, and to help customers over the ‘potholes’ of troubleshooting service.” Stratford, Ontario Renton, Washington Fergus, Ontario McBee, South Carolina Ashland City, Tennessee Johnson City, Tennessee Veldhoven, The Netherlands Istanbul, Turkey Nanjing, China India Juarez, Mexico A. O. Smith has facilities located worldwide. Plants are located in strategic locations throughout North America, providing timely shipments to wholesalers. In addition, manufacturing plants are also located in Nanjing, China, to supply the ever-increasing demand for water heaters to the expanding Far East. Juarez, Mexico; Fergus and Stratford, Ontario; Veldhoven, The Netherlands and Istanbul, Turkey round out the facilities worldwide and demonstrate A. O. Smith’s global reach! 43 Notes 44 Notes 45 A. O. Smith Enterprises Ltd. 599 Hill Street West • Fergus, Ontario Canada N1M 2X1 Customer Service: 1-888-599-2837 Technical Support: 1-888-479-8324 www.hotwater.com A. O. Smith reserves the right to make product changes or improvements at any time without notice. Form No. CANAA80000 AUGUST, 2016 5M-MSI -0104 ©2016 A. O. Smith Enterprises Ltd. All rights reserved. Printed in Canada
© Copyright 2026 Paperzz