jamesbury APPLICATION REPORT Chlorine Vaporizer Pressure Indicator PI Rupture Disc Barometric Leg Pressure Indicator PI 6 Tubes Superheat Section Expansion Chamber 3 7 1 8 2 7 Level Transmitter Liquid Chlorine from Source LT Low Temperature Alarm Reserve Container PC A Condensate Outlet 5 5 Drain PI 4 8 Pressure Indicator Flow Control Steam or Hot H20 Chlorine Vaporizer Manual/Isolation Valve Rotary Control Valves 4 1/4" (8DN) 9FA 2236 XT 1 5 1" (25DN) 9FA 2236 XT 6 1/4" (8DN) 9FAC 2271 XT (40 – 50DN) 7150C 2271 XTZ1 8 Chlorine Gas to Process 1" - 2" (25 – 50DN) 7150 31 2236 XTZ1 1" - 2" (25 – 50DN) 7150 31 2236 XTZ1 w/ QPX Actuator w/ Positioner * (40 – 50DN) 7150C 31 2271 XTZ1 w/ QPX Actuator w/ Positioner * Emergency Shutdown Valve 3 2" - 3" (50 – 80DN) 7150C 31 2271 XTZ1 w/ VPVL Actuator Spring Return FC * Positioner can be: NE Style Electro Pneumatic NP Style Pneumatic ND Style Digital Chlorine Processing Vaporizing Chlorine is often supplied to a process as a vapor but is delivered to a processing site in liquid form, usually in a bulk container. It is possible to withdraw Cl2 from the vapor space in a bulk container. However, it’s impossible to sustain high feed rates. As the vapor is released, the pressure drops and the Cl2 cools and produces less vapor. The process of turning Cl2 liquid to vapor involves the application of heat under controlled conditions. The vaporizer is where this occurs. Chlo7 • 8/2011 APPLICATION REPORT Valve Requirements (1 ) Hot water at 140°F (60°C) or 75 psi (5 bar) steam is modulated to maintain vapor producing temperature in the liquid Cl2 chamber of the vaporizer. (2 ) Cl2 feeds the process at about 90°F (32°C) and 80 psi (6 bar) through a rotary control ball valve. Process pressure regulates valve position. A fail closed emergency shut down valve (3 ) isolates the vaporizer from process and can be instrumented to fail on signal from a variety of sources. Shut-off logic is process dependent. There are numerous drain and isolation valves. Flanged manual valves (8 ) isolate the vaporizer, hot H2O or steam control valves. Manual Cl2 valves (7 ) isolate the Cl2 control valve. A thread end valve (4 ) isolates the Hot H2O or steam pressure gauge. The Cl2 gas pressure gauge is isolated by a threaded Cl2 valve (6 ). The condensate outlet and vaporizer drain lines shut off with 1" (25DN) thread-end valve (5 ). The information provided in this bulletin is advisory in nature, and is intended as a guideline only. For specific circumstances and more detailed information, please consult with Metso. Metso Automation Inc. Europe, Vanha Porvoontie 229, P.O. Box 304, FI-11301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151 North America, 44 Bowditch Drive, P.O. Box 8044, Shrewsbury, MA 01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172 South America, Av. Independéncia, 2500- Iporanga, 18087-101, Sorocaba-São Paulo Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748/49 Asia Pacific, 20 Kallang Avenue, Lobby B, #06-00, PICO Creative Centre, Singapore 339411, Singapore. Tel. +65 6511 1011. Fax +65 6250 0830 China, 19/F, the Exchange Beijing, No. 118, Jianguo Lu Yi, Chaoyang Dist, 100022 Beijing, China. Tel. +86-10-6566-6600. Fax +86-10-6566-2575 Middle East, Roundabout 8, Unit AB-07, P.O. Box 17175, Jebel Ali Freezone, Dubai, United Arab Emirates. Tel. +971 4 883 6974. Fax +971 4 883 6836 www.metso.com/automation
© Copyright 2024 Paperzz